Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reference Values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Performance parameters of a liquid filled ionization chamber array

Purpose: In this work, the properties of the two-dimensional liquid filled ionization chamber array Octavius 1000SRS (PTW-Freiburg, Germany) for use in clinical photon-beam dosimetry are investigated.Methods: Measurements were carried out at an Elekta Synergy and Siemens Primus accelerator. For measurements of stability, linearity, and saturation effects of the 1000SRS array a Semiflex 31013 ionization chamber (PTW-Freiburg, Germany) was used as a reference. The effective point of measurement was determined by TPR measurements of the array in comparison with a Roos chamber (type 31004, PTW-Freiburg, Germany). The response of the array with varying field size and depth of measurement was evaluated using a Semiflex 31010 ionization chamber as a reference. Output factor measurements were carried out with a Semiflex 31010 ionization chamber, a diode (type 60012, PTW-Freiburg, Germany), and the detector array under investigation. The dose response function for a single detector of the array was determined by measuring 1 cm wide slit-beam dose profiles and comparing them against diode-measured profiles. Theoretical aspects of the low pass properties and of the sampling frequency of the detector array were evaluated. Dose profiles measured with the array and the diode detector were compared, and an intensity modulated radiation therapy (IMRT) field was verified using the Gamma-Index method and the visualization of line dose profiles.Results: The array showed a short and long term stability better than 0.1% and 0.2%, respectively. Fluctuations in linearity were found to be within ±0.2% for the vendor specified dose range. Saturation effects were found to be similar to those reported in other studies for liquid-filled ionization chambers. The detector's relative response varied with field size and depth of measurement, showing a small energy dependence accounting for maximum signal deviations of ±2.6% from the reference condition for the setup used. The σ-values of the Gaussian dose response function for a single detector of the array were found to be (0.72 ± 0.25) mm at 6 MV and (0.74 ± 0.25) mm at 15 MV and the corresponding low pass cutoff frequencies are 0.22 and 0.21 mm{sup −1}, respectively. For the inner 5 × 5 cm{sup 2} region and the outer 11 × 11 cm{sup 2} region of the array the Nyquist theorem is fulfilled for maximum sampling frequencies of 0.2 and 0.1 mm{sup −1}, respectively. An IMRT field verification with a Gamma-Index analysis yielded a passing rate of 95.2% for a 3 mm/3% criterion with a TPS calculation as reference.Conclusions: This study shows the applicability of the Octavius 1000SRS in modern dosimetry. Output factor and dose profile measurements illustrated the applicability of the array in small field and stereotactic dosimetry. The high spatial resolution ensures adequate measurements of dose profiles in regular and intensity modulated photon-beam fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Semiautomatic segmentation of liver metastases on volumetric CT images

Purpose: Accurate segmentation and quantification of liver metastases on CT images are critical to surgery/radiation treatment planning and therapy response assessment. To date, there are no reliable methods to perform such segmentation automatically. In this work, the authors present a method for semiautomatic delineation of liver metastases on contrast-enhanced volumetric CT images. Methods: The first step is to manually place a seed region-of-interest (ROI) in the lesion on an image. This ROI will (1) serve as an internal marker and (2) assist in automatically identifying an external marker. With these two markers, lesion contour on the image can be accurately delineated using traditional watershed transformation. Density information will then be extracted from the segmented 2D lesion and help determine the 3D connected object that is a candidate of the lesion volume. The authors have developed a robust strategy to automatically determine internal and external markers for marker-controlled watershed segmentation. By manually placing a seed region-of-interest in the lesion to be delineated on a reference image, the method can automatically determine dual threshold values to approximately separate the lesion from its surrounding structures and refine the thresholds from the segmented lesion for the accurate segmentation of the lesion volume. This method was applied to 69 liver metastases (1.1–10.3 cm in diameter) from a total of 15 patients. An independent radiologist manually delineated all lesions and the resultant lesion volumes served as the “gold standard” for validation of the method’s accuracy. Results: The algorithm received a median overlap, overestimation ratio, and underestimation ratio of 82.3%, 6.0%, and 11.5%, respectively, and a median average boundary distance of 1.2 mm. Conclusions: Preliminary results have shown that volumes of liver metastases on contrast-enhanced CT images can be accurately estimated by a semiautomatic segmentation method.

60 APPLIED LIFE SCIENCES↗

Optical Properties of Epitaxial Al{sub x}In{sub 1-x}Sb Alloy Layers

Optical studies of unstrained narrow-gap Al{sub x}In{sub 1-x}Sb semiconductor alloy layers are carried out. The layers are grown by molecular-beam epitaxy on semi-insulating GaAs substrates with an AlSb buffer. The composition of the alloys is varied within the range of x = 0-0.52 and monitored by electron probe microanalysis. The band gap E{sub g} is determined from the fundamental absorption edge with consideration for the nonparabolicity of the conduction band. The refined bowing parameter in the experimental dependence E{sub g}(x) for the Al{sub x}In{sub 1-x}Sb alloys is 0.32 eV. This value is by 0.11 eV smaller than the commonly referred one.

36 MATERIALS SCIENCE↗

Magnetic and Elastic Vibrations in Manganese–Zinc Spinel Crystals as the Functions of Anisotropy Constant

The amplitudes of magnetic and elastic vibrations for Mn{sub 0.61}Zn{sub 0.35}Fe{sub 2.04}O{sub 4} spinel crystalline slab are calculated by solving the equations describing the magnetic and elastic dynamics. The anisotropy constants, magnetization, second-order elastic constants and magnetoelastic coupling constants for a studied crystal are expressed as the functions of temperature. The magnetization vector and elastic shear components are found as the functions of the first magnetic anisotropy constant at different values of an external constant magnetic field greater than a saturation field. The procession patterns for normally and tangentially magnetized slabs are displayed for two values of the first anisotropy constant. High absolute values of the first anisotropy constant are shown to refer to reorientation of the magnetization vector.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Mapping Peptidergic Cells in Drosophila : Where DIMM Fits In

The bHLH transcription factor DIMMED has been associated with the differentiation of peptidergic cells in Drosophila. However, whether all Drosophila peptidergic cells express DIMM, and the extent to which all DIMM cells are peptidergic, have not been determined. To address these issues, we have mapped DIMM expression in the central nervous system (CNS) and periphery in the late larval stage Drosophila. At 100 hr after egg-laying, DIMM immunosignals are largely congruent with a dimm-promoter reporter (c929-GAL4) and they present a stereotyped pattern of 306 CNS cells and 52 peripheral cells. We assigned positional values for all DIMM CNS cells with respect to reference gene expression patterns, or to patterns of secondary neuroblast lineages. We could assign provisional peptide identities to 68% of DIMM-expressing CNS cells (207/ 306) and to 73% of DIMM-expressing peripheral cells (38/52) using a panel of 24 markers for Drosophila neuropeptide genes. Furthermore, we found that DIMM co-expression was a prevalent feature within single neuropeptide marker expression patterns. Of the 24 CNS neuropeptide gene patterns we studied, six patterns are .90% DIMM-positive, while 16 of 22 patterns are >40% DIMM-positive. Thus most or all DIMM cells in Drosophila appear to be peptidergic, and many but not all peptidergic cells express DIMM. The co-incidence of DIMM-expression among peptidergic cells is best explained by a hypothesis that DIMM promotes a specific neurosecretory phenotype we term LEAP. LEAP denotes Large cells that display Episodic release of Amidated Peptides.

59 BASIC BIOLOGICAL SCIENCES↗

Site-Representative Biota Concentration Guides at Los Alamos

Biota dose assessment at Los Alamos National Laboratory, LANL, follows the guidance of the DOE Standard, DOE-STD-1153-2002. As described in Section 2, general screening is performed using Biota Concentration Guides, BCGs, which are defined as "the limiting concentration of a radionuclide in soil, water, or sediment that would not lead to exceeding dose limits for the protection of biota in the environment." For the general screening, the maximum concentrations in water, sediment, and soil are compared with each radionuclide-specific BCG (DOE-STD-1153-2002 Table 2.1) and the sum of the fractions is calculated (DOE-STD-1153-2002 page M1-25.) The DOE Standard encourages each site to establish site-specific or site-representative BCGs (DOE-STD-1153-2002 Module 1 pages 10, 24-26, 43, 45-47, 50, 59, 61-64, 79, 81-86; Module 2 pages 31, 41, 49, 50, 53; and Module 3 page 29). The purpose of this paper is to establish site-representative BCGs for cesium-137 and strontium-90 in water, sediment, and soil. Sections 4.1 and 7.1.3.2 of DOE-STD-1153-2002 recommend the use of site-specific "lumped parameter values." The important lumped parameter is the bioaccumulation factor referred to in the DOE Standard as Biv. It is also commonly called the wet-weight concentration ratio C r ; see Module 3 Section 3.1 (page M3-19) of DOE-STD-1153-2002.

54 ENVIRONMENTAL SCIENCES↗

Building America Best Practices Series: Volume 17 - Energy Renovations-Insulation: A Guide for Contractors to Share With Homeowners

This guide will help contractors and homeowners identify ways to make their homes more comfortable, more energy efficient, and healthier to live in. It also identifies the steps to take, with the help of a qualified home performance contractor, to increase their home’s insulation, ensure healthy levels of ventilation, and prevent moisture problems. Contractors can use this document to explain the value of these insulation measures to their customers. The references in this document provide further explanation of insulation techniques and technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Spectroscopic research of Lambda hypernuclei up to medium-heavy mass region with the (e,e'K + ) reaction

In 2009 (August-November), the E05-115 experiment was carried out at JLab to investigate L hypernuclei in the wide mass region up to A = 52 ($7\atop{Λ}$He, $10\atop{Λ}$Be, $12\atop{Λ}$B and $52\atop{Λ}$V) with the (e,e'K + ) reaction. This is the first attempt to investigate a medium heavy L hypernucleus with the (e,e'K + ) reaction. Experimentally, it is difficult to measure heavier L hypernuclei as background rates of particles which originate from electromagnetic processes are roughly in proportion to Z2 (Z: target proton number) in the (e,e'K + ) experiment. To perform the experiment, many experimental techniques have been developed and introduced such as optimization of the electron spectrometer configuration (tilt method), clean kaon identification, particle tracking under high multiplicity environment, precise energy scale calibration and so on. In the present thesis, experimental results of the elementary process of p(e,e'K + )L, L hypernuclei of $7\atop{Λ}$He, $10\atop{Λ}$Be, $12\atop{Λ}$B and $52\atop{Λ}$V are shown. Elementary processes of the electroproduction of L and Σ 0 , p(e,e'K + )L, Σ 0 were used for the absolute energy scale calibration of our spectrometer systems. A careful Monte Carlo simulation shows that the binding energy can be obtained with a systematic error of 0.11 MeV with our energy scale calibration method. A study of the elementary process of L is important to understand L hypernuclei as it is essential for theoretical calculations of L hypernuclei. The differential cross section of the p(e,e'K + )L reaction at the small K + scattering angle (theta-CM/gamma-K approx. 15.5°), the small Q 2 (approx 0.01 [GeV/c] 2 ) and the total energy of W = 1.92 GeV, where no experimental data exists was obtained to be 235 ± 13$+28\atop{-24}$ nb/sr. The ground state (1/2 + ) binding energy of $7\atop{Λ}$He was already measured in JLab E01-011 (2005). In the present work, the binding energy of 1/2 + state was determined to be B Λ = 5.55 ± 0.10 ±0.11 MeV with five times more statistic and smaller systematic errors than those of the previous experiment. The ground state binding energy is important to test the phe- nomenologically introduced CSB (Charge Symmetry Breaking) LN interaction for A = 7, T = 1 hypernuclear systems. In addition, a peak which is interpreted as 3/2 + and 5/2 + states was measured to be B Λ = 3.65 ± 0.20 ±0.11 MeV with sufficient statistic for the first time. Only three events of the ground state of $10\atop{Λ}$ Be had been observed in the emulsion experiments. The present experiment is the first spectroscopic measurement of 10/L-Be, and the detailed structures have been successfully measured for the first time. About three times better energy resolution was achieved in the present experiment (0.78 MeV in FWHM) than that of the mirror L hy- pernucleus, $10\atop{Λ}$B (2.2 MeV in FWHM) which was measured in the (π + ,K + ) experiment at KEK. The result of the ground state binding energy was obtained to be B Λ = 8.55 ± 0.07 ± 0.11 MeV which serves also to discuss about the CSB effect in the LN interaction. $12\atop{Λ}$B has been measured with the world best energy resolution of 0:5 MeV (FWHM) among the reaction spectroscopy of L hypernuclei. The results of $12\atop{Λ}$B are compared with the experimental results in the previous experiments to confirm the consistency. Furthermore, the obtained ground state binding energies of $12\atop{Λ}$B (B Λ = 11.38 ± 0.02 ± 0.11 MeV) and $52\atop{Λ}$V (B Λ = 21.88 ± 0.59 ± 0.11 MeV) indicate that the reported value of 12/L-C which has been used as a reference of binding energy measurements for the (π + ,K + ) experiments would be shallower by ~ 0.5 MeV. A pilot study for investigation in the medium-heavy mass region with the (e,e'K + ) experiment was performed by measuring $52\atop{Λ}$V. The ground state binding energy of $52\atop{Λ}$V has been measured, overcoming high multiplicity environment. The results are discussed with the ex- perimental results of 51/L-V measured at KEK. The present result is the first measurement of L's binding energy of the ground state without the emulsion reference in the medium-heavy mass region, which could be a substantial improvement in the information needed for understanding the single particle potential of L. In the present experiment, L hypernuclear measurement with a small systematic error of ~ 0.1 MeV by the (e,e'K + ) reaction has been established. Moreover, the present work opened a door to the heavier L hypernuclear measurement with the (e,e'K + ) reaction in the future.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement Error Variance Estimation in Gamma-Spectroscopy Data using FRAM

The FRAM gamma-ray isotopic analysis code has recently been applied to four Pu data sets and four U data sets, each with relatively well-characterized standard items, in order to estimate the variances of random errors and of item-specific systematic errors. Assay results are available for Pu238, Pu239, Pu240, Pu241, Pu242 (operator entered, not independently measured), Am241, Specific Power, and Pu240eff. For the four U data sets, results are available for the measurands U234, U235, U236 (operator entered, not independently measured), and U238. For example, in Pu data set 1, there are 33 standard reference Pu items, which have well-known nominal/true values (except for a few items). FRAM was used to make approximately 15 repeat measurements for each of the 33 items, so empirical standard deviations can be calculated. In addition, FRAM internally estimates its random error variance using propagation of variance. This paper applies analysis of variance (ANOVA) to separately estimate the repeatability standard deviation and the standard deviation of the item-specific biases δ s in each of the 8 data sets.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Circuit increases capability of hysteresis synchronous motor

Frequency and phase detector circuit enables a hysteresis synchronous motor to drive a load of given torque value at a precise speed determined by a stable reference. This technique permits driving larger torque loads with smaller motors and lower power drain.

Markowitz, I. N.↗

Investigation of L-band shipboard antennas for maritime satellite applications

A basic conceptual investigation of low cost L-band antenna subsystems for shipboard use was conducted by identifying the various pertinent design trade-offs and related performance characteristics peculiar to the civilian maritime application, and by comparing alternate approaches for their simplicity and general suitability. The study was not directed at a single specific proposal, but was intended to be parametric in nature. Antenna system concepts were to be investigated for a range of gain of 3 to 18 dB, with a value of about 10 dB considered as a baseline reference. As the primary source of potential complexity in shipboard antennas, which have beamwidths less than hemispherical as the beam pointing or selecting mechanism, major emphasis was directed at this aspect. Three categories of antenna system concepts were identified: (1) mechanically pointed, single-beam antennas; (2) fixed antennas with switched-beams; and (3) electronically-steered phased arrays. It is recommended that an L-band short backfire antenna subsystem, including a two-axis motor driven gimbal mount, and necessary single channel monopulse tracking receiver portions be developed for demonstration of performance and subsystem simplicity.

Heckert, G. P.↗

The POGO data.

During intervals in 1967-1970, the OGO-4 and 6 spacecraft made over 2000 traversals over the equatorial electrojet in the altitude range 400-800 km when local times were between 9 and 15 hr. These spacecraft carried total field magnetometers making measurements to an accuracy of 2 gammas with a sample rate greater than once a second. Delta-F values, the deviations of these observations from an internal reference model, were plotted for a 30 deg band about the Equator, and the characteristics of the electrojet effect in the data were investigated. This effect was characterized by a sharp negative V-signature of some 16-19 deg in width and a variable amplitude.

Cain, J. C.↗

Summary of Skylab S-193 altimeter altitude results

The SKYLAB S-193 altimeter altitude results are presented in a concise format for further use and analysis by the scientific community. The altimeter mission and instrumentation is described along with the altimeter processing techniques and values of parameters used for processing. The determination of reference orbits is discussed, and the tracking systems utilized are tabulated. Techniques for determining satellite pointing are presented and a tabulation of pointing for each data mission included. The geographical location, the ocean bottom topography, the altimeter-determined ocean surface topography, and the altimeter automatic gain control history is presented. Some typical applications of this data are suggested.

Mcgoogan, J. T.↗

The method of Ritz applied to the equation of Hamilton

Without any reference to the theory of differential equations, the initial value problem of the nonlinear, nonconservative double pendulum system is solved by the application of the method of Ritz to the equation of Hamilton. Also shown is an example of the reduction of the traditional eigenvalue problem of linear, homogeneous, differential equations of motion to the solution of a set of nonhomogeneous algebraic equations. No theory of differential equations is used. Solution of the time-space path of the linear oscillator is demonstrated and compared to the exact solution.

Bailey, C. D.↗

Stress-concentration factors for finite orthotropic laminates with a circular hole and uniaxial loading

Stresses were calculated for finite-width orthotropic laminates with a circular hole and remote uniaxial loading using a two-dimensional finite element analysis with both uniform stress and uniform displacement boundary conditions. Five different laminates were analyzed. Computed results are presented for selected combinations of hole diameter/sheet-width ratio d/w and length-to-width ratio L/w. For small L/w values, the stress-concentration factors K sub tn were significantly different for the uniform stress and uniform displacement boundary conditions. Typically, for the uniform stress condition, the K sub tn values were much larger than for the infinite strip reference condition; however, for the uniform displacement condition, they were only slightly smaller than for this reference. The results for long strips are also presented as width correction factors. For d/w less or = 0.33, these width correction factors are nearly equal for all five laminates.

Hong, C. S.↗

Some studies of zonal and meridional wind characteristics at low latitude Indian stations

At the beginning of the Indian Middle Atmosphere Programme (IMAP), it was decided that the preparation of consolidation reports of already available parameters for the middle atmosphere would be useful. Atmospheric wind data obtained by rockets and balloons constituted one such parameter which had to be consolidated. The present paper summaries the results of this consolidation study. Both zonal and meridional components of winds at four low latitude Indian stations namely Thumba, Shar, Hyderabad, and Balasore, have been analyzed to yield reference wind profiles for each month. The montly mean values have been used to bring out the amplitudes and phases of the annual, semiannual and quasi-biennial oscillations.

Nagpal, O. P.↗

Noncoplanar magnetic fields, shock potentials, and ion deflection

A puzzling aspect of the structure of collisionless shock waves concerns the existence of a component of magnetic field that lies out of the coplanarity plane in the transition layer. It is shown that the existence of this component may be understood and its value calculated from a simple expression derived from first principles. The value of this field component may be derived without reference to the transformation properties of the fields or the changes in energy that the ions and electrons undergo on traversing the electrostatic potential of the shock interface.

Jones, Frank C.↗