Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION LENGTH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Observations of enhanced OTR signals from a compressed electron beam

The Advanced Photon Source (APS) injector complex includes an option for photocathode (PC) gun beam injection into the 450-MeV S-band linac. At the 150-MeV point, a 4-dipole chicane was used to compress the micropulse bunch length from a few ps to sub 0.5 ps (FWHM). Noticeable enhancements of the optical transition radiation (OTR) signal sampled after the APS chicane were then observed as has been reported in LCLS injector commissioning. A FIR CTR detector and interferometer were used to monitor the bunch compression process and correlate the appearance of localized spikes of OTR signal (5 to 10 times brighter than adjacent areas) within the beam image footprint. We have done spectral dependency measurements at 375 MeV with a series of band pass filters centered in 50-nm increments from 400 to 700 nm and observed a broadband enhancement in these spikes. Discussions of the possible mechanisms will be presented.

43 PARTICLE ACCELERATORS↗

Characterization of Second Harmonic Afterburner Radiation at the LCLS

During commissioning of the Linac Coherent Light Source (LCLS) x-ray Free Electron Laser (FEL) at the SLAC National Accelerator Laboratory it was shown that saturation lengths much shorter than the installed length of the undulator line can routinely be achieved. This frees undulator segments that can be used to provide enhanced spectral properties and at the same time, test the concept of FEL Afterburners. In December 2009 a project was initiated to convert undulator segments at the down-beam end of the undulator line into Second Harmonic Afterburners (SHAB) to enhance LCLS radiation levels in the 10-20 keV energy range. This is being accomplished by replacement of gap-shims increasing the fixed gaps from 6.8 mm to 9.9 mm, which reduces their K values from 3.50 to 2.25 and makes the segments resonant at the second harmonic of the upstream unmodified undulators. This paper reports experimental results of the commissioning of the SHAB extension to LCLS.

43 PARTICLE ACCELERATORS↗

Microstrip Patch Antenna And Method

Method and apparatus are provided for a microstrip feeder structure for supplying properly phased signals to each radiator element in a microstrip antenna array that may be utilized for radiating circularly polarized electromagnetic waves. In one disclosed embodiment. the microstrip feeder structure includes a plurality of microstrip sections many or all of which preferably have an electrical length substantially equal to one-quarter wavelength at the antenna operating frequency. The feeder structure provides a low loss feed structure that may be duplicated multiple times through a set of rotations and translations to provide a radiating array of the desired size.

Patrick W Fink↗

Straight Line Geometric Path Lengths – Examples and Distributions

The straight line geometric path distribution of different shapes is a fundamental parameter of any a detector sensitive and in the presence of high energy charged particles such as galactic cosmic rays (GCRs). Knowledge of the straight line path distribution can yield first estimates of the expected energy distribution due to minimum ionizing particles. This predicted shape provides a valuable interpretation tool of spectra of particles that are unlikely to stop in a detector and may present a background or desired signal. These quantities have been calculated many times before including analytically, Coleman (1973), and even in Geant4 software, (Agostinelli, Allison et al. 2003, Santin, Ivanchenko et al. 2005). For this work we utilize the Rapid Adaptable Multi-threaded Particle and Radiation Transport (RAMPART) simulation framework and collect some common shapes all with the same volume to serve as a reference of path lengths and instructions manual for computing other shapes as desired.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lunar radiator shade

An apparatus for rejecting waste heat from a system located on or near the lunar equator is presented. The system utilizes a reflective catenary shaped trough deployed about a vertical radiator to shade the radiator from heat emitted by the hot lunar surface. The catenary shaped trough is constructed from a film material and is aligned relative to the sun so that incoming solar energy is focused to a line just above the vertical radiator and can thereby isolate the radiator from the effects of direct sunlight. The film is in a collapsed position between side by side support rods, all of which are in a transport case. To deploy the film and support rods, a set of parallel tracks running perpendicular to length of the support rods are extended out from the transport case. After the support tracks are deployed, the support rods are positioned equidistant from each other along the length of the support tracks so that the flexible film shade between adjacent support rods is unfolded and hangs in a catenary shaped trough. A heat radiator is supported between each pair of support rods above each hanging reflective trough.

Ewert, Michael K.↗

Spectroscopic research of underwater electrical wire explosion

Results of spectroscopic research in the visible range of light of the radiation generated by underwater electrical wire explosions (UEWE) are presented. A pulsed generator with an output voltage of {approx}110 kV, current of {approx}70 kA, and rise time of {approx}60 ns was used for electrical explosion of Cu wires 0.1 mm in diameter and 50 mm in length. It was shown that UEWE is not governed by the 'polarity' effect, which plays an important role in electrical wire explosions in vacuum. The results of detailed space- and time-resolved spectroscopic measurements show that the radiation spectrum differs significantly of the spectrum expected from the exploding wire. A model is suggested based on the formation of a few {mu}m 'water' plasma layer in the vicinity of the exploding wire plasma which efficiently absorbs the radiation of the exploding wire.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Three-dimensional quadratic modeling and quantitative evaluation of the diaphragm on a volumetric CT scan in patients with chronic obstructive pulmonary disease

Purpose: In patients with chronic obstructive pulmonary disease (COPD), diaphragm function may deteriorate due to reduced muscle fiber length. Quantitative analysis of the morphology of the diaphragm is therefore important. In the authors current study, they propose a diaphragm segmentation method for COPD patients that uses volumetric chest computed tomography (CT) data, and they provide a quantitative analysis of the diaphragmatic dimensions. Methods: Volumetric CT data were obtained from 30 COPD patients and 10 normal control patients using a 16-row multidetector CT scanner (Siemens Sensation 16) with 0.75-mm collimation. Diaphragm segmentation using 3D ray projections on the lower surface of the lungs was performed to identify the draft diaphragmatic lung surface, which was modeled using quadratic 3D surface fitting and robust regression in order to minimize the effects of segmentation error and parameterize diaphragm morphology. This result was visually evaluated by an expert thoracic radiologist. To take into consideration the shape features of the diaphragm, several quantification parameters—including the shape index on the apex (SIA) (which was computed using gradient set to 0), principal curvatures on the apex on the fitted diaphragm surface (CA), the height between the apex and the base plane (H), the diaphragm lengths along the x-, y-, and z-axes (XL, YL, ZL), quadratic-fitted diaphragm lengths on the z-axis (FZL), average curvature (C), and surface area (SA)—were measured using in-house software and compared with the pulmonary function test (PFT) results. Results: The overall accuracy of the combined segmentation method was 97.22% ± 4.44% while the visual accuracy of the models for the segmented diaphragms was 95.28% ± 2.52% (mean ± SD). The quantitative parameters, including SIA, CA, H, XL, YL, ZL, FZL, C, and SA were 0.85 ± 0.05 (mm{sup −1}), 0.01 ± 0.00 (mm{sup −1}), 17.93 ± 10.78 (mm), 129.80 ± 11.66 (mm), 163.19 ± 13.45 (mm), 71.27 ± 17.52 (mm), 61.59 ± 16.98 (mm), 0.01 ± 0.00 (mm{sup −1}), and 34 380.75 ± 6680.06 (mm{sup 2}), respectively. Several parameters were correlated with the PFT parameters. Conclusions: The authors propose an automatic method for quantitatively evaluating the morphological parameters of the diaphragm on volumetric chest CT in COPD patients. By measuring not only the conventional length and surface area but also the shape features of the diaphragm using quadratic 3D surface modeling, the proposed method is especially useful for quantifying diaphragm characteristics. Their method may be useful for assessing morphological diaphragmatic changes in COPD patients.

60 APPLIED LIFE SCIENCES↗

Isotropic seismic radiation from rock damage and dilatancy

SUMMARY We present semi-analytical and numerical results on isotropic radiation expected to be generated by seismic sources with damaged dilatant materials that sustain during failure an overall shear deformation. The results are derived for inclusions with different stiffness components, including those responsible for shear-volumetric coupling in dilatant material, and different geometries, in a surrounding elastic solid. The obtained relations indicate that the isotropic seismic potency and seismic moment components are proportional to the shear potency components multiplied by the aspect ratio between the thickness and length of the source zone. For a typical rupture zone with a thin tabular geometry, the expected small aspect ratio explains the general seismological observations of small isotropic radiation. However, isotropic radiation induced by dynamic dilation for short and thick sources is more pronounced and may reach for spherical sources sustaining shear deformation 18 per cent of the shear components. Sources that include also tensile components and explosions can produce larger isotropic radiation. The results provide rigorous relations that can be used to estimate different source properties in numerical simulations, experiments and field studies.

Geochemistry & Geophysics↗

Transport in Random Media With Inhomogeneous Mixing Statistics

The Levermore-Pomraning (LP) model has been investigated for use in implicit Monte Carlo (IMC) algorithms to describe thermal photon transport computations in stochastically mixed cells with material energy coupling. For purely absorbing non-emitting materials, the LP-model is known to predict the exact material averaged fluxes when the mixing statistics are Markovian. In the presence of scattering or reemmission, or if the mixing is non-Markovian, the LP-model is approximate and has greatly diminished accuracy for optically thick, highly scattering materials. Nevertheless, the model enables a robust extension of the simple atomic mix approximation to accommodate spatial correlation effects through well characterized parameters such as mean chord lengths. In this work, we construct exact analytical solutions of the LP-equations for piecewise constant spatial variation of the material chord lengths. It is not possible in general to obtain closed form solutions when the chord lengths are continuous functions of space, although we briefly examine special conditions under which this is feasible. However, by allowing an arbitrarily fine spatial segmentation of the medium it is possible to construct highly refined solutions to fit desired spatial chord length profiles. Material volume fractions that are consistent with the chord lengths are first constructed by solving the associated Chapmann-Kolmogorov equations and applied to obtain the material averaged fluxes in two settings: when the materials are purely absorbing, and when scattering is present in rod model geometry. Illustrative numerical results for the volume fractions and material averaged fluxes are obtained by implementing the algorithms in MATLAB for spatially linear and quadratic variations of the chord lengths.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Initiation-promotion model of tumor prevalence in mice from space radiation exposures

Exposures in space consist of low-level background components from galactic cosmic rays (GCR), occasional intense-energetic solar-particle events, periodic passes through geomagnetic-trapped radiation, and exposure from possible onboard nuclear-propulsion engines. Risk models for astronaut exposure from such diverse components and modalities must be developed to assure adequate protection in future NASA missions. The low-level background exposures (GCR), including relativistic heavy ions (HZE), will be the ultimate limiting factor for astronaut career exposure. We consider herein a two-mutation, initiation-promotion, radiation-carcinogenesis model in mice in which the initiation stage is represented by a linear kinetics model of cellular repair/misrepair, including the track-structure model for heavy ion action cross-sections. The model is validated by comparison with the harderian gland tumor experiments of Alpen et al. for various ion beams. We apply the initiation-promotion model to exposures from galactic cosmic rays, using models of the cosmic-ray environment and heavy ion transport, and consider the effects of the age of the mice prior to and after the exposure and of the length of time in space on predictions of relative risk. Our results indicate that biophysical models of age-dependent radiation hazard will provide a better understanding of GCR risk than models that rely strictly on estimates of the initial slopes of these radiations.

NASA Discipline Radiation Health↗

Local Hypothermia as a Radioprotector of the Rectal Wall During Prostate Stereotactic Body Radiation Therapy

Purpose: To compare the single-fraction dose-related incidence of rectal obstruction and/or bleeding in normothermic and hypothermic rectums of a rat model. Methods and Materials: A 1.9-cm length of rectum was irradiated with a single fraction in 57 Sprague-Dawley rats using a dedicated image-guided small animal irradiator and Monte Carlo–based treatment planning system. All rats had a rectal temperature control apparatus placed during irradiation and were stratified to achieve either a normothermic (37°C) or hypothermic (15°C) rectal wall temperature. Radiation was delivered to a 1-cm-diameter cylindrical volume about the cooling device and rectal wall. The radiation dose was escalated from 16 Gy up to 37 Gy to assess the dose response in each arm. The primary endpoint of this study was rectal obstruction and/or bleeding during a follow-up of 180 to 186 days. Histologic scoring was performed on all study rats. Results: Probit analysis showed a dose associated with a 50% incidence of rectal obstruction of 24.6 Gy and 40.8 Gy for normothermic and hypothermic arms, respectively. The occurrence of obstruction and/or bleeding correlated with the posttreatment histologic score for normothermic rats; however, there was no difference in histologic score between normothermic and hypothermic rats at the highest dose levels evaluated. Conclusions: A significant radioprotective effect was observed using local hypothermia during a single large dose of radiation for the functional endpoint of rectal obstruction and/or bleeding. A confirmatory study in a large animal model with anatomic and physiologic similarities to humans is suggested.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Exciton dynamics at a single dislocation in GaN probed by picosecond time-resolved cathodoluminescence

We investigate the dynamics of donor bound excitons (D°X{sub A}) at T = 10 K around an isolated single edge dislocation in homoepitaxial GaN, using a picosecond time-resolved cathodoluminescence (TR-CL) setup with high temporal and spatial resolutions. An ∼ 1.3 meV dipole-like energy shift of D°X{sub A} is observed around the dislocation, induced by the local strain fields. By simultaneously recording the variations of both the exciton lifetime and the CL intensity across the dislocation, we directly assess the dynamics of excitons around the defect. Our observations are well reproduced by a diffusion model. It allows us to deduce an exciton diffusion length of ∼24 nm as well as an effective area of the dislocation with a radius of ∼95 nm, where the recombination can be regarded as entirely non-radiative.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Channeling, Volume Reection and Gamma Emission Using 14GeV Electrons in Bent Silicon Crystals

High energy electrons can be deflected with very tight bending radius using a bent silicon crystal. This produces gamma radiation. As these crystals can be thin, a series of bent silicon crystals with alternating direction has the potential to produce coherent gamma radiation with reasonable energy of the driving electron beam. Such an electron crystal undulator offers the prospect for higher energy radiation at lower cost than current methods. Permanent magnetic undulators like LCLS at SLAC National Accelerator Laboratory are expensive and very large (about 100 m in case of the LCLS undulator). Silicon crystals are inexpensive and compact when compared to the large magnetic undulators. Additionally, such a high energy coherent light source could be used for probing through materials currently impenetrable by x-rays. In this work we present the experimental data and analysis of experiment T523 conducted at SLAC National Accelerator Laboratory. We collected the spectrum of gamma ray emission from 14 GeV electrons on a bent silicon crystal counting single photons. We also investigated the dynamics of electron motion in the crystal i.e. processes of channeling and volume reflection at 14 GeV, extending and building off previous work. Our single photon spectrum for the amorphous crystal orientation is consistent with bremsstrahlung radiation and the volume reflection crystal orientation shows a trend consistent with synchrotron radiation at a critical energy of 740 MeV. We observe that in these two cases the data are consistent, but we make no further claims because of statistical limitations. We also extended the known energy range of electron crystal dechanneling length and channeling efficiency to 14 GeV.

36 MATERIALS SCIENCE↗

Visualization of ultrafast melting initiated from radiation-driven defects in solids

Materials exposed to extreme radiation environments such as fusion reactors or deep spaces accumulate substantial defect populations that alter their properties and subsequently the melting behavior. The quantitative characterization requires visualization with femtosecond temporal resolution on the atomic-scale length through measurements of the pair correlation function. Here, we demonstrate experimentally that electron diffraction at relativistic energies opens a new approach for studies of melting kinetics. Our measurements in radiation-damaged tungsten show that the tungsten target subjected to 10 displacements per atom of damage undergoes a melting transition below the melting temperature. Two-temperature molecular dynamics simulations reveal the crucial role of defect clusters, particularly nanovoids, in driving the ultrafast melting process observed on the time scale of less than 10 ps. These results provide new atomic-level insights into the ultrafast melting processes of materials in extreme environments.

36 MATERIALS SCIENCE↗

Symmetry control in subscale near-vacuum hohlraums

Controlling the symmetry of indirect-drive inertial confinement fusion implosions remains a key challenge. Increasing the ratio of the hohlraum diameter to the capsule diameter (case-to-capsule ratio, or CCR) facilitates symmetry tuning. By varying the balance of energy between the inner and outer cones as well as the incident laser pulse length, we demonstrate the ability to tune from oblate, through round, to prolate at a CCR of 3.2 in near-vacuum hohlraums at the National Ignition Facility, developing empirical playbooks along the way for cone fraction sensitivity of various laser pulse epochs. Radiation-hydrodynamic simulations with enhanced inner beam propagation reproduce most experimental observables, including hot spot shape, for a majority of implosions. In conclusion, specular reflections are used to diagnose the limits of inner beam propagation as a function of pulse length.

42 ENGINEERING↗

Measurements on the Diffusion Length of Thermal Neutrons in Water from 25 to 296°C

Here, the diffusion length of thermal neutrons has been measured in water over the range 25.9 to 295.3°C in the pressure vessel of the KAPL High Temperature Critical Assembly. The diffusion length was determined by fitting an exponential to the data found by activating manganese foils with neutrons from a small Sb-Be source. The temperature variation of the diffusion length could be fairly well represented by either of two simple approximations—either that the transport cross section of water has a 1/υ behavior, or that the transport cross section is determined from the Radkowsky prescription.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Transition to turbulence and noise radiation in heated coaxial jet flows

Laminar-turbulent transition and noise radiation of a parametrized set of subsonic coaxial jet flows with a hot primary (core) stream are investigated numerically by Large-Eddy Simulation (LES) and direct noise computation. This study extends our previous research on local linear stability of heated coaxial jet flows by analyzing the nonlinear evolution of initially laminar flows disturbed by a superposition of small-amplitude unstable eigenmodes. First, a baseline configuration is studied to shed light on the flow dynamics of coaxial jet flows. Subsequently, LESs are performed for a range of Mach and Reynolds numbers to systematically analyze the influences of the temperature and the velocity ratios between the primary and the secondary (bypass) stream. The results provide a basis for a detailed analysis of fundamental flow-acoustic phenomena in the considered heated coaxial jet flows. Increasing the primary-jet temperature leads to an increase of fluctuation levels and to an amplification of far-field noise, especially at low frequencies. Strong mixing between the cold bypass stream and the hot primary stream as well as the intermittent character of the flow field at the end of the potential core lead to a pronounced noise radiation at an aft angle of approximately 35{sup ∘}. The velocity ratio strongly affects the shear-layer development and therefore also the noise generation mechanisms. Increasing the secondary-stream velocity amplifies the dominance of outer shear-layer perturbations while the disturbance growth rates in the inner shear layer decrease. Already for r{sub mic} > 40R{sub 1}, where r{sub mic} is the distance from the end of the potential core and R{sub 1} is the core-jet radius, a perfect 1/r{sub mic} decay of the sound pressure amplitudes is observed. The potential-core length increases for higher secondary-stream velocities which leads to a shift of the center of the dominant acoustic radiation in the downstream direction.

42 ENGINEERING↗