Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCINTILLATIONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Crystal structure, electronic structure, temperature-dependent optical and scintillation properties of CsCe 2 Br 7

CsCe 2 Br 7 is a self-activated inorganic scintillator that shows promising performance, but the understanding of the important structure-property relationships is lacking. In this work, we conduct a comprehensive study on CCsCe 2 Br 7 . The crystal structure of CsCe 2 Br 7 is refined using single crystal X-ray study for the first time. It crystallizes into the orthorhombic crystal system with Pmnb space group. Its electronic structure is revealed by Density Functional Theory (DFT) calculations. Two cerium emission centers are identified and the energy barriers related to the thermal quenching to 4f ground states of Ce 3+ for these two Ce centers are evaluated. CsCe 2 Br 7 single crystal has better light yield and energy resolution than CsCe 2 Cl 7 , but with an additional slow decay component of 1.7 s. The existence of a deep trap with a depth of 0.9 eV in CsCe 2 Cl 7 contributes to its higher afterglow level in comparison to that of CsCe 2 Br 7 . The most possible point defects in CsCe 2 Cl 7 and CsCe 2 Br 7 are proposed by considering the vapour pressure in the growth atmosphere upon melting point.

36 MATERIALS SCIENCE↗

Optical scattering lengths in large liquid-scintillator neutrino detectors

For liquid-scintillator neutrino detectors of kiloton scale, the transparency of the organic solvent is of central importance. The present paper reports on laboratory measurements of the optical scattering lengths of the organic solvents phenylxylylethane, linear alkylbenzene (LAB), and dodecane, which are under discussion for next-generation experiments such as SNO+ (Sudbury Neutrino Observatory), HanoHano, or LENA (Low Energy Neutrino Astronomy). Results comprise the wavelength range of 415-440 nm. The contributions from Rayleigh and Mie scattering as well as from absorption/re-emission processes are discussed. Based on the present results, LAB seems to be the preferred solvent for a large-volume detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a thermal neutron detector based on scintillating fibers and silicon photomultipliers

We propose a technique for thermal neutron detection, based on a {sup 6}Li converter placed in front of scintillating fibers readout by means of silicon photomultipliers. Such a technique allows building cheap and compact detectors and dosimeters, thus possibly opening new perspectives in terms of granular monitoring of neutron fluxes as well as space-resolved neutron detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy resolution of gamma-ray spectroscopy of JET plasmas with a LaBr{sub 3} scintillator detector and digital data acquisition

A new high efficiency, high resolution, fast {gamma}-ray spectrometer was recently installed at the JET tokamak. The spectrometer is based on a LaBr{sub 3}(Ce) scintillator coupled to a photomultiplier tube. A digital data acquisition system is used to allow spectrometry with event rates in excess of 1 MHz expected in future JET DT plasmas. However, at the lower rates typical of present day experiments, digitization can degrade the energy resolution of the system, depending on the algorithms used for extracting pulse height information from the digitized pulses. In this paper, the digital and analog spectrometry methods were compared for different experimental conditions. An algorithm based on pulse shape fitting was developed, providing energy resolution equivalent to the traditional analog spectrometry method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Near midplane scintillator-based fast ion loss detector on DIII-D

A new scintillator-based fast-ion loss detector (FILD) installed near the outer midplane of the plasma has been commissioned on DIII-D. This detector successfully measures coherent fast ion losses produced by fast-ion driven instabilities ({<=}500 kHz). Combined with the first FILD at {approx}45 Degree-Sign below the outer midplane [R. K. Fisher, et al., Rev. Sci. Instrum. 81, 10D307 (2010)], the two-detector system measures poloidal variation of losses. The phase space sensitivity of the new detector (gyroradius r{sub L}{approx}[1.5-8] cm and pitch angle {alpha}{approx}[35 Degree-Sign -85 Degree-Sign ]) is calibrated using neutral beam first orbit loss measurements. Since fast ion losses are localized poloidally, having two FILDs at different poloidal locations allows for the study of losses over a wider range of plasma shapes and types of loss orbits.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a fast scintillator based beam phase measurement system for compact superconducting cyclotrons

In an isochronous cyclotron, measurements of central phase of the ion beam with respect to rf and the phase width provide a way to tune the cyclotron for maximum energy gain per turn and efficient extraction. We report here the development of a phase measurement system and the measurements carried out at the Variable Energy Cyclotron Centre's (VECC's) K= 500 superconducting cyclotron. The technique comprises detecting prompt {gamma}-rays resulting from the interaction of cyclotron ion beam with an aluminium target mounted on a radial probe in coincidence with cyclotron rf. An assembly comprising a fast scintillator and a liquid light-guide inserted inside the cyclotron was used to detect the {gamma}-rays and to transfer the light signal outside the cyclotron where a matching photo-multiplier tube was used for light to electrical signal conversion. The typical beam intensity for this measurement was a few times 10{sup 11} pps.

43 PARTICLE ACCELERATORS↗

Development of radiopure cadmium tungstate crystal scintillators from enriched {sup 106}Cd and {sup 116}Cd to search for double beta decay

Cadmium tungstate crystal scintillators enriched in {sup 106}Cd up to 66% ({sup 106}CdWO{sub 4}) and in {sup 116}Cd up to 82% ({sup 116}CdWO{sub 4}) have been developed. The low radioactive contamination of the crystals measured on the level of ≤ 1.5 mBq/kg ({sup 40}K), ≤ 0.005 - 0.012 mBq/kg ({sup 226}Ra), 0.04 - 0.07 mBq/kg ({sup 228}Th) allows to carry out high sensitivity experiments to search for double beta processes in {sup 106}Cd and {sup 116}Cd.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Origin of improved scintillation efficiency in (Lu,Gd){sub 3}(Ga,Al){sub 5}O{sub 12}:Ce multicomponent garnets: An X-ray absorption near edge spectroscopy study

In the recent successful improvement of scintillation efficiency in Lu{sub 3}Al{sub 5}O{sub 12}:Ce driven by Ga{sup 3+} and Gd{sup 3+} admixture, the “band-gap engineering” and energy level positioning have been considered the valid strategies so far. This study revealed that this improvement was also associated with the cerium valence instability along with the changes of chemical composition. By utilizing X-ray absorption near edge spectroscopy technique, tuning the Ce{sup 3+}/Ce{sup 4+} ratio by Ga{sup 3+} admixture was evidenced, while it was kept nearly stable with the Gd{sup 3+} admixture. Ce valence instability and Ce{sup 3+}/Ce{sup 4+} ratio in multicomponent garnets can be driven by the energy separation between 4f ground state of Ce{sup 3+} and Fermi level.

36 MATERIALS SCIENCE↗

Taheri-Saramad x-ray detector (TSXD): A novel high spatial resolution x-ray imager based on ZnO nano scintillator wires in polycarbonate membrane

A novel x-ray imager based on ZnO nanowires is designed and fabricated. The proposed architecture is based on scintillation properties of ZnO nanostructures in a polycarbonate track-etched membrane. Because of higher refractive index of ZnO nanowire compared to the membrane, the nanowire acts as an optical fiber that prevents the generated optical photons to spread inside the detector. This effect improves the spatial resolution of the imager. The detection quantum efficiency and spatial resolution of the fabricated imager are 11% and <6.8 μm, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of liquid scintillation detector (BC-501A) and digital pulse shape discrimination (DPSD) system

A digital n/γ pulse shape discrimination (PSD) system is currently under development at Instrumentation and Automation Centre, Malaysian Nuclear Agency. This system aims at simultaneous detection of fast neutron and gamma ray in mixed radiations environment. This work reports the system characterization performed on the liquid scintillation detector (BC-501A) and digital pulse shape discrimination (DPSD) system. The characterization involves measurement of electron light output from the BC-501A detector and energy channels calibration of the pulse height spectra acquired with DPSD system using set of photon reference sources. The main goal of this experiment is to calibrate the ADC channel of our DPSD system, characterized the BC-501 detector and find the position of Compton edge which later could be used as threshold for the n/γ PSD experiment. The detector resolution however is worse as compared to other published data but it is expected as our detector has a smaller active volume.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The response of a fast scintillator screen (YAP:Ce) to low energy ions (0-40 keV) and its use to detect fast-ion-loss in stellarator TJ-II

A systematic study of scintillation materials was undertaken to improve the time resolution of the fast ion diagnostic currently installed at TJ-II stellarator. It was found that YAP:Ce (formula YAlO{sub 3}:Ce, Yttrium Aluminum Perovskite doped with Cerium) ionoluminescence offers better sensitivity and time response compared to the standard detector material, SrGa{sub 2}S{sub 4}:Eu (TG-Green), currently used in TJ-II. A comparison between both materials was carried out by irradiating them with H{sup +} ions of up to 40 keV using a dedicated laboratory setup. It is found that for the low energy ions of interest at TJ-II, YAP:Ce offers 20 times higher sensitivity than TG-Green and much faster decay time, 27 ns versus 540 ns. It is expected that the use of YAP:Ce in combination with a faster data acquisition and an ion counting software as part of the TJ-II ion luminescent probe will provide 20 times faster data on ion loss.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CONSTRAINING THE VELA PULSAR'S RADIO EMISSION REGION USING NYQUIST-LIMITED SCINTILLATION STATISTICS

Using a novel technique, we achieve {approx}100 picoarcsec resolution and set an upper bound of less than 4 km for the characteristic size of the Vela pulsar's emission region. Specifically, we analyze flux-density statistics of the Vela pulsar at 760 MHz. Because the pulsar exhibits strong diffractive scintillation, these statistics convey information about the spatial extent of the radio emission region. We measure both a characteristic size of the emission region and the emission sizes for individual pulses. Our results imply that the radio emission altitude for the Vela pulsar at this frequency is less than 340 km.

79 ASTRONOMY AND ASTROPHYSICS↗

Interstellar scintillation of the double pulsar J0737–3039

We report a series of observations of the interstellar scintillation (ISS) of the double pulsar J0737–3039 over the course of 18 months. As in earlier work, the basic phenomenon is the variation in the ISS caused by the changing transverse velocities of each pulsar, the ionized interstellar medium (IISM), and the Earth. The transverse velocity of the binary system can be determined both by very long baseline interferometry and timing observations. The orbital velocity and inclination is almost completely determined from timing observations, but the direction of the orbital angular momentum is not known. Since the Earth's velocity is known, and can be compared with the orbital velocity by its effect on the timescale of the ISS, we can determine the orientation Ω of the pulsar orbit with respect to equatorial coordinates (Ω = 65 ± 2°). We also resolve the ambiguity (i = 88.°7 or 91.°3) in the inclination of the orbit deduced from the measured Shapiro delay by our estimate i = 88.°1 ± 0.°5. This relies on the analysis of the ISS over both frequency and time, and provides a model for the location, anisotropy, turbulence level, and transverse phase gradient of the IISM. We find that the IISM can be well-modeled during each observation, typically of a few orbital periods, but its turbulence level and mean velocity vary significantly over the 18 months.

79 ASTRONOMY AND ASTROPHYSICS↗

Material identification in x-ray microscopy and micro CT using multi-layer, multi-color scintillation detectors

We demonstrate that a dual-layer, dual-color scintillator construct for microscopic CT, originally proposed to increase sensitivity in synchrotron imaging, can also be used to perform material quantification and classification when coupled with polychromatic illumination. We consider two different approaches to data handling: (1) a data-domain material decomposition whose estimation performance can be characterized by the Cramer-Rao lower bound formalism but which requires careful calibration and (2) an image-domain material classification approach that is more robust to calibration errors. The data-domain analysis indicates that useful levels of SNR (>5) could be achieved in one second or less at typical bending magnet fluxes for relatively large amounts of contrast (several mm path length, such as in a fluid flow experiment) and at typical undulator fluxes for small amount of contrast (tens of microns path length, such as an angiography experiment). The tools introduced could of course be used to study and optimize parameters for a wider range of potential applications. The image domain approach was analyzed in terms of its ability to distinguish different elemental stains by characterizing the angle between the lines traced out in a two-dimensional space of effective attenuation coefficient in the front and back layer images. As a result, this approach was implemented at a synchrotron and the results were consistent with simulation predictions.

36 MATERIALS SCIENCE↗

Characterization and Modeling of a Water-based Liquid Scintillator

We characterised Water-based Liquid Scintillator (WbLS) using low energy protons, UV-VIS absorbance, and fluorescence spectroscopy. We have also developed and validated a simulation model that describes the behaviour of WbLS in our detector configurations for proton beam energies of 210 MeV, 475 MeV, and 2 GeV and for two WbLS compositions. These results have enabled us to estimate the light yield and ionisation quenching of WbLS, as well as to understand the influence of the wavelength shifting of Cherenkov light on our measurements. These results are relevant to the suitability of WbLS materials for next generation intensity frontier experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Near-infrared scintillation of liquid argon: recent results obtained with the NIR facility at Fermilab

After a short review of previous attempts to observe and measure the near-infrared scintillation in liquid argon, we present new results obtained with NIR, a dedicated cryostat at the Fermilab Proton Assembly Building (PAB). Lastly, the new results give confidence that the near-infrared light can be used as the much needed light signal in large liquid argon time projection chambers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Doping liquid argon with xenon in ProtoDUNE Single-Phase: effects on scintillation light

Doping of liquid argon TPCs (LArTPCs) with a small concentration of xenon is a technique for light-shifting and facilitates the detection of the liquid argon scintillation light. In this paper, we present the results of the first doping test ever performed in a kiloton-scale LArTPC. From February to May 2020, we carried out this special run in the single-phase DUNE Far Detector prototype (ProtoDUNE-SP) at CERN, featuring 720 t of total liquid argon mass with 410 t of fiducial mass. A 5.4 ppm nitrogen contamination was present during the xenon doping campaign. The goal of the run was to measure the light and charge response of the detector to the addition of xenon, up to a concentration of 18.8 ppm. The main purpose was to test the possibility for reduction of non-uniformities in light collection, caused by deployment of photon detectors only within the anode planes. Light collection was analysed as a function of the xenon concentration, by using the pre-existing photon detection system (PDS) of ProtoDUNE-SP and an additional smaller set-up installed specifically for this run. In this paper we first summarize our current understanding of the argon-xenon energy transfer process and the impact of the presence of nitrogen in argon with and without xenon dopant. We then describe the key elements of ProtoDUNE-SP and the injection method deployed. Two dedicated photon detectors were able to collect the light produced by xenon and the total light. The ratio of these components was measured to be about 0.65 as 18.8 ppm of xenon were injected. We performed studies of the collection efficiency as a function of the distance between tracks and light detectors, demonstrating enhanced uniformity of response for the anode-mounted PDS. We also show that xenon doping can substantially recover light losses due to contamination of the liquid argon by nitrogen.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THREE-DIMENSIONAL RECONSTRUCTIONS AND MASS DETERMINATION OF THE 2008 JUNE 2 LASCO CORONAL MASS EJECTION USING STELab INTERPLANETARY SCINTILLATION OBSERVATIONS

We examine and reconstruct the interplanetary coronal mass ejection (ICME) first seen in space-based coronagraph white-light difference images on 2008 June 1 and 2. We use observations of interplanetary scintillation (IPS) taken with the Solar-Terrestrial Environment Laboratory (STELab), Japan, in our three-dimensional (3D) tomographic reconstruction of density and velocity. The coronal mass ejection (CME) was first observed by the LASCO C3 instrument at around 04:17 UT on 2008 June 2. Its motion subsequently moved across the C3 field of view with a plane-of-the-sky velocity of 192 km s{sup -1}. The 3D reconstructed ICME is consistent with the trajectory and extent of the CME measurements taken from the CDAW CME catalog. However, excess mass estimates vary by an order of magnitude from Solar and Heliospheric Observatory and Solar Terrestrial Relations Observatory coronagraphs to our 3D IPS reconstructions of the inner heliosphere. We discuss the discrepancies and give possible explanations for these differences as well as give an outline for future studies.

79 ASTRONOMY AND ASTROPHYSICS↗