Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PROBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Numerical matching of the sheath and presheath solutions for a spherical probe in radial-motion theory

The theory of positive-ion collection by a probe immersed in a low-pressure plasma was reviewed and extended by Allen, Boyd, and Reynolds [Proc. Phys. Soc. 70, 297 (1957)]. For a given value of the ion current, the boundary values of the matched “nonneutral” or “sheath” solution V{sup ~}{sub nn}{sup (m)}(r; r{sub m}) were obtained from the “quasineutral” or “presheath” solution V{sup ~}{sub qn}(r) by choosing the small potential and electric-field values corresponding to some large “matching radius” r{sub m}. Here, a straightforward but efficient numerical method is presented for systematically determining an optimal value of the matching radius at which the presheath and sheath solutions are joined to yield the “matched” potential profile. Some suitable initial matching radius r{sub m1} is chosen and the related potential and electric-field values of the quasineutral solution are calculated. Using these as boundary conditions, Poisson's equation is integrated to yield the matched nonneutral solution including the corresponding potential at the probe surface. This procedure is repeated for increasing values r{sub m2}, r{sub m3},…. until the resulting potential at the probe surface becomes practically constant. The corresponding value of r{sub m} is taken as the “optimal” matching radius r{sub mo} at which the presheath and sheath solutions are ultimately joined to yield the “optimal” matched potential profile in the entire plasma-probe transition region. It is also shown that the Bohm criterion is inapplicable in the present problem.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-bandwidth, high-sampling-rate, low-noise, two-probe transient photovoltage measuring system

In this article, we present a two-probe configuration for measuring transient photovoltage (TPV) signals from photo-electronic semiconductor devices. Unlike in a conventional one-probe system, the two electrodes of the devices under test in this study are both monitored in our new measuring system, giving rise to a significantly enhanced signal-to-noise ratio. Tentative experimental data ob tained from N, N′-Di(1-naphthyl)-N,N′-diphenyl-(1,1′-biphenyl)-4,4′-diamine-based organic semiconductor devices show that the bandwidth and the sampling rate of the system reach 1.5 GHz and 50 GS/s, respectively, without degradation of the noise level. In addition, the study of TPV signals on each individual electrode is allowed. The TPV values measured by the two individual probes are not identically equal to half of the differential TPV and will not cancel each other out as expected. This abnormal phenomenon is due to the photoelectric response of the photo-electronic material. This novel two-probe TPV measuring technique and abnormal TPV behavior might be useful for studying more dynamic processes in photo-electronic semiconductors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity enhancement of surface thermal lens technique with a short-wavelength probe beam: Experiment

Surface thermal lens is a highly sensitive photothermal technique to measure low absorption losses of various solid materials. In such applications, the sensitivity of surface thermal lens is a key parameter for measuring extremely low absorption. In this paper, we experimentally investigated the influence of probe beam wavelength on the sensitivity of surface thermal lens for measuring the low absorptance of optical laser components. Three probe lasers with wavelength 375 nm, 633 nm, and 1570 nm were used, respectively, to detect the surface thermal lens amplitude of a highly reflective coating sample excited by a cw modulated Gaussian beam at 1064 nm. The experimental results showed that the maximum amplitude of surface thermal lens signal obtained at corresponding optimized detection distance was inversely proportional to the wavelength of the probe beam, as predicted by previous theoretical model. The sensitivity of surface thermal lens could, therefore, be improved by detecting surface thermal lens signal with a short-wavelength probe beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental validation of an 8 element EMAT phased array probe for longitudinal wave generation

Sodium cooled Fast Reactors (SFR) use liquid sodium as a coolant. Liquid sodium being opaque, optical techniques cannot be applied to reactor vessel inspection. This makes it necessary to develop alternative ways of assessing the state of the structures immersed in the medium. Ultrasonic pressure waves are well suited for inspection tasks in this environment, especially using pulsed electromagnetic acoustic transducers (EMAT) that generate the ultrasound directly in the liquid sodium. The work carried out at CEA LIST is aimed at developing phased array EMAT probes conditioned for reactor use. The present work focuses on the experimental validation of a newly manufactured 8 element probe which was designed for beam forming imaging in a liquid sodium environment. A parametric study is carried out to determine the optimal setup of the magnetic assembly used in this probe. First laboratory tests on an aluminium block show that the probe has the required beam steering capabilities.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The time resolved measurement of ultrashort terahertz-band electric fields without an ultrashort probe

The time-resolved detection of ultrashort pulsed THz-band electric field temporal profiles without an ultrashort laser probe is demonstrated. A non-linear interaction between a narrow-bandwidth optical probe and the THz pulse transposes the THz spectral intensity and phase information to the optical region, thereby generating an optical pulse whose temporal electric field envelope replicates the temporal profile of the real THz electric field. This optical envelope is characterised via an autocorrelation based FROG (frequency resolved optical gating) measurement, hence revealing the THz temporal profile. The combination of a narrow-bandwidth, long duration, optical probe, and self-referenced FROG makes the technique inherently immune to timing jitter between the optical probe and THz pulse and may find particular application where the THz field is not initially generated via ultrashort laser methods, such as the measurement of longitudinal electron bunch profiles in particle accelerators.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A model of plasma current through a hole of Rogowski probe including sheath effects

In TST-2 Ohmic discharges, local current is measured using a Rogowski probe by changing the angle between the local magnetic field and the direction of the hole of the Rogowski probe. The angular dependence shows a peak when the direction of the hole is almost parallel to the local magnetic field. The obtained width of the peak was broader than that of the theoretical curve expected from the probe geometry. In order to explain this disagreement, we consider the effect of sheath in the vicinity of the Rogowski probe. A sheath model was constructed and electron orbits were numerically calculated. From the calculation, it was found that the electron orbit is affected by E × B drift due to the sheath electric field. Such orbit causes the broadening of the peak in the angular dependence and the dependence agrees with the experimental results. The dependence of the broadening on various plasma parameters was studied numerically and explained qualitatively by a simplified analytical model.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Upgrade of Langmuir probe diagnostic in ITER-like tungsten mono-block divertor on experimental advanced superconducting tokamak

In order to withstand rapid increase in particle and power impact onto the divertor and demonstrate the feasibility of the ITER design under long pulse operation, the upper divertor of the EAST tokamak has been upgraded to actively water-cooled, ITER-like tungsten mono-block structure since the 2014 campaign, which is the first attempt for ITER on the tokamak devices. Therefore, a new divertor Langmuir probe diagnostic system (DivLP) was designed and successfully upgraded on the tungsten divertor to obtain the plasma parameters in the divertor region such as electron temperature, electron density, particle and heat fluxes. More specifically, two identical triple probe arrays have been installed at two ports of different toroidal positions (112.5-deg separated toroidally), which can provide fundamental data to study the toroidal asymmetry of divertor power deposition and related 3-dimension (3D) physics, as induced by resonant magnetic perturbations, lower hybrid wave, and so on. The shape of graphite tip and fixed structure of the probe are designed according to the structure of the upper tungsten divertor. The ceramic support, small graphite tip, and proper connector installed make it possible to be successfully installed in the very narrow interval between the cassette body and tungsten mono-block, i.e., 13.5 mm. It was demonstrated during the 2014 and 2015 commissioning campaigns that the newly upgraded divertor Langmuir probe diagnostic system is successful. Representative experimental data are given and discussed for the DivLP measurements, then proving its availability and reliability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integration of conductivity probe with optical and x-ray imaging systems for local air–water two-phase flow measurement

Various techniques have been developed in the past to measure different parameters in two-phase flow. Among them, the multi-sensor conductivity probe is one of the most commonly used techniques because of its good overall performance. Recently, more advanced techniques such as high speed optical imaging and fast X-ray densitometry become mature and easily accessible. The main objective of this work is to compare and integrate these different techniques, to achieve a more accurate and complete measurement of two-phase flow. In this study, a double-sensor conductivity probe is used to measure the local time-averaged parameters along the radial direction of a 2.54 cm ID round pipe. An X-ray densitometry system is used to measure the chordal averaged void fraction and gas velocity. A high speed camera system is employed to provide the visualization of the two-phase flow structure and obtain the line-averaged gas velocity. The unique advantages and main uncertainties of these three techniques are analyzed by considering their measuring principles and possible issues in practical measurements. From this, a method is developed to integrate the data obtained by the optical and X-ray systems into the probe signal processing. Finally, a better accuracy could be achieved using this method for various local two-phase flow parameters including void fraction, bubble velocity and superficial gas velocity, compared to the original probe measurements.

42 ENGINEERING↗

Nondestructive cavity QED probe of Bloch oscillations in a gas of ultracold atoms

We describe a scheme for probing a gas of ultracold atoms trapped in an optical lattice and moving in the presence of an external potential. The probe is nondestructive and uses the existing lattice fields as the measurement device. Two counterpropagating cavity fields simultaneously set up a conservative lattice potential and a weak quantum probe of the atomic motion. Balanced heterodyne detection of the probe field at the cavity output along with integration in time and across the atomic cloud yield information about the atomic dynamics in a single run. The scheme is applied to a measurement of the Bloch oscillation frequency for atoms moving in the presence of the local gravitational potential. Signal-to-noise ratios are estimated to be as high as 10{sup 4}.

74 ATOMIC AND MOLECULAR PHYSICS↗

Diffraction barrier breakthrough in coherent anti-Stokes Raman scattering microscopy by additional probe-beam-induced phonon depletion

We provide an approach to significantly break the diffraction limit in coherent anti-Stokes Raman scattering (CARS) microscopy via an additional probe-beam-induced photon depletion (APIPD). The additional probe beam, whose profile is doughnut shaped and whose wavelength is different from the Gaussian probe beam, depletes the phonons to yield an unwanted anti-Stokes signal within a certain bandwidth at the rim of the diffraction-limited spot. When the Gaussian probe beam that follows immediately arrives, no anti-Stokes signal is generated in this region, resembling stimulated emission depletion (STED) microscopy, and the spot-generating useful anti-Stokes signals by this beam are substantially suppressed to a much smaller dimension. Scanning the spot renders three-dimensional, label-free, and chemically selective CARS images with subdiffraction resolution. Also, resolution-enhanced images of the molecule, specified by its broadband even-total CARS spectral signals not only by one anti-Stokes signal for its special chemical bond, can be obtained by employing a supercontinuum source.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Phase control of probe response in a Doppler-broadened N-type four-level system

In this paper, we investigate theoretically the effect of the relative phase ({phi}) between the probe and driving fields on gain (absorption) and dispersion of the probe field in a Doppler-broadened N-type four-level system with spontaneously generated coherence from different respects. It is shown that gain (absorption) and dispersion are very sensitive to variations in the relative phase, and changing the Doppler width also has an obvious effect on the phase-dependent gain (absorption) and dispersion. When the probe and driving fields have the same propagation directions (copropagating), for the same Doppler width, the dispersion curve with {phi}={alpha} is the same as the gain (absorption) curve with {phi}={alpha}+{pi}/2; however, when the probe and driving fields have opposite propagation directions (counterpropagating), the dispersion curve and gain (absorption) curve are different and the difference becomes more considerable with an increase in Doppler width. In the co- and counterpropagating cases, gain (absorption) and dispersion always vary periodically with varying {phi}, and the period is 2{pi}. By adjusting the value of {phi}, the largest gain (absorption) and dispersion can be obtained, and a large index of refraction without absorption can be realized. Generally speaking, gain decreases with an increase in Doppler width, but by adjusting value of {phi}, at some special values of Doppler width, a larger gain than that without Doppler broadening can be obtained. Our study also shows that gain in the copropagating case is much larger than that in the counterpropagating case.

74 ATOMIC AND MOLECULAR PHYSICS↗

The Interaction of an 180o Ferroelectric Domain Wall with a Biased Scanning Probe Microscopy Tip: Effective Wall Geometry and Thermodynamics in Ginzburg-Landau-Devonshire Theory

The interaction of ferroelectric 180o-domain wall with a strongly inhomogeneous electric field of biased Scanning Probe Microscope tip is analyzed within continuous Landau-Ginzburg-Devonshire theory. Equilibrium shape of the initially flat domain wall boundary bends, attracts or repulses from the probe apex, depending on the sign and value of the applied bias. For large tip-wall separations, the probe-induced domain nucleation is possible. The approximate analytical expressions for the polarization distribution are derived using direct variational method. The expressions provide insight how the equilibrium polarization distribution depends on the wall finite-width, correlation and depolarization effects, electrostatic potential distribution of the probe and ferroelectric material parameters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnon sidebands and spin-charge coupling in bismuth ferrite probed by nonlinear optical spectroscopy.

The interplay between spin waves (magnons) and electronic structure in materials leads to the creation of additional bands associated with electronic energy levels which are called magnon sidebands. The large difference in the energy scales between magnons (meV) and electronic levels (eV) makes this direct interaction weak and hence makes magnon sidebands difficult to probe. Linear light absorption and scattering techniques at low temperatures are traditionally used to probe these sidebands. Here we show that optical second-harmonic generation, as the lowest-order nonlinear process, can successfully probe the magnon sidebands at room temperature and up to 723 K in bismuth ferrite, associated with large wave vector multimagnon excitations which linear absorption studies are able to resolve only under high magnetic fields and low temperatures. Polarized light studies and temperature dependence of these sidebands reveal a spin-charge coupling interaction of the type P{sub s}L{sup 2} between the spontaneous polarization (P{sub s}) and antiferromagnetic order parameter, L in bismuth ferrite, that persists with short-range correlation well into the paramagnetic phase up to high temperatures. These observations suggest a broader opportunity to probe the collective spin-charge-lattice interactions in a wide range of material systems at high temperatures and electronic energy scales using nonlinear optics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Investigations of laser plasmas dynamics by means of real and virtual Langmuir probes

In this paper we propose a novel technique for LPP-Laser Produced Plasmas investigation, combining high time resolved measurements using compact Langmuir Probes with the output of a theoretical model called HYBLAS developed on purpose, which is able to simulate the charged particles collected by a so-called virtual probe. It will be shown that with an appropriate experimental set-up and with the use of a Matlab software able to accurately analyze the experimental I-V curves, laser plasmas can be investigated properly even if the probe is placed very close to the target surface. This permits not only to study the plume expansion with a high temporal resolution, but also to estimate correctly the self-generated coulomb electric field inside the plume and to detect the inner structure of the the first upcoming expanding plasma. HYBLAS is able to predict and describe the plume expansion at relatively low power densities and is a powerful method to compare directly the experimental current signals with the numerical results if the initial conditions are settled properly. A direct comparison of the theoretical data with the experimental ones realized on different metal targets shows that our method is able to predict properly the overall plasma expansion in the nanosecond laser pulse duration regime. The virtual probe method was moreover tested by comparing the numerical results with another numerical code called MULTI, which simulate the expansion by combining the hydrodynamics equations to a multigroup method in order to include the radiation transport. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of atmospheric pressure microplasma jet with Langmuir probes

A radio frequency argon microplasma jet at atmospheric-pressure is characterized using Langmuir probes. While optical methods are the typical diagnostic for these small scale plasmas, the simplicity and low cost of Langmuir probes makes them an attractive option. The plasma density and electron temperature are measured using existing high-pressure Langmuir probe theories developed for flames and arcs. The density and temperature vary from 1 × 10{sup 16} to 1 × 10{sup 19} m{sup −3} and 2.3 to 4.4 eV, respectively, depending on the operating condition. The density decreases while the electron temperature increases with axial distance from the jet exit. The applicability of the probe theories as well as the effect of collisionality and jet mixing is discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

PICO - the probe of inflation and cosmic origins

Downloading of the abstract is permitted for personal use only. The Probe of Inflation and Cosmic Origins (PICO) is a NASA-funded study of a Probe-class mission concept. The toplevel science objectives are to probe the physics of the Big Bang by measuring or constraining the energy scale of inflation, probe fundamental physics by measuring the number of light particles in the Universe and the sum of neutrino masses, to measure the reionization history of the Universe, and to understand the mechanisms driving the cosmic star formation history, and the physics of the galactic magnetic field. PICO would have multiple frequency bands between 21 and 799 GHz, and would survey the entire sky, producing maps of the polarization of the cosmic microwave background radiation, of galactic dust, of synchrotron radiation, and of various populations of point sources. Several instrument configurations, optical systems, cooling architectures, and detector and readout technologies have been and continue to be considered in the development of the mission concept. We will present a snapshot of the baseline mission concept currently under development.

47 OTHER INSTRUMENTATION↗

The Probe Length Effect on the Cantilever of an Atomic Force Microscope in Measuring the Mechanical Properties of Living Neurons

Living sensory neurons were studied by atomic force microscopy in the PeakForce QNM mode under near-physiological conditions. The dependence of the measured apparent Young modulus of cells on the ratio of the probe height to the beam length on a used cantilever was revealed. A qualitative explanation based on the analysis of beam strains in two limit cases, in which the probe slides over a studied object and the probe sticks to the latter, was given to the obtained result. It was proposed to classify native cells by the character of their interaction with the probe (sliding or sticking).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Test plan and procedure for the examination of tank 241-AY-101 multi-probe corrosion monitoring system

This test plan describes the methods to be used in the forensic examination of the Multi-probe Corrosion Monitoring System (MPCMS) installed in the double-shell tank 241-AY-101 (AY-101). The probe was designed by Applied Research and Engineering Sciences (ARES) Corporation. The probe contains four sections, each of which can be removed from the tank independently (H-14-107634, AY-101 MPCMS Removable Probe Assembly) and one fixed center assembly. Each removable section contains three types of passive corrosion coupons: bar coupons, round coupons, and stressed C-rings (H-14-l07635, AY-101 MPCMS Details). Photographs and weights of each coupon were recorded and reported on drawing H-14-107634 and in RPP-RPT-40629, 241-AY-101 MPCMS C-Ring Coupon Photographs. The coupons will be the subject of the forensic analyses. The purpose of this examination will be to document the nature and extent of corrosion of the 29 coupons. This documentation will consist of photographs and photomicrographs of the C-rings and round coupons, as well as the weights of the bar and round coupons during corrosion removal. The total weight loss of the cleaned coupons will be used in conjunction with the surface area of each to calculate corrosion rates in mils per year. The bar coupons were presumably placed to investigate the liquid-air-interface. An analysis of the waste level heights in the waste tank will be investigated as part of this examination.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗