Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLASMA PROBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Waves In Space Plasmas (WISP): A space plasma lab active experiment

The Waves in Space Plasmas (WISP) series of Spacelab Space Plasma Labs devoted to active experimentation, are introduced. Space Plasma Lab-1 is keyed to active probing of the ionosphere and magnetosphere using controlled wave injections by the WISP VLF and HF transmitters, supported by a free-flying plasma diagnostics package instrumented with wave receivers and particle probe diagnostics, designed to measure radiation and propagation of plasma waves, precipitated particle fluxes due to wave/particle interactions, and similar phenomena resulting from wave injectons. The VLF transmitter delivers up to 1 kW of RF power into the antenna terminals over the range from 0.3 to 30 kHz. The HF transmitter delivers up to 500 W to the antenna over the range from 1 to 30 MHz. A dipole antenna commandable to any extension up to 300 m tip-to-tip is available.

Fredricks, R. W.↗

Development of a WDM platform for charged-particle stopping experiments

A platform has been developed for generating large and relatively quiescent plasmas in the warm-dense matter (WDM) regime on the OMEGA laser facility. A cylindrical geometry is used to allow charged-particle probing along the axis. The plasma heating is radiative by L-shell emission generated on the outside of the cylinder. The cylinder drive is characterized with x-ray diagnostics. Possibilities for direct characterization of the plasma temperature are discussed. Lastly, the unimportance of electromagnetic fields around the target is demonstrated with proton radiography. We expect this platform to be used extensively in future experiments studying charged-particle stopping in this regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion Channel Laser Based on Direct Laser Acceleration of a Shaped Beam Driver (Final Technical Report)

The main focus of our research was to understand the synergies between an electron bunch and a laser pulse when the two co-propagate through the plasma. We have clearly demonstrated using theoretical and computational modeling that the propagation distance of both the bunch and the laser pulse could be extended. The ability of the combined bunch/pulse system to extend the propagation distance and the size of the plasma bubble enables highly-efficient sources of relativistic electrons. As pointed out by the Plasma Decadal Study, such electron sources can be used for generating extremely bright x-rays for a variety of applications can serve as probes and diagnostics for other plasma experiments: high energy density (HED) sciences, inertial confinement fusion (ICF), and potentially Fusion Materials and Technology (FM&T). Development of advanced diagnostics of plasma-based accelerators is yet another key area identified by recent reports. Even broader security and medical applications of compact accelerator-based radiation sources, such as very high energy electron (VHEE) sources for FLASH radiobiology, have been identified by a recent multi-agency panel. A number of key technical issues were considered and successfully resolved during the course of the grant. Those include: beam loading effect of both the driver and witness bunches on the wake, laser channeling by the bunch, and the direct laser acceleration (DLA) of the driver bunch by the laser pulse. To demonstrate clear synergy, we were able to ascertain that the total energy gain of a witness bunch in the wake of the combined bunch/laser complex is large than the sum of the energy gains in the wake of the laser pulse alone, and the driver bunch alone. We have also demonstrated that not only the energy gain is improved, but the energy spread is not sacrificed. To carry out these simulations, we have to develop a range of in-house computational tools, including a fully-3D code WAND-PIC.

43 PARTICLE ACCELERATORS↗

Effect of argon and hydrogen on deposition of silicon from tetrochlrosilane in cold plasmas

The roles of Ar and H2 on the decomposition of SiCl4 in cold plasma were investigated by Langmuir probes and mass spectrometry. Decomposition of the reactant by Ar only has been found to be very slow. In presence of H2 in the plasma SiCl4 is decomposed by fast radical-molecule reactions which are further enhanced by Ar due to additional ion-molecule reactions in which more H radicals are produced. A model for the plasma-surface interactions during deposition of mu-Si in the Ar + H2 + SiCl4 system is presented.

Manory, R. R.↗

Oscillating plasma bubbles. III. Internal electron sources and sinks

An internal electron source has been used to neutralize ions injected from an ambient plasma into a spherical grid. The resultant plasma is termed a plasma 'bubble.' When the electron supply from the filament is reduced, the sheath inside the bubble becomes unstable. The plasma potential of the bubble oscillates near but below the ion plasma frequency. Different modes of oscillations have been observed as well as a subharmonic and multiple harmonics. The frequency increases with ion density and decreases with electron density. The peak amplitude occurs for an optimum current and the instability is quenched at large electron densities. The frequency also increases if Langmuir probes inside the bubble draw electrons. Allowing electrons from the ambient plasma to enter, the bubble changes the frequency dependence on grid voltage. It is concluded that the net space charge density in the sheath determines the oscillation frequency. It is suggested that the sheath instability is caused by ion inertia in an oscillating sheath electric field which is created by ion bunching.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetically insulated baffled probe for real-time monitoring of equilibrium and fluctuating values of space potentials, electron and ion temperatures, and densities

By restricting the electron-collection area of a cold Langmuir probe compared to the ion-collection area, the probe floating potential can become equal to the space potential, and thus conveniently monitored, rather than to a value shifted from the space potential by an electron-temperature-dependent offset, i.e., the case with an equal-collection-area probe. This design goal is achieved by combining an ambient magnetic field in the plasma with baffles, or shields, on the probe, resulting in species-selective magnetic insulation of the probe collection area. This permits the elimination of electron current to the probe by further adjustment of magnetic insulation which results in an ion-temperature-dependent offset when the probe is electrically floating. Subtracting the floating potential of two magnetically insulated baffled probes, each with a different degree of magnetic insulation, enables the electron or ion temperature to be measured in real time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Active Experiments in Space: The Future

Planned active space experiments and ideas for future active space experiments are reviewed. Three active experiments being readied are DSX (Demonstration and Space eXperiments), SMART (Space Measurement of Rocket-released Turbulence), and BeamPIE (Beam Plasma Interaction Experiment). Ideas for future experiments include relativistic-electron-beam experiments for magnetic-field-line tracing, relativistic-electron-beam experiments to probe the middle atmosphere, plasma-wave launching using superparamagnetic-nanoparticle amplification of magnetic fields, the heavy-ion mass loading of collisionless magnetic-field-line reconnection, the use of electrostatically charged tethers to pitch-angle scatter radiation-belt particles, cold plasma releases to modify magnetospheric plasma physics, and neutral-gas releases to enhance neutral-particle imaging of the magnetosphere. Technologies that are being developed to enable future space active experiments are reviewed: this includes the development of compact relativistic accelerators, superparamagnetic particle amplified antennae, CubeSats, and a new understanding of how to control dynamic spacecraft charging. New capabilities to use laboratory facilities to design space active experiments as well as new computer-simulation capabilities to design and understand space active experiments are reviewed.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of cylindrical Langmuir probe using experiment and different theories

Cylindrical probe data have been analyzed using different theories in order to determine some plasma parameters (electron temperature and electron and ion densities). Langmuir probe data are obtained in a cylindrical DC glow discharge in the positive column plasma at argon gas pressures varied from 0.5 to 6 Torr and at constant discharge current equal to 10 mA. The electron density has calculated from the electron current at the space potential and from Orbital Motion Limited (OML) collisionless theory. Ion density has obtained from the OML analysis of the ion saturation currents. In addition, the electron temperature has measured by three different methods using probe and electrons currents. The electron temperature T{sub e}, plasma density n{sub e}, and space potential V{sub s}, have been obtained from the measured single cylindrical probe I-V characteristic curves. The radial distribution of the electron temperature and plasma density along the glow discharge are measured and discussed. Using the collisionless theories by Langmuir cylindrical probe and up to several Torr argon gas pressures the differences between the values of electron temperature and electron and ion densities stay within reasonable error limits.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Oscillating plasma bubbles. I. Basic properties and instabilities

Plasma bubbles are created in an ambient discharge plasma. A bubble is a plasma volume of typically spherical shape, which is separated from the ambient plasma by a negatively biased grid of high transparency. Ions and electrons from the ambient plasma flow into the bubble volume. In steady state the flow of particles and currents is divergence-free, which is established by the plasma potential inside the bubble. The grid has two sheaths, one facing the ambient plasma, the other the bubble plasma. The inner sheath is observed to become unstable, causing the plasma potential in the bubble to oscillate. The instability arises from an excess of ions and a deficiency of electrons. Its frequency is in the range of the ion plasma frequency but depends on all parameters which influence the charge density in the sheath. When the grid voltage is very negative, electrons cannot enter the outer sheath, and the inner sheath becomes a virtual anode which reflects ions such that the bubble interior is empty. When an electron source is placed into the bubble it can neutralize the ions and the bubble refills. Without plasma sources or sinks the bubble plasma is extremely sensitive to perturbations by probes. Modified current-voltage characteristics of Langmuir and emissive probes are demonstrated. A sequence of papers first describes the basic steady-state properties, then the time evolution of bubbles, the effects of electron sources in bubbles, and the role of the grid and bubble geometry. The physics of plasma bubbles is important to several fields of basic plasma physics such as sheaths, sheath instabilities, diagnostic probes, electrostatic confinement, and current and space charge neutralization of beams.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In situ Raman monitoring of He{sup 2+} irradiation induced damage in a UO{sub 2} ceramic

The in situ Raman probing of a UO{sub 2} ceramic in [Ar/H{sub 2}, 95/5] gas atmosphere followed by exposure to He{sup 2+} ionic irradiation coming from a cyclotron accelerator was implemented. It was observed that the growth of Raman defect bands exhibits a unique kinetic nicely modelized by a simple direct impact model, and with an annealing rate constant of 5.6 × 10{sup −4} ± 4 × 10{sup −5} s{sup −1} for an ionic flow of 50 nA and an ions-beam induced sample heating of 170 ± 10 °C. Also, it was observed that the Ar plasma induced by the ions-beam is a sensitive probe of the presence of the ions-beam.

36 MATERIALS SCIENCE↗

Studies of RF sheaths and diagnostics on IShTAR

IShTAR (Ion cyclotron Sheath Test ARrangement) is a linear magnetised plasma test facility for RF sheaths studies at the Max-Planck-Institut für Plasmaphysik in Garching. In contrast to a tokamak, a test stand provides more liberty to impose the parameters and gives better access for the instrumentation and antennas. The project will support the development of diagnostic methods for characterising RF sheaths and validate and improve theoretical predictions. The cylindrical vacuum vessel has a diameter of 1 m and is 1.1 m long. The plasma is created by an external cylindrical plasma source equipped with a helical antenna that has been designed to excite the m=1 helicon mode. In inductive mode, plasma densities and electron temperatures have been characterised with a planar Langmuir probe as a function of gas pressure and input RF power. A 2D array of RF compensated Langmuir probes and a spectrometer are planned. A single strap RF antenna has been designed; the plasma-facing surface is aligned to the cylindrical plasma to ease the modelling. The probes will allow direct measurements of plasma density profiles in front of the RF antenna, and thus a detailed study of the density modifications induced by RF sheaths, which influences the coupling. The RF antenna frequency has been chosen to study different plasma wave interactions: the accessible plasma density range includes an evanescent and propagative behaviour of slow or fast waves, and allows the study of the effect of the lower hybrid resonance layer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TIA: A forward model and analyzer for Talbot interferometry experiments of dense plasmas

Interferometry is one of the most sensitive and successful diagnostic methods for plasmas. However, owing to the design of most common interferometric systems, the wavelengths of operation and, therefore, the range of densities and temperatures that can be probed are severely limited. Talbot–Lau interferometry offers the possibility of extending interferometry measurements to x-ray wavelengths by means of the Talbot effect. While there have been several proof-of-concept experiments showing the efficacy of this method, it is only recently that experiments to probe High Energy Density (HED) plasmas using Talbot–Lau interferometry are starting to take place. To improve these experimental designs, we present here the Talbot-Interferometry Analyzer (TIA) tool, a forward model for generating and postprocessing synthetic x-ray interferometry images from a Talbot–Lau interferometer. Although TIA can work with any two-dimensional hydrodynamic code to study plasma conditions as close to reality as possible, this software has been designed to work by default with output files from the hydrodynamic code FLASH, making the tool user-friendly and accessible to the general plasma physics community. Here, the model has been built into a standalone app, which can be installed by anyone with access to the MATLAB runtime installer and is available upon request to the authors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Standard Practices for Usage of Inductive Magnetic Field Probes with Application to Electric Propulsion Testing

Inductive magnetic field probes (also known as B-dot probes and sometimes as B-probes or magnetic probes) are useful for performing measurements in electric space thrusters and various plasma accelerator applications where a time-varying magnetic field is present. Magnetic field probes have proven to be a mainstay in diagnosing plasma thrusters where changes occur rapidly with respect to time, providing the means to measure the magnetic fields produced by time-varying currents and even an indirect measure of the plasma current density through the application of Ampère's law. Examples of applications where this measurement technique has been employed include pulsed plasma thrusters and quasi-steady magnetoplasmadynamic thrusters. The Electric Propulsion Technical Committee (EPTC) of the American Institute of Aeronautics and Astronautics (AIAA) was asked to assemble a Committee on Standards (CoS) for Electric Propulsion Testing. The assembled CoS was tasked with developing Standards and Recommended Practices for various diagnostic techniques used in the evaluation of plasma thrusters. These include measurements that can yield either global information related to a thruster and its performance or detailed, local data related to the specific physical processes occurring in the plasma. This paper presents a summary of the standard, describing the preferred methods for fabrication, calibration, and usage of inductive magnetic field probes for use in diagnosing plasma thrusters. Inductive magnetic field probes (also called B-dot probes throughout this document) are commonly used in electric propulsion (EP) research and testing to measure unsteady magnetic fields produced by time-varying currents. The B-dot probe is relatively simple in construction, and requires minimal cost, making it a low-cost technique that is readily accessible to most researchers. While relatively simple, the design of a B-dot probe is not trivial and there are many opportunities for errors in probe construction, calibration, and usage, and in the post-processing of data that is produced by the probe. There are typically several ways in which each of these steps can be approached, and different applications may require more or less vigorous attention to various issues.

Polzin, Kurt A.↗

Vacancy-type defects in In{sub x}Ga{sub 1-x}N alloys probed using a monoenergetic positron beam

Native defects in In{sub x}Ga{sub 1-x}N grown by plasma-assisted molecular beam epitaxy were probed by a monoenergetic positron beam. Doppler broadening spectra of the annihilation radiation were measured, and these were compared with results obtained using first-principles calculation. The defect concentration increased with increasing In composition x and reached the maximum at x = 0.44{approx}0.56. A clear correlation between the line-width of photoluminescence and the defect concentration was obtained. The major defect species detected by positron annihilation was identified as cation vacancies coupled with multiple nitrogen vacancies (V{sub N}s), and their introduction mechanism is discussed in terms of the strain energy due to bond-length/angle distortions and the suppression of the V{sub N} formation energy by neighboring In atoms.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Investigation of the eddy current effect on the high frequency response of the Mirnov probe on J-TEXT

Major plasma disruption is one of the most critical issues to be solved for tokamak fusion reactors. Experiments to prevent mode locking and subsequent disruptions have been carried out on the J-TEXT tokamak using rotating resonant magnetic perturbations (RMPs). The tearing modes, which are locked and lead to disruptions without the application of RMPs, can be accelerated by rotating RMPs to the RMP frequency. As a result, mode locking and subsequent disruptions are delayed or prevented. The effects of RMP amplitude and frequency on disruption prevention have been investigated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Density and temperature distributions in the plasma expanding from an exploded wire in vacuum

The plasma expansion from an exploded wire with characteristic times of energy deposition in the wire of tens of microseconds was studied. The probe method was used to measure the plasma temperature and plasma density distributions. Tungsten wires 25, 50, 75, and 125 {mu}m in diameter and a copper wire 100 {mu}m in diameter were used. The waveforms of discharge voltage U{sub d}, discharge current I{sub d}, and floating potential showed that U{sub d} was close to a constant, while I{sub d} decreased, indicating that the wire resistance increased until plasma appeared. Immediately after the appearance of plasma, I{sub d} was observed to peak, while the voltage decreased stepwise from {approx}110 to about 70 V. A relatively high electron temperature (about 12 eV) was observed in the expanding plasma even at r=2 cm from the wire axis. The plasma density was a maximum of 2x10{sup 13} cm{sup -3} at r=2 cm, and it decreased with increasing r. For r<2 cm, unusual electrical parameters were observed, indicating the probe activity and a significantly increased plasma density in the region close to the wire core.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and use of an Elsässer probe for analysis of Alfvén wave fields according to wave direction

We have designed an electric and magnetic field probe which simultaneously measure both quantities in the directions perpendicular to the background magnetic field for application to Alfvén wave experiments in the Large Plasma Device at UCLA. This new probe allows for the projection of measuredwave fields onto generalized Elsässer variables. Experiments were conducted in a singly ionized He plasma at 1850 G in which propagation of Alfvén waves was observed using this new probe. We demonstrate that a clear separation of transmitted and reflected signals and determination of Poynting flux and Elsässer variables can be achieved.

Drake, D. J.↗

A hybrid electron cyclotron resonance metal ion source with integrated sputter magnetron for the production of an intense Al{sup +} ion beam

A metal ion source prototype has been developed: a combination of magnetron sputter technology with 2.45 GHz electron cyclotron resonance (ECR) ion source technology—a so called magnetron ECR ion source (MECRIS). An integrated ring-shaped sputter magnetron with an Al target is acting as a powerful metal atom supply in order to produce an intense current of singly charged metal ions. Preliminary experiments show that an Al{sup +} ion current with a density of 167 μA/cm{sup 2} is extracted from the source at an acceleration voltage of 27 kV. Spatially resolved double Langmuir probe measurements and optical emission spectroscopy were used to study the plasma states of the ion source: sputter magnetron, ECR, and MECRIS plasma. Electron density and temperature as well as Al atom density were determined as a function of microwave and sputter magnetron power. The effect of ECR heating is strongly pronounced in the center of the source. There the electron density is increased by one order of magnitude from 6 × 10{sup 9} cm{sup −3} to 6 × 10{sup 10} cm{sup −3} and the electron temperature is enhanced from about 5 eV to 12 eV, when the ECR plasma is ignited to the magnetron plasma. Operating the magnetron at constant power, it was observed that its discharge current is raised from 1.8 A to 4.8 A, when the ECR discharge was superimposed with a microwave power of 2 kW. At the same time, the discharge voltage decreased from about 560 V to 210 V, clearly indicating a higher plasma density of the MECRIS mode. The optical emission spectrum of the MECRIS plasma is dominated by lines of excited Al atoms and shows a significant contribution of lines arising from singly ionized Al. Plasma emission photography with a CCD camera was used to prove probe measurements and to identify separated plasma emission zones originating from the ECR and magnetron discharge.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗