Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measurement_method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Internal electric-field-lines distribution in CdZnTe detectors measured using X-ray mapping

The ideal operation of CdZnTe devices entails having a uniformly distributed internal electric field. Such uniformity especially is critical for thick long-drift-length detectors, such as large-volume CPG and 3-D multi-pixel devices. Using a high-spatial resolution X-ray mapping technique, we investigated the distribution of the electric field in real devices. Our measurements demonstrate that in thin detectors, <5 mm, the electric field-lines tend to bend away from the side surfaces (i.e., a focusing effect). In thick detectors, >1 cm, with a large aspect ratio (thickness-to-width ratio), we observed two effects: the electric field lines bending away from or towards the side surfaces, which we called, respectively, the focusing field-line distribution and the defocusing field-line distribution. In addition to these large-scale variations, the field-line distributions were locally perturbed by the presence of extended defects and residual strains existing inside the crystals. We present our data clearly demonstrating the non-uniformity of the internal electric field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A dynamic soil chamber system coupled with a tunable diode laser for online measurements of delta-13C, delta-18O, and efflux rate of soil respired CO2

High frequency observations of the stable isotopic composition of CO(2) effluxes from soil have been sparse due in part to measurement challenges. We have developed an open-system method that utilizes a flow-through chamber coupled to a tunable diode laser (TDL) to quantify the rate of soil CO(2) efflux and its delta(13)C and delta(18)O values (delta(13)C(R) and delta(18)O(R), respectively). We tested the method first in the laboratory using an artificial soil test column and then in a semi-arid woodland. We found that the CO(2) efflux rates of 1.2 to 7.3 micromol m(-2) s(-1) measured by the chamber-TDL system were similar to measurements made using the chamber and an infrared gas analyzer (IRGA) (R(2) = 0.99) and compared well with efflux rates generated from the soil test column (R(2) = 0.94). Measured delta(13)C and delta(18)O values of CO(2) efflux using the chamber-TDL system at 2 min intervals were not significantly different from source air values across all efflux rates after accounting for diffusive enrichment. Field measurements during drought demonstrated a strong dependency of CO(2) efflux and isotopic composition on soil water content. Addition of water to the soil beneath the chamber resulted in average changes of +6.9 micromol m(-2) s(-1), -5.0 per thousand, and -55.0 per thousand for soil CO(2) efflux, delta(13)C(R) and delta(18)O(R), respectively. All three variables initiated responses within 2 min of water addition, with peak responses observed within 10 min for isotopes and 20 min for efflux. The observed delta(18)O(R) was more enriched than predicted from temperature-dependent H(2)O-CO(2) equilibration theory, similar to other recent observations of delta(18)O(R) from dry soils (Wingate L, Seibt U, Maseyk K, Ogee J, Almeida P, Yakir D, Pereira JS, Mencuccini M. Global Change Biol. 2008; 14: 2178). The soil chamber coupled with the TDL was found to be an effective method for capturing soil CO(2) efflux and its stable isotope composition at high temporal frequency.

59 BASIC BIOLOGICAL SCIENCES↗

Characterization of Thin Films and Coatings

Just as the numbers and types of thin films have grown dramatically, the needs and approaches for their characterization have also expanded significantly. Adequate characterization of a film or coating depends on the process to create the coating as well as the planned or potential application(s) and expected lifetime. Characterization of a coating or film necessarily requires application of methods that determine properties of the coating and not primarily the substrate. This places some focus on methods that determine properties of layers and not "bulk" material. However, the increasing importance of micro- and nano-structures in coatings and films places an increased importance in methods with high spatial resolution. The growing use of organic films and coatings and the importance of molecular functionalization of inorganic surfaces increase the importance for different types of molecular characterization tools. In most circumstances appropriate characterization requires use of a combination of tools. The purpose of this chapter is to provide an introduction to the basic methods and overview applications for some of the most important tools for characterization of films, coatings and surfaces. The chapter will be organized in six sections: • Technique Overview – This section provides a high level summary of the types of information that can be obtained by different methods and includes information about their sensitivity and resolution. • Incident Photon Methods – Techniques involving incident photons are described and some brief examples of application are shown. Methods included are: x-ray photoelectron spectroscopy (XPS), x-ray diffraction (XRD), x-ray reflectivity (XRR), Fourier transform infra-red spectroscopy (FTIR), laser Raman spectroscopy, ellipsometry, and photoluminescence spectroscopy. • Incident Ion Methods - Methods initiated by ion irradiation are summarized including: Rutherford backscattering spectrometry (RBS), nuclear reaction analysis (NRA), ion channeling, elastic recoil detection analysis (ERDA), secondary ion mass spectrometry (SIMS), glow discharge mass spectrometry and uses of focused ion beams (FIB) (often in combination with scanning electron microscopy). • Incident Electron Methods – Methods involving incident electrons include: Auger electron spectroscopy (AES), scanning electron microscopy (SEM), energy dispersive x-ray analysis (EDS), transmission electron microscopy (TEM), and electron diffraction (low energy electron diffraction [LEED] and reflection high energy electron diffraction [RHEED]). • Other Methods – Additional methods described include scanning probe microscopy (SPM) (including scanning tunneling microscopy [STM] and atomic force microscopy [AFM]) and atom probe microscopy.

36 MATERIALS SCIENCE↗

DEVELOPMENT OF BURN TEST SPECIFICATIONS FOR FIRE PROTECTION MATERIALS IN RAM PACKAGES

The regulations in 10 CFR 71 require that the radioactive material (RAM) packages must be able to withstand specific fire conditions given in 10 CFR 71.73 during Hypothetical Accident Conditions (HAC). This requirement is normally satisfied by extensive testing of full scale test specimens under required test conditions. Since fire test planning and execution is expensive and only provides a single snapshot into a package performance, every effort is made to minimize testing and supplement tests with results from computational thermal models. However, the accuracy of such thermal models depends heavily on the thermal properties of the fire insulating materials that are rarely available at the regulatory fire temperatures. To the best of authors knowledge no test standards exist that could be used to test the insulating materials and derive their thermal properties for the RAM package design. This paper presents a review of the existing industry fire testing standards and proposes testing methods that could serve as a standardized specification for testing fire insulating materials for use in RAM packages.

42 ENGINEERING↗

Current measurement apparatus

Apparatus and methods are provided for a system for measurement of a current in a conductor such that the conductor current may be momentarily directed to a current measurement element in order to maintain proper current without significantly increasing an amount of power dissipation attributable to the current measurement element or adding resistance to assist in current measurement. The apparatus and methods described herein are useful in superconducting circuits where it is necessary to monitor current carried by the superconducting elements while minimizing the effects of power dissipation attributable to the current measurement element.

47 OTHER INSTRUMENTATION↗

Binary Pseudo-Random Gratings and Arrays for Calibration of Modulation Transfer Functions of Surface Profilometers

A technique for precise measurement of the modulation transfer function (MTF), suitable for characterization of a broad class of surface profilometers, is investigated in detail. The technique suggested in papers Yashchuk et al. (2007), Yashchuk et al. (2008) is based on use of binary pseudo-random (BPR) gratings and arrays as standard MTF test surfaces. Unlike most conventional test surfaces, BPR gratings and arrays possess white-noise-like inherent power spectral densities (PSD), allowing the direct determination of the one- and two-dimensional MTF, respectively, with a sensitivity uniform over the entire spatial frequency range of a profiler. In the cited work, a one-dimensional realization of the suggested method based on use of BPR gratings has been demonstrated. Here, a high performance of the MTF calibration technique is demonstrated via cross comparison measurements of a number of two-dimensional BPR arrays using two different interferometric microscopes and a scatterometer. We also present the results of application of the experimentally determined MTF correction to the measurement taken with the Micromap{trademark}-570 interferometric microscope of the surface roughness of a super-polished test mirror. In this particular case, without accounting for the instrumental MTF, the surface rms roughness over half of the instrumental spatial frequency bandwidth would be underestimated by a factor of approximately 1.4.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved test method to verify the power rating of a photovoltaic (PV) project.

This paper reviews the PVUSA power rating method and presents two additional methods that seek to improve this method in terms of model precision and increased seasonal applicability. It presents the results of an evaluation of each method based upon regression analysis of over 12 MW of operating photovoltaic (PV) systems located in a wide variety of climates. These systems include a variety of PV technologies, mounting configurations, and array sizes to ensure the conclusions are applicable to a wide range of PV designs and technologies. The work presented in this paper will be submitted to ASTM for use in the development of a standard test method for certifying the power rating of PV projects.

14 SOLAR ENERGY↗

Measuring strength at ultrahigh strain rates.

The strain rate sensitivity of materials is measured through a combination of quasistatic, Hopkinson bar, and pressure-shear experiments. The pressure-shear technique has largely been limited to strain rates of order 1E6 1/s. Recent advances in laser and magnetically driven ramp loading have made it possible to achieve significantly higher rates, 1E5-1E8 1/s, under uniaxial strain compression. Strength in these experiments can be calculated by comparing the loading response to the hydrostatic (pressure-density) response of the material for the same density and temperature [Fowles, 1961]. This must be done accounting for the heating due to plastic work in the experiments. Experimental uniaxial strain data for aluminum for strain rates up to 1E8 1/s are examined and compared with existing data. The results are consistent with conventional views of the strain rate sensitivity of aluminum. However, when one considers the higher mean stress (pressure) present in the uniaxial strain experiments and, to a lesser extent, the pressure-shear experiments, one finds the material remains rate insensitive to about 1E7 1/s, two orders of magnitude higher than previously thought. Important caveats about determining strength in this manner will be discussed, and recommendations for future work will be made.

36 MATERIALS SCIENCE↗