Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Residential Building”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Performance Analysis of a Modular Small-Diameter Air Distribution System

This report investigates the feasibility of using a home-run manifold small-diameter duct system to provide space-conditioning air to individual thermal zones in a low-load home. This compact layout allows duct systems to easily be brought within conditioned space via interior partition walls. Centrally locating the air handling unit in the house significantly reduces duct lengths. The plenum box is designed so that each connected duct receives a similar amount of airflow—regardless of its position on the box. Furthermore, within a reasonable set of length restrictions each duct continues to receive similar airflow.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Evaluation of Advances in Energy-Efficiency Practices for Manufactured Homes

Through field-testing and analysis, this project evaluated whole-building approaches and estimated the relative contributions of select technologies toward reducing energy use related to space conditioning in new manufactured homes. Three lab houses of varying designs were built and tested side-by-side under controlled conditions in Russellville, Alabama. The tests provided a valuable indicator of how changes in the construction of manufactured homes can contribute to significant reductions in energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Business Metrics for High-Performance Homes: A Colorado Springs Case Study

The building industry needs to understand how energy ratings can impact homebuilders. Of interest is how energy efficiency may or may not have a positive impact on homebuilders’ business success. Focusing on Colorado Springs, Colorado, as a case study, the U.S. Department of Energy’s Building America research team IBACOS suggests a win–win between a builder’s investment in energy efficiency and that builder’s ability to sell homes. Although this research did not ultimately determine why a correlation may exist, a builder’s investment in voluntary energy-efficiency programs correlated with that builder’s ability to survive the Great Recession of 2007 to 2009. This report explores the relationship between energy-efficiency ratings and the market performance of several builders in Colorado Springs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Moisture Durability with Vapor-Permeable Insulating Sheathing

Exterior sheathing insulation is an effective strategy in increasing the overall R-value of wall assemblies; other benefits include decreasing the effects of thermal bridging and increasing the moisture durability of the built assembly. Vapor-permeable exterior insulation, such as mineral board or expanded polystyrene foam, are one such product that may be used to achieve these benefits. However,uncertainty exists on the effects of inward driven moisture and the interaction of increased sheathing temperatures on the moisture durability of the edifice. To address these concerns, Building Science Corporation (BSC) conducted a series of hygrothermal models for cities representing a range of different climate zones. This report describes the research project, key research questions, and theprocedures utilized to analyse the problems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pilot Demonstration of Phased Retrofits in Florida Homes (Fact Sheet)

The Florida Solar Energy Center (FSEC) and Florida Power and Light are pursuing a collaborative energy research/utility partnership to retrofit a large number of homes using a phased approach. The project is creating detailed data on the energy and economic performance of two levels of home retrofit - simple and deep. Acting as a pilot, this project is expected to provide the information necessary to significantly reduce energy use through much larger community-scale projects in collaboration with utilities, program administrators and other market leader stakeholders.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Cold Climate Foundation Wall Hygrothermal Research Facility, Cloquet, Minnesota (Fact Sheet)

This report focuses on the progress made to date and the technical details of the experiment. An overview of the experimental data being collected with some interesting highlights noted thus far is also provided. A full analysis of the experimental data and the drawing of conclusions with regard to the thermal and hygrothermal performance of the retrofit foundation insulation systems tested will only be possible after a full year of data has been collected in 2014.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Top Innovations 2012: ENERGY STAR for Homes Support

This Building America Top Innovations profile describes Building America’s technical support to ENERGY STAR for Homes, which has labeled more than 1.3 million ENERGY STAR homes that have delivered $23 billion in energy cost savings and avoided 210 million tons of green-house emissions.

Building America↗

Building America Top Innovations 2012: Building Science-Based Climate Maps

This Building America Top Innovations profile describes the Building America-developed climate zone map, which serves as a consistent framework for energy-efficiency requirements in the national model energy code starting with the 2004 IECC Supplement and the ASHRAE 90.1 2004 edition. The map also provides a critical foundation for climate-specific guidance in the widely disseminated EEBA Builder Guides and Building America Best Practice Guides.

Building America↗

Building America Top Innovations 2012: Vapor Retarder Classification

This Building America Top Innovations profile describes research in vapor retarders. Since 2006 the IRC has permitted Class III vapor retarders like latex paint (see list above) in all climate zones under certain conditions thanks to research by Building America teams.

Building America↗

Building America Case Study: Assessment of a Hybrid Retrofit Gas Water Heater

This project completed a modeling evaluation of a hybrid gas water heater that combines a reduced capacity tankless unit with a downsized storage tank. This product would meet a significant market need by providing a higher efficiency gas water heater solution for retrofit applications while maintaining compatibility with the half-inch gas lines and standard B vents found in most homes. The TRNSYS simulation tool was used to model a base case 0.60 EF atmospheric gas storage water, a 0.82 EF non-condensing gas tankless water heater, an existing (high capacity) hybrid unit on the market, and an alternative hybrid unit with lower storage volume and reduced gas input requirements.

ARBI↗

DOE Zero Energy Ready Homes

This article describes the U.S. Department of Energy's Zero Energy Ready Home Program and Housing Innovation Awards. Since 2013, builders around the country have certified over 1,170 homes to the high performance criteria of the DOE Zero Energy Ready Home program. Each year DOE recognizes the best innovators among this group with the DOE Housing Innovation Awards. 2017 winners will be announced at an awards event taking place at the Energy & Environmental Building Alliance (EEBA) high-performance home summit October 10-12, 2017, in Atlanta, Georgia. Twenty-five builders are expected to take home awards and grand award winners in each of the five competition categories will be revealed at the conference. Participating builders represent every climate zone in the country and DOE Zero Energy Ready labeled homes can be found in 34 states. Homes represent the full spectrum of the U.S. construction industry, from affordable to production to custom homes and from single-family detached to duplexes and up to five-story multifamily buildings as well as some retrofit projects have also met the criteria. Every DOE ZER certified home is certified through the ENERGY STAR Certified Homes (Version 3.0, revision 8) program and the U.S. Environmental Protection Agency’s Indoor airPLUS program. Each home must meet the hot water distribution requirements of the EPA’s WaterSense program and the insulation requirements of the 2012 International Energy Conservation Code. If the home has HVAC ducts, they must be installed within the conditioned space of the home. Appliances, exhaust fans, ceiling fans, and most of the lighting should be ENERGY STAR qualified. The DOE Zero Energy Ready Home program also requires homes to have solar electric panels installed or at a minimum to have the conduit and electrical panel space in place for future PV installation, if the home is in a location appropriate for solar power. Homes are constructed with enough energy efficiency built in so that, with a reasonable amount of solar PV panels (i.e., small enough to fit comfortably on the roof), the home could produce enough of its own power to equal the power it uses in a year.

U.S. Department of Energy Building Technologies Pr↗

A Two-Step Time-Series Data Clustering Method for Building-Level Load Profile: Preprint

Residential and commercial buildings have huge potential to contribute value to improve grid resilience by participating grid services. To reveal the significant value, it is critical to estimate the grid service capability from these buildings. Unlike the large-scale distributed energy resources such as wind and solar farms, those buildings need to participate grid services in aggregation, not by individual. Therefore, it is important to appropriately group buildings for aggregation. In this paper, we develop a load profile clustering method to classify the building-level load profiles for grid service capability estimation. In our two-step clustering approach, we first calculate the total load consumption for each building, clustering the load profiles based on energy consumption level. Then, we further cluster the load profiles in each energy cluster based on the load shape. The parameter selection for each clustering step is discussed. The proposed method is applied on actual building-level load profiles, and the results have proved the effectiveness of this method.

advanced metering infrastructure (AMI)↗

Empirical Validation of UBEM: An Assessment of Bias in Urban Building Energy Modeling for Chicago

Residential and commercial buildings currently account for 30% of total global final energy consumption. Urban-scale building energy modeling (UBEM) can enable scalable investments and unlock building improvements by quantifying energy, demand, emissions, and cost reductions of specific measures or packages for building-specific technologies in large geographic regions. While the sophistication of UBEM data sources and technologies have increased dramatically in the past decade, there remains a knowledge gap for empirical validation and sources of bias between building-specific energy models and measured data at varying geographic scales.As UBEM continues to develop, systemic analysis of accuracy, bias, and limitations of the resulting models is necessary to inform best practices and move toward standardization. These are characterized for the Automatic Building Energy Modeling (AutoBEM) software suite with an initial case study involving metered electricity consumption data from 247,188 buildings in Chicago, Illinois, USA - averaged across years 2019-2021 - compared to the following datasets: (1) the AutoBEM-generated nation-scale Model America version 2 (MAv2) data for 596,064 buildings, (2) tax assessor data for 579,829 buildings, (3) tax assessor data filled with MAv2, and (4) 102 representative dynamic archetypes. The accuracy is reported for every building type and vintage combination, along with multiple sources of bias for unique building descriptors. The AutoBEM simulation workflow produced energy consumption estimates that closely match aggregated metered electricity consumption data for different types of buildings constructed during various time periods at the city scale - with initial normalized mean bias error of 10.9%, and 1.1% after removing outliers. Contribution of statistically significant factors including building type, land use, age, and size to variance in UBEM bias is quantified.

Garg, Ankur↗

Identifying Regions Favorable for Geothermal Heating and Cooling Storage

Space heating and cooling represents the single largest category of in building energy use for U.S. residential and commercial buildings, with heating representing 61% of residential and 46% commercial energy consumption. Building heating technologies are dominated by natural gas technologies, and are an important opportunity for building electrification to enable a transition to a low CO 2 energy system. FLXenabler study is a joint analysis effort among multiple analysis teams at NREL and focused on examining the role of geothermal heating and cooling (GHC) system with thermal energy storage (TES) providing flexibility. Utilizing information from ResStock the amount of energy consumption associated with heating and cooling by state was calculated. We applied adjusted load shapes to estimate the a maximum grid savings potential of using TES to address building space conditioning. Normalizing grid, fuel, and emissions impacts locations with higher favorability for further study in FLXenabler were identified.

15 GEOTHERMAL ENERGY↗