Flash Thermal Diffusivity Measurements and Inspection of Additively Manufactured Ti-6Al-4V Specimens with Varying Process Parameters

Flash thermal diffusivity measurements were obtained on additively manufactured Ti-6Al-4V disk shaped specimens with various process parameters. For additively manufactured metal parts, processing parameters such as laser power and scanning speed are critical to ensure the desired microstructure. For this study, the laser powder bed fusion process parameters were changed at various angular sections on a 21 mm diameter and 3.0 mm thick disk. The measurement of thermal diffusivity was performed by fitting a 1-dimensional thermal model to the data pixel by pixel to produce an inspection image. The image revealed the detection of defects such as lack of fusion porosity and areas of aggregated porosity. The thermal diffusivity imagery was compared to immersion scan ultrasonic and X-ray computed tomography (CT) measurements for validation. Based on these results, additional samples were investigated using a single side thermal inspection technique to detect lack of fusion porosity and near surface voids.

thermal nondestructive evaluation↗

Flash Thermal Diffusivity Measurements and Inspection of Additively Manufactured Ti-6Al-4V Specimens with Varying Process Parameters

Flash thermal diffusivity measurements were obtained on additively manufactured Ti-6Al-4V disk shaped specimens with various process parameters. For additively manufactured metal parts, processing parameters such as laser power and scanning speed are critical to ensure the desired microstructure. For this study, the laser powder bed fusion process parameters were changed at various angular sections on a 21 mm diameter and 3.0 mm thick disk. The measurement of thermal diffusivity was performed by fitting a 1-dimensional thermal model to the data pixel by pixel to produce an inspection image. The image revealed the detection of defects such as lack of fusion porosity and areas of aggregated porosity. The thermal diffusivity imagery was compared to immersion scan ultrasonic and X-ray computed tomography (CT) measurements for validation. Based on these results, additional samples were investigated using a single side thermal inspection technique to detect lack of fusion porosity and near surface voids.

thermal nondestructive evaluation↗

Thermal Inspection of Low Emissivity Surfaces Using a Pulsed Light Emitting Diodes (PLED) Heat Source

Thermal inspections of a structure typically utilize a flash or quartz lamp heat source located on the same side of an infrared camera. The heat source provides light energy for heating while the infrared camera measures the surface transient temperature response. The inspection can be difficult for low emissivity surfaces for several reasons. First, the high intensity light can reflect off the surface and cause “burn-in” to the camera’s detector. The “burn-in” can take time for the sensors to recover and potentially damage the detector. Secondly, the heat source after pulsing, has a transient cool down component. The cool down component can be reflected and therefore superimposed over the structure’s thermal response which can cause an error (false defect indications) in the inspection. Lastly, the heat source is spectrally broad and therefore while heating, infrared components of the heat source can produce non-uniformity in the measured temperature field. Typically for the inspection of reflective surfaces, paint or other emissivity enhancing coatings are applied before inspection. In this paper, a pulsed light emitting diodes (PLED) heat source is used. The PLED heat source is spectrally narrow, contained within the visible band, and therefore not detectable by the infrared camera. The PLED heat source is configured to reduce any transient cool down components that could produce false defect indications. The PLED thermal inspections are compared to commercially available flash thermography inspections on unpainted aluminum samples with simulated corrosion and additively manufactured Ti-6AL-4V metal specimens.

thermal nondestructive evaluation↗

Thermal Inspection of Low Emissivity Surfaces Using a Pulsed Light Emitting Diodes (PLED) Heat Source

Thermal inspections of a structure typically utilize a flash or quartz lamp heat source located on the same side of an infrared camera. The heat source provides light energy for heating while the infrared camera measures the surface transient temperature response. The inspection can be difficult for low emissivity surfaces for several reasons. First, the high intensity light can reflect off the surface and cause “burn-in” to the camera’s detector. The “burn-in” can take time for the sensors to recover and potentially damage the detector. Secondly, the heat source after pulsing, has a transient cool down component. The cool down component can be reflected and therefore superimposed over the structure’s thermal response which can cause an error (false defect indications) in the inspection. Lastly, the heat source is spectrally broad and therefore while heating, infrared components of the heat source can produce non-uniformity in the measured temperature field. Typically for the inspection of reflective surfaces, paint or other emissivity enhancing coatings are applied before inspection. In this paper, a pulsed light emitting diodes (PLED) heat source is used. The PLED heat source is spectrally narrow, contained within the visible band, and therefore not detectable by the infrared camera. The PLED heat source is configured to reduce any transient cool down components that could produce false defect indications. The PLED thermal inspections are compared to commercially available flash thermography inspections on unpainted aluminum samples with simulated corrosion and additively manufactured Ti-6AL-4V metal specimens.

thermal nondestructive evaluation↗

Detection and Localization of a Fold, Twist, and Overlaps within Tow-Steered Composite Panels During Autoclave Cure

Because of the anisotropic properties of carbon fiber reinforced polymer (CRFP) composites, novel layup architectures, such as tow-steering, can be used to tailor mechanical properties of the composite structure to the loading condition during use. In this work, a tow-steered composite panel was de-signed, laid up using the Integrated Structural Assembly of Advanced Com-posites (ISAAC) automated fiber placement (AFP) machine located at the NASA Langley Research Center (LaRC), and cured while simultaneously be-ing inspected using an ultrasonic inspection system operating inside the auto-clave. The composite panel contained overlaps that are intrinsic to the tow-steered design and had intentionally introduced layup defects including folds, wrinkles, splices, tow twists, foreign object debris (FOD), gaps, and additional overlaps. The inspections during the cure cycle focused on the ar-ea within the laminate containing a fold, a twist, and intrinsic overlaps. The ultrasonic inspections performed during the cure cycle were analyzed and compared to post-cure ultrasonic inspections of the entire laminate.

Composites↗

Detection and Localization of a Fold, Twist, and Overlaps within Tow-Steered Composite Panels During Autoclave Cure

Because of the anisotropic properties of carbon fiber reinforced polymer (CRFP) composites, novel layup architectures, such as tow-steering, can be used to tailor mechanical properties of the composite structure to the loading condition during use. In this work, a tow-steered composite panel was de-signed, laid up using the Integrated Structural Assembly of Advanced Com-posites (ISAAC) automated fiber placement (AFP) machine located at the NASA Langley Research Center (LaRC), and cured while simultaneously be-ing inspected using an ultrasonic inspection system operating inside the auto-clave. The composite panel contained overlaps that are intrinsic to the tow-steered design and had intentionally introduced layup defects including folds, wrinkles, splices, tow twists, foreign object debris (FOD), gaps, and additional overlaps. The inspections during the cure cycle focused on the ar-ea within the laminate containing a fold, a twist, and intrinsic overlaps. The ultrasonic inspections performed during the cure cycle were analyzed and compared to post-cure ultrasonic inspections of the entire laminate.

Composites↗