Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SIGNAL CONDITIONING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

NW-MILO Acoustic Data Collection

There is an enduring requirement to improve our ability to detect potential threats and discriminate these from the legitimate commercial and recreational activity ongoing in the nearshore/littoral portion of the maritime domain. The Northwest Maritime Information and Littoral Operations (NW-MILO) Program at PNNL’s Coastal Security Institute in Sequim, Washington is establishing a methodology to detect and classify these threats - in part through developing a better understanding of acoustic signatures in a near-shore environment. The purpose of the acoustic data collection described here is to investigate the acoustic signatures of small vessels. The data is being recorded continuously, 24 hours a day, along with radar track data and imagery. The recording began in August 2008, and to date the data contains tens of thousands of signals from small vessels recorded in a variety of environmental conditions. The quantity and variety of this data collection, with the supporting imagery and radar track data, makes it particularly useful for the development of robust acoustic signature models and advanced algorithms for signal classification and information extraction. The underwater acoustic sensing system is part of a multi-modal sensing system that is operating near the mouth of Sequim Bay. Sequim Bay opens onto the Straight of Juan de Fuca, which contains part of the border between the U.S. and Canada. Table 1 lists the specific components used for the NW-MILO system. The acoustic sensor is a hydrophone permanently deployed at a mean depth of about 3 meters. In addition to a hydrophone, the other sensors in the system are a marine radar, an electro-optical (EO) camera and an infra-red (IR) camera. The radar is integrated with a vessel tracking system (VTS) that provides position, speed and heading information. The data from all the sensors is recorded and saved to a central server. The data has been validated in terms of its usability for characterizing the signatures of small vessels. The sampling rate of 8 kHz and low pass filtering to 2 kHz results in an alias-free signal in the frequency band that is appropriate for small vessels. Calibration was performed using a Lubell underwater speaker so that the raw data signal levels can be converted to sound pressure. Background noise is present due to a nearby pump and as a result of tidal currents. More study is needed to fully characterize the noise, but it does not pose an obstacle to using the acoustic data for the purposes of vessel detection and signature analysis. The detection range for a small vessel was estimated using the calibrated voltage response of the system and a cylindrical spreading model for transmission loss. The sound pressure of a typical vessel with an outboard motor was found to be around 140 dB mPa, and could theoretically be detected from 10 km away. In practical terms, a small vessel could reliably be detected from 3 - 5 km away. The data is archived in netCDF files, a standard scientific file format that is "self describing". This means that each data file contains the metadata - timestamps, units, origin, etc. - needed to make the data meaningful and portable. Other file formats, such as XML, are also supported. A visualization tool has been developed to view the acoustic data in the form of spectrograms, along with the coincident radar track data and camera images.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Millimeter-wave generation and characterization of a GaAs FET by optical mixing

Coherent mixing of optical radiation from a tunable continuous-wave dye laser and a stabilized He-Ne laser was used to generate millimeter-wave signals in GaAs FETs attached to printed-circuit millimeter-wave antennas. The generated signal was further down-converted to a 2-GHz IF by an antenna-coupled millimeter-wave local oscillator at 62 GHz. Detailed characterizations of power and S/N under different bias conditions have been performed. This technique is expected to allow signal generation and frequency-response evaluation of millimeter-wave devices at frequencies as high as 100 GHz.

Ni, David C.↗

Thin Sea-Ice Thickness as Inferred from Passive Microwave and In Situ Observations

Since microwave radiometric signals from sea-ice strongly reflect physical conditions of a layer near the ice surface, a relationship of brightness temperature with thickness is possible especially during the early stages of ice growth. Sea ice is most saline during formation stage and as the salinity decreases with time while at the same time the thickness of the sea ice increases, a corresponding change in the dielectric properties and hence the brightness temperature may occur. This study examines the extent to which the relationships of thickness with brightness temperature (and with emissivity) hold for thin sea-ice, approximately less than 0.2 -0.3 m, using near concurrent measurements of sea-ice thickness in the Sea of Okhotsk from a ship and passive microwave brightness temperature data from an over-flying aircraft. The results show that the brightness temperature and emissivity increase with ice thickness for the frequency range of 10-37 GHz. The relationship is more pronounced at lower frequencies and at the horizontal polarization. We also established an empirical relationship between ice thickness and salinity in the layer near the ice surface from a field experiment, which qualitatively support the idea that changes in the near-surface brine characteristics contribute to the observed thickness-brightness temperature/emissivity relationship. Our results suggest that for thin ice, passive microwave radiometric signals contain, ice thickness information which can be utilized in polar process studies.

Naoki, Kazuhiro↗

Time-dependent inhibitory effects of cGMP-analogues on thrombin-induced platelet-derived microparticles formation, platelet aggregation, and P-selectin expression

Highlights: • We investigated the impact of cyclic nucleotide analogues on platelet activation. • Different time dependence were found for inhibition of platelet activation. • Additive effect was found using PKA- and PKG-activating analogues. • Our results may explain some of the discrepancies reported for cNMP signalling. - Abstract: In platelets, nitric oxide (NO) activates cGMP/PKG signalling, whereas prostaglandins and adenosine signal through cAMP/PKA. Cyclic nucleotide signalling has been considered to play an inhibitory role in platelets. However, an early stimulatory effect of NO and cGMP-PKG signalling in low dose agonist-induced platelet activation have recently been suggested. Here, we investigated whether different experimental conditions could explain some of the discrepancy reported for platelet cGMP-PKG-signalling. We treated gel-filtered human platelets with cGMP and cAMP analogues, and used flow cytometric assays to detect low dose thrombin-induced formation of small platelet aggregates, single platelet disappearance (SPD), platelet-derived microparticles (PMP) and thrombin receptor agonist peptide (TRAP)-induced P-selectin expression. All four agonist-induced platelet activation phases were blocked when platelets were costimulated with the PKG activators 8-Br-PET-cGMP or 8-pCPT-cGMP and low-doses of thrombin or TRAP. However, extended incubation with 8-Br-PET-cGMP decreased its inhibition of TRAP-induced P-selectin expression in a time-dependent manner. This effect did not involve desensitisation of PKG or PKA activity, measured as site-specific VASP phosphorylation. Moreover, PKG activators in combination with the PKA activator Sp-5,6-DCL-cBIMPS revealed additive inhibitory effect on TRAP-induced P-selectin expression. Taken together, we found no evidence for a stimulatory role of cGMP/PKG in platelets activation and conclude rather that cGMP/PKG signalling has an important inhibitory function in human platelet activation.

60 APPLIED LIFE SCIENCES↗

Laser Doppler anemometry

The application of laser Doppler anemometry (LDA) to compressible flows is discussed. Specifically, burst-counter and dual-beam LDA systems are addressed. Much has been accomplished with LDA in compressible flows despite the difficulties posed by the high speeds and additionally by the rapid spatial changes in speed or flow direction. The successful application of the technique is difficult because the signal to noise ratios (SNRs) are fairly low even under the best of conditions and highly variable because of variations in particle size and particle location with the sensing volume. The available signal processing is not very effective in discarding signals that are too noisy to provide an accurate velocity measurement. The temptation is to work with particles which are too large to adequately follow the flow but which provide cleaner signals due to increased scattering intensities. For the data to have credibility, some check on the particle response must be made for a given facility and LDA system. The capability, if developed, of being able to determine the size of each particle upon which a measurement is based and the SNR of the corresponding signal burst would be extremely valuable in reducing much of the uncertainty now present in LDA compressible flow measurements.

Johnson, Dennis A.↗

Testing

Testing is conducted to verify that the connectors will properly perform over time (reliability) per the application requirements. Testing by the manufacturer usually involves performance testing per the datasheet requirements. However, the customer may have applications that require performance under unique operational and environmental conditions. In general, electrical tests for connectors include dielectric withstanding voltage, low-signal-level contact resistance, insulation resistance, contact resistance, and standing wave ratio. Environmental tests include humidity, temperature, and contaminating conditions, as well as mechanical stress environments including vibration, mechanical shock, and durability cycling exposures.

Connectors, testing, Dielectric Withstanding Volta↗

Sci—Sat AM: Stereo — 07: Suitability of a plastic scintillator dosimeter for composite clinical fields delivered using the Cyberknife robotic radiosurgery system

Plastic scintillation dosimeters (PSDs) have favourable characteristics for small and composite field dosimetry in radiosurgery, however, imperfect corrections for the Cerenkov radiation contamination could limit their accuracy for complex deliveries. In this work, we characterize the dose and dose-rate linearity, directional dependence, and compare output factors with other stereotactic detectors for a new commercially available PSD (Exradin W1). We provide some preliminary comparisons of planned and measured dose for composite fields delivered clinically by a Cyberknife radiosurgery system. The W1 detector shows good linearity with dose (<0.5%) and dose rate (<0.8%) relative to the signal obtained using an ion chamber under the same conditions. A maximum difference of 2% was observed depending on the detector's angular orientation. Output factors for all detectors agree within a range of ±3.2% and ±1.5% for the 5 and 7.5 mm collimators, respectively, provided Monte-Carlo corrections for detector effects are applied to diode and ion chambers (without corrections the range is ±5.5% and ±3.1% for these two collimators). For clinical beam deliveries using 5 and 7.5 mm collimators, four of the six patients showed better agreement with planned dose for the PSD detector compared to a micro ion chamber. Two of the six patients investigated, however, showed 5% differences between PSD and planned dose, film measurements and the ratio of PSD and micro ion chamber signal suggest that further investigation is warranted for these plans. The W1 detector is a promising tool for stereotactic plan verification under the challenging dosimetric conditions of stereotactic radiosurgery.

60 APPLIED LIFE SCIENCES↗

Necessary and Sufficient Conditions for LTI Representations of Adaptive Systems with Sinusoidal Regressors

This paper establishes necessary and sufficient coneditions for an adaptive system with a sinusoidal regressor (ie., a regressor comprised of sinusoidal signals) to admit an exact linear time-invariant (LTI) representation. These conditions are important because a large number of adaptive systems used in practice have sinusoidal regressors, and the stability, convergence and robustness properties of systems having LTI representations can be completely analyzed by well-known methods.

adaptive↗

Temporal and spatial evolution of runaway electrons at the instability moments in Damavand tokamak

The time and position behavior of runaway electrons at the Parail–Pogutse instability moments has been investigated using experimental observations in plasma current, loop voltage, the Hard X-ray (HXR) radiations, and 18 poloidal pickup coils signals received by data acquisition system simultaneously. The conditional average sampling (CAS) method was used to analyze the output data. Moreover, a filament current code was modified to study the runaway electrons beam movement in the event of instabilities. The results display a rapid drift of runaway beam toward the inner wall of the vacuum vessel and the collision with the wall components at the instability moments. The existence of the collisions in these experiments is evident in the HXR bursts which are considered as the main trigger for CAS Analysis. Also, the variation of HXR bursts with the toroidal magnetic field shows that the hard X-ray bursts drop with increase in the toroidal magnetic field and runaway electrons confinement quality.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Small-Signal Analysis of Current-Limiting Grid-Forming Inverters

Grid-forming (GFM) inverters are equipped with a current limiter to protect the device during grid disturbances. Because the intervention of the current limiter can compromise the transient stability of the GFM inverter, various types of current limiter designs and additional frequency-stabilization control methods have been proposed in recent literature to aid in transient GFM inverter stability; however, the small-signal stability implications of adding these additional control blocks during, in particular, off-nominal conditions are not fully understood. To address this challenge, this paper presents a generic small-signal model of a GFM inverter that incorporates various types of current limiters and frequency stability-enhancing controls. With the proposed model, we analyze the root causes of inverter instability, which reveals two critical design trade-offs. First, due to current-limiter engagement caused by a disturbance, the GFM inverter dynamics are altered, which can lead to voltage oscillations. Second, additional frequency-stabilization controls can improve the small-signal stability of the GFM inverter, but at the cost of reduced power and voltage support to the grid. Comprehensive hardware experiments validate the theoretical concept and analysis. The findings in this work underscore the importance of incorporating both transient-response and small-signal dynamics requirements into the design procedure of GFM current limiters and frequency-stabilization controls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A "Bony" Proposition: Pathways Mediating Responses to Simulated Weightlessness and Radiation

There is evidence that weightlessness and radiation, two elements of the spaceflight environment, can lead to detrimental changes in human musculoskeletal tissue, including bone loss and muscle atrophy. This bone loss is thought to be brought about by the increased activity of bone-resorbing osteoclasts and functional changes in bone-forming osteoblasts, cells that give rise to mature osteocytes. My current area of research focuses on understanding the mechanistic basis for the responses of bone to the spaceflight environment using earth-based animal and cellular models. The overarching goal is to identify molecular targets to prevent bone loss in space exploration and earth-based scenarios of radiotherapy, accidental radiation exposure and reduced mobility. In this talk, I will highlight two signaling pathways that potentially play a role in the response of bone to spaceflight-like conditions. Firstly, I will discuss the role of insulin-like growth factor 1 (IGF1) signaling as it pertains to the recovery of bone from simulated weightlessness (rodent hindlimb unloading model). Secondly, I will share recent findings from our study that aims to understand the emerging role of autophagy in maintaining the balance between bone formation and resorption (bone homeostasis) as well as normal skeletal structure.

autophagy↗

Block 4 receiver tracking loop performance in the presence of a CW RFI

A model that allows one to predict the tracking performance of the Block 4 receiver in the presence of a continuous wave radio frequency interference is discussed. Experimental and analytical results are provided for a typical Deep Space Network operational mode. Simulation and experimental results show good agreement with theoretical prediction for the static phase error and out-of-lock values. Predicted phase jitter is consistently lower than the experimental and simulated results by a factor of one-half for small interference to signal ratio (ISR) when the offset frequency is small. For large ISR, good agreement is observed. The analytical model assumes a noiseless condition, which is valid only when the loop is operated at strong signal levels. Experimental data indicate, however, that even at the minimum operating signal level of 10-dB carrier margin, reasonably good prediction can still be obtained. A curve of protection criteria that extends the current recommendation is also presented.

Sue, M. K.↗

Performance of Integrated Systems of Automated Roller Shade Systems and Daylight Responsive Dimming Systems

Daylight responsive dimming systems have been used in few buildings to date because they require improvements to improve reliability. The key underlying factor contributing to poor performance is the variability of the ratio of the photosensor signal to daylight workplane illuminance in accordance with sun position, sky condition, and fenestration condition. Therefore, this paper describes the integrated systems between automated roller shade systems and daylight responsive dimming systems with an improved closed-loop proportional control algorithm, and the relative performance of the integrated systems and single systems. The concept of the improved closed-loop proportional control algorithm for the integrated systems is to predict the varying correlation of photosensor signal to daylight workplane illuminance according to roller shade height and sky conditions for improvement of the system accuracy. In this study, the performance of the integrated systems with two improved closed-loop proportional control algorithms was compared with that of the current (modified) closed-loop proportional control algorithm. In the results, the average maintenance percentage and the average discrepancies of the target illuminance, as well as the average time under 90percent of target illuminance for the integrated systems significantly improved in comparison with the current closed-loop proportional control algorithm for daylight responsive dimming systems as a single system.

30 DIRECT ENERGY CONVERSION↗

A non-canonical fungal peroxisome PTS-1 signal, SYM, and its evolutionary aspects

Abstract Proteins localized to peroxisomes, particularly those expressed under specific conditions or in low abundance, are often undetected by routine proteomics methods due to detection sensitivity limits. In silico identification and experimental validation of peroxisomal targeting signals (PTSs) offer a reliable alternative. We demonstrate that SYM, a non-canonical plant PTS-1 signal, functions similarly inAspergillus nidulans, as GFP tagged with a SYM C-terminal tripeptide localizes to peroxisomes. One of two nativeA. nidulansproteins with C-terminal SYM tripeptide shows weak peroxisomal localization alongside cytoplasmic presence, indicating that only a subset of proteins with non-canonical signals access peroxisomes.In silicoanalysis of 1,010 fungal genomes identified diverse SYM-proteins with variable functions, suggesting that non-canonical PTS-1 signals may evolve spontaneously. Two-thirds of SYM-proteins are predicted to localize to specific intracellular compartments other than the peroxisome. We propose that despite their predicted localization, these proteins possessing SYM as a non-canonical peroxisomal signal might also have peroxisomal presence. Among SYM-proteins, pectinesterases, known plant pathogen virulence factors, were frequent. Notably, 25% of fungal pectinesterases harbor non-canonical PTS-1 signals, suggesting that partial peroxisomal localization of pectinesterases has evolved convergently. This suggests that partial peroxisomal localization may enhance protein functional flexibility, contributing to the organism’s adaptability.

Science & Technology - Other Topics↗

Revealing the Nano-Scale Structure and Properties of Pinholes in SiOx Layers for POLO Contacts

In this contribution, we report on the charge collection characteristics of silicon photovoltaic devices with passivated contacts based on the c-Si/SiOx /poly-Si structure. Using electron-beam induced current (EBIC) imaging in plan-view and cross-section orientations, we find that charge collection in a device with a 1.5-nm-thick SiOx layer is fairly uniform in the p-n junction region and does not appear to be influenced by pyramidal surface texture. In contrast, a device with a 2.2-nm-thick oxide layer shows significant spatial variation in the charge-collection signal. The locations where we observe preferential collection of excess carriers is very sensitive to the processing conditions used to grow and breakup the SiOx passivation layer. In some cases the apexes of the pyramids exhibit reduced EBIC signal as the valleys between adjacent pyramids show the strongest collection. Other conditions yield enhanced charge collection at well defined spots on pyramid faces with no observable collection in the valleys.

EBIC↗

Optical communication with semiconductor laser diodes

A 25 megabit/sec direct detection optical communication system that used Q=4 PPM signalling was constructed and its performance measured under laboratory conditions. The system used a single-mode AlGaAs laser diode transmitter and low noise silicon avalanche photodiode (APD) photodetector. Comparison of measured performance with the theoretical revealed that modeling the APD output as a Gaussian process under conditions of negligible background radiation and low (less than 10 to the -12 power A) APD bulk leakage currents leads to substantial underestimates of optimal APD gain to use and overestimates of system bit error probability. A procedure is given to numerically compute system performance which uses the more accurate Webb's Approximation of the exact Conradi distribution for the APD ouput signal that does not require excessive amounts of computer time (a few minutes of VAX 8600 CPU time per system operating point). Examples are given which illustrate the breakdown of the Gaussian approximation in assessing system performance. This system achieved a bit error probability of 10 to the -6 power at a received signal energy corresponding to an average of 60 absorbed photons/bit and optimal APD gain of 700.

Davidson, F.↗

Identification of gravitational wave signals from chaotic astrophysical systems through phase space and attractor properties

Phase space and attractor dimensions in a gravitational wave detector output can be estimated in order to identify chaotic (deterministic) signals in the presence of additive Gaussian noise. These quantities are evaluated, respectively, by means of conditional probabilities and the Grassberger-Procaccia algorithm, both methods relying on embedding in a suitable space of dimension d. By testing with different embedding dimensions, a deterministic--though erratic--signal can be detected by comparing the corresponding conditional probabilities via Kolmogorov-Smirnoff test and checking whether the correlation (fractal) dimension differs from d. Results of the two approaches are eventually compared, both for chaotic and periodic trajectories.

79 ASTRONOMY AND ASTROPHYSICS↗

Multipactor theory for multicarrier signals

This work presents a new theory of multipactor under multicarrier signals for parallel-plate geometries, assuming a homogeneous electric field and one-dimensional electron motion. It is the generalization of the nonstationary multipactor theory for single-carrier signals [S. Anza et al.,Phys. Plasmas 17, 062110 (2010)]. It is valid for multicarrier signals with an arbitrary number of carriers with different amplitude, arbitrary frequency, and phase conditions and for any material coating. This new theory is able to model the real dynamics of the electrons during the multipactor discharge for both single and double surface interactions. Among other parameters of the discharge, it calculates the evolution in time of the charge growth, electron absorption, and creation rates as well as the instantaneous secondary emission yield and order. An extensive set of numerical tests with particle-in-cell software has been carried out in order to validate the theory under many different conditions. This theoretical development constitutes the first multipactor theory which completely characterizes the multipactor discharge for arbitrary multicarrier signals, setting the first step for further investigations in the field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗