Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SRS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Degradation of Saltstone Disposal Unit Cementitious Materials

The Saltstone facilities at the DOE Savannah River Site (SRS) are used to stabilize and dispose of low-level radioactive salt solution originating from liquid waste storage tanks at the site. The Saltstone Production Facility (SPF) receives treated salt solution and mixes the aqueous waste with dry cement, blast furnace slag, and fly ash to form a grout slurry which is mechanically pumped into concrete disposal cells that compose the Saltstone Disposal Facility (SDF). The solidified grout is termed “saltstone”. Cementitious materials play a prominent role in the design and long-term performance of the SDF. The saltstone grout exhibits low permeability and diffusivity, and thus represents a physical barrier to waste release. The waste form is also reducing, which creates a chemical barrier to waste release for certain key radionuclides, notably Tc-99. Similarly, the concrete shell of a saltstone disposal unit (SDU) represents an additional physical and chemical barrier to radionuclide release to the environment. Together the waste form and the SDU compose a robust containment structure at the time of facility closure. However, the physical and chemical state of cementitious materials will evolve over time through a variety of phenomena, leading to degraded barrier performance over Performance Assessment timescales of thousands to tens of thousands of years. Previous studies of cementitious material degradation in the context of low-level waste disposal have identified sulfate attack, carbonation-influenced steel corrosion, and decalcification (primary constituent leaching) as the chemical degradation phenomena of most significance under SRS exposure conditions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Annual Radioactive Waste Tank Inspection Program - 2018

The Department of Energy (DOE) requires that Savannah River Remediation LLC (SRR), the Liquid Waste contractor, maintain a robust and timely Structural Integrity Program for waste tanks that are leak-tight and for waste tanks that have leaked or are suspect. These requirements are promulgated in DOE Manual 435.1-1, Section II.Q.(2). A key aspect of SRR's implementation of these requirements is its annual tank inspection program. In 2018, the SRR Visual and In-Service Inspection Program used two visual imagery techniques to ascertain the integrity of the Savannah River Site (SRS) waste tanks: high resolution digital photography and closed-circuit television. The primary inspection method made use of direct photograph techniques, e.g., making a series of photographs providing detailed views of the tank and wide-angle photography for obtaining overviews of large areas. Closed-circuit television was then typically used to further investigate conditions found during the initial inspection. During 2018, a total of 4,853 photographs were taken and 47 video inspections were performed as part of this inspection program. Of the 51 waste tank systems at SRS that were designed, constructed, and placed into active service storing radioactive liquid waste, 43 remain in active service. Eight tanks have been cleaned, stabilized by filling with engineered grout, and removed from service (also known as operationally closed) -Tanks 5, 6, and 12 (Type I tanks); Tank 16 (Type II tank); and Tanks 17, 18, 19, and 20 (Type IV tanks). For the 43 waste tanks, inspections were successfully conducted in 2018 through all accessible annulus risers and inspection ports for nine Type I tanks, three Type II tanks, and 27 Type III/IIIA tanks; at least one inspection was made in the interior of four Type IV tanks (i.e., the tanks without annular spaces) above the liquid level in the tank. Rainwater continues periodically to be observed migrating into the annuli of some tanks. Evidence of this infiltration was primarily noted by observation of surface stains, and occasionally by calciferous deposits, changed configuration of salt deposits in the associated annulus, and mild surface corrosion. The conditions of the 43 tanks remained essentially unchanged from the conditions reported in 2017. The one key exception was the identification of eight new cracks in the Tank 15 primary tank wall. These newly identified cracks are located at 65, 67, 70, 76, 150, 152, 176 inches and 200 inches above the tank bottom. The identified cracks in Tank 15 do not constitute an impact on the structural integrity of the tank, as evaluated and confirmed in the referenced report, SRNS-STI-2008-00028, A Structural Impact Assessment of Flaws Detected During Ultrasonic Examination of Tank 15, and calculation, T-CLC-H-00890, Calculation of Critical Crack Lengths in HLW Tank 15. The 2018 inspection program confirmed the structural integrity and waste confinement capability of all 43 waste tanks.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Methylmercury and Ethylmercury Analytical Performance in SRR Samples Measured by SRNL and Eurofins Frontier Global Sciences

Existing models and simulants of tank disposition media at the Savannah River Site (SRS) have presumed the presence of high concentrations of inorganic mercury. However, quarterly Tank 50 analyses have shown that mercury is present as organomercurial species at concentrations that may present challenges to its remediation and disposition and may challenge the Waste Acceptance Criteria (WAC) for Saltstone. Todate, methylmercury analyses for Savannah River Remediation (SRR) have been performed at an off-site laboratory by Eurofins Frontier Global Sciences (FGS) in Bothell, WA. Savannah River Remediation requested the development of methylmercury and ethylmercury determination capabilities at the Savannah River National Laboratory (SRNL) to support the Liquid Waste Operations at SRS. As part of that method development, SRR requested that SRNL Analytical Development (AD) compare their results with those obtained from their outside contract laboratory, Eurofins FGS. This document reports on this method development work as well as the comparative analyses conducted between the two laboratories. A series of optimization and validation experiments has been performed at SRNL, which has resulted in the development of on-site methylmercury and ethylmercury speciation capabilities using purge and trap (P&T) gas chromatography (GC) coupled with thermal desorption (TD) cold vapor – atomic fluorescence spectroscopy (CVAFS). Speciation has been achieved for both species, with a methylmercury method reporting limit (MRL) value of 1.13 pg and an overall uncertainty (1σ) of 5.1%. An ethylmercury MRL of 11.5 pg and an overall uncertainty (1σ) of 4.8% were obtained. These analytical parameters compare favorably with Eurofins FGS, which demonstrates uncertainties (1σ) for methylmercury and ethylmercury of 13% and 9.1%, respectively. Results obtained by SRNL from the routine analysis of Tanks 21, 40, 50, and 51 samples have provided statistically indistinguishable results compared with Eurofins FGS. Based upon the work performed by SRNL-AD and the data currently available, the following recommendations can be made: Further work should be performed to determine a “best practices” for sample holding time prior to analysis (both preserved and non-preserved samples), as well as any detrimental effects sample age may have on data quality. Analysis of ethylmercury is only recommended for tank samples that are reasonably expected to have significant quantities of ethylmercury, such as from the DWPF SMECT. Trace levels of ethylmercury in the presence of large quantities of methylmercury can be difficult or impossible to quantify. SRNL-AD development of methods for total mercury, purgeable mercury (which includes Hg(0) and dimethylmercury), inorganic mercury (Hg(I) and Hg(II)), dissolved mercury, and particulate mercury are underway and will be reported upon separately.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Soluble and Particulate Mercury Deployment of Analytical Method for the Savannah River Site Liquid Waste System

Savannah River National Laboratory (SRNL) developed, tested, and deployed in a radiological containment unit (CU) an analytical method for quantifying particulate total mercury and soluble total mercury in radioactive samples such as the those generated by the dilution of Savannah River Site (SRS) High-Level Waste. This method relies on direct mercury analysis and other associated capabilities for matrix independent quantification of total mercury in solids or liquids (i.e., any sample that can be introduced into the instrument oven for pyrolysis to release all mercury for measurement). The matrix independence allows for discreet measurements of the starting sample, the collected particulates and the filtrate liquid, thus enabling a mass balance quality check. For example, an analysis of a diluted sample from the SRS liquid waste system (LWS) resulted in a measured total mercury value of 55.0 mg Hg/L and a nearly matching calculated total mercury value of 55.1 mg Hg/L (± 20% 2σ) from the summation of measured soluble mercury (47.8 mg Hg/L ± 20% 2σ) and measured particulate mercury (7.26 mg Hg/L ± 20% 2σ). The advantages of the particulate-soluble mercury analysis method are: waste minimization using small radioactive liquid volumes, minimal radiological sample processing and reduced handling steps protective of workers (ALARA) and improved data quality, syringe filter technology which eliminates vacuum filtration and the potential loss of volatile species, small diameter filters (13 mm nominal to 25 mm if needed to avoid clogging) and small disposable poly filter holders (no need to clean) which minimize waste, flexibility provided for a range of starting concentrations, particulate-soluble ratios, and sample matrix conditions, soluble and particulate are measured results that, when summed, and are in good agreement with the total mercury measurement.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Chemistry Envelope for Pitting and Stress Corrosion Cracking Mitigation

The present waste chemistry controls for the Hanford double-shell tanks (DSTs) were established in the 1980s in response to tank failures caused by stress corrosion cracking (SCC) at the DOE Savannah River Site (SRS). Portions of the SRS chemistry limits were coupled with corrosion testing results from Pacific Northwest Laboratory (PNL) and adopted for corrosion control of the DST waste at the Hanford Site. Since that time, the temperatures of many DST wastes have decreased to less than 50 °C as the radioactive material has decayed, the testing program in Argentina demonstrated that chloride ion in Hanford Site waste could cause pitting, and other work showed that dilute solutions could cause pitting at the liquid air interface (LAI). Moreover, future transfers from the single shell tanks and the waste treatment plant and process changes may shift the DST waste chemistries to a broader range of compositions with higher aggressive anion concentrations than the wastes that are presently stored. The decreasing temperatures led to the formulation of new chemistry controls for the minimization of SCC risks for operations below 50 °C in 2010, and these controls were partially adopted. The Tank Integrity Expert Panel (TIEP) Corrosion Subgroup (CSG) recommended that additional testing be performed to assess the potential for pitting and LAI corrosion. Since 2015, DNV-GL, SRNL, and the Hanford Site laboratory have investigated pitting and LAI corrosion at current and anticipated DST chemistries and Savannah River National Laboratory (SRNL) undertook a statistically based investigation of the role of nitrate and halide ion induced pitting corrosion. The objective was to develop a comprehensive waste chemistry envelope for the simultaneous minimization of the pitting and SCC risks caused by halide and nitrate ions. This report summarizes the technical basis for the new waste chemistry envelope to minimize the potential for both pitting and cracking corrosion induced by nitrate and halide ions, and the strategies used for the validation of the new controls.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Metal-Organic-Framework Glasses as Rad Contaminant Sequesters and Nuclear Waste Forms

Remediation of Tc remains an unresolved problem at SRS and other DOE sites. The objective of this project was to develop novel metal organic framework (MOF) glasses for radioactive contaminant sequestration and stabilization from aqueous media. During FY19, we synthesized, characterized and evaluated cetyl trimethylammonium bromide (CTAB)-functionalized and F – , Cl – , I – , CF 3 SO 3 – -exchanged MIL-101. MIL-101- CTAB was demonstrated to have high ReO 4 – removal capacity (~130 mg/g sorbent) from artificial groundwater. Re chemical speciation and binding mechanism in MIL-101-CTAB were also studied by synchrotron X-ray absorption spectroscopy. ReO 4 – was demonstrated as being in the pore structure with slightly larger Re-0 bond distances than those in NaReO 4 . In addition, a new Ni-TIPA MOF was demonstrated to be very stable, selective and effective for TcO 4 – removal from the SRS tank waste stream (~90% removal). This research may provide a highly applicable platform for solving critical DOE and industrial problems related to nuclear environmental stewardship and nuclear power production.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessment of Accident Dose Models Used at the Savannah River Site

AXAIRQ, PUFF-PLUME, and MACCS2 are available for atmosphere modeling of accidental releases at the Savannah River Site (SRS) by qualified users. All models assume Gaussian diffusion and use site-specific or user-specified meteorological data to estimate downwind doses. However, each model was developed, maintained and applied for different purposes for use at SRS. This report briefly describes the lineage of, highlights the differing assumptions for, and compares some results from each model. The report is not intended to be an exhaustive evaluation and/or comparison of the models but to document the capabilities and assumptions of the models to gain perspective on how the models differ.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Influence of Glycolate Anion on Aqueous Corrosion in DWPF and Downstream Facilities – SCC Testing

Glycolic acid is being evaluated as an alternate reductant in the preparation of High Level Waste for the Defense Waste Processing Facility (DWPF) at the Savannah River Site (SRS). During processing, the glycolic acid may not be completely consumed with small quantities of the glycolate anion being carried forward to waste facilities. The SRS liquid waste contractor requested an assessment of the influence of the glycolate anion on the corrosion of the materials of construction (MoC) throughout the waste processing system since this concern had not been previously evaluated. The influence of glycolic acid on the occurrence of stress corrosion cracking (SCC) had not been evaluated specifically in the previous testing. The present testing used electrochemical and coupon immersion testing to assess this influence. Additionally, the primary guidance on corrosion for operating DWPF with a formate-based flowsheet is based on testing that utilized test solutions with a small number of constituents. Recent testing used more complex solutions based on flowsheet development for DWPF. Additional electrochemical tests were also conducted to assess the influence of this difference on test results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fiberboard Properties and Degradation Rates for Storage of 9975 Shipping Package in KAC (2020 Status Report)

Savannah River Site (SRS) stores plutonium materials within model 9975 shipping packages in the K-Area Complex (KAC). The 9975 shipping package consists of a 35 gallon stainless steel drum, Celotex fiberboard insulation, lead shield, and primary and secondary containment vessels. The 9975 shipping package design, performance, and analysis for safe transport of radioactive material are described in the Safety Analysis Report for Packaging (SARP). Celotex fiberboard provides three safety functions: thermal insulation to limit internal temperature during a fire, criticality control, and resistance to package crushing. The fiberboard material must retain its dimensions and density within certain ranges to provide the required impact resistance, criticality control, and fire resistance. The SRS Surveillance Program monitors material performance to establish a basis for service life and ensures the continued integrity of 9975 packages. Fiberboard samples, taken from multiple fiberboard assemblies fabricated from cane and softwood fiberboard, have been conditioning in elevated temperature environments since 2005. The samples are periodically examined to monitor thermal, mechanical, and physical properties, and assess degradation trends. Fiberboard properties of interest that are evaluated to demonstrate acceptable long-term performance include dimensional stability, density, compressive strength, thermal conductivity, and specific heat capacity. Duplicate samples from multiple package sources have been tested to identify the range of variability in fiberboard properties and degradation rates. Baseline and long-term testing of fiberboard material properties have been reported previously; reference 6 summarized experimental results of cane and softwood fiberboard through May 2019 and presented degradation models for the measured properties. This report presents the cumulative data collected through June 2020 and the corresponding updated aging models.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Metal-Organic Framework Glasses as Rad Contaminant Sequesters and Nuclear Waste Forms

Remediation of Tc remains an unresolved problem at SRS and other DOE sites. The objective of this project was to develop novel metal organic framework (MOF) glasses for radioactive contaminant sequestration and stabilization from aqueous media. During FY20, we synthesized, characterized and evaluated additional cetyltrimethylcimmonium bromide (CTAB)-functionalized and F - , Cl - , I - , CF 3 SO 3 - exchanged MIL-101-Cr samples. MIL-10l-Cr-NO 3 -CTAB was demonstrated to have high ReO 4 - removed capacity (139 mg/g sorbent) from artificial groundwater (AGW). Re chemical specicition and binding mechanism on MIL-101-CTAB were also studied by synchrotron X-ray absorption spectroscopy. ReO 4 - was demonstrated as being in the pore structure with slightly larger Re-O bond distances than those in NciReO 4 and binding with the positively charged sites of CTAB. In addition, a new Ni-TIPA MOF was demonstrated to be very stable, selective and effective for TcO 4 - removed from the SRS tank waste stream (~90% removed). The Ni-TIPA MOF sample containing ReO 4 - was prepared and shipped/planned for vitrification studies by a high-pressure technique. This research may provide a highly applicable platform for solving critical DOE and industrial problems related to nuclear environmental stewardship and nuclear power production.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of stimulated Raman scattering using diode data at the Pecos experimental platform

In order to increase neutron yield in fusion experiments on the Magnetized Linear Inertial Fusion (MagLIF) platform, it is important to maximize the energy coupled to the fuel during the laser-preheat stage. However, laser-energy coupling is limited by laser—plasma instabilities (LPI). In this regard, the Pecos facility at Sandia National Laboratories uses the Z-beamlet laser to test and study the effects of LPI on MagLIF-relevant targets. In particular, stimulated Raman scattering (SRS) is measured in Pecos by using two photo-diodes and a near-beam imager. The measurements from the photo-diodes are processed using a synthetic spectrum based on a Gaussian model. With this relatively simple model, the mean wavelength and intensity of backscattered light can be deduced. Our measurements show similar trends as those given by time-resolved spectrometer data. Hence, this model provides a simple way to approximate time-resolved spectra for scattered light by SRS.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reporting the Radionuclide Inventory of the DWPF Product

In the Defense Waste Processing Facility (DWPF) at the Savannah River Site (SRS), the radionuclides contained in the liquid high-level waste currently stored at SRS are being converted into a durable borosilicate glass. This glass in its sealed stainless-steel canister, the DWPF product, eventually must be sent to a federal repository for final disposal. In order to ensure that the DWPF product is suitable for acceptance by the U. S. Department of Energy’s (DOE) Civilian Radioactive Waste Management System (CRWMS)*, the DOE Office of Environmental Management (DOE-EM) established the Waste Acceptance Product Specifications for Vitrified High-Level Waste Forms (WAPS). DOE-EM is tentatively performing surrogate CRWMS waste acceptance functions, as the office was eliminated in 2009, for review and concurrence of technical baseline documents and waste form non conformances. The specifications are divided into five sections, dealing with the waste form (borosilicate glass) itself, the canister, the canistered waste form, quality assurance, and documentation and other administrative requirements. The DWPF is required to document its compliance with the specifications in the Waste Form Compliance Plan (WCP), the Waste Form Qualification Report (WQR), the Production Records, and the Storage and Shipping Records. The WCP provides general information about the DWPF process and product, and a general description of the methods and programs by which the DWPF will demonstrate compliance with each specification in the WAPS. The WCP was vital to DWPF startup with respect to operations planning and also assurance to DOE that the canistered waste forms would be acceptable for disposal at any future High-Level Waste (HLW) geologic repository. The WQR is a compilation of the results of the testing and analysis programs identified in the WCP. The WQR details the method of compliance with each specification, and the testing performed to demonstrate the effectiveness of each method. The WQR is published in separate volumes which each correspond to one or more of the specifications. The WQR also contains a description of the DWPF’s Glass Product Control Program. Each volume contains Part and Item designators which indicate the corresponding item(s) in the WCP. The Production Records, and the Storage and Shipping Records document that each DWPF product has been produced and stored in compliance with the WAPS. This document, Volume 4 of the WQR, responds to WAPS Specifications 1.2.2, 1.6, and 3.14 which require that the DWPF report the radionuclide inventory of each canistered waste form, and of each waste type. This volume describes the systems the DWPF uses to determine and report the radionuclide inventory of the glass product, and provides evidence that these systems allow the DWPF to satisfy the WAPS specification. This volume of the WQR has been prepared to establish that methods are available to determine and report the radionuclide inventory, and that the DWPF is ready to collect the facility-specific data necessary to provide definitive estimates of the errors associated with the use of these methods.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Gandolinium poison solubility testing for the downstream impacts from accelerated basin de-inventory

The Accelerated Basin De-inventory (ABD) Program at the Savannah River Site (SRS) is designed to accelerate the de-inventory of L-Basin and accelerate the Spent Nuclear Fuel (SNF) Disposition mission. Spent fuel will be dissolved in H-Canyon without recovery of uranium. The dissolver solutions will be temporarily stored, pH-adjusted to excess hydroxide (which will facilitate precipitation of metal oxides/hydroxides), transferred to the Concentration, Storage, and Transfer Facility (CSTF), and subsequently immobilized in the Defense Waste Processing Facility (DWPF) during planned sludge batch campaigns. ABD accelerates basin closure, significantly reduces programmatic risk, and greatly reduces the lifecycle budget requirements for the site by eliminating the need for a SNF drying and packaging capability. The ABD approach represents a significant change to the clean-up approach for the SRS. However, the increased fissile loading in sludge batches, due to the dissolver solutions, requires investigation to ensure fissile limits are efficiently and safely managed; higher fissile loadings in the glass are projected to be two to three times higher than the current fissile concentration limit of 897 g/m 3 and will be addressed in a future report.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Geochemical data package for performance assessment calculations related to the Savannah River Site

The Savannah River Site (SRS) disposes of low-level radioactive waste (LLW) and stabilizes high-level radioactive waste (HLW) tanks in the subsurface environment. Calculations used to establish the radiological limits of these facilities are referred to as Performance Assessments (PAs), Special Analyses (SAs), and Composite Analyses (CAs). The purpose of this document is to revise the existing geochemical data package used for these calculations (Kaplan, 2016). This work builds on earlier compilations of geochemical data, referred to a geochemical data packages (Kaplan, 2007; Kaplan, 2010; Kaplan, 2016; McDowell-Boyer et al., 2000). This work is being conducted as part of the on-going maintenance program of the SRS PA programs that periodically updates calculations and data packages when new information becomes available.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Structural Integrity Evaluation of the Tank Farm Waste Transfer System

Radioactive supernate, salt, and/or sludge wastes (i.e., high level wastes) are confined in 45 underground storage tanks at the Savannah River Site (SRS). The waste is transported between tanks within and between the F and H area tank farms and other facilities on site via underground and a limited number of aboveground transfer lines. The Department of Energy - Savannah River Operations Office (DOE-SR) performed a comprehensive assessment of the structural integrity program for the Tank Farm waste transfer system at the SRS. This document addresses the following issues raised during the DOE assessment

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Antifoam Development for Eliminating Flammability Hazards and Decreasing Cycle Time in the Defense Waste Processing Facility

Foam, due to the high gas generation rates of boiling and chemical reaction offgasing, requires control measures to prevent the foam from contaminating the condensate and to facilitate efficient plant operation. Antifoam was utilized to minimize foam production during chemical processing in the DWPF and during High-Level Waste (HLW) evaporation at SRS and Hanford. However, the current antifoam used in the SRS DWPF increases flammability risk during chemical processing (generates three flammable degradation products) and while feeding the melter (can decompose to CO/hydrogen). It is also the likely source of methyl functional groups for the organo-mercury present in the tank farm and excessive mercury in Saltstone. Additionally, the planned startup of Salt Waste Processing Facility (SWPF), with much higher throughput, will challenge DWPF to process at higher gas generation rates. DWPF employs Antifoam 747, a superspreader produced by Momentive Performance Materials, as an antifoaming agent during waste processing. During DWPF chemical processing, antifoam must be effective up to boiling (i.e., up to 103°C) and between a pH of 3-13. Antifoam 747 is most effective at a pH range of 6-8 and degrades as pH deviates. In addition, SRNL identified three flammable antifoam degradation products using mass spectrometer (MS) and fourier transform infrared (FTIR) offgas analyzers during simulations. A new antifoam or a new method to control foam is needed to minimize DWPF processing time and reduce the risk of contamination. In addition, testing should be completed to ensure that other antifoams used in HLW processing do not have similar flammability hazards or cause unintended impacts in downstream processing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Proton Nuclear Magnetic Resonance (H NMR) of Glycolate in Real Waste: Developing and Testing Analytical Methods for the Savannah River Site Liquid Waste System

In preparation for implementing the NG acid flowsheet for the SRS LWS, analytical methods for determining glycolate at low concentration are desired to support system management and safety. Previous work documented that the IC method performed well for samples with low to moderate ionic strength. That work also included a scoping effort to determine if an alternate analytical strategy using H NMR would complement and extend the capabilities of the IC method. The H NMR scoping results indicated that the method had the potential to expand glycolate analysis in LWS samples to higher ionic strength tanks/solutions. The scope of this work is to develop innovative proton NMR techniques, including demonstrating ion exchange decontamination protocols needed for application of the technique to real waste samples. Part of radioactive waste processing at SRS uses formic acid to reduce oxidized (Hg 2+ ) to more volatile elemental Hg for steam striping, collecting, and disposal. Under acidic conditions found in the Chemical Processing Cell (CPC) at the Defense Waste Processing Facility (DWPF), formic acid has a much higher hydrogen generation rate than an alternative reductant, glycolic acid. Thus, an NG acid flowsheet has been developed utilizing glycolic acid with the benefit of easing the need for headspace monitoring requirements for hydrogen and ammonia at DWPF. Low concentrations of glycolate are conservatively assumed to be in the recycle stream, which will collect in the Recycle Collection Tank (RCT). The DWPF recycle stream collected in the RCT has a distinct pathway to the LWS waste tanks that feed the 2H and 3H Evaporator. This route involves transfer of the DWPF recycle to Tank 22 in the Concentration, Storage, and Transfer Facilities (CSTF) followed by transfer to the LWS tank farm/evaporators.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modified Isotherm Modeling to Predict Cs Exchange with Crystalline Silicotitanate in Tank Waste Simulants

The U.S. Department of Energy is working to expedite processing of Hanford tank waste supernate at the Hanford Waste Treatment and Immobilization Plant. To support this goal, Washington River Protection Solutions is designing a Tank Side Cesium Removal (TSCR) system for suspended solids and cesium (Cs/ 137 Cs) removal from Hanford tank waste supernate. The ion exchange media selected for Cs removal at TSCR is crystalline silicotitanate (CST) that is manufactured in a nearly spherical form by Honeywell UOP LLC (UOP; Des Plaines, IL) as product IONSIV® R9140-B (Na form). The Zheng Anthony Miller (ZAM) isotherm model (Zheng et al. 1997) is a multicomponent ion exchange model used to predict the exchange of Group I metals onto CST. The ZAM isotherm has historically been used to predict Cs distribution values from Hanford and Savannah River Site (SRS) tank waste simulants. Figure S.1 summarizes model predictions from the ZAM isotherm that indicate poor prediction of Cs distribution values for simple and complex simulants with the engineered form of CST, IONSIV® R9140-B, and IONSIV® R9120-B where the solid line indicates a perfect fit by the model. The dotted lines indicate ±20% error. Batch contact testing with Hanford tank waste complex and simple simulants was used in conjunction with SRS simulants to experimentally determine Cs distribution values using a modification to the original isotherm model. The experimentally determined maximum Cs capacity for IONSIV® R9140-B CST in both the simple and complex matrices was found to be 0.53±0.3 mmoles Cs/g of CST. This value is not drastically different from the maximum Cs capacity of 0.58 mmoles Cs/g TAM-5 reported by Zheng et al. (1997). However, it is important to note that TAM-5 (commercially IONSIV® IE-910) is a powder. Hamm et al. (2002) determined that a dilution factor was needed to account for the Zr(OH)2 binder in the engineered form of CST. Hamm et al. determined that a dilution factor of 0.68 was appropriate to account for binder contribution and correct overprediction of Cs exchange on the engineered form of CST in ZAM calculations. This reduced the total capacity from 0.58 mmol/g with TAM-5 to 0.39 mmol/g for the engineered form of CST (Hamm et al. 2002). Despite substituting the experimentally determined maximum Cs capacity of 0.55 mmoles Cs/g for the literature-reported capacity of 0.39 mmoles Cs/g, it was determined that additional modifications to the model’s equilibrium rate constants were necessary in refining the isotherm model. The modified model overpredicted K+ uptake by the CST when compared to digested CST results described by Campbell et al. (2019). The modified model was further revised to omit three of the five K+ exchange equilibrium reactions described by ZAM to reduce the additional K+ loading seen by the model. Figure S.2 summarizes the revised model isotherm predictions plotted against measured Kd values.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗