Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Project X”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

DARPA/USAF/USN J-UCAS X-45A System Demonstration Program: A Review of Flight Test Site Processes and Personnel

The Joint Unmanned Combat Air Systems (J-UCAS) program is a collaborative effort between the Defense Advanced Research Project Agency (DARPA), the US Air Force (USAF) and the US Navy (USN). Together they have reviewed X-45A flight test site processes and personnel as part of a system demonstration program for the UCAV-ATD Flight Test Program. The goal was to provide a disciplined controlled process for system integration and testing and demonstration flight tests. NASA's Dryden Flight Research Center (DFRC) acted as the project manager during this effort and was tasked with the responsibilities of range and ground safety, the provision of flight test support and infrastructure and the monitoring of technical and engineering tasks. DFRC also contributed their engineering knowledge through their contributions in the areas of autonomous ground taxi control development, structural dynamics testing and analysis and the provision of other flight test support including telemetry data, tracking radars, and communications and control support equipment. The Air Force Flight Test Center acted at the Deputy Project Manager in this effort and was responsible for the provision of system safety support and airfield management and air traffic control services, among other supporting roles. The T-33 served as a J-UCAS surrogate aircraft and demonstrated flight characteristics similar to that of the the X-45A. The surrogate served as a significant risk reduction resource providing mission planning verification, range safety mission assessment and team training, among other contributions.

Cosentino, Gary B.↗

Improved proton computed tomography by dual modality image reconstruction

Purpose: Proton computed tomography (CT) is a promising image modality for improving the stopping power estimates and dose calculations for particle therapy. However, the finite range of about 33 cm of water of most commercial proton therapy systems limits the sites that can be scanned from a full 360° rotation. In this paper the authors propose a method to overcome the problem using a dual modality reconstruction (DMR) combining the proton data with a cone-beam x-ray prior. Methods: A Catphan 600 phantom was scanned using a cone beam x-ray CT scanner. A digital replica of the phantom was created in the Monte Carlo code Geant4 and a 360° proton CT scan was simulated, storing the entrance and exit position and momentum vector of every proton. Proton CT images were reconstructed using a varying number of angles from the scan. The proton CT images were reconstructed using a constrained nonlinear conjugate gradient algorithm, minimizing total variation and the x-ray CT prior while remaining consistent with the proton projection data. The proton histories were reconstructed along curved cubic-spline paths. Results: The spatial resolution of the cone beam CT prior was retained for the fully sampled case and the 90° interval case, with the MTF = 0.5 (modulation transfer function) ranging from 5.22 to 5.65 linepairs/cm. In the 45° interval case, the MTF = 0.5 dropped to 3.91 linepairs/cm For the fully sampled DMR, the maximal root mean square (RMS) error was 0.006 in units of relative stopping power. For the limited angle cases the maximal RMS error was 0.18, an almost five-fold improvement over the cone beam CT estimate. Conclusions: Dual modality reconstruction yields the high spatial resolution of cone beam x-ray CT while maintaining the improved stopping power estimation of proton CT. In the case of limited angles, the use of prior image proton CT greatly improves the resolution and stopping power estimate, but does not fully achieve the quality of a 360° proton CT scan.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of Thermal Kinetic Inductance Detectors Suitable for X-ray Spectroscopy

We report on the development of thermal kinetic inductance detectors (TKIDs) suitable to perform X-ray spectroscopy measurements. The aim is to implement MKIDs sensors working in thermal quasi-equilibrium mode to detect X-ray photons as pure calorimeters. The thermal mode is a variation on the MKID classical way of operation that has generated interest in recent years. TKIDs can offer the MKIDs inherent multiplexibility in the frequency domain, a high spatial resolution comparable with CCDs, and an energy resolution theoretically limited only by thermodynamic fluctuations across the thermal weak links. Microresonators are built in Ti/TiN multilayer technology with the inductive part thermally coupled with a metal absorber on a suspended SiN membrane, to avoid escape of phonons from the film to the substrate. The mid-term goal is to optimize the single-pixel design in terms of superconducting critical temperatures, internal quality factors, kinetic inductance and spectral energy resolution. The final goal is to realize a demonstrator array for a next generation thousand pixels X-ray spectrometer. In this contribution, the status of the project after one year of developments is reported, with detailed reference to the microresonators design and simulations and to the fabrication process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-I-15: Comparison of Radiation Dose for Radiography and EOS in Adolescent Scoliosis Patients

Purpose: To estimate patient radiation dose for whole spine imaging using EOS, a new biplanar slot-scanning radiographic system and compare with standard scoliosis radiography. Methods: The EOS imaging system (EOS Imaging, Paris, France) consists of two orthogonal x-ray fan beams which simultaneously acquire frontal and lateral projection images of a standing patient. The patient entrance skin air kerma was measured for each projection image using manufacturer-recommended exposure parameters for spine imaging. Organ and effective doses were estimated using a commercially-available Monte Carlo simulation program (PCXMC, STUK, Radiation and Nuclear Safety Authority, Helsinki, Finland) for a 15 year old mathematical phantom model. These results were compared to organ and effective dose estimated for scoliosis radiography using computed radiography (CR) with standard exposure parameters obtained from a survey of pediatric radiographic projections. Results: The entrance skin air kerma for EOS was found to be 0.18 mGy and 0.33 mGy for posterior-anterior (PA) and lateral projections, respectively. This compares to 0.76 mGy and 1.4 mGy for CR, PA and lateral projections. Effective dose for EOS (PA and lateral projections combined) is 0.19 mSv compared to 0.51 mSv for CR. Conclusion: The EOS slot-scanning radiographic system allows for reduced patient radiation dose in scoliosis patients as compared to standard CR radiography.

60 APPLIED LIFE SCIENCES↗

Short pulse, high resolution, backlighters for point projection high-energy radiography at the National Ignition Facility

High-resolution, high-energy X-ray backlighters are very active area of research for radiography experiments at the National Ignition Facility (NIF) [Miller et al., Nucl. Fusion 44, S228 (2004)], in particular those aiming at obtaining Compton-scattering produced radiographs from the cold, dense fuel surrounding the hot spot. We report on experiments to generate and characterize point-projection-geometry backlighters using short pulses from the advanced radiographic capability (ARC) [Crane et al., J. Phys. 244, 032003 (2010); Di Nicola et al., Proc. SPIE 2015, 93450I-12], at the NIF, focused on Au micro-wires. We show the first hard X-ray radiographs, at photon energies exceeding 60 keV, of static objects obtained with 30 ps-long ARC laser pulses, and the measurements of strength of the X-ray emission, the pulse duration and the source size of the Au micro-wire backlighters. For the latter, a novel technique has been developed and successfully applied.

42 ENGINEERING↗

Simultaneous probing of phase transformations in Ni-Ti thin film shape memory alloy by synchrotron radiation-based X-ray diffraction and electrical resistivity

Nickel–Titanium (Ni–Ti) thin film shape memory alloys (SMAs) have been widely projected as novel materials which can be utilized in microdevices. Characterization of their physical properties and its correlation with phase transformations has been a challenging issue. In the present study, X-ray beam diffraction has been utilized to obtain the structural information at different temperatures while cooling. Simultaneously, electrical resistivity (ER) was measured in the phase transformation temperature range. The variation of ER and integral area of the individual diffraction peaks of the different phases as a function of temperature have been compared. A mismatch between the conventional interpretation of ER variation and the results of the XRD data has been clearly identified. - Highlights: ► Phase transformation characterization of Ni–Ti thin film SMA has been carried out. ► Simultaneous monitoring of the XRD and ER with temperature is performed. ► The variation of ER and integral area of the diffraction peaks have been compared. ► A shift of the transformation temperatures obtained by two techniques is discussed.

36 MATERIALS SCIENCE↗

Latest experiences and future plans on NSLS-II insertion devices

National Synchrotron Light Source-II (NSLS-II) is the latest storage ring of 3 GeV energy at the Brookhaven National Laboratory (BNL). The horizontal emittance of the electron beam with the currently installed six damping wigglers is 0.9 nm.rad, which could be further reduced to 0.5 nm.rad with more insertion devices (IDs). With only one RF cavity the beam current is restricted to 200 mA. Five hundred mA operation is envisaged for next year with an addition of the second cavity. Six (plus two branches) beamlines have been commissioned in the initial phase of the project. In July 2015, three NIH funded beamlines called “Advanced Beamlines for Biological Investigations with X-rays” (ABBIX) will be added for operation. This paper describes the experiences of ID development, installation, and commissioning for the NSLS-II project as well as our future plans to improve the performance of the facility in terms of source development.

43 PARTICLE ACCELERATORS↗

A New Method to Use Chandra Data to Resolve the X-Ray Halos Around Point Sources and Its Application to Cygnus X-1

The excellent angular resolution, good energy resolution and broad energy band make Chandra ACIS the best instrument for studying the X-ray halos around some galactic x-ray point sources caused by the dust scattering of X-rays in the interstellar medium, but direct images of bright sources of b r i g h t sources obtained with ACIS usually from severe pile- UP - Making use of the fact that an isotropic image could be reconstructed from it's projection on any direction, we can reconstruct the images of the X-ray halos from data obtained with the regular HETGS and/or the CC mode. With the reconstructed high resolution images, we can probe the X-ray halos as close as 1 arcsecond to their associated point sources.

Yao, Y.↗

Non-Rare Earth Magnesium Bumper Beams

Magna will team with the Pacific Northwest National Laboratory (PNNL) to develop Shear Assisted Processing and Extrusion (ShAPE™) of rectangular and multi-zoned extrusion profiles using non-RE Mg. It is envisioned that the ShAPE™ process, developed during this project for non-circular profiles, will serve as the foundation for fabrication of full-scale bumper beams of the future where near net-shapes are extruded directly from castings in a single step, without the need for costly rare earth additives. In this project, the ShAPE™ process will be developed for a rectangular profile measuring 1” x 2” with a 0.06” wall thickness. Successful extrusion of rectangular cross sections is a critical step along the path toward profiles with multiple zones. With the process established for a rectangular profile, the project will then make advancements toward multi-zoned cross sections. A magnesium alloy bumper beam offers a 35% weight savings compared to aluminum alloys and 60% compared to high strength steels. The bumper beam was chosen as the first component to target because the geometry can have a fairly simple 0.6-0.12 inch wall/web thickness, generally compatible with PNNL’s knowledge base and equipment capability surrounding ShAPE™. The bumper component offers commercial value by providing mass reduction in the front of the vehicle along with ride and handling benefit. PNNL has demonstrated the ability to ShAPE™ process non-RE Mg tubing with high strength, ductility and energy absorption. It has been shown that ShAPE™ extruded ZK60 and Mg2Si tubing with 0.30 inch diameter and 0.03 inch wall thickness have similar energy absorption to AA6061-T6. This is due to significant grain refinement, breakdown and dispersion of second phases, and the ability to eliminate anisotropy in compressive/tensile strength by aligning texture 45 degrees to the extrusion axis. Scalability of the ShAPE™ process has been demonstrated in ZK60 by fabricating 2.0 inch diameter tubing with 0.06 and 0.12 inch wall thicknesses having concentricity as tight as 1.3%. These tubes exhibit an ultimate tensile strength of 260-300 MPa and room temperature ductility of >20% parallel, perpendicular and 45 degrees to the extrusion axis. Aluminum bumpers represent approximately 54% of the NA light vehicle market. If the research effort is successful, providing a 30% mass reduction at equal cost relative to aluminum bumpers, it is anticipated that 25% market penetration would be realized over the next 5 year and 50% market share by 2030. 100% of the aluminum automotive bumpers are sourced from the tier network, providing resourcing opportunity based on equal performance, reduced mass and cost equivalent lower than aluminum bumpers. Due to the relatively low vehicle content, magnesium components are currently shredded and 100% recycled with aluminum content in the US, presenting a positive life cycle impact.

42 ENGINEERING↗

Assessing the Geomechanical Response of CO 2 Disposal in Flood Basalt Reservoirs

In this work, we complete a multi-scale investigation of the physical processes governing geologic CO 2 sequestration in basalt reservoirs. This work integrates (i) laboratory measurements of relative permeability in a basalt fracture, (ii) theoretical modeling to understand how relative permeability uncertainty affects geomechanical performance attributes of basalt reservoirs, (iii) outcrop-scale simulation to identify the characteristics of vertical CO 2 flow in a basalt fracture network, and (iv) regional-scale assessment of permeability architecture in the Columbia River Basalt Group (CRBG). These individual studies are combined into a site-scale stochastic model of geologic CO 2 sequestration in the Columbia River Plateau, which shows how bulk and relative permeability variability affects geomechanical reservoir integrity and storage capacity of flood basalt reservoirs. This project resulted in a novel laboratory technique that combines X-ray CT and micro-PET scanning to calculate the relative permeability curves for a horizontal fracture in basalt. We also discovered that permeability on the Columbia River Plateau exhibits directionally-dependent spatial correlation, which our analysis suggests is a result of loading-induced subsidence. This analysis further discovered that permeability in the CRBG may increase at depth due to bending moment stresses. In the context of CO 2 sequestration, this result implies that storage capacity and injectivity may actually increase at depths beyond ~1 km. Our outcrop-scale investigation found that buoyant, free-phase CO 2 tends to accumulate at fracture intersections, which inhibits vertical flow over 10+ year timescales and may facilitate both physical and chemical trapping as fluid mobility decreases. At the site-scale, we find that in flood basalt reservoirs the spatial configuration of reservoir permeability exhibits substantial control on CO 2 injectivity. We utilized known borehole geology from the Wallula Basalt Sequestration Pilot Project to develop 50 equally probable permeability configurations and found that a single injection well operating at 95% of the borehole breakout pressure can deliver 0.12 to 2.0 million metric tons of CO 2 per year (MMT CO 2 per year). This maximum injection rate can support a 1,000 MW gas-fired power plant with a single injection well.

58 GEOSCIENCES↗

Time-resolved x-ray radiography of spark ignition plasma

Understanding the short-lived structure of the plasma that forms between the electrodes of a spark plug is crucial to the development of improved ignition models for SI engines. However, measuring the amount of energy deposited in the gas directly and non-intrusively is difficult, due to the short time scales and small length scales involved. The breakdown of the spark gap occurs at nanosecond time scales, followed by an arc phase lasting a few microseconds. Finally, a glow discharge phase occurs over several milliseconds. It is during the arc and glow discharge phases that most of the heat transfer from the plasma to the electrodes and combustion gases occurs. Light emission can be used to measure an average temperature, but micron spatial resolution is required to make localized measurements. In this paper, we present the results of a proof of concept experiment that demonstrates the use of time-resolved x-ray radiography to measure the density of the plasma in the spark gap during the glow discharge phase of a conventional transistorized coil ignition system. A focused monochromatic x-ray beam from the 7-BM beamline of the Advanced Photon Source at Argonne National Laboratory was used to make time-resolved point measurements of the projected density, which decreases as the plasma temperature increases. Multiple measurement positions were combined to produce a two-dimensional map of the projected density both inside and surrounding the spark gap. A temporal resolution of 153 ns and spatial resolution of 5 μm were achieved. A range of ambient gases, densities (1 - 3 bar) and ignition coil charging durations (1 - 2.5 ms) were considered. At least 30 repeated measurements were made for each sample point and condition. All these parameters were found to substantially alter the structure of the plasma as measured by x-ray radiography. From the projected density measurements, changes in thermal energy can be calculated. These provide a quantitative measurement of the energy deposited into the gas; this is only a small fraction of the total spark energy. The measurements demonstrate the feasibility of time-resolved x-ray radiography for the study of plasma structure and development for SI applications.

Kastengren, Alan L.↗

Development of a backlit-multi-pinhole radiography source

Backlit-pinhole radiography uses a pinhole placed between an x-ray source and a sample. The backlit- multi-pinhole design uses two pinholes on the same substrate, which are separated by a wall, to create two radiographic images projected along similar axes. The wall, a 100-μm thick titanium foil, prevents x-rays generated near one pinhole from exiting the other pinhole. First results indicate that the multi- pinhole target can create two independent radiographs along similar axes. Furthermore, the images are recorded 2 ns apart. Details of our multi-pinhole design and our first results are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SPIDERS: the spectroscopic follow-up of X-ray-selected clusters of galaxies in SDSS-IV

SPIDERS (The SPectroscopic IDentification of ERosita Sources) is a programme dedicated to the homogeneous and complete spectroscopic follow-up of X-ray active galactic nuclei and galaxy clusters over a large area (~7500 deg 2 ) of the extragalactic sky. SPIDERS is part of the Sloan Digital Sky Survey (SDSS)-IV project, together with the Extended Baryon Oscillation Spectroscopic Survey and the Time-Domain Spectroscopic Survey. This study describes the largest project within SPIDERS before the launch of eROSITA: an optical spectroscopic survey of X-ray-selected, massive (~10 14 –10 15 M⊙) galaxy clusters discovered in ROSAT and XMM–Newton imaging. The immediate aim is to determine precise (Δz ~ 0.001) redshifts for 4000–5000 of these systems out to z ~ 0.6. The scientific goal of the program is precision cosmology, using clusters as probes of large-scale structure in the expanding Universe. We present the cluster samples, target selection algorithms and observation strategies. We demonstrate the efficiency of selecting targets using a combination of SDSS imaging data, a robust red-sequence finder and a dedicated prioritization scheme. We describe a set of algorithms and work-flow developed to collate spectra and assign cluster membership, and to deliver catalogues of spectroscopically confirmed clusters. We discuss the relevance of line-of-sight velocity dispersion estimators for the richer systems. We illustrate our techniques by constructing a catalogue of 230 spectroscopically validated clusters (0.031 < z < 0.658), found in pilot observations. Finally, we discuss two potential science applications of the SPIDERS sample: the study of the X-ray luminosity-velocity dispersion (LX–σ) relation and the building of stacked phase-space diagrams.

79 ASTRONOMY AND ASTROPHYSICS↗

X-RAY POLARIZATION FROM HIGH-MASS X-RAY BINARIES

X-ray astronomy allows study of objects that may be associated with compact objects, i.e., neutron stars or black holes, and also may contain strong magnetic fields. Such objects are categorically nonspherical, and likely noncircular when projected on the sky. Polarization allows study of such geometric effects, and X-ray polarimetry is likely to become feasible for a significant number of sources in the future. Potential targets for future X-ray polarization observations are the high-mass X-ray binaries (HMXBs), which consist of a compact object in orbit with an early-type star. In this paper we show that X-ray polarization from HMXBs has a distinct signature that depends on the source inclination and orbital phase. The presence of the X-ray source displaced from the star creates linear polarization even if the primary wind is spherically symmetric whenever the system is viewed away from conjunction. Direct X-rays dilute this polarization whenever the X-ray source is not eclipsed; at mid-eclipse the net polarization is expected to be small or zero if the wind is circularly symmetric around the line of centers. Resonance line scattering increases the scattering fraction, often by large factors, over the energy band spanned by resonance lines. Real winds are not expected to be spherically symmetric, or circularly symmetric around the line of centers, owing to the combined effects of the compact object gravity and ionization on the wind hydrodynamics. A sample calculation shows that this creates polarization fractions ranging up to tens of percent at mid-eclipse.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterizing X-ray Attenuation of Containerized Cargo

X-ray inspection systems can be used to detect radiological and nuclear threats in imported cargo. In order to better understand performance of these systems, the attenuation characteristics of imported cargo need to be determined. This project focused on developing image processing algorithms for segmenting cargo and using x-ray attenuation to quantify equivalent steel thickness to determine cargo density. These algorithms were applied to over 450 cargo radiographs. The results are summarized in this report.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A New Method to Resolve X-Ray Halos around Point Sources with Chandra Data and Its Application to Cygnus X-1

With excellent angular resolution, good energy resolution, and a broad energy band, the Chandra Advanced CCD Imaging Spectrometer (ACIS) is the best instrument for studying the X-ray halos around some Galactic X-ray point sources caused by the dust scattering of X-rays in the interstellar medium. However, the direct images of bright sources obtained with the ACIS usually suffer from severe pileup. Making use of the fact that an isotropic image could be reconstructed from its projection in to any direction, we can reconstruct the images of the X-ray halos from the data obtained with the High Energy Transition Grating Spectrometer (HETGS) and/or in continuos clocking (CC) mode. These data have no or less serious pileup and enable us to take full advantage of the excellent angular resolution of Chandra. With the reconstructed high-resolution images, we can probe the X-ray halos as close as 1" to their associated point sources. Applying this method to Cygnus X-1 observed with the Chandra HETGS in CC mode, we derived an energy-dependent radial halo flux distribution and concluded that in a circular region (2' in radius) centered a the point source: (1) relative to the total intensity, the fractional halo intensity is about 15% at keV and drops to aboout 5% at approximately 6 keV (2) about 50% of the halo photons are within the region of a radius less than 40 inches and (3) the spectrum of the pooint source is slightly distorted by the halo contamination.

Yao, Yangsen↗

Fast camera imaging of plasmas in Alcator C-Mod and W7-X

In this work we present an analysis of fast-camera imaging of Alcator C-Mod's divertor region and of the plasma cross section in the W7-X stellarator. In C-Mod, the dynamics of intermittent edge plasma filaments are imaged at 397,100 frames per second in an oblique view. An automatic pipeline was developed to reconstruct the filament motion in the R, Z plane of the divertor using EFIT field line projections. Next, we added our fast-framing camera to W7-X's diagnostic suite for the 2017 run campaign, the first with a divertor. It has a tangential view of the machine cross section, including part of a divertor module. The view is coupled to the camera via a coherent fiber bundle. The spatial resolution is 2–4 cm and the typical plasma brightness limits the fastest usable frame rate to 30k frames/s. We observe filaments in the plasma boundary that rotate around the magnetic axis during radiative collapse; filaments were observed in steady state in the limiter configuration of W7-X by Kocsis et al. [1]. We also observe for the first time a 1–2 kHz quasi-coherent fluctuation in divertor target emissions in the W7-X “standard” magnetic configuration. Finally, a rough analysis of edge gas fueling efficiency using fast camera data and S/XB coefficients finds that fueling is less efficient at densities higher than 4 × 10 19 m -3 .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experimental and theoretical investigation of the rocking curves measured for MoK{sub α} X-ray characteristic lines in the double-crystal nondispersive scheme

The rocking curves (RCs) for MoK{sub α1} and MoK{sub α2} characteristic X-ray lines have been experimentally and theoretically studied in the nondispersive scheme of an X-ray double-crystal TPC-K diffractometer. The results of measurements and theoretical calculations of double-crystal RCs for characteristic X-rays from tubes with a molybdenum anode and different widths of slits show that a decrease in the slit width leads to an increase in the relative contribution of the MoK{sub α2}-line RC in comparison with the intensity of the tails of the MoK{sub α1}-line RC. It is shown that the second peak of the MoK{sub α2} line becomes increasingly pronounced in the tail of the MoK{sub α1}-line RC with a decrease in the slit width. Two plane-parallel Si plates (input faces (110), diffraction vector h 〈220〉) were used as a monochromator crystal and a sample. The results of measuring double-crystal RCs are in good agreement with theoretical calculations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗