Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Minimum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Effects of substrate temperature on properties of ITO-ZnO composition spread films fabricated by combinatorial RF magnetron sputtering

We have fabricated ITO-ZnO composition spread films to investigate the effects of substrate temperature on their electrical and optical properties by using combinatorial RF magnetron sputtering. It turned out by X-ray measurement that the film with zinc contents above 16.0 at% [Zn/(In+Zn+Sn)] showed amorphous phase regardless of substrate temperature. The amorphous ITO-ZnO film had lower resistivity than polycrystalline films. When the films were deposited at 250 deg. C, the minimum resistivity of 3.0x10{sup -4} OMEGA cm was obtained with the zinc contents of 16.0 at%. The indium content could be reduced as high as {approx}30 at% compared to that of ITO for the films having similar resistivity ({approx}10{sup -4} OMEGA cm). However, a drastic increase of resistivity was observed for the ITO-ZnO films deposited at 350 deg. C, having zinc contents below 15.2 at%. - Graphical abstract: The effects of substrate temperature on properties of ITO-ZnO films were investigated by using combinatorial RF magnetron sputtering. The amorphous ITO-ZnO film had lower resistivity than polycrystalline films. The minimum resistivity of 3.0x10{sup -4} OMEGA cm was obtained with the substrate temperature of 250 deg. C and the zinc contents of 16.0 at%. The electronic states of ITO-ZnO films were discussed with related to the formation of transparent amorphous oxide semiconductor (TAOS).

36 MATERIALS SCIENCE↗

A new continuous two-step molecular precursor route to rare-earth oxysulfides Ln{sub 2}O{sub 2}S

A continuous two-step molecular precursor pathway is designed for the preparation of rare-earth oxysulfides Ln{sub 2}O{sub 2}S (Ln=Y, La, Pr, Nd, Sm-Lu). This new route involves a first oxidation step leading to the rare-earth oxysulfate Ln{sub 2}O{sub 2}SO{sub 4} which is subsequently reduced to the rare-earth oxysulfide Ln{sub 2}O{sub 2}S by switching to a H{sub 2}-Ar atmosphere. The whole process occurs at a temperature significantly lower than usual solid state synthesis (T{<=}650 Degree-Sign C) and avoids the use of dangerous sulfur-based gases, providing a convenient route to the synthesis of the entire series of Ln{sub 2}O{sub 2}S. The molecular precursors consist in heteroleptic dithiocarbamate complexes [Ln(Et{sub 2}dtc){sub 3}(phen)] and [Ln(Et{sub 2}dtc){sub 3}(bipy)] (Et{sub 2}dtc=N,N-diethyldithiocarbamate; phen=1,10-phenanthroline; bipy=2,2 Prime -bipyridine) and were synthesized by a new high yield and high purity synthesis route. The nature of the molecular precursor determines the minimum synthesis temperature and influences therefore the purity of the final Ln{sub 2}O{sub 2}S crystalline phase. - Graphical abstract: A continuous two-step molecular precursor pathway was designed for the preparation of rare-earth oxysulfides Ln{sub 2}O{sub 2}S (Ln=Y, La, Pr, Nd, Sm-Lu), starting from heteroleptic dithiocarbamate complexes. The influence of the nature of the molecular precursor on the minimum synthesis temperature and on the purity of the final Ln{sub 2}O{sub 2}S crystalline phase is discussed. Highlights: Black-Right-Pointing-Pointer A new high yield and high purity synthesis route of rare earth dithiocarbamates is described. Black-Right-Pointing-Pointer These compounds are used as precursors in a continuous process leading to rare-earth oxysulfides. Black-Right-Pointing-Pointer The oxysulfides are obtained under much more moderate conditions than previously described.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Crystal structure, magnetism and transport properties of Ce{sub 3}Ni{sub 25.75}Ru{sub 3.16}Al{sub 4.1}B{sub 10}

Single crystals of Ce{sub 3}Ni{sub 25.75}Ru{sub 3.16}Al{sub 4.1}B{sub 10} were obtained from a process in which a polycrystalline sample of CeRu{sub 2}Al{sub 2}B was annealed in an excess of a Ni–In flux. The initial phase, CeRu{sub 2}Al{sub 2}B, does not recrystallize, instead, crystals of a new phase, Ce{sub 3}Ni{sub 25.75}Ru{sub 3.16}Al{sub 4.1}B{sub 10}, could be isolated once the flux was removed. The title compound crystallizes in the tetragonal space group P4/nmm (No. 129) with a=1139.02(8), c=801.68(6) pm (c/a=0.70) in the Nd{sub 3}Ni{sub 29}Si{sub 4}B{sub 10} structure type. Electrical resistivity measurements reveal metallic behavior with a minimum of 700 µΩ cm and a small residual resistivity ratio of RRR=1.4 indicating a large amount of disorder scattering. The cerium atoms are either in the 4+ or an intermediate valence state with a valence fluctuation temperature far above room temperature. - Graphical abstract: Single crystals of Ce{sub 3}Ni{sub 25.75}Ru{sub 3.16}A{sub l4.1}B{sub 10} were obtained using a process in which a polycrystalline sample of CeRu{sub 2}Al{sub 2}B was annealed in an excess of a Ni–In flux. Electrical resistivity measurements reveal metallic behavior with a minimum of 700 μΩ cm and a small residual resistivity ratio of RRR=1.4 indicating a large amount of disorder scattering. The cerium atoms are either in the 4+ or an intermediate valence state with a valence fluctuation temperature far above room temperature. Display Omitted - Highlights: • Flux synthesis of high quality single crystals of Ce{sub 3}Ni{sub 25.75}Ru{sub 3.16}Al{sub 4.1}B{sub 10} is presented along with the crystal structure, magnetic and transport properties. • The compound is isostructural to Nd{sub 3}Ni{sub 29}Si{sub 4}B{sub 10} but is first of this structure type showing mixed occupancies of d-elements. • This is an intermetallic phase with Ce in either the 4+ or an intermediate valence state. • The fact that this structure with mixed occupied transition metal sites exists suggests that more compounds of this type should be accessible and the physical properties tuned.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Material properties of perovskites in the quasi-ternary system LaFeO{sub 3}–LaCoO{sub 3}–LaNiO{sub 3}

An overview is presented on the variation of electrical conductivity, oxygen permeation, and thermal expansion coefficient as a function of the composition of perovskites in the quasi-ternary system LaFeO{sub 3}–LaCoO{sub 3}–LaNiO{sub 3}. Powders of thirteen nominal perovskite compositions were synthesized under identical conditions by the Pechini method. The powder X-ray diffraction data of two series, namely La(Ni{sub 0.5}Fe{sub 0.5}){sub 1−x}Co{sub x}O{sub 3} and LaNi{sub 0.5-x}Fe{sub x}Co{sub 0.5}O{sub 3}, are presented after the powders had been sintered at 1100 °C for 6 h in air. The measurements revealed a rhombohedral structure for all compositions except LaNi{sub 0.5}Fe{sub 0.5}O{sub 3} for which 60% rhombohedral and 40% orthorhombic phase was found. The maximum DC electrical conductivity value of the perovskites at 800 °C was 1229 S cm{sup −1} for the composition LaCoO{sub 3} and the minimum was 91 S cm{sup −1} for the composition LaCo{sub 0.5}Fe{sub 0.5}O{sub 3}. The oxygen permeation of samples with promising conductivities at 800 °C was one order of magnitude lower than that of La{sub 0.6}Sr{sub 0.4}Co{sub 0.8}Fe{sub 0.2}O{sub 3} (LSCF). The highest value of 0.017 ml cm{sup −2} min{sup −1} at 950 °C was obtained with LaNi{sub 0.5}Co{sub 0.5}O{sub 3}. The coefficients of thermal expansion varied in the range of 13.2×10{sup −6} K{sup −1} and 21.9×10{sup −6} K{sup −1} for LaNi{sub 0.5}Fe{sub 0.5}O{sub 3} and LaCoO{sub 3}, respectively. {sup 57}Fe Mössbauer spectroscopy was used as probe for the oxidation states, local environment and magnetic properties of iron ions as a function of chemical composition. The substitution had a great influence on the chemical properties of the materials. - Graphical abstract: Compositional dependence of isothermal electrical conductivity at 800 °C and thermal expansion coefficient in the series La(Fe{sub 0.5}Ni{sub 0.5}){sub (1−x)}Co{sub x}O{sub 3} and LaNi{sub 0.5−x}Fe{sub x}Co{sub 0.5}O{sub 3}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Configurations, band structures and photocurrent responses of 4-(4-oxopyridin-1(4H)-yl)phthalic acid and its metal-organic frameworks

4-(4-oxopyridin-1(4 H)-yl)phthalic acid (H{sub 2}L) and three H{sub 2}L-based metal-organic frameworks (MOFs) formulated as ZnL(DPE)(H{sub 2}O)·H{sub 2}O (DPE=(E)-1, 2-di(pyridine −4-yl)ethene) (1), CdL(H{sub 2}O){sub 2} (2) and CdL (3) were synthesized and structurally characterized by single-crystal X-ray diffraction. The free H{sub 2}L ligand shows an enol-form and the L{sup 2−} ligand in the three MOFs exists as the keto-form. Density functional theory (DFT) calculations indicate H{sub 2}L and the three MOFs possess different band structures. Due to the existence of the N-donor, DPE in MOF 1, the conduction band (CB) minimum and band gap of MOF 1 are much lower than those of H{sub 2}L. And MOF 1 yielded much larger photocurrent density than H{sub 2}L upon visible light illumination. Electrochemical impedance spectroscopy (EIS) shows the interfacial charge transfer impedance in the presence of MOF 1 is lower than that in the presence of H{sub 2}L. The hydrous MOF 2 and the anhydrous MOF 3 are both constructed by Cd(II) and L{sup 2−}, and they can be reversibly transformed to each other. However, MOFs 2 and 3 possess different CB minimums and VB maximums, and their band gaps are much larger than that of MOF 1. - Graphical abstract: The free ligand, 4-(4-oxopyridin-1(4H)-yl)phthalic acid (H{sub 2}L) shows different configuration from its three MOFs, and they possess different band structures. MOF 1 yielded much larger visible-light-driven photocurrent density than H{sub 2}L. The hydrous MOF 2 and the anhydrous MOF 3 can be transformed to each other, and they have larger band gaps than MOF 1.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrical properties and water incorporation in A-site deficient perovskite La{sub 1−x}Ba{sub x}Nb{sub 3}O{sub 9−0.5x}

Barium doped A-site deficient perovskites La{sub 1−x}Ba{sub x}Nb{sub 3}O{sub 9−0.5x} (x=0–0.05) were synthesized by the solid state method, their structure, electrical properties and state of oxygen-hydrogen groups have been investigated. These phases were found to be able to incorporate water from the gas phase and to exhibit proton transport. Hydration is accompanied by the formation of different forms of oxygen-hydrogen groups: OH{sup −} – groups and H{sub 3}O{sup +} – ions. The total conductivities of doped samples increased in a wet atmosphere due to the appearance of proton current carriers (at the temperatures below 700 °C), but the conductivity increased insignificantly (~0.25 order of magnitude) because of a low doping level and, consequently, small concentration of protons. TG-measurements confirmed relatively low water content (below 0.2%). The total conductivity depends substantially on x and exhibits a minimum on σ−f(x) dependencies. It has been suggested that such behavior is a manifestation of a mixed cation effect. - Highlights: • Barium doped perovskites La{sub 1−x}Ba{sub x}Nb{sub 3}O{sub 9−0.5x} (x=0–0.05) are capable to incorporate water from the gas phase and to exhibit proton transport. • The hydration is accompanied by the formation of OH{sup −} – groups and H{sub 3}O{sup +} – ions. • The total conductivity exhibits a minimum on σ−f(x) dependencies as a result of a mixed cation effect.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanocrystalline Cs{sub x}WO{sub 3} particles: Effects of N{sub 2} annealing on microstructure and near-infrared shielding characteristics

In order to further improve the near-infrared shielding properties of cesium tungsten bronze (Cs{sub x}WO{sub 3}) for solar filter applications, Cs{sub x}WO{sub 3} particles were prepared by solvothermal reaction method and the effects of nitrogen annealing on the microstructure and near-infrared shielding properties of Cs{sub x}WO{sub 3} were investigated. The obtained Cs{sub x}WO{sub 3} samples were characterized by X-ray diffraction, scanning electron microscopy, transmission electron microscopy, X-ray photoelectron spectroscopy and spectrophotometer. The results indicate that nanosheet-like Cs{sub x}WO{sub 3} particles with hexagonal structure began to transform into nanorods after annealed at temperature higher than 600 °C. The near-infrared shielding properties of Cs{sub x}WO{sub 3} particles could be further improved by N{sub 2} annealing at 500–700 °C. Particularly, the 500 °C-annealed Cs{sub x}WO{sub 3} samples in the N{sub 2} atmosphere showed best near-infrared shielding properties. It was suggested that the excellent near-infrared shielding ability of the 500 °C-annealed Cs{sub x}WO{sub 3} samples is correlated with its minimum O/W atomic ratio and most oxygen vacancies. Highlights: • N{sub 2} annealing could further improve the near-infrared (NIR) shielding of Cs{sub x}WO{sub 3}. • Effects of N{sub 2} annealing on microstructure and NIR shielding of Cs{sub x}WO{sub 3} were studied. • The 500 °C-N{sub 2}-annealed Cs{sub x}WO{sub 3} exhibited minimum O/W ratio and most oxygen vacancies. • The 500 °C-N{sub 2}-annealed Cs{sub x}WO{sub 3} particles exhibited best NIR shielding properties.

36 MATERIALS SCIENCE↗

Effects of Sn addition on the microstructure, mechanical properties and corrosion behavior of Ti–Nb–Sn alloys

Ti and Ti alloys are widely used in restorative surgery because of their good biocompatibility, enhanced mechanical behavior and high corrosion resistance in physiological media. The corrosion resistance of Ti-based materials is due to the spontaneous formation of the TiO{sub 2} oxide film on their surface, which exhibits elevated stability in biological fluids. Ti–Nb alloys, depending on the composition and the processing routes to which the alloys are subjected, have high mechanical strength combined with low elastic modulus. The addition of Sn to Ti–Nb alloys allows the phase transformations to be controlled, particularly the precipitation of ω phase. The aim of this study is to discuss the microstructure, mechanical properties and corrosion behavior of cast Ti–Nb alloys to which Sn has been added. Samples were centrifugally cast in a copper mold, and the microstructure was characterized using optical microscopy, scanning electron microscopy and X-ray diffractometry. Mechanical behavior evaluation was performed using Berkovich nanoindentation, Vickers hardness and compression tests. The corrosion behavior was evaluated in Ringer's solution at room temperature using electrochemical techniques. The results obtained suggested that the physical, mechanical and chemical behaviors of the Ti–Nb–Sn alloys are directly dependent on the Sn content. - Graphical abstract: Effects of Sn addition to the Ti–30Nb alloy on the elastic modulus. - Highlights: • Sn addition causes reduction of the ω phase precipitation. • Minimum Vickers hardness and elastic modulus occurred for 6 wt.% Sn content. • Addition of 6 wt.% Sn resulted in maximum ductility and minimum compression strength. • All Ti–30Nb–XSn (X = 0, 2, 4, 6, 8 and 10%) alloys are passive in Ringer's solution. • Highest corrosion resistance was observed for 6 wt.% Sn content.

36 MATERIALS SCIENCE↗

Improvement of band gap profile in Cu(InGa)Se{sub 2} solar cells through rapid thermal annealing

Highlights: • Proper RTA treatment can effectively optimize band gap profile to more expected level. • Inter-diffusion of atoms account for the improvement of the graded band gap profile. • The variation of the band gap profile created an absolute gain in the efficiency by 1.22%. - Abstract: In the paper, the effect of rapid thermal annealing on non-optimal double-graded band gap profiles was investigated by using X-ray photoelectron spectroscopy and capacitance–voltage measurement techniques. Experimental results revealed that proper rapid thermal annealing treatment can effectively improve band gap profile to more optimal level. The annealing treatment could not only reduce the values of front band gap and minimum band gap, but also shift the position of the minimum band gap toward front electrode and enter into space charge region. In addition, the thickness of Cu(InGa)Se{sub 2} thin film decreased by 25 nm after rapid thermal annealing treatment. All of these modifications were attributed to the inter-diffusion of atoms during thermal treatment process. Simultaneously, the variation of the band gap profile created an absolute gain in the efficiency by 1.22%, short-circuit current density by 2.16 mA/cm{sup 2} and filled factor by 3.57%.

36 MATERIALS SCIENCE↗

The crystal structure and electrical properties of K{sub 2}NiF{sub 4}-type (Ca{sub 2−x}Sm{sub x})MnO{sub 4}

Graphical abstract: The relationship between log ρ of K{sub 2}NiF{sub 4}-type (Ca{sub 2−x}Sm{sub x})MnO{sub 4} and 1000/T. - Highlights: • K{sub 2}NiF{sub 4}-type (Ca{sub 2−x}Sm{sub x})MnO{sub 4} was synthesized using a polymerized complex route. • The semiconductive samples had minimum values of ρ and E{sub a} at x = 0.1. • The log ρ–1/T curve of x = 0.3 consisted of two different lines at 315 K. • The 1/χ − T curve of x = 0.3 had a peak at 325 K. • These results indicated the presence of a charge-ordering transition at x = 0.3. - Abstract: K{sub 2}NiF{sub 4}-type (Ca{sub 2−x}Sm{sub x})MnO{sub 4} (0.02 ≤ x ≤ 0.3) was synthesized using a polymerized complex route. The crystal structure changed from tetragonal to orthorhombic at x = 0.3. A variation in the lattice parameters was explained by the Mn–O(2) distance, the Mn−O(2)−Mn angle, and the (Ca,Sm)–(Ca,Sm) distance. The samples were n-type semiconductors, and the minimum values of electrical resistivity (ρ) and an energy gap (E{sub g}) at x = 0.1 were accounted by electron transfer through an Mn−O(2)−Mn path and overlap between the Mnt{sub 2g} and Op{sub π} orbitals. In the sample (x = 0.3), the log ρ–1000/T curve consisted of two different lines that intersected at ca. 325 K, and a peak was observed at ca. 315 K in the magnetic susceptibility–temperature curve. These results indicated the presence of a charge-ordering (CO) transition at 315–325 K.

36 MATERIALS SCIENCE↗

A Novel Method of Island Blocking in Whole Abdominal Radiotherapy Using a Modified Electronic Tissue Compensation Technique

Traditionally, large fields requiring island blocking used external beam radiation therapy (EBRT) with Cerrobend blocks to limit dose to the critical structures. It is laborious to construct blocks and use them on a daily basis. We present a novel technique for island blocking using a modified electronic tissue compensation (MECOMP) technique. Five patients treated at our institution were selected for this study. The study compared two planning techniques: a novel MECOMP and a conventional EBRT technique. Conventional fields were defined using anterior-posterior and posterior-anterior (PA) fields. The kidneys were contoured and an aperture cut-out block was fitted to the OAR with a 1-cm margin (OAR{sub CTV}) and placed in the PA field. A dynamic multileaf collimation (DMLC) plan with ECOMP was developed using identical beam and blocking strategy; this tissue compensation-based fluence map was modified to deliver a 'zero' dose to the CTV{sub OAR} from the PA field. There were no significant differences in the mean, maximum, and minimum doses to the right or left kidney between the two methods. The mean, maximum, and minimum doses to the peritoneal cavity were also not significantly different. The number of monitor units (MUs) required was increased using the MECOMP (273 vs. 1152, p < 0.01). The MECOMP is effectively able to deliver DMLC-based radiotherapy, even with island blocks present. This novel use of MECOMP for whole abdominal radiotherapy should substantially reduce the labor, daily treatment time, and treatment-related errors through the elimination of cerrobend blocks.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric Comparison of Helical Tomotherapy and Dynamic Conformal Arc Therapy in Stereotactic Radiosurgery for Vestibular Schwannomas

The dosimetric results of stereotactic radiosurgery (SRS) for vestibular schwannoma (VS) performed using dynamic conformal arc therapy (DCAT) with the Novalis system and helical TomoTherapy (HT) were compared using plan quality indices. The HT plans were created for 10 consecutive patients with VS previously treated with SRS using the Novalis system. The dosimetric indices used to compare the techniques included the conformity index (CI) and homogeneity index (HI) for the planned target volume (PTV), the comprehensive quality index (CQI) for nine organs at risk (OARs), gradient score index (GSI) for the dose drop-off outside the PTV, and plan quality index (PQI), which was verified using the plan quality discerning power (PQDP) to incorporate 3 plan indices, to evaluate the rival plans. The PTV ranged from 0.27-19.99 cm{sup 3} (median 3.39 cm{sup 3}), with minimum required PTV prescribed doses of 10-16 Gy (median 12 Gy). Both systems satisfied the minimum required PTV prescription doses. HT conformed better to the PTV (CI: 1.51 {+-} 0.23 vs. 1.94 {+-} 0.34; p < 0.01), but had a worse drop-off outside the PTV (GSI: 40.3 {+-} 10.9 vs. 64.9 {+-} 13.6; p < 0.01) compared with DCAT. No significant difference in PTV homogeneity was observed (HI: 1.08 {+-} 0.03 vs. 1.09 {+-} 0.02; p = 0.20). HT had a significantly lower maximum dose in 4 OARs and significant lower mean dose in 1 OAR; by contrast, DCAT had a significantly lower maximum dose in 1 OAR and significant lower mean dose in 2 OARs, with the CQI of the 9 OARs = 0.92 {+-} 0.45. Plan analysis using PQI (HT 0.37 {+-} 0.12 vs. DCAT 0.65 {+-} 0.08; p < 0.01), and verified using the PQDP, confirmed the dosimetric advantage of HT. However, the HT system had a longer beam-on time (33.2 {+-} 7.4 vs. 4.6 {+-} 0.9 min; p < 0.01) and consumed more monitor units (16772 {+-} 3803 vs. 1776 {+-} 356.3; p < 0.01). HT had a better dose conformity and similar dose homogeneity but worse dose gradient than DCAT. Plan analysis confirmed the dosimetric advantage of HT, although not all indices revealed a better outcome for HT. Whether this dosimetric advantage translates into a clinical benefit deserves further investigation.

61 RADIATION PROTECTION AND DOSIMETRY↗

RapidArc radiotherapy planning for prostate cancer: Single-arc and double-arc techniques vs. intensity-modulated radiotherapy

RapidArc is a novel technique using arc radiotherapy aiming to achieve intensity-modulated radiotherapy (IMRT)-quality radiotherapy plans with shorter treatment time. This study compared the dosimetric quality and treatment efficiency of single-arc (SA) vs. double-arc (DA) and IMRT in the treatment of prostate cancer. Fourteen patients were included in the analysis. The planning target volume (PTV), which contained the prostate gland and proximal seminal vesicles, received 76 Gy in 38 fractions. Seven-field IMRT, SA, and DA plans were generated for each patient. Dosimetric quality in terms of the minimum PTV dose, PTV hotspot, inhomogeneity, and conformity index; and sparing of rectum, bladder, and femoral heads as measured by V70, V-40, and V20 (% of volume receiving >70 Gy, 40 Gy, and 20 Gy, respectively), treatment efficiency as assessed by monitor units (MU) and treatment time were compared. All plan objectives were met satisfactorily by all techniques. DA achieved the best dosimetric quality with the highest minimum PTV dose, lowest hotspot, and the best homogeneity and conformity. It was also more efficient than IMRT. SA achieved the highest treatment efficiency with the lowest MU and shortest treatment time. The mean treatment time for a 2-Gy fraction was 4.80 min, 2.78 min, and 1.30 min for IMRT, DA, and SA, respectively. However, SA also resulted in the highest rectal dose. DA could improve target volume coverage and reduce treatment time and MU while maintaining equivalent normal tissue sparing when compared with IMRT. SA achieved the greatest treatment efficiency but with the highest rectal dose, which was nonetheless within tolerable limits. For busy units with high patient throughput, SA could be an acceptable option.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetry estimation on variations of patient size in prostate volumetric-modulated arc therapy

This study investigated the dosimetric variations of the target and critical organs of patients who had weight loss associated with prostate volumetric-modulated arc therapy (VMAT). Five patients with prostate volumes ranging from 32–86.5 cm{sup 3} were selected from a group of 30 patients. Prostate VMAT plans were carried out on each patient using the 6-MV photon beam with a single 360° arc. Decrease of patient size as a result of weight loss was mimicked by contracting the patient's external contour in the anterior, left, and right directions with depths from 0.5–2 cm. Soft tissue excluded by the contracted external contour was replaced by air and the dose distribution was recalculated using the same beam geometry and dose prescription. Dose-volume histograms and dose-volume points such as D99% and D5% for the planning target volume (PTV), clinical target volume (CTV), rectum, bladder, and femoral heads were calculated with variations of reduced depth. In addition, the minimum, maximum, and mean doses for the target and critical organs were determined. PTV and CTV D99% were found to have increased 2.86 ± 0.30% per cm and 2.75 ± 0.38% per cm of reduced depth ranging from 0.5–2 cm. Moreover, the rectal and bladder D30% increased 2.20 ± 0.20% per cm and 2.31 ± 0.83% per cm, and the femoral head D5% increased 3.30 ± 0.11% per cm of reduced depth. Results from variations of the minimum, maximum, and mean doses of the PTV, CTV, rectum, bladder, and femoral heads showed that there was a >5% increase of dose when the reduced depth reached 2 cm. This study provided dosimetry estimation for radiation oncology staff to justify dose variations of the target and critical organs when patients' weight loss occurred in prostate VMAT. Dose variations >5% were seen when the patients' reduced depth was equal to 2 cm.

61 RADIATION PROTECTION AND DOSIMETRY↗

Bolus-dependent dosimetric effect of positioning errors for tangential scalp radiotherapy with helical tomotherapy

The dosimetric effect of errors in patient position is studied on-phantom as a function of simulated bolus thickness to assess the need for bolus utilization in scalp radiotherapy with tomotherapy. A treatment plan is generated on a cylindrical phantom, mimicking a radiotherapy technique for the scalp utilizing primarily tangential beamlets. A planning target volume with embedded scalplike clinical target volumes (CTVs) is planned to a uniform dose of 200 cGy. Translational errors in phantom position are introduced in 1-mm increments and dose is recomputed from the original sinogram. For each error the maximum dose, minimum dose, clinical target dose homogeneity index (HI), and dose-volume histogram (DVH) are presented for simulated bolus thicknesses from 0 to 10 mm. Baseline HI values for all bolus thicknesses were in the 5.5 to 7.0 range, increasing to a maximum of 18.0 to 30.5 for the largest positioning errors when 0 to 2 mm of bolus is used. Utilizing 5 mm of bolus resulted in a maximum HI value of 9.5 for the largest positioning errors. Using 0 to 2 mm of bolus resulted in minimum and maximum dose values of 85% to 94% and 118% to 125% of the prescription dose, respectively. When using 5 mm of bolus these values were 98.5% and 109.5%. DVHs showed minimal changes in CTV dose coverage when using 5 mm of bolus, even for the largest positioning errors. CTV dose homogeneity becomes increasingly sensitive to errors in patient position as bolus thickness decreases when treating the scalp with primarily tangential beamlets. Performing a radial expansion of the scalp CTV into 5 mm of bolus material minimizes dosimetric sensitivity to errors in patient position as large as 5 mm and is therefore recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric evaluation of integrated IMRT treatment of the chest wall and supraclavicular region for breast cancer after modified radical mastectomy

To investigate the dosimetric characteristics of irradiation of the chest wall and supraclavicular region as an integrated volume with intensity-modulated radiation therapy (IMRT) after modified radical mastectomy. This study included 246 patients who received modified radical mastectomy. The patients were scanned with computed tomography, and the chest wall (with or without the internal mammary lymph nodes) and supraclavicular region were delineated. For 143 patients, the chest wall and supraclavicular region were combined as an integrated planning volume and treated with IMRT. For 103 patients, conventional treatments were employed with 2 tangential fields for the chest wall, abutting a mixed field of 6-MV x-rays (16 Gy) and 9-MeV electrons (34 Gy) for the upper supraclavicular region. The common prescription dose was 50 Gy/25 Fx/5 W to 90% of the target volume. The dosimetric characteristics of the chest wall, the supraclavicular region, and normal organs were compared. For the chest wall target, compared with conventional treatments, the integrated IMRT plans lowered the maximum dose, increased the minimum dose, and resulted in better conformity and uniformity of the target volume. There was an increase in minimum, average, and 95% prescription dose for the integrated IMRT plans in the supraclavicular region, and conformity and uniformity were improved. The V{sub 30} of the ipsilateral lung and V{sub 10}, V{sub 30}, and mean dose of the heart on the integrated IMRT plans were lower than those of the conventional plans. The V{sub 5} and V{sub 10} of the ipsilateral lung and V{sub 5} of the heart were higher on the integrated IMRT plans (p < 0.05) than on conventional plans. Without an increase in the radiation dose to organs at risk, the integrated IMRT treatment plans improved the dose distribution of the supraclavicular region and showed better dose conformity and uniformity of the integrated target volume of the chest wall and supraclavicular region.

61 RADIATION PROTECTION AND DOSIMETRY↗

Intensity-modulated radiation therapy for pancreatic and prostate cancer using pulsed low–dose rate delivery techniques

Reirradiation of patients who were previously treated with radiotherapy is vastly challenging. Pulsed low–dose rate (PLDR) external beam radiotherapy has the potential to reduce normal tissue toxicities while providing significant tumor control for recurrent cancers. This work investigates treatment planning techniques for intensity-modulated radiation therapy (IMRT)-based PLDR treatment of various sites, including cases with pancreatic and prostate cancer. A total of 20 patients with clinical recurrence were selected for this study, including 10 cases with pancreatic cancer and 10 with prostate cancer. Large variations in the target volume were included to test the ability of IMRT using the existing treatment planning system and optimization algorithm to deliver uniform doses in individual gantry angles/fields for PLDR treatments. Treatment plans were generated with 10 gantry angles using the step-and-shoot IMRT delivery technique, which can be delivered in 3-minute intervals to achieve an effective low dose rate of 6.7 cGy/min. Instead of dose constraints on critical structures, ring structures were mainly used in PLDR-IMRT optimization. In this study, the PLDR-IMRT plans were compared with the PLDR-3-dimensional conformal radiation therapy (3DCRT) plans and the PLDR-RapidArc plans. For the 10 cases with pancreatic cancer that were investigated, the mean planning target volume (PTV) dose for each gantry angle in the PLDR-IMRT plans ranged from 17.6 to 22.4 cGy. The maximum doses ranged between 22.9 and 34.8 cGy. The minimum doses ranged from 8.2 to 17.5 cGy. For the 10 cases with prostate cancer that were investigated, the mean PTV doses for individual gantry angles ranged from 18.8 to 22.6 cGy. The maximum doses per gantry angle were between 24.0 and 34.7 cGy. The minimum doses per gantry angle ranged from 4.4 to 17.4 cGy. A significant reduction in the organ at risk (OAR) dose was observed with the PLDR-IMRT plan when compared with that using the PLDR-3DCRT plan. The volume receiving an 18-Gy (V{sub 18}) dose for the left and right kidneys was reduced by 10.6% and 12.5%, respectively, for the pancreatic plans. The volume receiving a 45-Gy (V{sub 45}) dose for the small bowel decreased from 65.3% to 45.5%. For the cases with prostate cancer, the volume receiving a 40-Gy (V{sub 40}) dose for the bladder and the rectum was reduced significantly by 25.1% and 51.2%, respectively. When compared with the RapidArc technique, the volume receiving a 30-Gy (V{sub 30}) dose for the left and the right kidneys was lower in the IMRT plans. For most OARs, no significant differences were observed between the PLDR-IMRT and the PLDR-RapidArc plans. These results clearly demonstrated that the PLDR-IMRT plan was suitable for PLDR pancreatic and prostate cancer treatments in terms of the overall plan quality. A significant reduction in the OAR dose was achieved with the PLDR-IMRT plan when compared with that using the PLDR-3DCRT plan. For most OARs, no significant differences were observed between the PLDR-IMRT and the PLDR-RapidArc plans. When compared with the PLDR-3DCRT plan, the PLDR-IMRT plan could provide superior target coverage and normal tissue sparing for PLDR reirradiation of recurrent pancreatic and prostate cancers. The PLDR-IMRT plan is an effective treatment choice for recurrent cancers in most cancer centers.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric comparison of intensity-modulated solutions for intact prostate cancer

The purpose of this study is intended to investigate the implementation of a modified class solution for intact prostate intensity-modulated radiation therapy (IMRT). The class solution uses 2 additional optimization structures intended to increase target conformity and decrease unnecessary dose to healthy tissue. A total of 10 randomly selected intact prostate IMRT patients were chosen for this retrospective study. Each of the original IMRT plans was compared with a modified class solution. The class solution implemented 2 additional optimization structures. The 95{sub O}PT was intended to increase target conformity, and the Avoidance{sub 3}780 was intended to reduce normal tissue. Each plan was evaluated for minimum, maximum, and mean doses to the target. Additionally, mean normal tissue dose, total monitor units (MUs), and segments were investigated. Conformity index and normal healthy index were also compared. All comparisons were evaluated using a paired t-test using GraphPad software. Evaluations of MUs; segments; minimum, maximum, mean target doses; mean normal tissue dose; and conformity index did not demonstrate a significant difference between the modified class solution and the original plans. However, evaluation of healthy tissue conformity index indicated a significant difference. Overall, 70% of the original plans failed to demonstrate a satisfactory score (< 0.6) of properly sparing normal healthy tissue, whereas 70% of the modified plans exhibited a satisfactory score (> 0.6). Most (90%) of the modified plans demonstrated a greater number of segments than the compared original plan. A modified class solution provides a good starting point for planning intact prostate cancer. The addition of the Avoidance{sub 3}780 structure increases the healthy tissue conformity index score.

61 RADIATION PROTECTION AND DOSIMETRY↗