Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Multiplex”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Development of high-resolution muon tracking systems based on micro-pattern detectors

A muon tracking system consisting of four 9 cm x 10 cm sized bulk Micromegas detectors with 128 {mu}m amplification-gap and two 10 cm x 10 cm triple GEM detectors is foreseen for high-precision tracking of 140 GeV muons at the H8 beamline at CERN with a rate of up to 10 kHz and an overall resolution below 40 {mu}m. Larger detectors with an active area of 0.5 m{sup 2} and more are under development for detector studies in high neutron or gamma ray background environments at the Gamma Irradiation Facility at CERN and the Munich tandem accelerator. Signal studies of both detector types have been performed by recording cosmic muon and 5.9 keV X-ray signals with a single charge-sensitive preamplifier using several gas-mixtures of Ar:CO{sub 2}. The signals were digitized using 1 GHz VME based flashADCs with 2520 sampling points. The analysis of the complete signal-cycles allows for the determination of rise times, pulse heights, timing fluctuations and discrimination of background, resulting in a FWHM energy resolution of about 20% and detection efficiencies of 99% and more. Models for signal formation in both detector types will be presented. The single detector spatial resolution of 80 {mu}m was measured using a fast Gassiplex based strip readout with readout strips of 150 {mu}m width and a pitch of 250 {mu}m. The Gassiplex readout, formerly used at the HERMES experiment, had to be substantially adapted. No more crosstalk or non-linearities were observed after reconfiguration of the multiplexing amplifier on the front-end boards. The observed spatial resolution is limited by multiple scattering of the cosmic muons used in the laboratory. We also report on the sensitivity to gamma- and neutron background and on the behaviour of spatial resolution as a function of background rates. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AIDA: A 16-channel amplifier ASIC to read out the advanced implantation detector array for experiments in nuclear decay spectroscopy

We have designed a read-out ASIC for nuclear decay spectroscopy as part of the AIDA project - the Advanced Implantation Detector Array. AIDA will be installed in experiments at the Facility for Antiproton and Ion Research in GSI, Darmstadt. The AIDA ASIC will measure the signals when unstable nuclei are implanted into the detector, followed by the much smaller signals when the nuclei subsequently decay. Implant energies can be as high as 20 GeV; decay products need to be measured down to 25 keV within just a few microseconds of the initial implants. The ASIC uses two amplifiers per detector channel, one covering the 20 GeV dynamic range, the other selectable over a 20 MeV or 1 GeV range. The amplifiers are linked together by bypass transistors which are normally switched off. The arrival of a large signal causes saturation of the low-energy amplifier and a fluctuation of the input voltage, which activates the link to the high-energy amplifier. The bypass transistors switch on and the input charge is integrated by the high-energy amplifier. The signal is shaped and stored by a peak-hold, then read out on a multiplexed output. Control logic resets the amplifiers and bypass circuit, allowing the low-energy amplifier to measure the subsequent decay signal. We present simulations and test results, demonstrating the AIDA ASIC operation over a wide range of input signals. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fibre optic extensometer for high radiation and high temperature nuclear applications

In the framework of the Joint Instrumentation Laboratory (LCI), gathering resources from SCK-CEN (Belgium) and CEA (France), we are developing an optical sensor in order to accurately measure radiation-induced elongation of material placed in the core of a Material Testing Reactor (MTR). This extensometer displays common advantages of Fibre Optic (FO) sensors: high resolution, easy remote sensing and multiplexing, and also compact size which is of particular interest for in pile experiments with little room available. In addition, light weight reduces gamma heating hence limiting the thermal effect. In accordance with the specifications, the sensor has preferably two fixing points defining a gauge length of 10 to 15 mm (as a minimum). The diameter is less than 2 mm. Intense gamma and neutron irradiation as well as high temperatures are the most difficult environment conditions to withstand. Reactor radiation produces huge losses in common optical fibre. The losses can be limited by selecting the fibres (mainly with high purity silica core), the wavelength range (800-1200 nm), and a measurement based on interferometry (largely insensitive to losses in the fibre thanks to the wavelength encoding of the useful signal). Heavy neutron - mainly - and gamma flux such as in MTR, also produce compaction of silica, resulting in a significant drift and preventing the use of commercial FO sensors in such environment. Knowing this issue we revised the basic scheme of Extrinsic Fabry Perot Interferometer (EFPI) in order to limit the effects of compaction. A first sensor prototype fixed on a stainless steel support was tested in the Smirnof test facility in the BR2 MTR in Mol (Belgium). The support was subject to a constant mechanical and thermal stress, and his dimensions were not supposed to vary. This test showed a very low drift of the revisited EPFI design under high irradiation field in comparison with a commercial EFPI. This result has to be confirmed with second generation sensors with an increased robustness. The other difficulty to face is high temperature. Fibre optics with metal coating allows safe operation under temperatures up to 400 deg.C and even higher. But differential dilatation between silica and typical metallic material produces differential elongation in the range of 0.5 10{sup -2} i.e 5000{mu}{epsilon} for an increase in temperature of 300-400 deg. C. Such large elongation has to be considered carefully in the sensor design and its fixing on the sample. Laboratory tests with a second generation of adapted sensors demonstrated their good accuracy: less than 1% error over a displacement of 100{mu}m (< 1 {mu}m error), at room temperature. The displacement measured can reach 250{mu}m (20000{mu}{epsilon} with a gauge length of 12.5 mm) or more. We are currently implementing metal-coated fibre and we are preparing the next in pile irradiation on the BR2 reactor scheduled for mid-2011. Other applications of the sensor can be considered. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Characterising Encapsulated Nuclear Waste using Cosmic-ray Muon Tomography (MT)

A prototype scintillating-fibre detector system has been developed at the University of Glasgow in collaboration with the UK National Nuclear Laboratory (NNL) for the nondestructive assay of UK legacy nuclear waste containers. This system consists of four tracking modules, two above and two below the container under interrogation. Each module consists of two orthogonal planes of 2 mm-pitch fibres yielding one space point. Per plane, 128 fibres are read out by a single Hamamatsu H8500 64-channel MAPMT with two fibres multiplexed onto each pixel. The configuration allows the reconstruction of the incoming and scattered muon trajectories, thus enabling the container content, with respect to atomic number Z, to be determined. Results are shown from experimental data collected for high-Z objects within an air matrix and within a shielded, concrete-filled container. These reconstructed images show clear discrimination between the low, medium and high-Z materials present, with dimensions and positions determined with sub-centimetre precision. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Active SOC Balancing for a Multi-Chemistry Battery Pack with Reduced Number of Converters

In energy storage systems using second-life or multi-chemistry cells, an active state of charge (SOC) balancing system can prolong pack life and enhance performance by utilizing the healthier cells more than those which are heavily degraded. However, the high cost of the active balancing system, particularly in converter-based solutions, prevents their widespread usage. Considering this, existing research has proposed numerous balancing systems utilizing only one converter. However, such systems may compromise the balancing speed too much. Therefore, this work proposes two active balancing systems with a reduced number of converters for 14-16 series-connected cells. One system uses two converters for direct cell-to-cell balancing. The other uses a time-multiplexed approach to exchange energy via an auxiliary low-voltage (LV) bus using four converters. The proposed balancing systems are compared to two baseline systems, a single converter cell-to-cell balancing system, and a 14 converter balancing system with an auxiliary LV bus.

battery pack↗

Resource Allocation for Single Carrier Massive MIMO Systems

Resource allocation in orthogonal frequency division multiplexing (OFDM) systems is performed through allocating blocks of subcarriers to each user. Even though OFDM is the primary waveform for 5G NR systems, research reports have noted that single carrier modulation (SCM) offers several advantages over OFDM in massive multiple input multiple output (MIMO) systems, making it a preferred candidate for some future applications such as massive machine type communications (mMTC). This paper presents a method for SCM resource allocation and the relevant information recovery algorithms at the receiver. Our emphasis is on cyclic prefixed SCM, where highly flexible and efficient frequency domain detection algorithms enable the operation of many simultaneous users in a massive MIMO uplink scenario. The proposed resource allocation method allows the number of users to exceed the number of antennas at the base station (BS). Each single carrier transmission is partitioned into L interleaved streams, and each user is allocated a number of such streams. One major benefit of SCM is that each data symbol is spread over the entire bandwidth. As such, the receiver performance is dictated by the average channel gain across the transmission band rather than the channel gain at a given frequency bin or a small group of frequencies. In the proposed setup, each stream may be thought of as a resource block in SCM, analogous to resource blocks in OFDM. Hence, in the context of this paper, the terms resource blocks and streams may be used interchangeably.

5G and Beyond Communications↗

Design of Fair Charging Algorithm for Smart Electrical Vehicle Charging Infrastructure

Smart charging infrastructure is required to meet the growing demand for Electrical Vehicle (EV) charging from ever more abundant EV owners. WINSmartEV™ is a software based smart charging infrastructure that can monitor, control and manage EV charging. It also can use multiplexing to share scarce charging resources among different EVs plugged in simultaneously. By default WINSmartEV™ uses a round-robin algorithm to schedule charging time between EVs charging on the 120V level one charging device. In order to enhance user acceptance of this technology, charge time allocation fairness is defined and an algorithm to enhance this fairness is proposed.

Chung, Ching-Yen↗

Smart Electric Vehicle Charging Infrastructure Overview

WINSmartEV™ is a smart electric vehicle charging system that has been built and is currently in operation. It is a software and network based EV charging system designed and built around the ideas of intelligent charge scheduling, multiplexing (connecting multiple vehicles to each circuit) and flexibility. This paper gives an overview of this smart charging system with an eye toward its unique features and capabilities.

Chynoweth, Joshua↗

All-Optical Frequency Processor for Networking Applications

Herein, we propose an electro-optic approach for transparent optical networking, in which frequency channels are actively transformed into any desired mapping in a wavelength-multiplexed environment. Based on electro-optic phase modulators and Fourier-transform pulse shapers, our all-optical frequency processor (AFP) is examined numerically for the specific operations of frequency channel hopping and broadcasting, and found capable of implementing these transformations with favorable component requirements. Extending our analysis via a mutual-information–based metric for system optimization, we show how to optimize transformation performance under limited resources in a classical context, contrasting the results with those found using metrics motivated by quantum information, such as fidelity and success probability. Given its compatibility with on-chip implementation, as well as elimination of optical-to-electrical conversion in frequency channel switching, the AFP looks to offer valuable potential in silicon photonic network design, as well as the realization of high-dimensional frequency-bin gates.

42 ENGINEERING↗

An Open Source Perovskite Solar Cell Curve Tracer

When developing systems for perovskite solar cells (PSCs), it is important to have a testing platform that closely resembles your deployed systems. While developing a 1 U CubeSat, the Big Red Sat-1 at the University of Nebraska-Lincoln, we found a lack of passive curve tracing instrumentation, which we needed for our mission. To that end, we developed a benchtop passive curve tracer that leverages the Ossila Solar Simulator as an AM1.5 light source. This device utilizes a ladder of switched resistors and a precision voltage and current measurement to achieve the curve tracing. It also integrates a common-anode multiplexer to switch through multipixel PSCs. Finally, the solar cell holder is separate from the main measurement system, so various substrates sizes and pixel counts can be supported. This system is tested using various PSCs. It has been open sourced to enable reuse in future systems that may benefit from the lower power consumption and flight heritage.

14 SOLAR ENERGY↗

Time-Frequency Warped Waveforms for Well-Contained Massive Machine Type Communications

Herein this paper proposes a novel time-frequency warped waveform for short symbols, massive machine-type communication (mMTC), and internet of things (IoT) applications. The waveform is composed of asymmetric raised cosine (RC) pulses to increase the signal containment in time and frequency domains. The waveform has low power tails in the time domain, hence better performance in the presence of delay spread and time offsets. The time-axis warping unitary transform is applied to control the waveform occupancy in time-frequency space and to compensate for the usage of high roll-off factor pulses at the symbol edges. The paper explains a step-by-step analysis for determining the roll-off factors profile and the warping functions. Gains are presented over the conventional Zero-tail Discrete Fourier Transform-spread-Orthogonal Frequency Division Multiplexing (ZT-DFT-s-OFDM), and Cyclic prefix (CP) DFT-s-OFDM schemes in the simulations section.

42 ENGINEERING↗

Adaptive OFDM Radar Waveform Design for Improved Micro-Doppler Estimation

Here we analyze the performance of a wideband orthogonal frequency division multiplexing (OFDM) signal in estimating the micro-Doppler frequency of a rotating target having multiple scattering centers. The use of a frequency-diverse OFDM signal enables us to independently analyze the micro-Doppler characteristics with respect to a set of orthogonal subcarrier frequencies. We characterize the accuracy of micro-Doppler frequency estimation by computing the Cramer-Rao bound (CRB) on the angular-velocity estimate of the target. Additionally, to improve the accuracy of the estimation procedure, we formulate and solve an optimization problem by minimizing the CRB on the angular-velocity estimate with respect to the OFDM spectral coefficients. We present several numerical examples to demonstrate the CRB variations with respect to the signal-to-noise ratios, number of temporal samples, and number of OFDM subcarriers. We also analysed numerically the improvement in estimation accuracy due to the adaptive waveform design. A grid-based maximum likelihood estimation technique is applied to evaluate the corresponding mean-squared error performance.

47 OTHER INSTRUMENTATION↗

An Automated Microfluidic Assay for Photonic Crystal Enhanced Detection and Analysis of an Antiviral Antibody Cancer Biomarker in Serum

Here, we report on the implementation of an automated platform for detecting the presence of an antibody biomarker for human papillomavirus-associated oropharyngeal cancer from a single droplet of serum, in which a nanostructured photonic crystal surface is used to amplify the output of a fluorescence-linked immunosorbent assay. The platform is comprised of a microfluidic cartridge with integrated photonic crystal chips that interfaces with an assay instrument that automates the introduction of reagents, wash steps, and surface drying. Upon assay completion, the cartridge interfaces with a custom laser-scanning instrument that couples light into the photonic crystal at the optimal resonance condition for fluorescence enhancement. The instrument is used to measure the fluorescence intensity values of microarray spots corresponding to the biomarkers of interest, in addition to several experimental controls that verify correct functioning of the assay protocol. In this work, we report both dose-response characterization of the system using anti-E7 antibody introduced at known concentrations into serum and characterization of a set of clinical samples from which results were compared with a conventional enzyme-linked immunosorbent assay (ELISA) performed in microplate format. Finally, the demonstrated capability represents a simple, rapid, automated, and high-sensitivity method for multiplexed detection of protein biomarkers from a low-volume test sample.

59 BASIC BIOLOGICAL SCIENCES↗

Characterization of Quantum Frequency Processors

Frequency-bin qubits possess unique synergies with wavelength-multiplexed lightwave communications, suggesting valuable opportunities for quantum networking with the existing fiber-optic infrastructure. Although the coherent manipulation of frequency-bin states requires highly controllable multi-spectral-mode interference, the quantum frequency processor (QFP) provides a scalable path for gate synthesis leveraging standard telecom components. Here, we summarize the state of the art in experimental QFP characterization. Distinguishing between physically motivated “open box” approaches that treat the QFP as a multiport interferometer, and “black box” approaches that view the QFP as a general quantum operation, we highlight the assumptions and results of multiple techniques, including quantum process tomography of a tunable beamsplitter—to our knowledge the first full process tomography of any frequency-bin operation. Our findings should inform future characterization efforts as the QFP increasingly moves beyond proof-of-principle tabletop demonstrations toward integrated devices and deployed quantum networking experiments.

42 ENGINEERING↗

Warping Functions Design for Long Warped ZT-DFT-s-OFDM

Time-frequency warped waveform is a novel type of well-contained waveform composed of raised cosine (RC) pulses with roll-off factors profile customized for spectrally efficient signal containment. The waveform is suited for massive machine-type communication (mMTC), and Internet-of-Things (IoT) applications. The paper is a follow-up to the original work of time-frequency warped waveforms; here, we are proposing a warping function suited for length-independent symbols, which is missing from the previous work. The paper proposes the design steps starting from a piecewise warping function with parts of straight segments and other curved parts. A maximum Out-of-band leakage is used as a criterion to determine the warping function parameters. The roll-off factors profile determined in the previous study is used as a minimum bound for the leakage limits. Gains are presented over Windowed Zero-tail Discrete Fourier Transform-spread-Orthogonal Frequency Division Multiplexing (ZT-DFT-s-OFDM) in the simulations section.

Ibrahim, Mostafa↗

Beamline Spectroscopy of Integrated Circuits With Hard X-Ray Transition Edge Sensors at the Advanced Photon Source

At Argonne National Laboratory, we are developing hard X-ray (2 to 20 keV) Transition Edge Sensor (TES) arrays for beamline science. The significantly improved energy resolution provided by superconducting detectors compared to semiconductor-based energy-dispersive detectors, but with better collection efficiency than wavelength-dispersive instruments, will enable greatly improved X-ray emission and absorption spectroscopic measurements. Additionally, a prototype instrument with 24 microwave-frequency multiplexed pixels is now in testing at the Advanced Photon Source (APS) 1-BM beamline. Initial measurements show an energy resolution ten times better (150 eV compared to < 15 eV) than the silicon-drift detectors currently available to APS beamline users, and in particular demonstrate the ability to resolve closely-spaced emission lines in samples containing multiple transition metal elements, such as integrated circuits. Comparing fluorescence spectra of integrated circuits measured with our TESs at the beamline to those measured with silicon detectors, we find emission lines and elements largely hidden (e.g. Hf alongside Cu) from a semiconductor-based detector but well resolved by a TES. This directly shows the strengths of TES-based instruments in fluorescence mapping.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Hyperspectral X-ray Imaging: Progress Towards Chemical Analysis in the SEM

The Hyperspectral X-ray Imaging (HXI) project will enable non-destructive chemical-state determination of nano-scale samples in the electron microscope for nuclear safeguards applications. To efficiently measure chemical state through electron-excited X-ray emission requires a combination of wide spectral bandwidth, high resolution, and high count rate capability. We are building a next-generation X-ray detector based on an array of transition edge sensors (TESs) to make these measurements possible and routine in the scanning electron microscope (SEM). Leveraging the large pixel densities afforded by microwave multiplexing readout and continuous, uninterrupted operation of a cryogen-free dilution refrigerator, this instrument will have efficiency to allow chemical species identification of nano-scale samples in hours instead of days to weeks. We describe prototype pixel designs for this HXI instrument, comprising three pixel types that will make up the hybrid TES array. Engineering design of the integrated HXI cryostat and SEM system is in progress, with full detector commissioning expected in Spring 2021 followed closely by full-scale integration with the SEM. Furthermore, we also report on the commissioning of a complementary TES-based X-ray emission spectroscopy platform for bulk samples to build a spectral library for HXI sample identification.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

PAPR-Constrained Pareto-Optimal Waveform Design for OFDM-STAP Radar

We propose a peak-to-average power ratio (PAPR) constrained Pareto-optimal waveform design approach for an orthogonal frequency division multiplexing (OFDM) radar signal to detect a target using the space-time adaptive processing (STAP) technique. The use of an OFDM signal does not only increase the frequency diversity of our system, but also enables us to adaptively design the OFDM coefficients in order to further improve the system performance. First, we develop a parametric OFDM-STAP measurement model by considering the effects of signaldependent clutter and colored noise. Then, we observe that the resulting STAP-performance can be improved by maximizing the output signal-to-interference-plus-noise ratio (SINR) with respect to the signal parameters. However, in practical scenarios, the computation of output SINR depends on the estimated values of the spatial and temporal frequencies and target scattering responses. Therefore, we formulate a PAPR-constrained multi-objective optimization (MOO) problem to design the OFDM spectral parameters by simultaneously optimizing four objective functions: maximizing the output SINR, minimizing two separate Cramer-Rao bounds (CRBs) on the normalized spatial and temporal frequencies, and minimizing the trace of CRB matrix on the target scattering coefficients estimations. We present several numerical examples to demonstrate the achieved performance improvement due to the adaptive waveform design.

Sen, Satyabrata↗