Generation of long time creep data on refractory alloys at elevated temperatures

Four separate studies of various aspects of the vacuum creep behavior of two tantalum alloys (T-111 and ASTAR 811C) and of pure CVD tungsten are reported. The first part of the program involved a study of the influence of high temperature pre-exposure to vacuum or to liquid lithium on the subsequent creep behavior T-111 alloy. Results of this study revealed significant effects of pre-exposure on the 1% creep life of T-111, with life reductions of about 3 orders of magnitude being observed in extreme cases. The second part of this study involved an investigation of the creep behavior of T-111 under conditions of continuously increasing stress and decreasing temperature which simulated the conditions anticipated in radioisotope capsule service. Results of this study showed that such test conditions produced a creep curve having a very unusual shape, and led to the identification of a new creep design parameter for this type of service. The third area of investigation was a study of the influence of heat treatment on the microstructure and creep behavior of ASTAR 811C. The fourth part of the program was directed toward a preliminary characterization of the 1% creep life of CVD tungsten as obtained from two different sources.

Sheffler, K. D.↗

Design point characteristics of a 500 - 2500 watt isotope-Brayton power system.

An analytical study was conducted to investigate the potential performance characteristics of an isotope-Brayton space power system at electric power levels from 500 to 2500 W. Utilization of the Pu 238 heat source, or capsule, being developed for the Multi-Hundred Watt Radioisotope Thermoelectric Generator was assumed. A single-loop system design concept was selected. The design concept and results of first-order tradeoff studies of the effects of major system parameters on system performance are presented. Results of the study indicate the potential for high system efficiency and high specific power over the entire power range.

Barna, G. J.↗

Results of a real-time irradiation of lithium P/N and conventional N/P silicon solar cells.

Eight types of lithium-diffused P/N and three types of conventional 10 ohm-cm N/P silicon solar cells were irradiated at four different temperatures with a strontium-90 radioisotope at a rate typical of that expected in earth orbit. The six-month irradiation confirmed earlier accelerator results, showed that certain cell types outperform others at the various temperatures, and, in general, verified the recent improvements and potential usefulness of lithium solar cells. The experimental approach and statistical methods and analyses employed yielded increased confidence in the validity of the results. Injection level effects were observed to be significant.

Reynard, D. L.↗

Effect of low temperature on metabolism of rat liver slices and epididymal fat pads.

Study of low temperature effects on the metabolism of radioisotope-tagged glucose and palmitate in rat liver slices and epididymal fat pads. The obtained data suggest that the oxidative capacity of rat liver and adipose tissue is maintained at low temperatures to a greater degree than the synthetic capacity. It was concluded that sufficient energy can be produced at 17 C for maintenance of essential tissue functions by these two tissues but that the energy requirements may not be met at 7 C.

Hillyard, L. A.↗

A target design for irradiation of NaI at high beam current.

A solution to the targetry problems encountered when the iodine nucleus is a target for cyclotron irradiation is given as a new target design. A target based on this design has been used in 30 microampere irradiations of 46 MeV alpha particles for one-half hour without significant damage. Such an irradiation produces 6 to 7 mCi of Cs-129, an isotope useful in nuclear medicine. This target should also be considered for cyclotron production of the radioisotopes Cs-127, I-123, and Xe-127.

Blue, J. W.↗

Silicon-germanium technology program of the Jet Propulsion Laboratory.

The outer planetary exploration missions studied by the Jet Propulsion Laboratory require silicon-germanium radioisotope thermoelectric generators (RTGs) in which the factors of safety are as low as is compatible with the reliable satisfaction of the power needs. Work on silicon germanium sublimation performed at the Jet Propulsion Laboratory is presented. Analytical modeling work on the solid-diffusion process involved in the steady-state (free) sublimation of silicon germanium is described. Analytical predictions are made of the sublimation suppression which can be achieved by using a cover gas. A series of accelerated (high-temperature) tests which were performed on simulated hardware (using four SiGe couples) to study long-term sublimation and reaction mechanisms are also discussed.

De Winter, F.↗

A model to predict the degradation of a SiGe thermopile.

Discussion of the various phenomena which affect the available output power of a typical radioisotope thermoelectric generator (RTG), including estimates of the magnitude of these effects. Power degradation, as well as the corresponding changes in operating temperature, are calculated by means of a computer code which systematically accounts for the time- and temperature-dependent variables. A model for predicting available output power of an RTG is developed which includes changes in performance due to fuel decay, alteration of bulk thermoelectric properties, changes in electrode contacts, geometry changes due to material sublimation, and degradation of the thermal insulation.

Stapfer, G.↗

Isotope Brayton electric power system for the 500 to 2500 watt range.

An extensive study was conducted at the Lewis Research Center to evaluate an isotope Brayton electric power system for use in the 500 to 2500 W power range. The study emphasized overall system simplicity in order to reduce parasitic power losses and improve system reliability. The study included detailed parametric cycle analysis, conceptual component designs, and evaluation of system packaging. The study has resulted in the selection of a single-loop system (gas) with six major components including one rotating unit. Calculated net system efficiency varies from 23 to 28% over the power range. The use of the Pu-238 heat source being developed for the Multi-Hundred-Watt Radioisotope Thermoelectric Generator program was assumed.

Macosko, R. P.↗

An integrated radiation physics computer code system.

An integrated computer code system for the semi-automatic and rapid analysis of experimental and analytic problems in gamma photon and fast neutron radiation physics is presented. Such problems as the design of optimum radiation shields and radioisotope power source configurations may be studied. The system codes allow for the unfolding of complex neutron and gamma photon experimental spectra. Monte Carlo and analytic techniques are used for the theoretical prediction of radiation transport. The system includes a multichannel pulse-height analyzer scintillation and semiconductor spectrometer coupled to an on-line digital computer with appropriate peripheral equipment. The system is geometry generalized as well as self-contained with respect to material nuclear cross sections and the determination of the spectrometer response functions. Input data may be either analytic or experimental.

Steyn, J. J.↗

Space Shuttle orbiter power system requirements and design.

This paper is the third in a series discussing space station-shuttle power systems. The power requirements of the orbiter and a tradeoff study of several possible power system concepts are presented. The power sources considered are fuel cells, solar array/battery, radioisotope Brayton, and cryogenic fueled turboalternators. A fuel cell power source is chosen as the best candidate for the orbiter power system. A baseline power system is defined using four fuel cells, secondary batteries, primary emergency batteries, and constant speed drive-alternator units for ferrying power. A weight and cost summary is included.

Lombard, J. W.↗

SNAP-27/ALSEP power subsystem used in the Apollo program.

The Apollo Lunar Surface Experiments Package (ALSEP) measures lunar physical and environmental characteristics and transmits the data to receiving stations on earth. The data are used to derive information on the composition and structure of the moon. The electrical power subsystem generates and conditions all the electrical power for operations of the ALSEP system. The power source for the ALSEP is the Systems for Nuclear Auxiliary Power (SNAP) Radioisotope Thermoelectric Generator (RTG). The generator produces electricity by thermoelectric conversion. The radioactive isotope plutonium 238 is used as the energy source for the SNAP-27. By April 1, 1970, the SNAP-27 RTG had produced more than 230 kWh of continuous and stable power for the ALSEP.-

Remini, W. C.↗

The evolution of power systems for unmanned interplanetary spacecraft in the 70's.

The power subsystems planned for missions in the 70s have relied heavily on earlier hardware technology and represent an extension of technology conceived in the 60s. Solar panels and primary rechargeable silver-zinc batteries were used throughout the series as power sources. However, because of the increase in battery discharge-charge cycles required, subsequent spacecraft beginning with the Mariner Mars 1971 will use nickel-cadmium batteries. Spacecraft missions to Mars and Venus will continue to use the solar panel and the battery as primary and secondary power sources. The use of the radioisotope thermoelectric generator as the primary power source appears mandatory for missions to the outer planets.

Swerdling, M.↗

An evolutionary approach for a compact-split-core reactor.

An economical approach for advanced reactor power development is presented, and systems that result from the several stages of this plan are described. The development starts with a highly modularized heat-pipe, radioisotopic design and evolves into a low-specific-weight, high-performance reactor system.

Breitwieser, R.↗

Video instrumentation for radionuclide angiocardiography.

Two types of videoscintiscopes for performing radioisotopic angiocardiography with a scintillation camera are described, and use of these instruments in performing clinical studies is illustrated. Radionuclide angiocardiography is a simple, quick and accurate procedure recommended as a screening test for patients with a variety of congenital and acquired cardiovascular lesions. When performed in conjunction with coronary arterial catheterization, dynamic radionuclide angiography may provide useful information about regional myocardial perfusion. Quantitative capabilities greatly enhance the potential of this diagnostic tool.

Kriss, J. P.↗

High temperature material interactions of thermoelectric systems using silicon germanium.

The efficient use of silicon germanium thermoelectric material for radioisotope thermoelectric generators (RTG) is achieved by operation at relatively high temperatures. The insulation technique which is most appropriate for this application uses multiple layers of molybdenum foil and astroquartz. Even so, the long term operation of these materials at elevated temperatures can cause material interaction to occur within the system. To investigate these material interactions, the Jet Propulsion Laboratory is currently testing a number of thermoelectric modules which use four silicon germanium thermoelectric couples in conjunction with the multifoil thermal insulation. The paper discusses the results of the ongoing four-couple module test program and correlates test results with those of a basic material test program.

Stapfer, G.↗

Performance testing of a Transit generator at JPL.

A Transit type thermoelectric generator, serial number QM-III, assembled with lightweight Isotec type thermoelectric panels, has been placed on test at the Jet Propulsion Laboratory. In its exterior appearance and main constructive features, generator QM-III is similar to the generator which was flown on the Transit satellite, launched into circular polar orbit on Sept. 2, 1972. The main difference between the flight generator and QM-III is that the flight hardware is heated by radioisotope decay, while QM-III is an ETG and is assembled with three different types of thermoelectric panels. The paper describes the generator and test equipment used and presents the results of the tests performed to date.

Rouklove, P.↗

Ultraminiature X-ray fluorescence spectrometer for in-situ geochemical analysis on Mars.

A spectrometer based upon the X-ray fluorescence method of elemental analysis has been developed in an ultraminiature, rugged form suitable for a spacecraft mission to Mars. The instrument employs two radioisotope sources (Fe-55 and Cd-109) which irradiate adjacent areas on a regolith sample. Fluorescent X rays emitted by the sample are detected by four thin-window proportional counters. Using pulse-height discrimination, the energy spectra are determined. Virtually all elements above sodium in the periodic table are detected if present at sufficient levels. Minimum detection limits range from 30 ppm to 2% depending upon the element and the matrix. For most elements, they are below 0.5%. Accuracies also depend upon the matrix, but are generally better than plus or minus 0.5% for all elements of atomic number greater than 14. Elements below sodium are also detected, but as a single group. Ambiguities of identification of the elements producing the observed spectra are minimal.

Clark, B. C.↗