Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NOISE REDUCTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Application of an Aligned and Unaligned Signal Processing Technique to Investigate Tones and Broadband Noise in Fan and Contra-Rotating Open Rotor Acoustic Spectra

The study of noise from a two-shaft contra-rotating open rotor (CROR) is challenging since the shafts are not phase locked in most cases. Consequently, phase averaging of the acoustic data keyed to a single shaft rotation speed is not meaningful. An unaligned spectrum procedure that was developed to estimate a signal coherence threshold and reveal concealed spectral lines in turbofan engine combustion noise is applied to fan and CROR acoustic data in this paper (also available as NASA/TM-2015-218865). The NASA Advanced Air Vehicles Program, Advanced Air Transport Technology Project, Aircraft Noise Reduction Subproject supported the current work. The fan and open rotor data were obtained under previous efforts supported by the NASA Quiet Aircraft Technology (QAT) Project and the NASA Environmentally Responsible Aviation (ERA) Project of the Integrated Systems Research Program in collaboration with GE Aviation, respectively. The overarching goal of the Advanced Air Transport (AATT) Project is to explore and develop technologies and concepts to revolutionize the energy efficiency and environmental compatibility of fixed wing transport aircrafts. These technological solutions are critical in reducing the impact of aviation on the environment even as this industry and the corresponding global transportation system continue to grow.

Aeroacoustics↗

Application of Particle Image Velocimetry to a Study of Flow About a Multi-Element Airfoil

An experiment was performed on the flap tip vortex shed from a half span Fowler flap. This flap was mounted on a 5 foot span NACA 63(2)-215 Mod B airfoil in the 7 by 10 foot wind tunnel at NASA Ames Research Center. Several noise reduction studies were performed with this model, and the addition of the Particle Image Velocimetry (PIV) research discussed here served as a proof case of large scale PIV. The measurement plane investigated here was a cross plane region. This is cross plane relative to the freestream flow direction. The measurement plane was located at a position 18 inches downstream of the flap trailing edge. This served to prove that measurements could also be made in the more difficult cross plane direction rather than in the downstream flow direction. Lastly the PIV data was used as a practical research tool that yielded important results that could not otherwise be obtained. The flow field area measured was 40 cm by 40 cm square, and served to characterize the downstream flow characteristics of the flap tip vortex under three configurations: the baseline configuration which was the flap and the wing only; the baseline with the addition of a 3/4 span slat; and the baseline with a Flap Edge Device which was designed to reduce the noise generated at the flap. All configurations were tested at a freestream velocity of 64.84 m/s. The test resulted in average velocity fields for the three configurations tested. The velocity fields aided in verifying other testing methods on this particular experiment, and also yielded further insight into the characteristics of the flap tip vortex under the three configurations considered. The velocity data was reduced, and we were able to calculate the vorticity of the flow field. From the position of minimum vorticity the location of the center of the vortex was determined. The circulation was also calculated and aided in comparing the effects of the three configurations on the lifting characteristics of the flap.

Walker, Stephen M.↗

Analysis of Simulated and Experimental Noise Sources of Boeing 777 Main Gear Model via CLEAN in 3D

Previously obtained experimental and simulated phased microphone array data for the NASA 26%-scale model of a six-wheel main landing gear, with and without a toboggan-shaped noise reduction fairing, were analyzed using the CLEAN technique in three dimensions. The model is a high-fidelity representation of the Boeing 777-200 aircraft main landing gear. The reprocessing of the acoustic data was undertaken to address the deficiencies encountered in the source localization (beamform) maps and the integrated farfield spectra at mid to high frequencies in our previous study, where conventional array processing techniques were applied to the same data sets. Application of the CLEAN approach resulted in higher quality beamform maps with many of the previously observed side lobes either eliminated or suppressed significantly. As a result, integration of the experimentally and computationally based maps showed substantial improvement in the quality of the high-frequency spectral content relative to the corresponding spectra generated via conventional array processing, thus extending the good agreement achieved between the measured and predicted farfield spectra from 8 kHz to 14 kHz in model-scale frequencies. In addition, an examination of the simulated surface pressure fluctuations, off-surface flow field, and three-dimensionally constructed noise sources was conducted to determine the cause of the subtle discrepancies between measured and predicted sound pressure levels that occur in the 1,800 Hz to 4,000 Hz model-scale frequency range.

Ravetta, Patricio↗

Two-color continuous-variable quantum entanglement in a singly resonant optical parametric oscillator

We apply the input-output theory of optical cavities to formulate a quantum treatment of a continuous-wave singly resonant optical parametric oscillator. This case is mainly relevant to highly nondegenerate signal and idler modes. We show that both intensity and quadrature squeezing are present and that the maximum noise reduction below the standard quantum limit is the same at the signal and idler frequencies as in the doubly resonant case. As the threshold of oscillation is approached, however, the intensity-difference and quadrature spectra display a progressive line narrowing which is absent in the balanced doubly resonant case. By use of the separability criterion for continuous variables, the signal-idler state is found to be entangled over wide ranges of the parameters. We show that attainable levels of squeezing and entanglement make singly resonant configurations ideal candidates for two-color quantum information processes, because of their ease of tuning in experimental realizations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Parametric Mixer Design Methods for Acoustic Explorations of Internally Mixed Nozzles

As part of a jet noise reduction effort under the Commercial Supersonics Technology project, a process for the design and optimization of a parametric dual-stream lobe mixer is presented. The lobe mixer is fully defined from five independent parameters, including mixer length, lobe count, lobe penetration, lobe bias, and trailing edge slope. The mixers are inserted into an academic, constant-area nozzle with an external plug. The full geometry is meshed in Pointwise v18.4, and the RANS equations are solved in FUN3D v13.6. The results of a DoE study, involving ~80 different mixer designs, are presented, along with an associated parametric model for various performance response quantities. With a design space fully explored, observations and recommendations are given, and future work is discussed to further improve the design.

Dual-stream Mixer↗

A platform to measure isentropes from proton-heated warm dense matter on short pulse laser facilities

We describe the development of an experimental platform that measures the release isentrope of materials heated isochorically to temperatures of a few electron volts, using short-pulse laser-produced protons to heat the sample and long-pulse laser-produced x rays to perform streaked x-ray radiography. The density profiles derived from the radiography data are integrated to generate pressure–density isentropes, independent of prior knowledge of the equation of state of the sample material. In order to understand the sensitivities of isentrope extraction from radiography data, we analyze synthetic radiographs generated by a radiation hydrodynamics code. Noise reduction and high spatial resolution are critical for isentrope reconstruction, as demonstrated by the analysis of a proof-of-principle shot day on the OMEGA-EP facility. In conclusion, the data demonstrate the feasibility of the platform for characterizing isentropes, and we discuss the necessary improvements to enhance precision in differentiating between equation-of-state models.

Equations of state↗

Computer-aided measurement of liver volumes in CT by means of geodesic active contour segmentation coupled with level-set algorithms

Purpose: Computerized liver extraction from hepatic CT images is challenging because the liver often abuts other organs of a similar density. The purpose of this study was to develop a computer-aided measurement of liver volumes in hepatic CT. Methods: The authors developed a computerized liver extraction scheme based on geodesic active contour segmentation coupled with level-set contour evolution. First, an anisotropic diffusion filter was applied to portal-venous-phase CT images for noise reduction while preserving the liver structure, followed by a scale-specific gradient magnitude filter to enhance the liver boundaries. Then, a nonlinear grayscale converter enhanced the contrast of the liver parenchyma. By using the liver-parenchyma-enhanced image as a speed function, a fast-marching level-set algorithm generated an initial contour that roughly estimated the liver shape. A geodesic active contour segmentation algorithm coupled with level-set contour evolution refined the initial contour to define the liver boundaries more precisely. The liver volume was then calculated using these refined boundaries. Hepatic CT scans of 15 prospective liver donors were obtained under a liver transplant protocol with a multidetector CT system. The liver volumes extracted by the computerized scheme were compared to those traced manually by a radiologist, used as ''gold standard.''Results: The mean liver volume obtained with our scheme was 1504 cc, whereas the mean gold standard manual volume was 1457 cc, resulting in a mean absolute difference of 105 cc (7.2%). The computer-estimated liver volumetrics agreed excellently with the gold-standard manual volumetrics (intraclass correlation coefficient was 0.95) with no statistically significant difference (F=0.77; p(F{<=}f)=0.32). The average accuracy, sensitivity, specificity, and percent volume error were 98.4%, 91.1%, 99.1%, and 7.2%, respectively. Computerized CT liver volumetry would require substantially less completion time (compared to an average of 39 min per case by manual segmentation). Conclusions: The computerized liver extraction scheme provides an efficient and accurate way of measuring liver volumes in CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Acoustic Properties of Aerogels: Current Status and Prospects

Noise reduction remains an important priority in the modern society, in particular, for urban areas and highly populated cities. Insulation of buildings and transport systems such as cars, trains, and airplanes has accelerated the need to develop advanced materials. Various porous materials, such as commercially available foams and granular and fibrous materials, are commonly used for sound mitigating applications. In this review, a special class of advanced porous materials, aerogels, is examined, and an overview of the current experimental and theoretical status of their acoustic properties is provided. Aerogels can be composed of inorganic matter, synthetic or natural polymers, as well as organic/inorganic composites and hybrids. Aerogels are highly porous nanostructured materials with a large number of meso‐ and small macropores; the mechanisms of sound absorption partly differ from those of traditional porous absorbers possessing large macropores. The understanding of the acoustic properties of aerogels is far from being complete, and experimental results remain scattered. It is demonstrated that the structure of the aerogel provides a complex three‐dimensional architecture ideally suited for promising high‐performance materials for acoustic mitigation systems. This is in addition to the numerous other desirable properties that include low density, low thermal conductivity, and low refractive index.

36 MATERIALS SCIENCE↗

Hearing impairment and tinnitus among older construction workers employed at DOE facilities

Few studies have defined the risk of hearing impairment and tinnitus after retirement. This report measures hearing impairment and tinnitus prevalence among older construction trades workers. The study cohort included 21,340 participants in a national medical screening program. Audiometric hearing impairment was classified according to the Global Burden of Disease Study. Tinnitus was determined by self-report. An internal subcohort of nonconstruction trades workers served as a reference group. Stratified analyses and multivariate analyses were used to measure the prevalence of hearing impairment and tinnitus by age, sex, and job category. Prevalence of any hearing impairment was 55.2% (males, 57.7%; females, 26.8%) and increased rapidly with age. Construction trades workers were 40% more likely to have hearing impairment than the reference group. The overall prevalence of tinnitus was 46.52% and followed patterns similar to hearing impairment. Workers with hearing impairment were more likely to also have tinnitus, but tinnitus was frequently reported in the absence of measured hearing impairment. Hearing impairment and tinnitus prevalence were much higher in this study than in previous research. A significant reason for the difference is that BTMed follows participants after they have retired. To draw conclusions about the risk for work-related chronic diseases and disorders it is important to monitor workers through their lifetimes. Also, tinnitus by itself should be given greater significance. We report the findings reinforce the need to promote noise reduction and hearing conservation in construction.

60 APPLIED LIFE SCIENCES↗

Surface analysis insight note: Differentiation methods applicable to noisy data for determination of sp2‐ versus sp3‐hybridization of carbon allotropes and AES signal strengths

The derivatives of the spectra are commonly used for quantification in Auger Electron Spectroscopy (AES) spectra, while the derivative of the KLL C Auger line has proven to be valuable in obtaining a measure of the relative proportions of sp 2 ‐ and sp 3 ‐hybridization using the D‐parameter in both AES and X‐ray Photoelectron Spectroscopy (XPS). Differentiation of X‐ray Photoelectron Spectroscopy (XPS) and Auger Electron Spectroscopy (AES) spectra by numerical means is presented and illustrated for polymeric, such as PEEK and Nylon, as well as for graphitic materials including highly ordered pyrolytic graphite and graphene oxide. The most commonly available Savitzky–Golay method is explained mathematically and developed through the case of constructing a 5‐point quadratic polynomial convolution kernel suitable for differentiating spectra of adequate signal to noise. The concept of differentiation of spectra where signal to noise is less than adequate is also developed. Two alternative strategies to Savitzky–Golay differentiation are presented, which fit curves to data that allow derivatives to be obtained where Savitzky–Golay would otherwise fail. These alternative methods involve constructing a parametric curve that fits data over the entire energy interval of interest. Derivatives of spectra are then obtained by differentiating these parametric curves directly. A comparison of results for different materials for which specific sp 2 ‐ vs sp 3 ‐hybridized carbon proportions are of interest is used to emphasize the importance of characterizing methods used to differentiate spectra and understanding the characteristics of instrumentation used to measure spectra. The case for using Principal Component Analysis noise reduction with C KLL spectra is made for spectra collected from a heterogeneous graphene oxide sample.

Fairley, Neal↗

Neutron Detectors for Scattering Applications

The book covers, for the first time, the most common neutron detectors used in neutron scattering facilities and all of those in use at Oak Ridge National Lab. The first two chapters describe the facilities, instruments and the critical detector parameters needed by various instruments. The third chapter focuses on the key components of the 3He-based linear position sensitive detectors as well as on their electronics, which require particular attention to signal-processing and noise reduction. The fourth chapter is dedicated to the 3He alternatives where scintillators play a critical role. Finally, chapter 5 covers emerging neutron detection technologies including semiconductors, vacuum-based devices and their associated readouts, which will be required in the future for high rate and high-resolution neutron detectors.

Diawara, Yacouba↗

Multiscale Characterization of Additive Manufacturing Components with Computed Tomography, 3D X-ray Microscopy, and Deep Learning

Additive manufacturing (AM) facilitates the creation of complex-geometry parts, driving advancements in lightweight aerospace components, high-efficiency engine cooling channels, and customized medical implants. However, ensuring the quality and reliability of AM parts remains challenging due to internal defects, surface irregularities, porosity, and residual trapped powder, which are often inaccessible to traditional inspection methods. Recent developments in X-ray computed tomography (XCT) and 3D X-ray microscopy (XRM), particularly systems equipped with resolution-at-a-distance (RaaD™) capabilities, enable high-resolution, non-destructive evaluation of AM components across multiple scales, from sub-micrometer to macroscopic levels. This paper explores modern XCT and XRM techniques for multiscale characterization of AM parts, focusing on their ability to detect and analyze defects such as porosity, cracks, inclusions, and surface roughness, while offering insights into defect formation mechanisms, material properties, and process-induced variations. The integration of deep learning (DL) frameworks, including Simurgh, DeepRecon, and DeepScout, enhances XCT/XRM workflows by reducing scan times, improving resolution recovery, and enabling accurate defect detection even with limited projection data. These DL-based methods overcome limitations of traditional reconstruction techniques, enabling faster, more reliable characterization of dense materials like Inconel 718 and novel alloys such as AlCe. Applications include process parameter optimization, high-throughput quality control, and multistage AM process evaluation, with DL-enhanced workflows accelerating analysis times from weeks to days. Correlative imaging approaches further validate XCT and XRM data against scanning electron microscopy (SEM) images of physically sectioned samples, confirming the accuracy of DL-based reconstructions and enabling comprehensive defect analysis. While challenges remain in generalizing DL models to diverse materials and imaging conditions, improvements in resolution, noise reduction, and defect detection highlight the transformative potential of these methods. This multiscale and correlative approach enables precise identification and correlation of microstructural features with the overall performance of AM components. By integrating advanced XCT, XRM, and DL techniques, this paper demonstrates a significant leap forward in AM characterization, offering valuable insights into the relationships between processing parameters, microstructure, and part performance, and driving innovations that enhance the quality and reliability of AM products for demanding industrial applications.

Additive manufacturing↗

Avoiding full corrections in dynamic SPECT images impacts the performance of SPECT myocardial blood flow quantitation

Introduction: This study investigated the performance of SPECT myocardial blood flow (MBF) quantitation lacking full physical corrections (All Corr) in dynamic SPECT (DySPECT) images. Methods: Eleven healthy normal volunteers (HVT) and twenty-four patients with angiography-documented CAD were assessed. All Corr in {sup 99m}Tc-sestamibi DySPECT encompassed noise reduction (NR), resolution recovery (RR), and corrections for scatter (SC) and attenuation (AC), otherwise no correction (NC) or only partial corrections. The performance was evaluated by quality index (R{sup 2}) and blood-pool spillover index (FBV) in kinetic modeling, and by rest flow (RMBF) and stress flow (SMBF) compared with those of All Corr. Results: In HVT group, NC diminished 2-fold flow uniformity with the most degraded quality (15%-18% reduced R{sup 2}) and elevated spillover effect (45%-50% increased FBV). Consistently higher RMBF and SMBF were discovered in both groups (HVT 1.54/2.31 higher; CAD 1.60/1.72; all P < .0001). Bland-Altman analysis revealed positive flow bias (HVT 0.9-2.6 mL/min/g; CAD 0.7-1.3) with wide ranges of 95% CI of agreement (HVT NC −1.9-7.1; NR −0.4-4.4; NR + SC −1.1-4.3; NR + SC + RR −0.7-2.5) (CAD NC −1.2-3.8; NR −1.0-2.8; NR + SC −1.0-2.5; NR + SC + RR −1.1-2.6). Conclusions: Uncorrected physical interference in DySPECT images can extensively impact the performance of MBF quantitation. Full physical corrections should be considered to warrant this tool for clinical utilization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reconstruction of concrete microstructure using complementarity of X-ray and neutron tomography

The concrete microstructure was successfully reconstructed using the complementarity of X-ray and neutron computed tomography (CT). Neither tomogram alone was found to be suitable to properly describe the microstructure of concrete under this study. However, by merging the information revealed by the two modalities, and using image segmentation, noise reduction, and image registration techniques we reconstruct the concrete microstructure. Void, aggregate, and cement paste phases are successfully captured down to the images' spatial resolution, even though the aggregate consists of multiple minerals. The coarse-aggregate volume fraction of the reconstructed microstructure was similar to that of the mixing proportions. Furthermore, image-based finite element analysis is performed to demonstrate the effects of microstructure on stress concentration and strain localization.

36 MATERIALS SCIENCE↗

EUTERPE: A global gyrokinetic code for stellarator geometry

The current state of the EUTERPE code is described with emphasis on the implemented models and their numerical implementation. The code solves the multi-species electromagnetic gyrokinetic equations in the full volume of a three-dimensional domain. Noise reduction of the particle-in-cell method is achieved by using a δf-method and Fourier filters. The field equations are discretized with B-splines and the resulting system of equations is solved iteratively. For linear simulations a phase-factor transformation is applied in order to strongly reduce the necessary grid resolution. Apart from the full gyrokinetic model, other numerically less expensive hybrid models are also implemented. They are mainly tailored for comparison with fluid theory and for studying the interaction of the bulk plasma with fast particles. The code is parallelized for CPUs by particle and domain decomposition. Good scalability up to several thousand nodes is demonstrated.

97 MATHEMATICS AND COMPUTING↗

Unlocking hidden information in sparse small-angle neutron scattering measurements

Hypothesis Small-Angle Neutron Scattering (SANS) is a powerful technique for studying soft matter systems such as colloids, polymers, and lyotropic phases, providing nanoscale structural insights. However, its effectiveness is limited by low neutron flux, leading to long acquisition times and noisy data. Here, we hypothesize that Bayesian statistical inference using Gaussian Process Regression (GPR) can reconstruct high-fidelity scattering data from sparse measurements by leveraging intensity smoothness and continuity. Experiments and Simulations The method was benchmarked computationally and validated through SANS experiments on various soft matter systems, including wormlike micelles, colloidal suspensions, polymeric structures, and lyotropic phases. GPR-based inference was applied to both experimental and synthetic data to evaluate its effectiveness in noise reduction and intensity reconstruction. Findings GPR significantly enhances SANS data quality and therefore reducing measurement times by up to two orders of magnitude. This cost-effective approach maximizes experimental efficiency, enabling high-throughput studies and real-time monitoring of dynamic systems. It is particularly beneficial for weakly scattering and time-sensitive studies. Beyond SANS, this framework applies to other low-SNR techniques, including laboratory-based small-angle X-ray scattering and various dynamical scattering methods. Furthermore, it offers transformative potential for compact neutron sources, enhancing their viability for structural analysis in resource-limited settings.

Small angle neutron scattering↗

Multiscale geometric modeling of macromolecules I: Cartesian representation

This paper focuses on the geometric modeling and computational algorithm development of biomolecular structures from two data sources: Protein Data Bank (PDB) and Electron Microscopy Data Bank (EMDB) in the Eulerian (or Cartesian) representation. Molecular surface (MS) contains non-smooth geometric singularities, such as cusps, tips and self-intersecting facets, which often lead to computational instabilities in molecular simulations, and violate the physical principle of surface free energy minimization. Variational multiscale surface definitions are proposed based on geometric flows and solvation analysis of biomolecular systems. Our approach leads to geometric and potential driven Laplace–Beltrami flows for biomolecular surface evolution and formation. The resulting surfaces are free of geometric singularities and minimize the total free energy of the biomolecular system. High order partial differential equation (PDE)-based nonlinear filters are employed for EMDB data processing. We show the efficacy of this approach in feature-preserving noise reduction. After the construction of protein multiresolution surfaces, we explore the analysis and characterization of surface morphology by using a variety of curvature definitions. Apart from the classical Gaussian curvature and mean curvature, maximum curvature, minimum curvature, shape index, and curvedness are also applied to macromolecular surface analysis for the first time. Our curvature analysis is uniquely coupled to the analysis of electrostatic surface potential, which is a by-product of our variational multiscale solvation models. As an expository investigation, we particularly emphasize the numerical algorithms and computational protocols for practical applications of the above multiscale geometric models. Such information may otherwise be scattered over the vast literature on this topic. Based on the curvature and electrostatic analysis from our multiresolution surfaces, we introduce a new concept, the polarized curvature, for the prediction of protein binding sites.

97 MATHEMATICS AND COMPUTING↗

A practical discrete-adjoint method for high-fidelity compressible turbulence simulations

Methods and computing hardware advances have enabled accurate predictions of complex compressible turbulence phenomena, such as the generation of jet noise that motivates the present effort. However, limited understanding of underlying physical mechanisms restricts the utility of such predictions since they do not, by themselves, indicate a route to design improvements. Gradient-based optimization using adjoints can circumvent the flow complexity to guide designs, though this is predicated on the availability of a sufficiently accurate solution of the forward and adjoint systems. These are challenging to obtain, since both the chaotic character of the turbulence and the typical use of discretizations near their resolution limits in order to efficiently represent its smaller scales will amplify any approximation errors made in the adjoint formulation. Formulating a practical exact adjoint that avoids such errors is especially challenging if it is to be compatible with state-of-the-art simulation methods used for the turbulent flow itself. Automatic differentiation (AD) can provide code to calculate a nominally exact adjoint, but existing general-purpose AD codes are inefficient to the point of being prohibitive for large-scale turbulence simulations. Here, we analyze the compressible flow equations as discretized using the same high-order workhorse methods used for many high-fidelity compressible turbulence simulations, and formulate a practical space–time discrete-adjoint method without changing the basic discretization. A key step is the definition of a particular discrete analog of the continuous norm that defines our cost functional; our selection leads directly to an efficient Runge–Kutta-like scheme, though it would be just first-order accurate if used outside the adjoint formulation for time integration, with finite-difference spatial operators for the adjoint system. Its computational cost only modestly exceeds that of the flow equations. We confirm that its accuracy is limited by computing precision, and we demonstrate it on the aeroacoustic control of a mixing layer with a challengingly broad range of turbulence scales. For comparison, the error from a corresponding discretization of the continuous-adjoint equations is quantified to potentially explain its limited success in past efforts to control jet noise. The differences are illuminating: the continuous-adjoint is shown to suffer from exponential error growth in (reverse) time even for the best-resolved largest turbulence scales. Implications for jet noise reduction and turbulence control in general are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗