Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “READOUT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Radiation Tolerant Electronics and Digital Processing for the Phase-1 Read-out Upgrade of the ATLAS Liquid Argon Calorimeters

The ATLAS Liquid Argon calorimeters are designed and built to study proton-proton collisions produced at the LHC at centre-of-mass energies up to 14 TeV. Liquid argon (LAr) sampling calorimeters are employed for all electromagnetic calorimetry in the pseudorapidity region |η|<3.2, and for hadronic calorimetry in the region from |η|=1.5 to |η|=4.9. Although the nominal LHC experimental programme is still in progress, an upgrade of the read-out electronics is being launched to cope with luminosities of up to 3x10{sup 34} cm{sup -2}s{sup -1}, which are beyond the original design by a factor of 3. An improved spatial granularity of the trigger primitives is therefore proposed in order to improve the identification performance for trigger signatures, like electrons, photons, tau leptons, jets, total and missing energy, at high background rejection rates. For the upgrade Phase-1 in 2018, new LAr Trigger Digitizer Boards (LTDB) are being designed to receive higher granularity signals, digitize them on detector and send them via fast optical links to a new LAr digital processing system (LDPS). The LDPS applies a digital filtering and identifies significant energy depositions in each trigger channel. The refined trigger primitives are then transmitted to the first level trigger system to extract improved trigger signatures. The read-out of the trigger signals will process 34000 so-called Super Cells at every LHC bunch-crossing at a frequency of 40 MHz. The new LTDB on-detector electronics is designed to be radiation tolerant in order to be operated for the remaining live-time of the ATLAS detector up to a total luminosity of 3000 fb{sup -1}. For the analog-to-digital conversion (12-bit ADC at 40 MSPS), the data serialization and the fast optical link (5.44 Gb/s) custom components have been developed. They have been qualified for the expected radiation environment of a total ionization dose of 1.3 kGy and a hadron fluence of 6 x 10{sup 13} h/cm{sup 2} with energies above 20 MeV. For the digital components like the ADC, cross-sections for single event effects have been determined. This talk will present R and D results from tests of the radiation tolerant components, the fast data processing electronics and prototypes of the LTDB and LDPS boards. First experience from a Demonstrator setup will be reported, in which about 1/10 of the full Super Cell readout will be equipped with prototype versions of the LTDB and LDPS boards. The Demonstrator will be operated in parallel to the regular ATLAS trigger read-out during the upcoming LHC run. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Estimation of position resolution for DOI-PET detector using diameter 0.2 mm WLS fibers [ANIMMA--2015-IO-x5]

We have been developing a submillimeter resolution and low-cost DOI-PET detector using wavelength shifting fibers (WLSF), scintillating crystal plates and MPPCs (Hamamatsu Photonics). Conventional design of DOI-PET detectors had approximately mm{sup 3} of resolution by using some scintillating blocks with a volume of 1 mm{sup 3}, which detects gamma-ray. They are expensive due to difficulties in processing scintillating crystals and a large number of photo-detectors, and these technologies are likely to reach the limit of the resolution. Development of a lower cost DOI-PET detector with higher resolution is challenging to popularize the PET diagnosis. We propose two type of PET detector. One is a whole body PET system, and the other is a PET system for brain or small animals. Each PET system consists 6 blocks. The former consists of 6 layers of crystal plates with 300 mm x 300 mm x 4 mm. The latter consists of 16 crystal layers, forming 4 x 4 crystal arrays. The size of the crystal plate is 40 mm x 40 mm x 1 mm. Wavelength shifting fiber (WLSF) sheets are attached to above and up and down side of crystal planes. The whole PET system has 8 MPPCs attached on each side. For the brain PET detector, 9 WLSF fibers are attached on the each side. The expected position resolution would be less than 1 mm at the former system. We have performed an experimental performance estimation for the system component using {sup 22}Na radioactive source. We achieved a collection efficiency of 10% using the WLSF sheet and Ce:Gd{sub 3}(Al,Ga){sub 5}O{sub 12} (GAGG) crystals at 511 keV. The linear relationship between reconstruction position and incident position was obtained, and a resolution of 0.7 mm (FWHM) for x-axis of DOI by the WLSF readout was achieved. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pixelated CZT Technology for the Detection, Identification, and Localization of Gamma-Ray Sources - 18311

Radioactive waste-management applications require good measurements to qualitatively and quantitatively characterize waste materials. Often these measurements must be done in situ, and the user wishes to learn something of the isotopic and spatial distribution of the source. Therefore, there is a need for a portable instrument that can map radioactive contamination and quantify sources. This presentation introduces several instruments that have been applied to this task, along with example measurements in relevant applications. All instruments are based on 3D-position-sensitive CdZnTe (CZT) detectors. This technology routinely achieves better than 1.1% FWHM energy resolution at 662 keV and operates at room temperature with a startup time under 2 minutes. All are packaged in portable enclosures with WiFi and Bluetooth capabilities for wireless communication. These capabilities allow the technology to be used in more advanced measurements in the field. A unique capability of these detectors is the ability to image the spatial distribution of gamma rays from a single stationary measurement. The first product, Polaris-H, has been in use at commercial nuclear power plants since 2013. The system, currently used at over 50% of the US nuclear-power fleet, integrates a 3D-position-sensitive CZT detector, associated readout electronics, an embedded computer, a battery with over 7-hour life, an optical camera, and a laser range finder in a portable water-proof enclosure. The system connects wirelessly to a tablet which displays a gamma-ray spectrum and isotope-specific images of the gamma-ray distribution in all directions in real time. The CZT detectors have a dynamic range from 50 keV up to 3 MeV. Coded aperture or pinhole imaging is used for energies below 250 keV, and Compton imaging is used for energies above 250 keV. List-mode data is saved to an external USB memory stick to enable more advanced analysis, including isotopic activity analysis, via H3D's post-processing software. Additional systems based on the same architecture have been developed to optimize the technology for other applications. These include Polaris-H Quad, which provides over 3 times the sensitivity for applications involving weaker sources, and Polaris-H Shield, which uses a collimator to provide images and isotope information over a narrower field of view in order to measure weaker sources in the presence of stronger sources of the same isotope. H3D has also developed custom systems that have been mounted on robots and drones that enable remote operation of the technology. Results from the measurements collected at commercial nuclear power plants and other applicable sites will be presented to show how these instruments can be used to detect, identify, and localize gamma-ray sources. Advanced analysis techniques to show the accurate quantification of the gamma-ray source will also be presented. Applications range from characterizing simple objects, to locating hottest points, estimating contamination distributions on an isotope-by-isotope basis, and differentiating scatter and direct emissions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Data Analyst - A Device for Continuous Repeating Real-Time Assay of HPGe, CZT, or Scintillation Gamma Spectra - 18574

There are many situations where a continuous repeating series of quantitative gamma spectral assays is desirable. These include measurements of fluid going through a pipe, of items on a conveyor passing under a detector, a detector aimed at the ground on a moving platform, or a detector in free air as a plume of radioactivity drifts by. While Canberra and many others have built and deployed many of these devices, they have all been custom built for that particular application, and rather expensive. The Data Analyst [DA] is a general purpose device that is designed to fulfill many of these applications without modification, but can be fairly-easily modified if needed. The DA is a small [12 x 18 x 5 cm], low-power [3 W] box that accepts the input from external MCAs, controls the acquisition cycle, analyzes the results, and transmits them to the outside world when needed. The detector-MCAs supported are HPGe with Lynx MCA, NaI or CeBr or LaBr with Osprey MCA, and CZT or CsI with internal MCAs. The DA internal software used for analysis is the full standard Genie analysis software, which is very widely used and well accepted in the industry. This allows exported spectral files to be reviewed and confirmed by Experts, and reanalyzed if needed. The DA hardware is totally autonomous. As soon as power is applied, it starts the pre-programmed sequences of acquisition and analysis. Multiple analysis sequences [called Workflows] can be in operation simultaneously, e.g. with different count times and different nuclide libraries. Only the detector with MCA, and the DA are required in the field. A PC can be connected to the DA locally or remotely via WiFi, USB, or Ethernet. The PC is needed to setup the DA, and to readout the results. The DA also supports [with application-specific programming] external Inputs/Outputs either for recording with the analysis results or for use in the computation of the result, e.g. temperature, flow rate, pressure, ... ]. The DA also has an internal GPS receiver with external antenna. Applications of the DA that are discussed include stack gas effluent activity where a portion of the effluent stream was extracted to flow through a shield with a HPGe detector and Lynx MCA, and measurement of reactor coolant activity where a shielded CZT detector and MCA were aimed at various sections of reactor primary coolant during a maintenance outage. Potential other applications are also described. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Proposed Muon Radiography Method for Spent Fuel Cask Interrogation

Multiple scattering muon radiography is a technique that was developed at Los Alamos National Laboratory (LANL) to detect high Z material using cosmic ray muons as a radiation source. As a result,there has been considerable interest in using the technique to radiograph nuclear waste inside of storage casks. Recently,the technique has been used to interrogate the inside of a MC-10 dry fuel cask at Idaho National Laboratory (INL).This is the only technique that has been successful in imaging the interior of a spent fuel cask.The measurement was performed with the LANL Mini Muon Tracker (MMT), composed of two super-modules of drift tubes and readout electronics placed on each side of the fuel cask. The final result was a one dimensional histogram (projection) that showed areal scattering density within the cask binned according to horizontal position within the cask. While successful, the MMT is not designed for an optimal measurement of a fuel cask. The MMT only covers a limited solid angle around the cask and needs to be orientated so as to be aligned with the grid of stored fuel bundles. Even when properly aligned, the resulting areal scattering density projection indicates that a fuel bundle within a column is missing, but is ambiguous as to which row is lacking the fuel bundle. This paper discusses a potential new detector and analytical technique that may be used to better radiograph the nuclear material inside of a storage cask. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Large Volume Airborne Contamination Monitoring To Support Nuclear Processes' Deactivation and Decommissioning

Current D and D operations at Hanford have demonstrated a flaw in the current state of the art capability of defining airborne contamination boundaries - Airborne particulate emissions of Pu-239 from CM2H operations on the Hanford Pu Finishing Plant were detected well beyond areas controlled for airborne Pu, putting numerous workers at risk for radiological assimilations - Current air samplers and CAM systems were surveying insufficient volumes of air to accurately predict where respiratory protection was required - Hanford is located in a high radon environment, making air monitoring for alpha emitting actinides challenging in high alpha radon induced backgrounds. - Inexpensive HEPA based home and industrial air purifiers filter significantly higher volumes of air than commercially available continuous-air monitoring (CAM) systems. - Inexpensive models capable of filtered air volumes exceeding 1000 times that of a CAM. - Detector system can be built to detect x-rays generated from actinide decay. - Branching ratios of x-rays are 4 orders of magnitude more intense from Plutonium decay than its gamma emissions. - Detector system can be a low resolution systems, as x-ray region of interest is not terribly congested. - Detection systems evaluated will be designed based on slabs of NaI or pixelated NaI or CsI panels. - Simple graphical user interface software will be developed to operate the detection system. - Concept is to deploy some of these air-purifying systems in nonradiological areas around SRNL to confirm radon can be rejected with confidence. - Generate some filters contaminated with plutonium via electroplated Pu or lab generated simulated particles. - then deploy units in known airborne radiological environments to establish systems ability to accurately measure actinide based hot particles Lab analyses will follow up the system analyses to ensure hot particles were correctly identified. Analysis by Scintillation: - Application of scintillation media to the surface of the filters is being explored. - Evaluating slabs of ZnS(Ag), application of powdered ZnS(Cu) and spray on Perkin Elmer Enhance. - Scintillation events would then be digitized with a digital camera and quantified. - Comparing against sensitivity of a PMT or SiPD readout. - Currently evaluating a Thorlabs 8 Megapixel Monochrome Scientific CCD Camera, hermetically sealed cooled package with a wide angle lens. - Wide angle lens allows complete view of HEPA filter from 7 inches away. - Images taken of glow in the dark paint, as well as plutonium-induced fluorescence. - Plutonium was flamed mounted on a 1 inch diameter stainless steel planchet, covered with a layer of mylar and a section of scintillating ZnS obtained from Eljon. - Currently working on reducing signal-to-noise levels to boost sensitivity. - Dark box to hold contaminated or electroplated source covered filters under fabrication. Analysis by x-ray Spectroscopy: - Branching ratios for x-ray emissions from Plutonium isotopes are orders of magnitude more intense than gamma-ray emissions. - The nuclear databases are incomplete on the branching ratios of some of the isotopes. - Evaluating some custom built SrI2 x-ray spectrometers vs a conventional windowed NaI detector. - SrI2 detectors are carbon-composite-windowed 51 mm x 51 mm. - MCNP calculations to establish self absorbance of filter media on 17 keV x-ray. Radon Rejection: - Activated charcoal pre-filter acts as a Radon trap. - Adding a time lapse feature to camera to aid in radon rejection. SRS Plutonium Fuel Form D and D Operations: Currently deploying air sampler to D and D operation of Pu-238 facility at SRS to generate some field samples to analyze.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of Plutonium-Contaminated Gloveboxes using a High-Range Alpha Ion Chamber

Between September 2014 and July 2015, personnel at Lawrence Livermore National Laboratory (LLNL) decontaminated, characterized, and removed six high-activity plutonium-contaminated gloveboxes from the Building 332 Plutonium Facility. This project was based on similar decommissioning work that was done at the Rocky Flats Environmental Technology Site (RFETS), using a Ludlum Model 43-132 ion chamber with Model 195 readout unit. This summary describes the process that was used at LLNL to characterize all six gloveboxes as low-level waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reconstructing Solar Particle Event Spectra from Absorbed Dose Measurements

The space radiation environment is unlike anything encountered on Earth. It is dominated by heavy charged particles consisting of highly charged nuclei with atomic numbers ranging from 1 to 94 with a broad spectrum of kinetic energies. The three primary sources of radiation in space are trapped belts, galactic cosmic rays (GCRs), and solar particle events (SPEs). The trapped belts are only of concern near bodies with significant magnetic fields and GCR flux spectra are relatively well-predicted using models that account for solar modulation of the local interstellar spectrum. SPEs, which consist primarily of protons, are difficult to predict in terms of occurrence, duration, intensity, and energy spectrum. SPE intensity and energy spectrum are critical for understanding radiation exposure-related health effects for astronauts in space. The National Aeronautics and Space Administration (NASA) relies on data from the Geostationary Operational Environmental Satellite series to characterize intensities and energy spectra of SPEs near Earth. However, these data are not applicable for spacecraft in other regions of the solar system. To understand the radiation environment for astronauts embarking on travel beyond Earth orbit, NASA is developing the Hybrid Electronic Radiation Assessor (HERA), a distributed dosimetry system that employs a solid-state silicon sensor coupled with the Timepix readout chip. The pixelated nature of the detector permits detailed analyses of charged particle tracks which can then be used to characterize the fluence spectrum at the location of the detector. Despite the unprecedented level of detail regarding the radiation environment provided by these detectors, knowledge of the fluence spectrum at all locations within the vehicle, specifically inside of astronauts, is desired to fully characterize the associated risk of harmful health effects. Radiation transport of the external radiation environment, considering the shielding provided by the vehicle, other objects, and even astronauts, is performed to obtain this information. Thus, there is clearly a need to define the external radiation environment using measurements performed within the vehicle. The number of detectors that may be flown as a part of HERA is limited by logistics, including data, power, and mass restrictions. The current configuration for crewed flight consists of six detectors at various locations with in the Orion Multi-Purpose Crew Vehicle (MPCV). It follows that an external proton fluence spectrum can be characterized with at most six energy bins with traditional matrix inversion techniques. The purpose of the present study is to determine whether it is possible to reconstruct SPE spectra with greater resolution from absorbed dose measurements and knowledge of the response of individual detectors using linear programming.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tunable 3D Nanoresonators for Gas-Sensing Applications

Here, the detection of gas species with high sensitivity is a significant task for fundamental sciences as well as for industrial applications. Similarly, the ongoing trend for device miniaturization brings new challenges for advanced fabrication including on–demand functionality tuning. Following this motivation, here the additive, direct–write fabrication of freestanding 3D nanoarchitectures is introduced, which can be brought into mechanical resonance via electric AC fields. Specifically, this study focuses on the 3D nanostructure synthesis, the subsequent determination of Young's modulus, and demonstrates a postgrowth procedure, which can precisely tune the material modulus. As–fabricated resonators reveal a Young's modulus of 9–13 GPa, which can be increased by a factor greater than 5. Next, the electric readout of the resonance behavior is demonstrated via electric current measurement as an essential element for the resonance sensor applications. Finally, the implications of gas–physisorption and gas–chemisorption on the resonance frequencies are studied, representing a proof–of–principle for sensing applications by the here presented approach.

47 OTHER INSTRUMENTATION↗

Chemiresistors for the Real‐Time Wireless Detection of Anions

Abstract Reported is an electrical transduction platform for real‐time wireless anion sensing using single‐walled carbon nanotubes (SWCNTs) noncovalently functionalized with squaramide‐based anion binding selectors. Systematically studied are anion‐binding properties and efficiency of the electrical transduction of the functionalized SWCNT composites using the squaramide‐based selectors with two similar electron‐withdrawing groups, 3,5‐bis(trifluoromethyl)benzyl ( 1 ) and 3,5‐bis(trifluoromethyl)phenyl ( 2 ), which induce hydrogen‐bonding interaction with anions and deprotonation of a squaramide N–H proton upon addition of acetate (AcO − ), respectively. Charge transduction occurs with AcO − as a result of charge transfer from the deprotonated selector 2 , whereas less sensitive transduction is observed with selector 1 via hydrogen‐bonding interaction. These results provide guidelines to efficiently transduce the chemical interaction between selectors and anions to create resistive transduction with functionalized SWCNTs. Electron‐withdrawing groups adjacent to the squaramide as well as proximate cationic pyridyl groups, enhance the anion binding affinity and also lower the selector's p K a . The chemiresistive sensor arrays are readily integrated with a wireless sensing module and demonstrated real‐time sensing of multiple anions with a smartphone readout.

Choi, Seon‐Jin↗

Emergent Ferroelectric Switching Behavior from Polar Vortex Lattice

We report topologically protected polar textures have provided a rich playground for the exploration of novel, emergent phenomena. Recent discoveries indicate that ferroelectric vortices and skyrmions not only host properties markedly different from traditional ferroelectrics, but also that these properties can be harnessed for unique memory devices. Using a combination of capacitor-based capacitance measurements and computational models, it is demonstrated that polar vortices in dielectric–ferroelectric–dielectric trilayers exhibit classical ferroelectric bi-stability together with the existence of low-field metastable polarization states. This behavior is directly tied to the in-plane vortex ordering, and it is shown that it can be used as a new method of non-destructive readout-out of the poled state.

36 MATERIALS SCIENCE↗

Automated Label‐Free Assay for Viral Detection and Inhibitor Screening via Biomembrane‐Functionalized Microelectrode Arrays

Most virus infection assays have indirect readout such as virus number following entry (e.g., PCR, cell lysis). While effective, these technologies are labor‐intensive, require specialized environments (e.g., sterile or RNA‐free), and detect later‐stage viral events like lysis or cell death, lacking sensitivity to early fusion events. To address these limitations, we present biologically relevant 2D membrane materials, host‐cell‐derived supported lipid bilayers (hcd‐SLBs), integrated with organic microelectrode arrays (OMEAs) for detection of severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2) fusion. By overexpressing angiotensin‐converting enzyme 2 (ACE2) receptors on the native membranes, the platform functions as a viral sensor capable of detecting virus pseudo particles (VPPs) through the late pathway. Additionally, hcd‐SLBs extracted from human lung epithelium expressing native ACE2 detect fusion events through the early pathway. The platform's utility as a drug‐screening tool is demonstrated by testing antibodies targeting either the ACE2 on the host membrane or the viral spike (S) proteins. To enhance the throughput, microfluidics are integrated for automation and OMEAs are incorporated within each channel, miniaturizing the testing units. This system supports high‐throughput data generation, automation, and scalability, providing an efficient platform for viral fusion detection that advances the study of pathogen‐host interactions and accelerates antiviral drug discovery.

Biology↗

Nanoscale Compositional and Strain Gradients Enable High‐Speed and Amplitude‐Resolved Pyroelectric Sensing

The frequency response of pyroelectric sensors is fundamentally governed by thermal time constant (τth, determined by thermal mass and thermal conductance) and electrical impedance arising from film capacitance and readout circuit. Conventional bulk LiTaO3 detectors are optimized for high responsivity at low modulation frequencies (0.1-10 Hz), possessing a large τth that thermally averages rapid temperature oscillations at elevated modulation frequencies, limiting fidelity in resolving dynamic varying thermal signals. Here, compositional and strain gradients are introduced into 100-nm-thick relaxor-ferroelectric films reducing τth to ≈2 µs and producing built-in potentials (≈1.45 V or 145 kV cm-1) that enhance the pyroelectric coefficient and suppress the dielectric constant. This enables complementary dual-mode operation by enhancing current-mode electrical responsivity and improving the voltage-mode figure of merit - advantageous for superior temperature resolution (ΔTmin ≈ 30 µK). The responsivity peak shifts to near 1 kHz (>2500-times higher than conventional bulk sensors), with measurable responsivity extending to a carrier frequency of 100 kHz and amplitude-resolved detection at modulation frequencies up to 15 kHz. These results establish nanoscale internal-field engineering can reshape electro-thermal trade-off in pyroelectric thin films toward zero-bias, high-thermal-sensitivity, and amplitude-resolved thermal sensing across a wide frequency bandwidth.

Lin, Ching‐Che↗

Molecularly Imprinted Polymer Sensor Empowered by Bound States in the Continuum for Selective Trace-Detection of TGF-beta

The integration of advanced materials and photonic nanostructures can lead to enhanced biodetection capabilities, crucial in clinical scenarios and point-of-care diagnostics, where simplified strategies are essential. Herein, a molecularly imprinted polymer (MIP) photonic nanostructure is demonstrated, which selectively binding to transforming growth factor-beta (TGF-β), in which the sensing transduction is enhanced by bound states in the continuum (BICs). The MIP operating as a synthetic antibody matrix and coupled with BIC resonance, enhances the optical response to TGF-β at imprinted sites, leading to an augmented detection capability, thoroughly evaluated through spectral shift and optical lever analogue readout. The validation underscores the MIP-BIC sensor capability to detect TGF-β in spiked saliva, achieving a limit of detection of 10 fM and a resolution of 0.5 pM at physiological concentrations, with a precision of two orders of magnitude above discrimination threshold in patients. The MIP tailored selectivity is highlighted by an imprinting factor of 52, showcasing the sensor resistance to interference from other analytes. The MIP-BIC sensor architecture streamlines the detection process eliminating the need for complex sandwich immunoassays and demonstrates the potential for high-precision quantification. This positions the system as a robust tool for biomarker detection, especially in real-world diagnostic scenarios.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Electrocatalytic Effects of Au Nanoclusters in its Electrochemiluminescence Enhanced by Coreactant Tertiary Amines

Abstract Atomically precise metal nanoclusters are increasingly exploited in electrocatalysis such as water electrolysis and CO 2 reduction. The catalytic effects are generally evaluated by conventional electrochemical methods or end‐product analysis. Herein, near infrared electrochemiluminescence (ECL) of the nanoclusters is introduced as a new signaling mechanism to complement classical voltammetric analysis for elucidating essential electrocatalytic parameters. Coreactant ECL from an aqueous soluble Au 22 nanocluster (NCs) enhanced by a common pH buffer materials 4‐(2‐hydroxyethyl)‐1‐piperazineethanesulfonic acid (HEPES) and by a piperazine drug hydroxyzine (HDZ) is studied under oxidative reduction pathways. Foot of the wave analysis on voltametric features and the kinetics profiles in potential‐step experiments are studied in different nanocluster and coreactant concentrations. Benchmark parameters such as rate constants are determined under EC (Electron‐transfer‐Chemical‐reaction) mechanism as feasibility validations. Because the luminescence properties of AuNCs are sensitive to the surface ligands or adsorbents, ECL is proposed as a new signal readout for operando studies providing insights for governing reaction mechanism and kinetics during catalytic reactions. Retrospectively, mechanistic understanding of the complex multi‐step reactions during ECL generation can provide guidance for the evaluation and optimization of ECL property for better quantitative applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Room‐Temperature Mid‐Infrared Detection Using Metasurface‐Absorber‐Integrated Phononic Crystal Oscillator

Mid-infrared (MIR) detectors find extensive applications in chemical sensing, spectroscopy, communications, biomedical diagnosis, and space exploration. Alternative to semiconductor MIR photodiodes and bolometers, mechanical-resonator-based MIR detectors show advantages in higher sensitivity and lower noise at room temperature, especially toward longer wavelength infrared. Here, uncooled room-temperature MIR detectors based on lithium niobate surface acoustic wave phononic crystal (PnC) resonators integrated with wavelength-and-polarization-selective metasurface absorber arrays are demonstrated. The detection is based on the resonant frequency shift induced by the local temperature change due to MIR absorptions. The PnC resonator is configured in an oscillating mode, enabling active readout and low-frequency noise. The 1-GHz oscillator-based MIR detector shows a relative frequency deviation of 5.24 × 10 −10 Hz −1/2 at an integration time of 50 µs, leading to an incident noise equivalent power of 197 pW Hz −1/2 when input 6-µm MIR light is modulated at 1.8 kHz, and a large dynamic range of 10 7 in incident MIR power. The device architecture is compatible with the scalable manufacturing process and can be readily extended to a broader spectral range by tailoring the absorbing wavelengths of metasurface absorbers.

Xi, Zichen [Virginia Polytechnic Inst. and State U↗

Improved reconstruction stability for chemical shift encoded hyperpolarized 13 C magnetic resonance spectroscopic imaging using k‐t spiral acquisitions

Purpose A multiecho, field of view (FOV)‐oversampled k‐t spiral acquisition and direct iterative decomposition of water and fat with echo asymmetry and least‐squares estimation reconstruction is demonstrated to improve the stability of hyperpolarized 13 C magnetic resonance spectroscopic imaging (MRSI) in the presence of signal ambiguities attributed to low‐SNR (signal‐to‐noise‐ratio) species, local uncertainties in metabolite peaks, and echo‐to‐echo signal inconsistencies. Theory k‐t spiral acquisitions redistribute readout points to be more densely spaced radially in k‐space by acquiring an FOV and matrix that are oversampled by η . These more densely spaced spiral turns constitute effective intraspiral echoes and can supplement conventional interspiral echoes to improve spectral separation and reduce spectral cross‐talk to better resolve 13 C‐labeled species for spectroscopic imaging. Methods Digital simulations and imaging phantom experiments were performed for a range of interspiral echo spacings and η using multiecho, k‐t spiral acquisitions. Image spectral cross‐talk artifacts were evaluated both qualitatively and quantitatively as the percent error in measured metabolite ratios. In vivo murine experiments evaluated the feasibility of multiecho, k‐t spiral [1‐ 13 C]pyruvate MRSI to reduce spectral cross‐talk for 3 scenarios of different expected reconstruction stability. Results Digital simulations and imaging phantom experiments both demonstrated reduced or comparable image spectral cross‐talk and percent errors in measured metabolite ratios with increasing η and better choices of echo spacings. In vivo images displayed markedly reduced spectral cross‐talk in lactate images acquired with η = 7 versus η = 1. Conclusion The precision of hyperpolarized 13 C metabolic imaging and quantification in the presence of low‐SNR species, local uncertainties in metabolite resonances, and echo‐to‐echo signal inconsistencies can be improved with the use of FOV‐oversampled k‐t spiral acquisitions.

Macdonald, Erin B.↗

Shining a spotlight on intact proteins

Cells react to cues from their environment using various mechanisms that include changes in metabolites, gene expression, protein binding partners, protein localization, and protein posttranslational modifications (PTMs), all of which contribute to altered cellular signatures that enable appropriate cellular responses. Given the seemingly infinite number of mechanisms available to affect protein function and modulate biological processes, the question arises as to how cells manage to interpret protein readouts to accomplish the appropriate cell-type specific response to a particular stimulus.

Environmental Molecular Sciences Laboratory↗