A proposed high-intensity radiometer calibration method using concentrated solar radiation

Accurate calibration of irradiance measurement devices, or radiometers, is essential for ensuring the reliability of measurements in high heat applications such as concentrating solar power (CSP), aerospace, defense, and pulsed power systems. Despite the critical need, existing calibration standards and service providers are limited to irradiance levels below 100 kW/m 2 and specific radiation sources, which is insufficient for many applications. For instance, CSP technologies, particularly those under the Department of Energy’s Solar Energy Technologies Office (SETO) Gen 3 program, require accurate measurements of broadband irradiance at levels exceeding 2000 kW/m 2 . In even more extreme scenarios, such as re-entry vehicles, heat levels can surpass 10000 kW/m 2 . Current ISO standards, specifically ISO 14934–2 and ISO 14934–3, are constrained to lower irradiance levels and dependent on black body heat sources, limiting their applicability for high-intensity broadband irradiance measurements, particularly in concentrated solar applications. Here, to address this shortfall, the National Solar Thermal Test Facility (NSTTF) at Sandia National Laboratories (SNL) proposes a calibration method and facility capable of characterizing radiometers up to 2750 kW/m 2 using concentrated solar irradiance. Calibrating with concentrated sunlight is important for solar applications as it aligns the calibration process with the solar spectrum. This alignment is crucial for minimizing systematic errors and avoiding the need for additional corrections that may arise when radiometers designed for solar applications are calibrated using black-body or electrical sources. This paper presents the present day NSTTF characterization facility and procedure, detailing the proposed calibration method and uncertainty quantification. The presented method builds upon 1980′s NSTTF methodology and involves both theoretical and empirical methods to establish a robust relationship between gauge voltage output and irradiance intensity, quantifying both measurement and fitting errors. By addressing the limitations of existing standards and extending the characterization range, this work provides an advancement in the field of high-intensity irradiance measurement and instrumentation characterization.

Gardon gauge↗

Generation of radioisotopes for medical applications using high-repetition, high-intensity lasers

We used the PW high-repetition laser facility VEGA-3 at Centro de Láseres Pulsados in Salamanca, with the goal of studying the generation of radioisotopes using laser-driven proton beams. Various types of targets have been irradiated, including in particular several targets containing boron to generate α-particles through the hydrogen–boron fusion reaction. We have successfully identified γ-ray lines from several radioisotopes created by irradiation using laser-generated α-particles or protons including 43 Sc, 44 Sc, 48 Sc, 7 Be, 11 C and 18 F. We show that radioisotope generation can be used as a diagnostic tool to evaluate α-particle generation in laser-driven proton–boron fusion experiments. We also show the production of 11 C radioisotopes, ≈ 6 × 10 6 , and of 44 Sc radioisotopes, ≈ 5 × 10 4 per laser shot. This result can open the way to develop laser-driven radiation sources of radioisotopes for medical applications.

gamma ray spectroscopy↗

Purification and Improved Nuclear Radiation Detection of Tl 6 SI 4 Semiconductor

The wide-band-gap semiconductor Tl 6 SI 4 (2.14 eV) has high photon stopping power and is a promising material for detecting X-rays. To improve its photoresponse to low-flux γ-rays, material purification prior to crystal growth is crucial. In this contribution, we report effective purification protocols, impurity analysis, followed by synthesis and crystal growth, charge transport, and detector performance of large-sized Tl 6 SI 4 crystals. Purification methods of evaporation and zone refining were developed, and their high effectiveness was confirmed by impurity analysis via glow discharge mass spectrometry. Centimeter-sized single crystals were grown using the Bridgman method. The improved properties after material purification were confirmed by photoluminescence measurements. The energy of the valence band maximum of a Tl 6 SI 4 , measured with photoemission spectroscopy in air (PESA), is ~5.34 ± 0.05 eV. Detector devices fabricated from the single crystal exhibit a high resistivity of 5 × 10 12 Ω·cm. The detector shows potential photoresponse under 22.4 keV Ag Kα X-rays and 122 keV γ-rays from 57 Co. Spectroscopic energy resolution was achieved for 5.5 MeV α-particles from a 241 Am radiation source with a full width at half-maximum of 27% at an electric field intensity of 2500 V·cm -1 . On the foundation of its spectral response to 57 Co γ-rays, the electron mobility-lifetime product μeτe was estimated as 1.4 × 10 -5 cm 2 ·V -1 . Drift mobility measurements via a time-of-flight technique using spectral photoresponse induced by α-particles reveal a high electron mobility of 35 ± 7 cm 2 ·V -1 ·s -1 .

36 MATERIALS SCIENCE↗

Stabilization of Preternatural Barium Oxidation States as an Unexpected Byproduct of β-Decay: Discovery of a New Halide Semiconductor Alloy

137 Cs has a wide range of roles in the nuclear industry. The solid material, safely encapsulated in CsCl as 137 CsCl, is stored as fission product waste from nuclear power production and legacy waste from nuclear weapons production; it has also served as a radiation source in food and sewage irradiators as well as medical devices. However, because of the solubility of the chloride salt and the relatively high specific activity of 137 Cs, damaged or broken capsules can lead to severe radiological accidents. Safe capsule design and material recycling are complicated by the unclear structural evolution during β-decay, which remains ambiguous due to the differing oxidation states of Cs (1+) and Ba (2+). Here, in this study, we use first-principles calculations to investigate the evolving structure–property relationships of Cs 1–x Ba x Cl during β-decay. Despite the well-established 2+ formal oxidation state of alkali-earth metals, we find that Ba 1+ can be stabilized in the form of a mixed-valence alloy at low concentrations. Specifically, we identify three regimes for the β-decay of 137 Cs into CsCl: Ba-doped CsCl (Ba ≤ 14%), wherein Ba has the expected 2+ oxidation state; Cs–Ba–Cl alloys, where Ba has a mix of the usual Ba 2+ and highly unusual Ba 1+ oxidation state in the form of a quasi-disordered mixed-valence alloy (Ba = 25%); and phase separation into a CsCl + BaCl 2 + Ba (m) mechanical mixture, where Ba reverts to its expected 2+ oxidation state (Ba > 25%). Surprisingly, the Cs 0.75 Ba 0.25 Cl mixed-valence alloy is a narrow indirect band gap semiconductor (1.05 eV) despite the insulating nature of both CsCl and BaCl 2 . It also exhibits strongly excitonic polarized optical properties, has glass-like ultralow thermal conductivity (directional average of 0.21 W/mK at 300 K), and shows greater resistance to deformation under both tensile and volumetric strengths compared with the original CsCl structure (e.g., shear and Young’s modulus of 9.04 and 31.62 GPa, respectively). These findings imply that transmutation of 137 Cs leads to highly unusual chemical bonding that stabilizes Ba 1+ in local regions of the quasi-disordered Cs 0.25 Ba 0.75 Cl, resulting in anomalous physical properties. Moreover, this discovery provides valuable insight for safe nuclear waste capsule design, which can aid in preventing environmental or human exposure to radioactive materials.

Fuhr, Addis S. [Oak Ridge National Laboratory (ORN↗

Nanoparticle Alloy Formation by Radiolysis

Here, this Review Article focuses on the highly versatile and effective method of radiolysis for the synthesis of nanoparticles (NPs). In particular, the formation of bimetallic and alloyed nanoparticles (or nanoalloys), including both known super alloys and novel alloy NP compositions, is described. This Review Article discloses the synthesis techniques that rely on ionizing radiation sources to create metallic NPs. Then, alloy NPs formed from combinations of transition metals and noble metals with varied structures are described. Some of the advantages of radiolysis including exquisite control over the size, monodispersity, and alloying structure of NPs are discussed. Additionally, methodologies that facilitate the synthesis or deposition of NPs onto a range of supports under inert environments are described. Finally, applications of metallic NPs formed by radiolysis are summarized.

36 MATERIALS SCIENCE↗

Terahertz Spectroscopy of Gas Mixtures with Dual Quantum Cascade Laser Frequency Combs

Terahertz laser frequency combs based on quantum cascade lasers provide coherent, broadband, electrically pumped, THz radiation sources for use in future spectroscopic applications. In this work, we explore the feasibility of such lasers in a dual-comb spectroscopy configuration for the detection of multiple molecular samples in the gas phase. The lasers span approximately 180 GHz of optical bandwidth, centered at 3.4 THz, with submilliwatt total optical power. One of the main advantages of dual-comb spectroscopy is its high speed, which opens up the possibility for direct observations of chemical reaction dynamics in the terahertz spectral region. As a proof-of-concept, we recorded continuously evolving spectra from gas mixtures with 1 ms temporal resolution.

42 ENGINEERING↗

Perfect X-ray focusing via fitting corrective glasses to aberrated optics

Due to their short wavelength, X-rays can in principle be focused down to a few nanometres and below. At the same time, it is this short wavelength that puts stringent requirements on X-ray optics and their metrology. Both are limited by today’s technology. In this work, we present accurate at wavelength measurements of residual aberrations of a refractive X-ray lens using ptychography to manufacture a corrective phase plate. Together with the fitted phase plate the optics shows diffraction-limited performance, generating a nearly Gaussian beam profile with a Strehl ratio above 0.8. As a result, this scheme can be applied to any other focusing optics, thus solving the X-ray optical problem at synchrotron radiation sources and X-ray free-electron lasers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Femtosecond X-ray coherent diffraction of aligned amyloid fibrils on low background graphene

Here we present a new approach to diffraction imaging of amyloid fibrils, combining a free-standing graphene support and single nanofocused X-ray pulses of femtosecond duration from an X-ray free-electron laser. Due to the very low background scattering from the graphene support and mutual alignment of filaments, diffraction from tobacco mosaic virus (TMV) filaments and amyloid protofibrils is obtained to 2.7 Å and 2.4 Å resolution in single diffraction patterns, respectively. Some TMV diffraction patterns exhibit asymmetry that indicates the presence of a limited number of axial rotations in the XFEL focus. Signal-to-noise levels from individual diffraction patterns are enhanced using computational alignment and merging, giving patterns that are superior to those obtainable from synchrotron radiation sources. In conclusion, we anticipate that our approach will be a starting point for further investigations into unsolved structures of filaments and other weakly scattering objects.

47 OTHER INSTRUMENTATION↗

Frequency comb ptychoscopy

Multiheterodyne techniques using frequency combs—radiation sources whose lines are perfectly evenly-spaced—have revolutionized science. By beating sources with the many lines of a comb, their spectra are recovered. Even so, these approaches are fundamentally limited to probing coherent sources, such as lasers. They are unable to measure most spectra that occur in nature. Here we present frequency comb ptychoscopy, a technique that allows for the spectrum of any complex broadband source to be retrieved using a comb. In this approach, the spectrum is reconstructed by unfolding the simultaneous beating of a source with each comb line. We demonstrate this both theoretically and experimentally, at microwave frequencies. This approach can reconstruct the spectrum of nearly any complex source to high resolution, and the speed, resolution, and generality of this technique will allow chip-scale frequency combs to have an impact in a wide swath of new applications, such as remote sensing and passive spectral imaging.

42 ENGINEERING↗

Fabrication of THz corrugated wakefield structure and its high power test

We present overall process for developing terahertz (THz) corrugated structure and its beam-based measurement results. 0.2-THz corrugated structures were fabricated by die stamping method as the first step demonstration towards GW THz radiation source and GV/m THz wakefield accelerator. 150-μm thick disks were produced from an OFHC (C10100) foil by stamping. Two types of disks were stacked alternately to form 46 mm structure with ~ 170 corrugations. Custom assembly was designed to provide diffusion bonding with a high precision alignment of disks. The compliance of the fabricated structure have been verified through beam-based wakefield measurement at Argonne Wakefield Accelerator Facility. Both measured longitudinal and transverse wakefield showed good agreement with simulated wakefields. Measured peak gradients, 9.4 MV/m/nC for a long single bunch and 35.4 MV/m/nC for a four bunch trains, showed good agreement with the simulation.

43 PARTICLE ACCELERATORS↗

X-ray near-field multi-slice ptychography for in-situ imaging

Abstract In-situ imaging of chemical reactions can provide valuable insight into nanoparticle growth and structural evolution. Hard X-ray imaging is an excellent tool for this purpose, as it combines high spatial resolution with high penetration depth, allowing for realistic reaction environments. While far-field ptychography is a well-established method at synchrotron radiation sources, its near-field analog has received less attention. In this work we show that near-field multi-slice ptychography is a competitive method for high-resolution in-situ imaging by studying the formation of gold nanocages via galvanic replacement. Our work extends near-field X-ray ptychography to sub-50 nm spatial resolution by using multilayer Laue lenses. These high numerical aperture optics enable to distinguish sample layers that are separated by less than 100 µm by multi-slicing techniques.

Science & Technology - Other Topics↗

Scintillation event imaging with a single photon avalanche diode camera

Position and time measurements of scintillation events encode information about the radiation source. Single photon avalanche diode (SPAD) arrays offer multiple-megapixel spatial resolution and tens of picoseconds temporal resolution for detecting single photons. Current lensless designs for measuring scintillation events use sensors that are lower in spatial resolution. Camera-based designs use sensors that are lower in temporal resolution or readout rate and cannot image individual interactions. Here we propose to image scintillation events in a thick, monolithic scintillator using a high-resolution SPAD camera. We demonstrate that a commercial SPAD camera is able to gather sufficient signal to image individual scintillation events and observe 3D shifts in their spatial distribution. Simulations show that a SPAD camera can localize individual scintillation events in 3D. We report direct imaging of gamma-ray interactions in a scintillator with a SPAD camera. The proposed design may allow to measure complex signatures of individual particles interacting in the scintillator.

47 OTHER INSTRUMENTATION↗

Oxypnictide SmFeAs(O,F) superconductor: a candidate for high–field magnet applications

The recently discovered oxypnictide superconductor SmFeAs(O,F) is the most attractive material among the Fe-based superconductors due to its highest transition temperature of 56 K and potential for high-field performance. In order to exploit this new material for superconducting applications, the knowledge and understanding of its electro-magnetic properties are needed. Recent success in fabricating epitaxial SmFeAs(O,F) thin films opens a great opportunity to explore their transport properties. Here we report on a high critical current density of over 10 5 A/cm 2 at 45 T and 4.2 K for both main field orientations, feature favourable for high-field magnet applications. Additionally, by investigating the pinning properties, we observed a dimensional crossover between the superconducting coherence length and the FeAs interlayer distance at 30–40 K, indicative of a possible intrinsic Josephson junction in SmFeAs(O,F) at low temperatures that can be employed in electronics applications such as a terahertz radiation source and a superconducting Qubit.

36 MATERIALS SCIENCE↗

Potential for neutron and proton transmutation doping of GaN and Ga 2 O 3

As the potential applications of GaN and Ga 2 O 3 are limited by the inadequacy of conventional doping techniques, specifically when uniform selective area p-type doping is required, the potential for transmutation doping of these materials is analyzed. All transmuted element concentrations are reported as a function of time for several common proton and neutron radiation sources, showing that previously published results considered a small subset of the dopants produced. A 40 MeV proton accelerator is identified as the most effective transmutation doping source considered, with a 2.25 × 10 17 protons per cm 2 fluence yielding net concentrations of uncompensated p-type dopants of 7.7 × 10 15 and 8.1 × 1015 cm -3 for GaN and Ga 2 O 3 , respectively. Furthermore, it is shown that high energy proton accelerator spectra are capable of producing dopants required for magnetic and neutron detection applications, although not of the concentrations required for current applications using available irradiation methods.

36 MATERIALS SCIENCE↗

Proton Beam Formation at Fermilab for mu2e (and for NF/MC)

Proton bunch formation from the Fermilab proton sources for the mu2e experiment is discussed. In the initial scenario a single intense h = 1 bunch is formed in the Accumulator/Debuncher, with slow extraction providing the required spill. However, the mu2e experiment could use h = 4 bunching in the Accumulator rather than h = 1, with the 4 bunches fed one at a time into the more isochronous Debuncher for slow extraction. The h = 4 variant has several advantages and a few disadvantages, and can reduce peak beam intensities, and therefore improve space charge limits. The method can be extended to project X to enable high duty cycle extraction within space charge limits. A further extension should make possible an accumulator/buncher scenario that can provide 8 GeV short bunches for a neutrino factory and/or muon collider scenario.

43 PARTICLE ACCELERATORS↗

Tomography of an ultrafast laser driven proton source

Using a multichannel Thomson spectrometer we have implemented a tomographic approach allowing the reconstruction of the emission characteristic of a laser driven proton source with high energy and spatial resolution. The results demonstrate the complexity of the temporal and spatial characteristics of such a source. The emitted proton beam, which is laminar and divergent at high energies, becomes convergent at low energies. This implies that a fraction of the proton beam having this kinetic energy is emitted in a collimated way from the target at the ''turning point'' between these two behaviors. Only a finite fraction of the target surface is contributing to the ion spectrum, which is measured at a specific angle within the beam cone. Therefore the momentum distribution of the protons in the emitted beam at any point in space can be controlled by determining the proton source area.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation of heavy ion reactions on gas target with GEANT 4

A research program based on the direct measurement of (alpha,p) and (alpha,n) reactions induced by radioactive ion beams in inverse kinematics of astrophysical interest is to be initiated at the Pelletron laboratory in Sao Paulo. These alpha-induced reactions are present in many astrophysical environments such as those leading to X-ray bursts, the rapid proton-capture (rp-) process, hot pp-cycle in massive stars. Radioactive ion beams and a {sup 4}He gas target are required to investigate such kind of reactions. The gaseous helium target will be cooled down to the nitrogen liquid temperature (70 K) to increase its density. Simulations of such reactions by Monte Carlo technique, using GEANT4, a toolkit written in object oriented language (C++), is being used to obtain informations on the geometrical as well as dynamic parameters for this gas target before we construct it.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗