Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Position resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

On the structure and microstructure of 'PbCrO{sub 3}'

The reliability factors of a Rietveld X-ray powder refinement of PbCrO{sub 3} could be improved by considering the lead ion in a multi-minimum potential displaced from its special position. These studies coupled to EDX analysis show a certain lead deficiency. Electron diffraction and high-resolution electron microscopy reveal that the microstructure of this material is a rather complex perovskite superstructure that presents a compositional modulation, within a microdomain distribution. The proposed supercell is {approx}a{sub p}x3a{sub p}x({approx}14-18)a{sub p}. - Graphical abstract: Model of the structure of PbCrO{sub 3} obtained by electron microscopy and diffraction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

First experimental measurements with the Segmented Inverted-coaxial GerMAnium (SIGMA) detector

The SIGMA project aims to develop a p-type segmented inverted coaxial point contact germanium detector for gamma-ray tracking and imaging. Here the performance of the first prototype of this type of detector is reported. The measurements performed verified the size and shape of the crystal and determined the location of the complex active volumes of the detector segments. The latter determines the charge collection times that are related to the position of interaction. Good agreement is found between the results and the specified crystal design. The energy resolution of the point contact has been measured to be 0.84 keV and 2.21 keV at 122 keV and 1332 keV, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extending Interfaces in 3D to Achieve Superior Nanoscale Strength in Ti/Nb Nanolaminates

Tuning the atomic-level structure of nanolaminates enables high strength, increased deformability, and the ability to absorb and mitigate damage due to varied crystalline defects, including dislocations. Here, we present the enhanced strength of Ti/Nb nanolaminates containing thick 3D interfaces (3DIs), relative to their chemically abrupt 2D counterparts. We examine the effects of crystallographic alignment and compositional gradients on mechanical behavior via experiments and phase-field-dislocation dynamics (PFDD) modeling. Mechanical testing reveals that nanolaminates containing thicker 3DIs demonstrate a 28% hardness enhancement compared with sharp-interface nanolaminates. PFDD modeling shows that the critical resolved shear stress (CRSS) increases with the 3DI thickness. Gradual compositional transitions in 3DIs were confirmed via scanning transmission electron microscopy and high-resolution transmission electron microscopy, showing sharp crystallographic transitions and a heightened interface topography. The findings establish a positive function between the 3DI thickness and mechanical robustness for hexagonal-closest-packed-containing composites, emphasizing the role of defect–interface interactions in tailoring the mechanical performance and providing a foundation for future interfacial engineering.

36 MATERIALS SCIENCE↗

Understanding capacity fade in organic redox-flow batteries by combining spectroscopy with statistical inference techniques

Organic redox-active molecules are attractive as redox-flow battery (RFB) reactants because of their low anticipated costs and widely tunable properties. Unfortunately, many lab-scale flow cells experience rapid material degradation (from chemical and electrochemical decay mechanisms) and capacity fade during cycling (>0.1%/day) hindering their commercial deployment. In this work, we combine ultraviolet-visible spectrophotometry and statistical inference techniques to elucidate the Michael attack decay mechanism for 4,5-dihydroxy-1,3-benzenedisulfonic acid (BQDS), a once-promising positive electrolyte reactant for aqueous organic redox-flow batteries. We use Bayesian inference and multivariate curve resolution on the spectroscopic data to derive uncertainty-quantified reaction orders and rates for Michael attack, estimate the spectra of intermediate species and establish a quantitative connection between molecular decay and capacity fade. Our work illustrates the promise of using statistical inference to elucidate chemical and electrochemical mechanisms of capacity fade in organic redox-flow battery together with uncertainty quantification, in flow cell-based electrochemical systems.

25 ENERGY STORAGE↗

Ancient co-option of LTR retrotransposons as yeast centromeres

Centromeres ensure accurate chromosome segregation, yet their DNA evolves rapidly across eukaryotes leaving the origins of new centromere architectures unclear. The brewer’s yeast Saccharomyces cerevisiae exemplifies this long-standing puzzle. Its centromeres shifted ancestrally from large, repeat-rich, epigenetically specified forms to the compact, genetically defined ‘point’ centromeres. How this transition occurred has remained unresolved6. Here we identify evolutionarily related ‘proto-point’ centromeres that provide a resolution to the evolutionary origins of point centromeres. Proto-point centromeres contain a single centromeric nucleosome positioned over an AT-rich core, accompanied by relaxed organization and sequence variability of flanking cis-elements. In two species, these proto-point centromeres lie within retrotransposon-derived repeat clusters, linking ancestral repeat-rich centromeres to genetically encoded ones. Comparative and phylogenetic analyses indicate that proto-point and point centromeres evolved in an ancestor with retrotransposon-rich centromeres. These results identify long-terminal-repeat retrotransposons, specifically Ty5 sequences, as the genetic substrate for point-centromere evolution and provide a mechanistic route by which an epigenetic centromere can become genetically specified. More broadly, they show how selfish elements can be co-opted to perform essential chromosomal functions.

Haase, Max A. B. [Max Planck Institute of Molecula↗

Revisiting the hydration structure of aqueous Na +

In this paper, a combination of theory, X-ray diffraction (XRD) and extended x-ray absorption fine structure (EXAFS) are used to probe the hydration structure of aqueous Na + . The high spatial resolution of the XRD measurements corresponds to Qmax = 24 Å –1 while the first-reported Na K-edge EXAFS measurements have a spatial resolution corresponding to 2k = Qmax = 16 Å –1 . Both provide an accurate measure of the shape and position of the first peak in the Na–O pair distribution function, g NaO (r). The measured Na–O distances of 2.384 ± 0.003 Å (XRD) and 2.37 ± 0.024 Å (EXAFS) are in excellent agreement. These measurements show a much shorter Na–O distance than generally reported in the experimental literature (Na–O avg ~ 2.44 Å) although the current measurements are in agreement with recent neutron diffraction measurements. The measured Na–O coordination number from XRD is 5.5 ± 0.3. The measured structure is compared with both classical and first-principles density functional theory (DFT) simulations. Both of the DFT-based methods, revPBE and BLYP, predict a Na–O distance that is too long by about 0.05 Å with respect to the experimental data (EXAFS and XRD). The inclusion of dispersion interactions (–D3 and –D2) significantly worsens the agreement with experiment by further increasing the Na–O distance by 0.07 Å. In contrast, the use of a classical Na–O Lennard-Jones potential with SPC/E water accurately predicts the Na–O distance as 2.39 Å although the Na–O peak is over-structured with respect to experiment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-resolution structure of RGS17 suggests a role for Ca 2+ in promoting the GTPase-activating protein activity by RZ subfamily members

Regulator of G protein signaling (RGS) proteins are negative regulators of G protein–coupled receptor (GPCR) signaling through their ability to act as GTPase-activating proteins (GAPs) for activated Gα subunits. Members of the RZ subfamily of RGS proteins bind to activated Gα o , Gα z , and Gα i1–3 proteins in the nervous system and thereby inhibit downstream pathways, including those involved in Ca 2+ -dependent signaling. In contrast to other RGS proteins, little is known about RZ subfamily structure and regulation. In this study, we present the 1.5-Å crystal structure of RGS17, the most complete and highest-resolution structure of an RZ subfamily member to date. RGS17 cocrystallized with Ca 2+ bound to conserved positions on the predicted Gα-binding surface of the protein. Using NMR chemical shift perturbations, we confirmed that Ca 2+ binds in solution to the same site. Furthermore, RGS17 had greater than 55-fold higher affinity for Ca 2+ than for Mg 2+ . Finally, we found that Ca 2+ promotes interactions between RGS17 and activated Gα and decreases the K m for GTP hydrolysis, potentially by altering the binding mechanism between these proteins. Taken together, these findings suggest that Ca 2+ positively regulates RGS17, which may represent a general mechanism by which increased Ca 2+ concentration promotes the GAP activity of the RZ subfamily, leading to RZ-mediated inhibition of Ca 2+ signaling.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

tRNA shape is an identity element for an archaeal pyrrolysyl-tRNA synthetase from the human gut

Protein translation is orchestrated through tRNA aminoacylation and ribosomal elongation. Among the highly conserved structure of tRNAs, they have distinguishing features which promote interaction with their cognate aminoacyl tRNA synthetase (aaRS). These key features are referred to as identity elements. In our study, we investigated the tRNA:aaRS pair that installs the 22nd amino acid, pyrrolysine (tRNAPyl:PylRS). Pyrrolysyl-tRNA synthetases (PylRSs) are naturally encoded in some archaeal and bacterial genomes to acylate tRNAPyl with pyrrolysine. Their large amino acid binding pocket and poor recognition of the tRNA anticodon have been instrumental in incorporating > 200 noncanonical amino acids. PylRS enzymes can be divided into three classes based on their genomic structure. Two classes contain both an N-terminal and C-terminal domain, however the third class (ΔpylSn) lacks the N-terminal domain. In this study we explored the tRNA identity elements for a ΔpylSn tRNAPyl from Candidatus Methanomethylophilus alvus which drives the orthogonality seen with its cognate PylRS (MaPylRS). From aminoacylation and translation assays we identified five key elements in ΔpylSn tRNAPyl necessary for MaPylRS activity. The absence of a base (position 8) and a G–U wobble pair (G28:U42) were found to affect the high-resolution structure of the tRNA, while molecular dynamic simulations led us to acknowledge the rigidity imparted from the G–C base pairs (G3:C70 and G5:C68).

59 BASIC BIOLOGICAL SCIENCES↗

Structural insights into RNA duplexes with multiple 2'-5'-linkages

2 -5 -linked RNAs play important roles in many biological systems. In addition, the mixture of 2 -5 and 3 -5 phosphodiester bonds have emerged as a plausible structural element in prebiotic RNAs. Toward our mechanistic studies of RNA folding and structures with heterogeneous backbones, we recently reported two crystal structures of a decamer RNA duplex containing two and six 2 -5 -linkages, showing how RNA duplexes adjust the structures to accommodate these non-canonical linkages (Proc. Natl. Acad. Sci. USA, 2014, 111, 3050–3055). Herein, we present two additional high-resolution crystal structures of the same RNA duplex containing four and eight 2 -5 -linkages at different positions, providing new insights into the effects of these modifications and a dynamic view of RNA structure changes with increased numbers of 2 -5 -linkages in the same duplex. Our results show that the local structural perturbations caused by 2 -5 linkages can be distributed to nearly all the nucleotides with big ranges of changes in different geometry parameters. In addition, hydration pattern and solvation energy analysis indicate less favorable solvent interactions of 2 -5 -linkages comparing to the native 3 -5 -linkages. This study not only promotes our understanding of RNA backbone flexibility, but also provides a knowledge base for studying the biochemical and prebiotic significance of RNA 2 -5 -linkages.

59 BASIC BIOLOGICAL SCIENCES↗

Magnetic structure and resistivity minimum in GdCuAs 2

The electrical resistivity of GdCuAs 2 single crystals exhibits an anomalous Kondo-like resistivity minimum above the antiferromagnetic ordering temperature T N 1 approximate to 10.6 K, which is unusual for a highly localized 4f-moment (Gd 3+ ) system. Using x-ray resonant magnetic scattering, we determined the magnetic structure of GdCuAs 2 , where Gd moments are antiferromagnetically aligned along the crystallographic a axis and in the (+ + --) arrangement in the c direction and ferromagnetically arranged in the b direction. The antiferromagnetic order appears first at q = (δ, 0, 0.5) below 10 K, with an incommensurate modulation along the a axis and locks into a commensurate position at q = (1/3, 0, 0.5) below T N 2 approximate to 6 K. Our high-resolution x-ray diffraction measurements show a two-peak structure at Q = (2, 0, 6) above the resistivity minimum, suggesting a lower-symmetry crystal structure than the reported tetragonal structure, and the Q = (2, 0, 6) peak becomes a sharp one-peak structure below the resistivity minimum, implying a magnetoelastic coupling above T N . In conclusion, our findings suggest a complex interplay between the crystal structure and antiferromagnetic structure through a magnetoelastic coupling, associated with the anomalous resistivity minimum above T N 1 .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Correcting magnetic resonance k-space data for in-plane motion using an optical position tracking system

Purpose: Motion is a major confound of image quality in MRI. A method of retrospectively correcting the effects of rotations and translations on the acquired k-space data is presented. Methods: In two phantom experiments of well-controlled translation and rotation, two MRI-compatible infrared cameras recorded motion data that were used subsequently to correct the position and phase of recorded k-space samples. Motion data can be acquired with a temporal resolution of 60 Hz and spatial accuracy of 0.1 mm for translations and 0.2 deg. for rotations. Results: Significant improvements of image quality are demonstrated. Conclusions: The key advantages of the technique are that it is easy to implement, does not interfere with or complicate MR data acquisition, and is capable of correcting distortions within a single slice. Therefore, the technique has the potential to improve upon approaches that rely on the registration or realignment of successive imaging slices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

BrachyView: Proof-of-principle of a novel in-body gamma camera for low dose-rate prostate brachytherapy

Purpose: The conformity of the achieved dose distribution to the treatment plan strongly correlates with the accuracy of seed implantation in a prostate brachytherapy treatment procedure. Incorrect seed placement leads to both short and long term complications, including urethral and rectal toxicity. The authors present BrachyView, a novel concept of a fast intraoperative treatment planning system, to provide real-time seed placement information based on in-body gamma camera data. BrachyView combines the high spatial resolution of a pixellated silicon detector (Medipix2) with the volumetric information acquired by a transrectal ultrasound (TRUS). The two systems will be embedded in the same probe so as to provide anatomically correct seed positions for intraoperative planning and postimplant dosimetry. Dosimetric calculations are based on the TG-43 method using the real position of the seeds. The purpose of this paper is to demonstrate the feasibility of BrachyView using the Medipix2 pixel detector and a pinhole collimator to reconstruct the real-time 3D position of low dose-rate brachytherapy seeds in a phantom. Methods: BrachyView incorporates three Medipix2 detectors coupled to a multipinhole collimator. Three-dimensionally triangulated seed positions from multiple planar images are used to determine the seed placement in a PMMA prostate phantom in real time. MATLAB codes were used to test the reconstruction method and to optimize the device geometry. Results: The results presented in this paper show a 3D position reconstruction accuracy of the seed in the range of 0.5-3 mm for a 10-60 mm seed-to-detector distance interval (Z direction), respectively. The BrachyView system also demonstrates a spatial resolution of 0.25 mm in the XY plane for sources at 10 mm distance from Medipix2 detector plane, comparable to the theoretical value calculated for an equivalent gamma camera arrangement. The authors successfully demonstrated the capability of BrachyView for real-time imaging (using a 3 s data acquisition time) of different brachytherapy seed configurations (with an activity of 0.05 U) throughout a 60 Multiplication-Sign 60 Multiplication-Sign 60 mm{sup 3} Perspex prostate phantom. Conclusions: The newly developed miniature gamma camera component of BrachyView, with its high spatial resolution and real time capability, allows accurate 3D localization of seeds in a prostate phantom. Combination of the gamma camera with TRUS in a single probe will complete the BrachyView system.

60 APPLIED LIFE SCIENCES↗

Evaluation of an active magnetic resonance tracking system for interstitial brachytherapy

Purpose: In gynecologic cancers, magnetic resonance (MR) imaging is the modality of choice for visualizing tumors and their surroundings because of superior soft-tissue contrast. Real-time MR guidance of catheter placement in interstitial brachytherapy facilitates target coverage, and would be further improved by providing intraprocedural estimates of dosimetric coverage. A major obstacle to intraprocedural dosimetry is the time needed for catheter trajectory reconstruction. Herein the authors evaluate an active MR tracking (MRTR) system which provides rapid catheter tip localization and trajectory reconstruction. The authors assess the reliability and spatial accuracy of the MRTR system in comparison to standard catheter digitization using magnetic resonance imaging (MRI) and CT. Methods: The MRTR system includes a stylet with microcoils mounted on its shaft, which can be inserted into brachytherapy catheters and tracked by a dedicated MRTR sequence. Catheter tip localization errors of the MRTR system and their dependence on catheter locations and orientation inside the MR scanner were quantified with a water phantom. The distances between the tracked tip positions of the MRTR stylet and the predefined ground-truth tip positions were calculated for measurements performed at seven locations and with nine orientations. To evaluate catheter trajectory reconstruction, fifteen brachytherapy catheters were placed into a gel phantom with an embedded catheter fixation framework, with parallel or crossed paths. The MRTR stylet was then inserted sequentially into each catheter. During the removal of the MRTR stylet from within each catheter, a MRTR measurement was performed at 40 Hz to acquire the instantaneous stylet tip position, resulting in a series of three-dimensional (3D) positions along the catheter’s trajectory. A 3D polynomial curve was fit to the tracked positions for each catheter, and equally spaced dwell points were then generated along the curve. High-resolution 3D MRI of the phantom was performed followed by catheter digitization based on the catheter’s imaging artifacts. The catheter trajectory error was characterized in terms of the mean distance between corresponding dwell points in MRTR-generated catheter trajectory and MRI-based catheter digitization. The MRTR-based catheter trajectory reconstruction process was also performed on three gynecologic cancer patients, and then compared with catheter digitization based on MRI and CT. Results: The catheter tip localization error increased as the MRTR stylet moved further off-center and as the stylet’s orientation deviated from the main magnetic field direction. Fifteen catheters’ trajectories were reconstructed by MRTR. Compared with MRI-based digitization, the mean 3D error of MRTR-generated trajectories was 1.5 ± 0.5 mm with an in-plane error of 0.7 ± 0.2 mm and a tip error of 1.7 ± 0.5 mm. MRTR resolved ambiguity in catheter assignment due to crossed catheter paths, which is a common problem in image-based catheter digitization. In the patient studies, the MRTR-generated catheter trajectory was consistent with digitization based on both MRI and CT. Conclusions: The MRTR system provides accurate catheter tip localization and trajectory reconstruction in the MR environment. Relative to the image-based methods, it improves the speed, safety, and reliability of the catheter trajectory reconstruction in interstitial brachytherapy. MRTR may enable in-procedural dosimetric evaluation of implant target coverage.

60 APPLIED LIFE SCIENCES↗

Neutron Imaging of Advanced Transportation Technologies

Unlike X-rays, neutrons are very sensitive to light elements such as hydrogen (H) atoms and can penetrate through thick layers of metals (Figure 1a). These two properties suggest neutrons are well suited to probe engine parts such as diesel particulate filters, exhaust gas recirculation coolers, fuel injectors, oil in engines, oil residues in filters, batteries, advanced materials, etc. Neutron imaging is based on the interactions of a sample with a neutron beam. The interactions are dependent on sample thickness/density and elemental make-up and result in absorption and scattering of neutrons within the sample. A two-dimensional position-sensitive detector placed behind the sample can measure the transmitted neutron flux (Figure 1b). When combined with a high-precision (~1/100 of a degree) rotational stage, it is possible to perform computed tomography (CT) scans and thus generate 3-dimensional images of working fluids inside real devices. Samples can be analyzed at one position or a complete reconstruction can provide a cross-section of the entire sample at a resolution of the detector; the detector resolution is currently at ~50–80 microns (at the detector).

47 OTHER INSTRUMENTATION↗

In Situ Characterization of Hydrated Proteins in Water by SALVI and ToF-SIMS

We demonstrate in situ chemical imaging of protein biomolecules in the aqueous solution using System for Analysis at the Liquid Vacuum Interface (SALVI) and time-of-flight secondary ion mass spectrometry (ToF-SIMS). The fibronectin protein film was immobilized on the silicon nitride (SiN) membrane forming the SALVI detection area. During ToF-SIMS analysis, three modes of analysis were conducted including high spatial resolution mass spectra, two-dimensional (2D) imaging, and depth profiling. Mass spectra were acquired in both positive and negative modes. Deionized water was also analyzed as a reference sample. Our results show that fibronectin film in water has more distinct and stronger water cluster peaks compared to water alone. Characteristic peaks of amino acid fragments are also observable in the hydrated protein ToF-SIMS spectra. These results illustrate that protein molecule adsorption on a surface can be studied dynamically using SALVI and ToF-SIMS in the liquid environment.

chemical imaging↗

A 4 x 4 array module of position-sensitive virtual Frisch-grid CdZnTe detectors for gamma-ray imaging spectrometers

Arrays of position-sensitive virtual Frisch-grid CdZnTe (CZT) detectors offer an economical approach to making high efficiency and high energy resolution gamma cameras for spectroscopy and imaging of radioactive sources. There are many application areas for such instruments including gamma-rays astronomy, medical and industrial imaging, nonproliferation and nuclear safeguards. We present the test results from a 4x4 array module coupled to the front-end ASIC. The array houses 16 detectors made of 6x6x20 mm 3 CZT crystals. Each crystal is encapsulated inside an ultrathin polyester shell and furnished with four 5-mm-wide charge-sensing pads placed near the anode on each side of the detector. The pad’s signals are used to measure X-Y coordinates while the cathode signals give the interaction depths (Z coordinates). Combined together the signals provide 3D position information of the interaction points which can be used to correct the detector response non-uniformity. This allows developers to use standard grade (unselected) CZT crystals while retaining high spectroscopic performance comparable with that of the H3D pixelated detectors. The array’s design provides flexibility to replace individual detectors and extend their sizes, potentially increasing upwards of 4 cm in height. We started development of position-sensitive VFG detectors several years ago and today this technology has reached a high-maturity level and is ready to use in practical applications.

3D charge-loss correction↗

E3SM‐Arctic: Regionally Refined Coupled Model for Advanced Understanding of Arctic Systems Interactions

Earth system models are essential tools for climate projections, but coarse resolutions limit regional accuracy, especially in the Arctic. Regionally refined meshes (RRMs) enhance resolution in key areas while maintaining computational efficiency. This paper provides an overview of the United States (U.S.) Department of Energy's (DOE's) Energy Exascale Earth System Model version 2.1 with an Arctic RRM, hereafter referred to as E3SMv2.1-Arctic, for the atmosphere (25 km), land (25 km), and ocean/ice (10 km) components. We evaluate the atmospheric component and its interactions with land, ocean, and cryosphere by comparing the RRM (E3SM2.1-Arctic) historical simulations (1950–2014) with the uniform low-resolution (LR) counterpart, reanalysis products, and observational data sets. The RRM generally reduces biases in the LR model, improving simulations of Arctic large-scale mean fields, such as precipitation, atmospheric circulation, clouds, atmospheric river frequency, and sea ice thickness. However, it introduces a seasonally dependent surface air temperature bias, reducing the LR cold bias in summer but enhancing the LR warm bias in winter, which contributes to the underestimated winter sea ice area and volume. Radiative feedback analysis shows similar climate feedback strengths in both model configurations, with the RRM exhibiting a more positive surface albedo feedback and contributing to a stronger surface warming than LR. These findings underscore the importance of high-resolution modeling for advancing our understanding of Arctic climate changes and their broader global impacts, although some persistent biases appear to be independent of model resolution at 10–100 km scales.

Energy Exascale Earth System Model (E3SM)↗

The Impact of Multiple-Site Interactions on the Energy Resolution of a High-Pressure Xenon Gamma-Ray Spectrometer

High-pressure xenon (HPXe) ionization chambers have generated interest as a radiation detection medium for purposes requiring good energy resolution, high detection efficiency, and uniform response over a broad temperature range, such as homeland security and well logging applications. These chambers generally exhibit a substantial degradation of the measured energy resolution relative to theoretical limits. This investigation studies the impact of the number of interaction sites in an event sequence on the measured energy resolution using a benchmarked simulation package. The prominence of single and multiple-site interactions is investigated in addition to the photopeak broadening due to each event class. A radial position-sensing technique developed for coplanar-anode HPXe chambers is shown to have benefit for only single-site events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗