Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Retrofitting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Assessment of Building Energy-Saving Policies and Programs in China During the 11th Five Year Plan

China's 11th Five-Year Plan (FYP) sets an ambitious target to reduce the energy intensity per unit of gross domestic product (GDP) by 20% from 2005 to 2010 (NDRC, 2006). In the building sector, the primary energy-saving target allocated during the 11 FYP period is 100 Mtce. Savings are expected to be achieved through the strengthening of enforcement of building energy efficiency codes, existing building retrofits and heat supply system reform, followed by energy management of government office buildings and large scale public buildings, adoption of renewable energy sources. To date, China has reported that it achieved the half of the 20% intensity reduction target by the end of 2008, however, little has been made clear on the status and the impact of the building programs. There has also been lack of description on methodology for calculating the savings and baseline definition, and no total savings that have been officially reported to date. This paper intends to provide both quantitative and qualitative assessment of the key policies and programs in building sector that China has instituted in its quest to fulfill the national goal. Overall, this paper concludes that the largest improvement for building energy efficiency were achieved in new buildings; the program to improve the energy management in government and large scale public buildings are in line with the target; however the progress in the area of existing building retrofits, particularly heating supply system reform lags behind the stated goal by a large amount.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Final Expert Meeting Report: Simplified Space Conditioning Strategies for Energy Efficient Houses

More research is needed to evaluate the level of energy efficiency and the conditions where simplified space conditioning systems will work in new and retrofitted houses. Guidance is needed on the design and installation of these systems to support a wider adoption throughout the new construction and retrofit market. The purpose of this expert meeting was to recap the current state of knowledgein this area and to provide a peer review of IBACOS's research plan for new and existing unoccupied test houses with minimized space conditioning systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization of Oxy-combustion Impacts in Existing Coal-fired Boilers

This report summarizes Year 2 results of a research program designed to use multi-scale experimental studies and fundamental theoretical models to characterize and predict the impacts of retrofit of existing coal-fired utility boilers for oxy-combustion. Year 2 focused extensively on obtaining experimental data from the bench-scale, lab-scale and pilot-scale reactors. These data will be used to refine and validate submodels to be implemented in CFD simulations of full-scale boiler retrofits. Program tasks are on schedule for Year 3 completion. Both Year 2 milestones were completed on schedule and within budget.

01 COAL, LIGNITE, AND PEAT↗

Transforming Existing Buildings through New Media: An Idea Exchange (Expert Meeting Report)

This report describes results of a Building America expert meeting on September 13, 2011, in Las Vegas, Nevada, hosted by the Building America Retrofit Alliance (BARA). This meeting provided a forum for presentations and discussions on the use of new media to work with remodelers and retrofit projects to improve energy efficiency and deliver research results from the Building America program toremodelers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Savings and Green Initiatives Project Grant

This project entails retrofitting all four foot, 2, 3 and 4 bulb 40 watt T12 fixtures to T8 28 watt and 150 watt incandescent to 26 watt compact fluorescent bulbs. In total, 2,086 fixtures will be retrofitted.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Strategy Guideline: Proper Water Heater Selection

This Strategy Guideline on proper water heater selection has been developed to provide step-by-step procedures for evaluating preferred cost-effective options for energy efficient water heater alternatives based on local utility rates, climate, and anticipated loads. These procedures, developed both for individual water heater applications (both single and multi-family) and multifamily central systems, provide users with projections on operating cost savings over a 10- year time horizon for retrofit applications and on a cash flow basis for new construction. The savings information, combined with installation cost estimates, allows one to determine which alternatives make sense for a particular application. The information presented in this guideline is based on latest monitoring results from residential field assessments of advanced gas water heater systems and heat pump water heater (HPWH) systems. The methodology presented here can be further refined as more data becomes available on emerging water heating technologies. The tool is targeted at both single and multifamily new and retrofit applications. The intended audience includes: • Builders and Building Owners • Plumbers • General Contractors • Homeowners. This guideline fills an important need because it moves beyond a simplified approach of comparing alternative water heating systems based on a single performance metric. By recognizing the load variations on equipment performance, climate differences, and retail fuel rates, one can develop a more customized performance assessment of competing technologies. This guideline represents the first step in the process of developing a comprehensive system-based evaluation of optimal water heater system design, which will hopefully be developed in the near future. Other Building America-sponsored activities will lead to measure guidelines that focus on technology-specific implementation details related to installation issues in new and existing homes. These guidelines will address issues related to combustion air, venting requirements, space conditioning impacts, safety issues, and other implementation details. The CARB team has developed such a guideline on HPWHs, entitled “Heat Pump Water Heaters in New and Existing Homes”, and IBACOS is in the process of finalizing a tankless water heater guideline.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measure Guideline: High Efficiency Natural Gas Furnaces

This Measure Guideline covers installation of high-efficiency gas furnaces. Topics covered include when to install a high-efficiency gas furnace as a retrofit measure, how to identify and address risks, and the steps to be used in the selection and installation process. The guideline is written for Building America practitioners and HVAC contractors and installers. It includes a compilation ofinformation provided by manufacturers, researchers, and the Department of Energy as well as recent research results from the Partnership for Advanced Residential Retrofit (PARR) Building America team.

03 NATURAL GAS↗

The impact of energy efficiency program information and incentives

Residential retrofits are widely viewed as a key resource to improve the national economy and strengthen the nation’s energy future by saving homeowners money, creating local jobs, and reducing building energy consumption. However, there has been only limited success in engaging large numbers of homeowners to pursue comprehensive home energy improvements. To increase the market penetration of home retrofits, national programs like the Department of Energy's Home Energy Score (HEScore), and local programs like the Kentucky Home Partnership (KHP), have recently been developed. When successfully deployed with existing energy efficiency programs such as the Tennessee Valley Authority's (TVA) In-Home Energy Evaluation (IHEE), national energy efficiency goals that once seemed unattainable may now be within reach.

Jackson, Roderick K.↗

Addendum to the Building America House Simulation Protocols

As Building America (BA) has grown to include a large and diverse cross-section of the home building and retrofit industries, it has become more important to develop accurate, consistent analysis techniques to measure progress towards the program's goals. The House Simulation Protocols (HSP) provides guidance to program partners and managers so that energy savings for new construction and retrofit projects can be compared alongside each other. The HSP provides the program with analysis methods that are proven to be effective and reliable in investigating the energy use of advanced energy systems and of entire houses.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technical Feasibility Assessment of LED Roadway Lighting on the Golden Gate Bridge

Subsequent to preliminary investigations by the Golden Gate Bridge Highway & Transportation District (GGB), in coordination with Pacific Gas & Electric (PG&E), the GATEWAY Demonstration program was asked to evaluate the technical feasibility of replacing existing roadway lighting on the bridge with products utilizing LED technology. GGB and PG&E also indicated interest in induction (i.e., electrodeless fluorescent) technology, since both light source types feature rated lifetimes significantly exceeding those of the existing high-pressure sodium (HPS) and low-pressure sodium (LPS) products. The goal of the study was to identify any solutions which would reduce energy use and maintenance without compromising the quantity or quality of existing illumination. Products used for roadway lighting on the historic bridge must be installed within the existing amber-lensed shoebox-style luminaire housings. It was determined that induction technology does not appear to represent a viable alternative for the roadway luminaires in this application; any energy savings would be attributable to a reduction in light levels. Although no suitable LED retrofit kits were identified for installation within existing luminaire housings, several complete LED luminaires were found to offer energy savings of 6-18%, suggesting custom LED retrofit kits could be developed to match or exceed the performance of the existing shoeboxes. Luminaires utilizing ceramic metal halide (CMH) were also evaluated, and some were found to offer 28% energy savings, but these products might actually increase maintenance due to the shorter rated lamp life. Plasma technology was evaluated, as well, but no suitable products were identified. Analysis provided in this report was completed in May 2012. Although LED technologies are expected to become increasingly viable over time, and product mock-ups may reveal near-term solutions, some options not currently considered by GGB may ultimately merit evaluation. For example, it would be preferable in terms of performance to simply replace existing luminaires (some of which may already be nearing end of life) with fully-integrated LED or CMH luminaires rather than replacing internal components. Among other benefits, this would allow reputable manufacturers to offer standard warranties for their products. Similarly, the amber lenses might be reformulated such that they do not render white light sources in a greenish cast, thereby allowing the use of off-the-shelf LED or CMH products. Last, it should be noted that the existing amber-lensed shoeboxes bear no daytime resemblance to the LPS luminaires originally used to light the roadway.

ceramic metal halide↗

Reducing Thermal Losses and Gains With Buried and Encapsulated Ducts in Hot-Humid Climates

Thermal losses and gains from ductwork installed in unconditioned spaces—such as attics, crawl spaces, and garages—can contribute significantly to the overall heating and cooling loads of single-family residential buildings, with estimated duct losses ranging from 10%–45 %. The impact is particularly severe in hot climates where air conditioning dominates and extensive duct systems are typically located in hot attics. The duct system inefficiencies are greatest at peak demand conditions when the attic is hottest and run times are the highest. The thermal losses and gains at the three single-story houses in Florida monitored in this study accounted for 15%–35% of the annual pre-retrofit heating and cooling energy use and 6%–25% of the total pre-retrofit annual utility bill. Even though a number of existing methods can effectively move ducts into the conditioned space, they are not currently being widely implemented. Physically locating the ducts within the conditioned space is most often applicable only to new construction projects and requires planning during design. Attics can be insulated at the roof deck with closed-cell polyurethane foam (ccSPF) to reduce duct losses and infiltration rates, but this method has high up-front costs and the potential to increase loads on the building enclosure. In hot-dry climates, attic duct systems can be buried under loose-fill insulation at a significantly lower cost to reduce thermal loads. In hot-humid climates, however, condensation on the duct jacket can occur when the humidity in the attic is high.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Verifying a Simplified Fuel Oil Flow Field Measurement Protocol

The Better Buildings program is a U.S. Department of Energy program funding energy efficiency retrofits in buildings nationwide. The program is in need of an inexpensive method for measuring fuel oil consumption that can be used in evaluating the impact that retrofits have in existing properties with oil heat. This project developed and verified a fuel oil flow field measurement protocol that is cost effective and can be performed with little training for use by the Better Buildings program as well as other programs and researchers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DOE Building America Technology and Energy Savings Analysis of Two 2,721 ft 2 Homes in a Mixed Humid Climate

The ZEBRAlliance is an opportunity to accelerate progress toward DOE’s goal of maximizing cost-effective energy efficiency by investing in a highly leveraged, focused effort to test new high-efficiency components emerging from Oak Ridge National Laboratory’s (ORNL) Cooperative Research and Development Agreement (CRADA) partners and others. The Alliance integrated efficient components into the construction of four research houses that will be used as test markets to gauge the success of the components and houses. These four research houses are expected to be the first houses used to field-test several newly emerging products such as the ClimateMaster ground-source integrated heat pump. When these new components are proven, they will become available to serve regional and national homebuilding markets. Some of these products will impact existing housing retrofit markets as well as new construction. These four houses demonstrate different strategies for saving energy, but all are about 55-60% more efficient than traditional new construction (based on third party certified HERS evaluations). After the research period, the houses will be sold to interested home buyers. The outcome will contribute to efforts by TVA to defer 1,400 MW of new electricity generation and reduce growth in energy consumption by 4.3 million MWh per year by 2012, and in the longer term, to transform how homes are built and retrofitted for improved energy efficiency in the Tennessee Valley.

Jackson, Roderick K.↗

Moisture Durability of Vapor Permeable Insulating Sheathing [Fact Sheet]

In this project, Building America team Building Science Corporation researched some of the ramifications of using exterior, vapor permeable insulation on retrofit walls with vapor permeable cavity insulation. Retrofit strategies are a key factor in reducing exterior building stock consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Small Town Energy Program (STEP) (Final Report revised)

University Park, Maryland (“UP”) is a small town of 2,540 residents, 919 homes, 2 churches, 1 school, 1 town hall, and 1 breakthrough community energy efficiency initiative: the Small Town Energy Program (“STEP”). STEP was developed with a mission to “create a model community energy transformation program that serves as a roadmap for other small towns across the U.S.” STEP first launched in January 2011 in UP and expanded in July 2012 to the neighboring communities of Hyattsville, Riverdale Park, and College Heights Estates, MD. STEP, which concluded in July 2013, was generously supported by a grant from the U.S. Department of Energy (DOE). The STEP model was designed for replication in other resource-constrained small towns similar to University Park - a sector largely neglected to date in federal and state energy efficiency programs. STEP provided a full suite of activities for replication, including: energy audits and retrofits for residential buildings, financial incentives, a community-based social marketing backbone and local community delivery partners. STEP also included the highly innovative use of an “Energy Coach” who worked one-on-one with clients throughout the program. Please see www.smalltownenergy.org for more information. In less than three years, STEP achieved the following results in University Park: • 30% of community households participated voluntarily in STEP; • 25% of homes received a Home Performance with ENERGY STAR assessment; • 16% of households made energy efficiency improvements to their home; • 64% of households proceeded with an upgrade after their assessment; • 9 Full Time Equivalent jobs were created or retained, and 39 contractors worked on STEP over the course of the project. Estimated Energy Savings - Program Totals kWh Electricity 204,407 Therms Natural Gas 24,800 Gallons of Oil 2,581 Total Estimated MMBTU Saved (Source Energy) 5,474 Total Estimated Annual Energy Cost Savings $\$61,343$ STEP clients who had a home energy upgrade invested on average $\$4,500$, resulting in a 13% reduction in annual energy use and utility bill savings of $325. Rebates and incentives covered 40%-50% of retrofit cost, resulting in an average simple payback of about 7 years. STEP has created a handbook in which are assembled all the key elements that went into the design and delivery of STEP. The target audiences for the handbook include interested citizens, elected officials and municipal staff who want to establish and run their own efficiency program within a small community or neighborhood, using elements, materials and lessons from STEP.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Better Buildings Neighborhood Program: BetterBuildings Lowell (Final Report)

The City of Lowell set four goals at the beginning of the Better Buildings Neighborhood Program: 1. Improve the Downtown Historic Park District’s Carbon Footprint 2. Develop a sustainable and replicable model for energy efficiency in historic buildings 3. Create and retain jobs 4. Promote multi-stakeholder partnerships. The City of Lowell, MA was awarded $5 million in May 2010 to conduct energy efficiency retrofits within the downtown National Historical Park (NHP). The City’s target was to complete retrofits in 200,000 square feet of commercial space and create 280 jobs, while adhering to the strict historical preservation regulations that govern the NHP.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

New Hampshire Better Buildings (Final Interim Report)

With $10 million in funding from the U.S. Department of Energy's (DOE) Better Buildings Neighborhood Program, the NH Better Buildings program was established as an initiative that initially empowered the three “Beacon Communities” of Berlin, Nashua and Plymouth to achieve transformative energy savings and reductions in fossil fuel use and greenhouse gases through deep energy retrofits and complementary sustainable energy solutions. The program also enabled those Communities to provide leadership to other communities around the state as “beacons” of energy efficiency. The goal of the program was to reduce energy use by a minimum of 15% through energy efficiency upgrades in residential and commercial buildings in the communities. The program expanded statewide in April 2012 by issuing a competitive solicitation for additional commercial projects non-profit, and municipal energy efficiency projects from any community in the state, and a partnership with the state’s utility-run, ratepayer-funded residential Home Performance with ENERGY STAR ® (HPwES) program. The NH Better Buildings program was administered by the New Hampshire Office of Energy and Planning (OEP) and managed by the NH Community Development Finance Authority (CDFA). The program started in July 2010 and the last projects funded with American Reinvestment and Recovery Act (ARRA) funds were completed in August 2013. The program will continue after the American Recovery and Reinvestment Act program period as a Revolving Loan Fund, enabling low-interest financing for deep energy retrofits into the future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrating Safety, Operations, Security, and Safeguards (ISOSS) into the design of small modular reactors : a handbook.

The existing regulatory environment for nuclear reactors impacts both the facility design and the cost of operations once the facility is built. Delaying the consideration of regulatory requirements until late in the facility design - or worse, until after construction has begun - can result in costly retrofitting as well as increased operational costs to fulfill safety, security, safeguards, and emergency readiness requirements. Considering the scale and scope, as well as the latest design trends in the next generation of nuclear facilities, there is an opportunity to evaluate the regulatory requirements and optimize the design process for Small Modular Reactors (SMRs), as compared to current Light Water Reactors (LWRs). To this end, Sandia has embarked on an initiative to evaluate the interactions of regulations and operations as an approach to optimizing the design of SMR facilities, supporting operational efficiencies, as well as regulatory requirements. The early stages of this initiative consider two focus areas. The first focus area, reported by LaChance, et al. (2007), identifies the regulatory requirements established for the current fleet of LWR facilities regarding Safety, Security, Operations, Safeguards, and Emergency Planning, and evaluates the technical bases for these requirements. The second focus area, developed in this report, documents the foundations for an innovative approach that supports a design framework for SMR facilities that incorporates the regulatory environment, as well as the continued operation of the facility, into the early design stages, eliminating the need for costly retrofitting and additional operating personnel to fulfill regulatory requirements. The work considers a technique known as Integrated Safety, Operations, Security and Safeguards (ISOSS) (Darby, et al., 2007). In coordination with the best practices of industrial operations, the goal of this effort is to develop a design framework that outlines how ISOSS requirements can be incorporated into the pre-conceptual through early facility design stages, seeking a cost-effective design that meets both operational efficiencies and the regulatory environment. The larger scope of the project, i.e., in future stages, includes the identification of potentially conflicting requirements identified by the ISOSS framework, including an analysis of how regulatory requirements may be changed to account for the intrinsic features of SMRs.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗