Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “REFRIGERATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Design progress of cryogenic hydrogen system for China Spallation Neutron Source

China Spallation Neutron Source (CSNS) is a large proton accelerator research facility with 100 kW beam power. Construction started in October 2011 and is expected to last 6.5 years. The cryogenic hydrogen circulation is cooled by a helium refrigerator with cooling capacity of 2200 W at 20 K and provides supercritical hydrogen to neutron moderating system. Important progresses of CSNS cryogenic system were concluded as follows. Firstly, process design of cryogenic system has been completed including helium refrigerator, hydrogen loop, gas distribution, and safety interlock. Secondly, an accumulator prototype was designed to mitigate pressure fluctuation caused by dynamic heat load from neutron moderation. Performance test of the accumulator has been carried out at room and liquid nitrogen temperature. Results show the accumulator with welding bellows regulates hydrogen pressure well. Parameters of key equipment have been identified. The contract for the helium refrigerator has been signed. Mechanical design of the hydrogen cold box has been completed, and the hydrogen pump, ortho-para hydrogen convertor, helium-hydrogen heat exchanger, hydrogen heater, and cryogenic valves are in procurement. Finally, Hydrogen safety interlock has been finished as well, including the logic of gas distribution, vacuum, hydrogen leakage and ventilation. Generally, design and construction of CSNS cryogenic system is conducted as expected.

43 PARTICLE ACCELERATORS↗

Effect of niobium addition on the martensitic transformation and magnetocaloric effect in low hysteresis NiCoMnSn magnetic shape memory alloys

The effect of Nb substitution for Ni in Ni{sub 45}Co{sub 5}Mn{sub 40}Sn{sub 10} magnetic shape memory alloys on their magnetic properties, martensitic transformation characteristics, transformation hysteresis, and magnetocaloric properties was studied using wavelength-dispersive X-ray spectroscopy, differential scanning calorimetry, and the temperature and field dependence of the magnetization. Ni{sub 45}Co{sub 5}Mn{sub 40}Sn{sub 10} alloy has a very low transformation hysteresis; however, the martensitic transformation temperatures are notably above room temperature, which is not desirable for magnetic refrigeration applications. In this study, small quantities of Nb substitution were shown to drastically shift the transformation temperatures to lower temperatures, at a rate of 68 K/at. % Nb, which is needed for household refrigeration. The austenite Curie temperature also decreased with increasing Nb content. However, a decrease in the latent heat of the martensitic transition was observed, which negatively affects the magnetic field-induced adiabatic temperature change capability. Still, the relatively large transformation entropy and the low transformation hysteresis make the Nb-doped Ni{sub 45}Co{sub 5}Mn{sub 40}Sn{sub 10} alloys potential candidates for solid state refrigeration near room temperature.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetocaloric properties of rare-earth substituted DyCrO{sub 3}

Recently, there has been a focus on the need for efficient refrigeration technology without the use of expensive or harmful working fluids, especially at temperatures below 30 K. Solid state refrigeration, based on the magnetocaloric effect, provides a possible solution to this problem. The rare-earth chromites (RCrO{sub 3}), especially DyCrO{sub 3}, with its large magnetic moment dysprosium ion, are potential candidates for such an application. The Dy{sup 3+} ordering transition at low temperatures (<10 K) likely causes a large magnetocaloric response in this material. This study investigates the possibility of tuning the magnetocaloric properties through the use of rare-earth substitution. Both Y{sup 3+} and Ho{sup 3+} substitutions were found to decrease the magnetocaloric response by disrupting the R{sup 3+} ordering. Whereas Er{sup 3+} substitution was found to increase the magnetocaloric response, likely due to an increase in the R{sup 3+} ordering temperature. The large magnetocaloric entropy change of Er{sup 3+} substituted DyCrO{sub 3} (10.92 J/kg K with a relative cooling power of 237 J/kg at 40 kOe and 5 K) indicates that this material system is well suited for low temperature (<30 K) solid state refrigeration applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Highly-Efficient Microemulsion-Based Absorption Chillers for HVAC Application

Air conditioning is a necessity to achieve a comfortable, habitable home or office for many places in US. However, vapor compression air conditioners are largely made with chlorofluorocarbon refrigerants, or CFCs, which create problems for a world grappling with climate change. In addition, vapor compression air conditioners are driven by electricity. Cooling and heating represent one-third of building electrical energy consumption in US. An absorption chiller is different to vapor compression chillers or air conditioners because it doesn’t use conventional refrigerants, like CFC. Instead, they may use water as the refrigerant which is mixed with safe and nontoxic absorbents. The research performed in this project advanced the understanding of absorption cooling technology and its application in HVAC. Various technologies were explored to improve the performance of the desorber and absorber components in the absorption chillers.

42 ENGINEERING↗

The preservation of urine samples for determination of renal stone risk factors

A preservation technique for urine specimens before determination of stone risk factors was evaluated. The purpose of these experiments was to prove the effectiveness of the preservatives used to prevent changes in the concentrations of those constituents measured. Measured concentrations in fresh specimens were compared with those in the same specimens after storage with the preservatives. Refrigeration at 4 degrees C up to five days was appropriate in a laboratory setting, as no significant changes in urinary concentrations occurred. Refrigeration, however, did not offer a convenient method for shipping. Chemical preservation was found to be an effective alternative to refrigeration. Thymol prevented changes in concentration of pH, citrate, uric acid, sulfate, sodium, potassium, and cyclic AMP, while a mixture of hydrochloric (HCl) acid and boric acid prevented changes in calcium, magnesium, phosphorus, oxalate, ammonium, and creatinine. Thus, the addition of thymol or HCl/boric acid to urine specimens will prevent significant changes in the concentrations of stone risk factors.

Non-NASA Center↗

Computer Modeling VRF Heat Pumps in Commercial Buildings using EnergyPlus

Variable Refrigerant Flow (VRF) heat pumps are increasingly used in commercial buildings in the United States. Monitored energy use of field installations have shown, in some cases, savings exceeding 30% compared to conventional heating, ventilating, and air-conditioning (HVAC) systems. A simulation study was conducted to identify the installation or operational characteristics that lead to energy savings for VRF systems. The study used the Department of Energy EnergyPlus? building simulation software and four reference building models. Computer simulations were performed in eight U.S. climate zones. The baseline reference HVAC system incorporated packaged single-zone direct-expansion cooling with gas heating (PSZ-AC) or variable-air-volume systems (VAV with reheat). An alternate baseline HVAC system using a heat pump (PSZ-HP) was included for some buildings to directly compare gas and electric heating results. These baseline systems were compared to a VRF heat pump model to identify differences in energy use. VRF systems combine multiple indoor units with one or more outdoor unit(s). These systems move refrigerant between the outdoor and indoor units which eliminates the need for duct work in most cases. Since many applications install duct work in unconditioned spaces, this leads to installation differences between VRF systems and conventional HVAC systems. To characterize installation differences, a duct heat gain model was included to identify the energy impacts of installing ducts in unconditioned spaces. The configuration of variable refrigerant flow heat pumps will ultimately eliminate or significantly reduce energy use due to duct heat transfer. Fan energy is also studied to identify savings associated with non-ducted VRF terminal units. VRF systems incorporate a variable-speed compressor which may lead to operational differences compared to single-speed compression systems. To characterize operational differences, the computer model performance curves used to simulate cooling operation are also evaluated. The information in this paper is intended to provide a relative difference in system energy use and compare various installation practices that can impact performance. Comparative results of VRF versus conventional HVAC systems include energy use differences due to duct location, differences in fan energy when ducts are eliminated, and differences associated with electric versus fossil fuel type heating systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Why high-frequency pulse tubes can be tipped

The typical low-frequency pulse-tube refrigerator loses significant cooling power when it is tipped with the pulse tube's cold end above its hot end, because natural convection in the pulse tube loads the cold heat exchanger. Yet most high-frequency pulse-tube refrigerators work well in any orientation with respect to gravity. In such a refrigerator, natural convection is suppressed by sufficiently fast velocity oscil1ations, via a nonlinear hydrodynamic effect that tends to align the density gradients in the pulse tube parallel to the oscillation direction. Since gravity's tendency to cause convection is only linear in the pulse tube's end-to-end temperature difference while the oscillation's tendency to align density gradients with oscillating velocity is nonlinear, it is easiest to suppress convection when the end-to-end temperature difference is largest. Simple experiments demonstrate this temperature dependence, the strong dependence on the oscillating velocity, and little dependence on the magnitude or phase of the oscillating pressure. In some circumstances in this apparatus, the suppression of convection is a hysteretic function of oscillating velocity. In some other circumstances, a time-dependent convective state seems more difficult to suppress.

36 MATERIALS SCIENCE↗

A chemical kinetic mechanism for combustion and flame propagation of CH 2 F 2 /O 2 /N 2 mixtures

Here in this work, we compiled and evaluated rate expressions for reactions relevant to the decomposition and combustion of CH 2 F 2 (difluoromethane, refrigerant R-32) in CH 2 F 2 /O 2 /N 2 flames. The recommended values have been used in premixed flame calculations, reported elsewhere, to model experimentally derived burning velocities determined using a constant volume spherical flame method. In this work, we also provide a detailed description of the reaction pathways for decomposition and combustion of CH 2 F 2 . This work is part of a larger effort at NIST to characterize and predict the flammability of new refrigerant working fluids and their blends for consideration as replacements of current refrigerants with high global warming potentials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Magnetocaloric effect in “reduced” dimensions: Thin films, ribbons, and microwires of Heusler alloys and related compounds: Magnetocaloric effect in “reduced” dimensions

Room temperature magnetic refrigeration is an energy saving and environmentally-friendly technology which has developed rapidly from a basic idea to prototype devices. The performance of magnetic refrigerators crucially depends on the magnetocaloric properties and the geometry of the employed refrigerants. Here we review the magnetocaloric properties of Heusler alloys and related compounds with a high surface to volume ratio such as films, ribbons and microwires, and compare them with their bulk counterparts.

magnetocaloric effect↗

Development, calibration, and validation of a novel gray-box energy model for residential split air conditioners

Energy models for vapor compression refrigeration in residential air conditioners have been developed through white-box, gray-box, and black-box methods in decades. However, existing white-box and gray-box models require complicated equations with detailed geometries while black-box models require substantial experimental data. Further, this paper aims to develop and validate a simple gray-box steady-state energy model without the need for detailed geometries, which can accurately predict the cooling capacity and electrical power input based on outdoor and indoor air conditions, and supply airflow rates. First three state variables, including the evaporation and condensation temperatures, and refrigerant mass flowrate, are applied to develop the energy model and are solved by three physical equations, including the energy conservations at the evaporator and condenser, and the refrigerant volume-mass flow correlation of the compressor. Secondly, seven performance property functions related to three state variables and three physical equations are identified and calibrated by simple temperature and power measurements. Finally, field experiments are conducted on a residential air conditioner to calibrate these performance property functions and validate the developed model. The validated results reveal the model can accurately predict the cooling capacity and electrical power input, with the normalized root mean square errors of 2.3% and 0.87% respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Near-isothermal-isobaric compressed gas energy storage

In this paper, the effectiveness of storing energy by compressing and expanding a condensable gas is evaluated. A high efficiency energy storage system, which stores energy by compressing/expanding gas (air) using a liquid (water) piston has been recently introduced and extensively studied. With the use of the liquid piston, the inefficient gas turbomachines used in conventional gas compression/expansion systems are replaced with high efficiency hydraulic machines. Utilizing heat transfer techniques and replacing the non-condensable air with a condensable gas (i.e. CO 2 , synthetic refrigerants, hydrocarbon refrigerants, etc.) have been proposed as methods to improve energy density and roundtrip efficiency of such systems, leading to near isothermal and near isobaric charge/discharge processes. In order to investigate the effectiveness of the proposed concept, a miniature lab-scale experimental setup was designed and built to investigate the compression/expansion characteristics and energy storage efficiency of a system utilizing R134a as the energy storage (primary) working fluid, and mineral refrigerant oil as the liquid piston (secondary) working fluid. Several tests are carried out to quantify energy storage efficiency and energy density. It is found that improving heat transfer rates from/into the storage fluid results in increased efficiency and energy density. A heat-transfer enhancement strategy to achieve near isothermal, isobaric expansion and compression is proposed and investigated experimentally. Some results are generalized and presented in non-dimensional form which can be applied to describe and/or design scaled-up systems. Lastly, a potential working fluid for a scaled-up system is discussed.

25 ENERGY STORAGE↗

On falling film evaporator – A review of mechanisms and critical assessment of correlation on a horizontal tube bundle with updated development

Optimization of the energy efficiency and reduction of the greenhouse gas emission for the heat pump system is imperative to meet the net-zero goals at 2050. Chillers with falling film evaporator design not only possess better system performance but also contain less refrigerant inventory. Hence, accurate prediction of the evaporator performance is pivotal especially when charged with low-GWP refrigerant. Here, the study reviews the correlations for falling film evaporator with a horizontal tube bundle configuration. The major efforts of this study include four tasks: (a) literature review of the experimental studies and available empirical correlations; (b) comprehensive discussion of the falling film evaporation heat transfer mechanism; (c) development of a new rationally based correlation based on available literature; and (d) comparison of different correlations based on the existing data. The collected data includes 4114 data points from 8 sources, 6 refrigerants (R-600a, R-290, R-245fa, R-134a, R-1234ze(E), R-123), 5 types of the tubes (Plain, Turbo-GII-HP, GEWA-B, Low-fin, High-Flux), liquid Weber number from 2.2 × 10 –6 to 0.7, imposed vapor Weber number from 0 to 37.2, heat flux from 2.5 to 151.5 kW/m 2 , and film Reynolds number from 1 to 3159.8. The new correlation gives a MAD of 28.3%, and an R 2 of 0.86. Yet, the developed correlation considers various heat transfer mechanisms, including the transition point from falling film evaporation to the nucleate boiling, local evaporation, dry-out, mist flow, imposed flow, and enhanced tube effects.

42 ENGINEERING↗

Enhancing the thermosiphon-driven discharge of a latent heat thermal storage system used in a personal cooling device

Personal cooling devices reduce energy loads by allowing buildings to operate with elevated setpoint temperatures, without compromising on the occupant comfort. One such novel technology called the Roving Comforter (RoCo) uses a compact R134a based vapor compression system for cooling. Following its cooling operation, during which waste heat from the condensing refrigerant is stored in a phase change material (PCM), a two-phase loop thermosiphon is used to discharge (solidify) the PCM to enable its next operation. The transient operation of this thermosiphon is the focus of the present paper. Use of a PCM as the storage medium provides high energy density due to the ability to store thermal energy as latent heat during the phase transition; however, the discharge rate is limited by the low thermal conductivity of the PCM. Insertion of a graphite foam within the PCM can increase the rate of discharge and decrease the downtime of the cooling device. Since graphite enhancement involves a tradeoff between improving the discharge time at the expense of PCM volumetric latent heat, the impact of graphite foam density on the PCM discharge rate is investigated by using a Modelica-based transient model of the thermosiphon. The semi-empirical model, which uses relevant heat transfer coefficient and pressure drop correlations for both refrigerant and airside heat transfer, captures the complex phenomena involving simultaneous phase change of the refrigerant and the PCM. Finally, the graphite enhanced PCM selected from this analysis results in a 51% reduction in the discharge time with addition of only 5% to the thermal storage weight, without compromising the required cooling time.

42 ENGINEERING↗

Active magnetic regenerative cooling with smaller magnets

Magnetocaloric heat pumping near room temperature, a.k.a. magnetic cooling, relies on the active regenerator cycle to achieve functional temperature spans and realize economic and societal benefits promised by this emerging solid-state cooling technology. The cycle itself depends upon synchronizing oscillating flow of a heat transfer fluid through a solid porous active material matrix, or the refrigerant, with periods when the refrigerant is in the highest available (field-on) and in nearly zero (field-off) magnetic fields to accomplish heat transfer. With this in mind, in this work we analyze varying flow and magnetic field wave forms and the timing between when the fluid is pumped and when the magnetic field is turned on and off. We demonstrate that the volume and the cost of permanent magnet generating the field changes can be cut nearly in half with little to no effect on the device temperature span and cooling power normalized by the refrigerant mass.

36 MATERIALS SCIENCE↗

Universal correlation for falling film evaporation on a horizontal plain tube

Falling film evaporators are widely used in many industrial sectors, such as desalination, refrigeration & air-conditioning, and chemical processes. The heat transfer correlations suitable for wider operating conditions and various refrigerants are useful for designing falling film evaporators. Although many researchers developed the correlation for their own experimental data, there is a limited universal correlation for falling film evaporators. In addition, the dry-out effects were not considered in the available universal correlations. Here, therefore, this study proposes a new correlation for falling film evaporation on a single horizontal plain tube, which includes nucleate boiling, film evaporation, and dry-out effects. The proposed correlation covers a wider range of operating conditions (Heat flux is of 2.5–168kWm -2 , and film Reynolds number is up to 3500), various refrigerants (R134a, R245fa, R1234ze(E), R123, R32, R410A, R290, and R600a), and the large number of experimental data (1101 data in total). The proposed correlation is validated against the available standard correlation with regard to mean absolute deviation (MAD) and R 2 values. The MAD of the new correlation is about 10%, respectively, which is the lowest among other correlations. Similarly, the R 2 showed a value of 0.92, which is the highest compared to the existing correlations. A simplified correlation is also proposed.

42 ENGINEERING↗

Scalable and Resilient Etched Metallic Micro- and Nanostructured Surfaces for Enhanced Flow Boiling

Flow boiling and evaporation in tubes and channels occur in a wide variety of energy systems, such as refrigeration, air conditioning, power generation, electronics cooling, distillation, and purification. In this work, we demonstrate remarkably increased heat transfer coefficients of 270% during refrigerant flow boiling in scalable microstructured (~40 µm), industrial-scale (~1 m long) aluminum (Al) tubes, when compared to smooth unstructured Al tubes. To achieve scalable nanomanufacturing, we create highly conformal and durable structured surfaces by relying on hydrochloric acid Al etching. Flow boiling tests were conducted in 6.35 mm diameter Al tubes using R134a refrigerant as the working fluid. To benchmark our approach and to elucidate the effect of the structure length scale, we also fabricated ultrascalable boehmite (AlO(OH)) nanostructured (~300 nm) Al tubes, showing that etched microscale features are necessary and key to enhancement. Durability tests conducted using a 28 day long continual flow boiling experiment demonstrated negligible degradation of the etched surfaces. The scalable and cost-effective techniques used to create these durable, etched-Al microstructures may significantly reduce manufacturing cost when contrasted with current enhancement approaches such as extrusion, drawing, and welding.

36 MATERIALS SCIENCE↗

High Propane and Isobutane Adsorption Cooling Capacities in Zirconium-Based Metal–Organic Frameworks Predicted by Molecular Simulations

Adsorption cooling systems are emerging alternatives to traditional compression-based cooling systems due to their reduced electricity costs. Metal–organic frameworks (MOFs) have the potential to be ideal adsorbent materials for this application, as they can be tuned to have desired adsorption behavior for different refrigerants. In this study, we studied the adsorption behaviors of propane and isobutane, which are environmentally friendly refrigerants that have been recommended as substitutes for (hydro)chlorofluorocarbons, in two mesoporous Zr-based MOFs, namely, NU-1000 and NU-1003, which have the same topology but different pore sizes. Both MOFs showed high cooling capacities with the refrigerants, and for isobutane, the cooling capacities were 2 to 4 times higher than MIL-101, which is the only MOF with a previously reported isobutane adsorption cooling capacity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗