Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCaN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Spot-Scanning Proton Radiation Therapy for Pediatric Chordoma and Chondrosarcoma: Clinical Outcome of 26 Patients Treated at Paul Scherrer Institute

Purpose: To evaluate the clinical results of fractionated spot-scanning proton radiation therapy (PT) in 26 pediatric patients treated at Paul Scherrer Institute for chordoma (CH) or chondrosarcoma (CS) of the skull base or axial skeleton. Methods and Materials: Between June 2000 and June 2010, 19 CH and 7 CS patients with tumors originating from the skull base (17) and the axial skeleton (9) were treated with PT. Mean age at the time of PT was 13.2 years. The mean prescribed dose was 74 Gy (relative biological effectiveness [RBE]) for CH and 66 Gy (RBE) for CS, at a dose of 1.8-2.0 Gy (RBE) per fraction. Results: Mean follow-up was 46 months. Actuarial 5-year local control (LC) rates were 81% for CH and 80% for CS. Actuarial 5-year overall survival (OS) was 89% for CH and 75% for CS. Two CH patients had local failures: one is alive with evidence of disease, while the other patient succumbed to local recurrence in the surgical pathway. One CS patient died of local progression of the disease. No high-grade late toxicities were observed. Conclusions: Spot-scanning PT for pediatric CH and CS patients resulted in excellent clinical outcomes with acceptable rates of late toxicity. Longer follow-up time and larger cohort are needed to fully assess tumor control and late effects of treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Four-Dimensional Patient Dose Reconstruction for Scanned Ion Beam Therapy of Moving Liver Tumors

Purpose: Estimation of the actual delivered 4-dimensional (4D) dose in treatments of patients with mobile hepatocellular cancer with scanned carbon ion beam therapy. Methods and Materials: Six patients were treated with 4 fractions to a total relative biological effectiveness (RBE)–weighted dose of 40 Gy (RBE) using a single field. Respiratory motion was addressed by dedicated margins and abdominal compression (5 patients) or gating (1 patient). 4D treatment dose reconstructions based on the treatment records and the measured motion monitoring data were performed for the single-fraction dose and a total of 17 fractions. To assess the impact of uncertainties in the temporal correlation between motion trajectory and beam delivery sequence, 3 dose distributions for varying temporal correlation were calculated per fraction. For 3 patients, the total treatment dose was formed from the fractional distributions using all possible combinations. Clinical target volume (CTV) coverage was analyzed using the volumes receiving at least 95% (V{sub 95}) and 107% (V{sub 107}) of the planned doses. Results: 4D dose reconstruction based on daily measured data is possible in a clinical setting. V{sub 95} and V{sub 107} values for the single fractions ranged between 72% and 100%, and 0% and 32%, respectively. The estimated total treatment dose to the CTV exhibited improved and more robust dose coverage (mean V{sub 95} > 87%, SD < 3%) and overdose (mean V{sub 107} < 4%, SD < 3%) with respect to the single-fraction dose for all analyzed patients. Conclusions: A considerable impact of interplay effects on the single-fraction CTV dose was found for most of the analyzed patients. However, due to the fractionated treatment, dose heterogeneities were substantially reduced for the total treatment dose. 4D treatment dose reconstruction for scanned ion beam therapy is technically feasible and may evolve into a valuable tool for dose assessment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reducing Dose Uncertainty for Spot-Scanning Proton Beam Therapy of Moving Tumors by Optimizing the Spot Delivery Sequence

Purpose: To develop and validate a novel delivery strategy for reducing the respiratory motion–induced dose uncertainty of spot-scanning proton therapy. Methods and Materials: The spot delivery sequence was optimized to reduce dose uncertainty. The effectiveness of the delivery sequence optimization was evaluated using measurements and patient simulation. One hundred ninety-one 2-dimensional measurements using different delivery sequences of a single-layer uniform pattern were obtained with a detector array on a 1-dimensional moving platform. Intensity modulated proton therapy plans were generated for 10 lung cancer patients, and dose uncertainties for different delivery sequences were evaluated by simulation. Results: Without delivery sequence optimization, the maximum absolute dose error can be up to 97.2% in a single measurement, whereas the optimized delivery sequence results in a maximum absolute dose error of ≤11.8%. In patient simulation, the optimized delivery sequence reduces the mean of fractional maximum absolute dose error compared with the regular delivery sequence by 3.3% to 10.6% (32.5-68.0% relative reduction) for different patients. Conclusions: Optimizing the delivery sequence can reduce dose uncertainty due to respiratory motion in spot-scanning proton therapy, assuming the 4-dimensional CT is a true representation of the patients' breathing patterns.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prompt Gamma Imaging for In Vivo Range Verification of Pencil Beam Scanning Proton Therapy

Purpose: To report the first clinical results and value assessment of prompt gamma imaging for in vivo proton range verification in pencil beam scanning mode. Methods and Materials: A stand-alone, trolley-mounted, prototype prompt gamma camera utilizing a knife-edge slit collimator design was used to record the prompt gamma signal emitted along the proton tracks during delivery of proton therapy for a brain cancer patient. The recorded prompt gamma depth detection profiles of individual pencil beam spots were compared with the expected profiles simulated from the treatment plan. Results: In 6 treatment fractions recorded over 3 weeks, the mean (± standard deviation) range shifts aggregated over all spots in 9 energy layers were −0.8 ± 1.3 mm for the lateral field, 1.7 ± 0.7 mm for the right-superior-oblique field, and −0.4 ± 0.9 mm for the vertex field. Conclusions: This study demonstrates the feasibility and illustrates the distinctive benefits of prompt gamma imaging in pencil beam scanning treatment mode. Accuracy in range verification was found in this first clinical case to be better than the range uncertainty margin applied in the treatment plan. These first results lay the foundation for additional work toward tighter integration of the system for in vivo proton range verification and quantification of range uncertainties.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of first ever scanning probe microscopy capabilities for plutonium

Scanning probe microscopy capabilities have been developed for plutonium and its derivative compounds. Specifically, a scanning tunneling microscope and an atomic force microscope housed in an ultra-high vacuum system and an inert atmosphere glove box, respectively, were prepared for the introduction of small non-dispersible δ-Pu coupons. Experimental details, procedures, and preliminary imaging of δ-Pu coupons are presented to demonstrate the functionality of these new capabilities. In conclusion, these first of a kind capabilities for plutonium represent a significant step forward in the ability to characterize and understand plutonium surfaces with high spatial resolution.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Intergrowth structure of α-phase in β-type TmAlB{sub 4} compound studied by high-angle annular detector dark-field scanning transmission electron microscopy

Nanostructure of a ThMoB{sub 4}-type (β-type) TmAlB{sub 4} compound, in which YCrB{sub 4}-type (α-type) domains are locally intergrown, is studied by high-angle annular detector dark-field scanning transmission electron microscopy (HAADF-STEM). Z-contrast images by HAADF-STEM directly represent the arrangements of Tm atoms located at centers of heptagonal atomic columns of B atoms as bright dots, and give us detailed information of intergrowth of type domains in the matrix of the β-type phase, which coherently occurs. Structural and bonding analyses for β-TmAlB{sub 4} point out the closeness in atomic interactions and energy of the α- and β-type structures which support the easy formation of such nanostructure intergrowths. From combination between HAADF-STEM and electronic structure calculation, a detailed local crystal structure with intrinsic building defects is effectively revealed. - Graphical abstract: Nanostructure of a ThMoB{sub 4}-type (β-type) TmAlB{sub 4} compound, in which YCrB{sub 4}-type (α-type) domains are locally intergrown, is studied by high-angle annular detector dark-field scanning transmission electron microscopy (HAADF-STEM). Z-contrast images by HAADF-STEM directly represent arrangements of Tm atoms located at centers of heptagonal atomic columns of B atoms as bright dots, and give us detailed information of the characteristic intergrowth structure of type domains in the matrix of the β-type phase. - Highlights: • HAADF-STEM images directly represent arrangements of Tm atoms as bright dots. • The α-type planar domains coherently intergrown in the β-type matrix. • Bright strips appear at overlapped regions of Tm hexagons along interfaces between α- and β-type domains.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of dislocation microstructures in cyclically deformed [001] copper single crystals using high voltage scanning transmission electron microscopy

Highlights: • High voltage scanning transmission electron microscopy is adopted. • Dislocation structure strongly depends on given plastic strain amplitude. • Evolution of dislocation structure from vein-like to labyrinth is revealed. - Abstract: Low-cycle fatigue tests of copper single crystals with the [001] stress axis were performed at room temperature under constant plastic shear strain amplitudes between γ{sub pl} = 3.5 × 10{sup − 4} and 1.0 × 10{sup − 2}. Characteristic dislocation structures, which are highly dependent on a given plastic strain amplitude, were observed by high voltage scanning transmission electron microscopy. A vein-like dislocation structure, having a parallelepiped shape with two longitudinal (100) and (001) sides, was periodically formed along the [010] direction at around γ{sub pl} = 1.0 × 10{sup − 3}. Labyrinth structure with the (100) and (001) dislocation walls was then gradually developed with increasing plastic strain amplitude.

36 MATERIALS SCIENCE↗

Scan strategies in EBM-printed IN718 and the physics of bulk 3D microstructure development

Three-dimensional (3D) characterization provides opportunities for understanding processing-structure relationships in additively manufactured (AM) materials. Bulk samples of Inconel 718 were fabricated via electron beam melting (EBM) in order to study microstructural development as a function of energy input and beam scan strategy. TriBeam tomography of bulk Inconel 718 microstructures built under steady-state growth conditions reveals the sensitivity of microstructure formation and evolution to machine process parameters. Here, samples manufactured using a narrow range of energy input per unit build area result in varied grain morphologies and crystallographic textures. Using TRUCHAS, a thermal simulation software, the thermal history of bulk scan strategies was predicted, and combined with a calibrated microstructure-processing map to accurately predict bulk grain morphologies. The solidification parameters and the 3D measured nucleation density are used to predict the transition between columnar and equiaxed grain morphologies, providing a process map to guide AM parameter choices to locally control as-printed microstructure. A two-dimensional metric for characterizing bulk grain morphology was also found to agree well with predictions from the process map calibrated by 3D data. Combined with 3D tomography and thermal modelling, the physics of structure development were understood at a new level of detail with respect to the competing processes of grain nucleation and epitaxial growth.

36 MATERIALS SCIENCE↗

Scanning transmission election microscopy observations of twisted epitaxial gold nanodiscs in twisted molybdenum disulfide bilayers

Atomic scale, scanning transmission electron microscopy (STEM) analysis of the moiré structures in twisted epitaxial gold nanodiscs encapsulated in twisted bilayer molybdenum disulfide is presented. High angle annular dark field STEM imaging reveals that the period of the moiré patterns between gold and molybdenum disulfide varies with different twist angles of the bilayer molybdenum disulfide, ranging from 1.80 nm (epitaxial alignment of gold) to 1.53 nm (twisted epitaxial alignment of gold). Additionally, bright field STEM imaging reveals a faint, larger "moiré of moiré" structure in cases where the bilayer molybdenum disulfide twist angle is small (~6°), arising from the overlapping three-layers, which is not visible in conventional transmission electron microscopy images. In conclusion, our experiments indicate that scanning transmission electron microscopy as a suitable tool for moiré analysis of twisted multilayer planar heterostructures, complementary to information provided by conventional transmission electron microscopy and diffraction.

Au↗

Build orientation, surface roughness, and scan path influence on the microstructure, mechanical properties, and flexural fatigue behavior of Ti–6Al–4V fabricated by electron beam melting

In the present work, microstructure and fatigue behavior of Electron Beam Melted (EBM) Ti–6Al–4V have been systematically studied. Fatigue behavior was investigated using four-point bend tests of rectangular bars with internal features fabricated with different build orientations, scan paths, and surface conditions. Microstructural variations were evaluated by optical microscopy and Vickers micro-hardness indentations, both of which were found to be consistent throughout the build and within ranges reported in the literature. The fatigue performance of the EBM material was comparable to wrought Ti–6Al–4V when the loading direction was parallel to the build direction, but severely limited when loaded perpendicular to the build direction or if surface roughness defects were present. Scanning electron microscopy and interrupted fatigue tests were utilized to characterize fracture surfaces, failure mechanisms, crack initiation, and propagation behavior. Crack initiation sites in the vertically-oriented specimens were identified to be melt-related defects formed by insufficient melting.

36 MATERIALS SCIENCE↗

Cepstral scanning transmission electron microscopy imaging of severe lattice distortions

The development of four-dimensional (4D) scanning transmission electron microscopy (STEM) using fast detectors has opened-up new avenues for addressing some of longstanding challenges in electron imaging. One of these challenges is how to image severely distorted crystal lattices, such as at a dislocation core. Here we develop a new 4D-STEM technique, called Cepstral STEM, for imaging disordered crystals using electron diffuse scattering. In contrast to analysis based on Bragg diffraction, which measures the average and periodic scattering potential, electron diffuse scattering can detect fluctuations caused by crystal disorder. Local fluctuations of diffuse scattering are captured by scanning electron nanodiffraction (SEND) using a coherent probe. The harmonic signals in electron diffuse scattering are detected through Cepstral analysis and used for imaging. By integrating Cepstral analysis with 4D-STEM, we demonstrate that information about the distortive part of electron scattering potential can be separated and imaged at nm spatial resolution. Here, we apply the technique to the analysis of a dislocation core in SiGe and lattice distortions in a high entropy alloy.

36 MATERIALS SCIENCE↗

Microwave Frequency Comb from a Semiconductor in a Scanning Tunneling Microscope

Abstract Quasi-periodic excitation of the tunneling junction in a scanning tunneling microscope, by a mode-locked ultrafast laser, superimposes a regular sequence of 15 fs pulses on the DC tunneling current. In the frequency domain, this is a frequency comb with harmonics at integer multiples of the laser pulse repetition frequency. With a gold sample the 200th harmonic at 14.85 GHz has a signal-to-noise ratio of 25 dB, and the power at each harmonic varies inversely with the square of the frequency. Now we report the first measurements with a semiconductor where the laser photon energy must be less than the bandgap energy of the semiconductor; the microwave frequency comb must be measured within 200 μ m of the tunneling junction; and the microwave power is 25 dB below that with a metal sample and falls off more rapidly at the higher harmonics. Our results suggest that the measured attenuation of the microwave harmonics is sensitive to the semiconductor spreading resistance within 1 nm of the tunneling junction. This approach may enable sub-nanometer carrier profiling of semiconductors without requiring the diamond nanoprobes in scanning spreading resistance microscopy.

Material Science↗

Controlled-Resonant Surface Tapping-Mode Scanning Probe Electrospray Ionization Mass Spectrometry Imaging

This paper reports on the advancement of a controlled-resonance surface tapping-mode single capillary liquid junction extraction/ESI emitter for mass spectrometry imaging. The basic instrumental setup and the general operation of the system were discussed and optimized performance metrics were presented. The ability to spot sample, lane scan and chemically image in an automated and controlled fashion were demonstrated. Rapid, automated spot sampling was demonstrated for a variety of compound types including the cationic dye basic blue 7, the oligosaccharide cellopentaose, and the protein equine heart cytochrome c. The system was used for lane scanning and chemical imaging of the cationic dye crystal violet in inked lines on glass and for lipid distributions in mouse brain thin tissue sections. Imaging of the lipids in mouse brain tissue under optimized conditions provided a spatial resolution of approximately 35 m based on the ability to distinguish between features observed both in the optical and mass spectral chemical images. The sampling spatial resolution of this system was comparable to the best resolution that has been reported for other types of atmospheric pressure liquid extraction-based surface sampling/ionization techniques used for mass spectrometry imaging.

Lorenz, Matthias↗

Photoemission electron microscopy and scanning electron microscopy of Magnetospirillum magnetotacticum ’s magnetosome chains

Magnetotactic bacteria are of great interdisciplinary interest, since a vast field of applications from magnetic recording media to medical nanorobots is conceivable. A key feature for a further understanding is the detailed knowledge about the magnetosome chain within the bacteria. We report on two preparation procedures suitable for UHV experiments in reflective geometry. Further, we present the results of scanning electron microscopy, as well as the first photoemission electron microscopy experiments, both accessing the magnetosomes within intact magnetotactic bacteria and compare these to scanning electron microscopy data from the literature. From the images, we can clearly identify individual magnetosomes within their chains.

Keutner, Christoph↗

Nanofocused Scanning X-ray Fluorescence Microscopy Revealing an Effect of Heterozygous Hemoglobin S and C on Biochemical Activities in Plasmodium falciparum -Infected Erythrocytes

While there is ample evidence suggesting that carriers of heterozygous hemoglobin S and C are protected from life-threatening malaria, little is known about the underlying biochemical mechanisms at the single cell level. In this work, using nanofocused scanning X-ray fluorescence microscopy, we quantify the spatial distribution of individual elements in subcellular compartments, including Fe, S, P, Zn, and Cu, in Plasmodium falciparum -infected ( P. falciparum -infected) erythrocytes carrying the wild type or variant hemoglobins. Our data indicate that heterozygous hemoglobin S and C significantly modulate biochemical reactions in parasitized erythrocytes, such as aberrant hemozoin mineralization and a delay in hemoglobin degradation. The label-free scanning X-ray fluorescence imaging has great potential to quantify the spatial distribution of elements in subcellular compartments of P. falciparum -infected erythrocytes and unravel the biochemical mechanisms underpinning disease and protective traits.

59 BASIC BIOLOGICAL SCIENCES↗

Studying Catalytically Viable Single-Crystalline Metal Oxide Nanorods Using Synchrotron-Based Scanning Hard X-ray Microscopy

Synchrotron-based scanning hard X-ray microscopy (SHXM) was used to extract localized chemical and structural information within a system of model alkaline earth-metal tungstate nanorods, characterized by multiple chemical configurations. Specifically, we have highlighted the practical ability of SHXM to probe chemically distinctive nanoscale species, consisting of (i) chemically doped versus (ii) solid solution-state nanorods of comparable dimension, synthesized using a template-directed method under ambient conditions. Indeed, we show that SHXM can be used to map out elemental distributions within individual anisotropic nanorods with nanoscale resolution, coupled with chemical sensitivity and specificity. Complementary electrochemical results suggest the possibility of using these nanorods as support materials for electro-oxidation reactions within an acidic electrolyte medium. Our structural and chemical composition results have been corroborated using parallel lines of inquiry involving scanning electron microscopy, transmission electron microscopy, energy-dispersive X-ray spectroscopy, X-ray diffraction, and X-ray photoelectron spectroscopy. Furthermore, these measurements confirmed the relatively even and uniform distribution of the expected, individual elements within all of the nanorod samples tested.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Probing Light Atoms at Subnanometer Resolution: Realization of Scanning Transmission Electron Microscope Holography

Atomic resolution imaging of light elements in electron-transparent materials has long been a challenge. Biomolecular materials, for example, are rapidly altered by incident electrons. We demonstrate a scanning transmission electron microscopy (STEM) technique, called STEM holography, capable of efficient structural analysis of beam-sensitive nanomaterials. STEM holography measures the absolute phase and amplitude of electrons passed through a specimen via interference with a vacuum reference wave. We use an amplitude-dividing nanofabricated grating to prepare multiple beams focused at the sample. We configure the postspecimen microscope imaging system to overlap the beams, forming an interference pattern. We record and analyze the pattern at each 2D-raster-scan-position, reconstructing the complex object wave. As a demonstration, we image gold nanoparticles on an amorphous carbon substrate at 2.4 Å resolution. In conclusion STEM holography offers higher contrast of the carbon while maintaining gold atomic lattice resolution compared to high angle annular dark field STEM.

4D-STEM↗

Lattice Strain Measurement of Core@Shell Electrocatalysts with 4D Scanning Transmission Electron Microscopy Nanobeam Electron Diffraction

Strain engineering enables the direct modification of atomic bonding and is currently an active area of research aimed at improving electrocatalytic activity. However, directly measuring the lattice strain of individual catalyst nanoparticles is challenging, especially at the scale of a single unit cell. In this study, we quantitatively map the strain present in rhodium@platinum (core@shell) nanocube electrocatalysts using conventional aberration-corrected scanning transmission electron microscopy (STEM) and the recently developed technique of 4D-STEM nanobeam electron diffraction. We demonstrate that 4D-STEM combined with data preconditioning allows for quantitative lattice strain mapping with subpicometer precision and without the influence of scan distortions. When combined with multivariate curve resolution, 4D-STEM allows us to distinguish the nanocube core from the shell and to quantify the unit cell size as a function of distance from the core–shell interface. Our results demonstrate that 4D-STEM has significant precision and accuracy advantages in strain metrology of catalyst materials compared to aberration-corrected STEM imaging and is beneficial for extracting information about the evolution of strain in catalyst nanoparticles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗