Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ML”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Rectal Dose-Volume Differences Using Proton Radiotherapy and a Rectal Balloon or Water Alone for the Treatment of Prostate Cancer

Purpose: To describe dose-volume values with the use of water alone vs. a rectal balloon (RB) for the treatment of prostate cancer with proton therapy. Materials and Methods: We analyzed 30 proton plans for 15 patients who underwent CT and MRI scans with an RB or water alone. Simulation was performed with a modified MRI endorectal coil and an RB with 100 mL of water or water alone. Doses of 78-82 gray equivalents were prescribed to the planning target volume. The two groups were compared for three structures: rectum, rectal wall (RW), and rectal wall 7 cm (RW7) at the level of the planning target volume. Results: Rectum and RW volumes radiated to low, intermediate, and high doses were small: rectum V10, 33.7%; V50, 17.3%; and V70, 10.2%; RW V10, 32.4%; V50, 20.4%; and V70, 14.6%. The RB effectively increased the rectal volume for all cases (139.8 {+-} 44.9 mL vs. 217.7 {+-} 32.2 mL (p < 0.001). The RB also decreased the volume of the rectum radiated to doses V10-V65 (p {<=} 0.05); RW for V10-V50; and RW7 for V10-V35. An absolute rectum V50 improvement >5% was seen for the RB in 5 of 15 cases, for a benefit of 9.2% {+-} 2.3% compared with 2.4% {+-} 1.3% for the remaining 10 cases (p < 0.001). Similar benefit was seen for the rectal wall. No benefit was seen for doses {>=}70 gray equivalents for the rectum, RW, or RW7. No benefit of {<=}1% was seen with an RB in 46% for the rectum V70 and in 40% for the rectal wall V70. Conclusions: Rectum and rectal wall doses with proton radiation were low whether using water or an RB. Selected patients will have a small but significant advantage with an RB; however, water alone was well tolerated and will be an alternative for most patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Determination of Respiratory Motion for Distal Esophagus Cancer Using Four-Dimensional Computed Tomography

Purpose: To investigate the motion characteristics of distal esophagus cancer primary tumors using four-dimensional computed tomography (4D CT). Methods and Materials: Thirty-one consecutive patients treated for esophagus cancer who received respiratory-gated 4D CT imaging for treatment planning were selected. Deformable image registration was used to map the full expiratory motion gross tumor volume (GTV) to the full-inspiratory CT image, allowing quantitative assessment of each voxel's displacement. These displacements were correlated with patient tumor and respiratory characteristics. Results: The mean (SE) tidal volume was 608 (73) mL. The mean GTV volume was 64.3 (10.7) mL on expiration and 64.1 (10.7) mL on inspiration (no significant difference). The mean tumor motion in the x-direction was 0.13 (0.006) cm (average of absolute values), in the y-direction 0.23 (0.01) cm (anteriorly), and in the z-direction 0.71 (0.02) cm (inferiorly). Tumor motion correlated with tidal volume. Comparison of tumor motion above vs. below the diaphragm was significant for the average net displacement (p = 0.014), motion below the diaphragm was greater than above. From the cumulative distribution 95% of the tumors moved less than 0.80 cm radially and 1.75 cm inferiorly. Conclusions: Primary esophagus tumor motion was evaluated with 4D CT. According to the results of this study, when 4D CT is not available, a radial margin of 0.8 cm and axial margin of {+-}1.8 cm would provide tumor motion coverage for 95% of the cases in our study population.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose Distribution in Bladder and Surrounding Normal Tissues in Relation to Bladder Volume in Conformal Radiotherapy for Bladder Cancer

Purpose: To estimate bladder movements and changes in dose distribution in the bladder and surrounding tissues associated with changes in bladder filling and to estimate the internal treatment margins. Methods and Materials: A total of 16 patients with bladder cancer underwent planning computed tomography scans with 80- and 150-mL bladder volumes. The bladder displacements associated with the change in volume were measured. Each patient had treatment plans constructed for a 'partially empty' (80 mL) and a 'partially full' (150 mL) bladder. An additional plan was constructed for tumor irradiation alone. A subsequent 9 patients underwent sequential weekly computed tomography scanning during radiotherapy to verify the bladder movements and estimate the internal margins. Results: Bladder movements were mainly observed cranially, and the estimated internal margins were nonuniform and largest (>2 cm) anteriorly and cranially. The dose distribution in the bladder worsened if the bladder increased in volume: 70% of patients (11 of 16) would have had bladder underdosed to <95% of the prescribed dose. The dose distribution in the rectum and intestines was better with a 'partially empty' bladder (volume that received >70%, 80%, and 90% of the prescribed dose was 23%, 20%, and 15% for the rectum and 162, 144, 123 cm{sup 3} for the intestines, respectively) than with a 'partially full' bladder (volume that received >70%, 80%, and 90% of the prescribed dose was 28%, 24%, and 18% for the rectum and 180, 158, 136 cm{sup 3} for the intestines, respectively). The change in bladder filling during RT was significant for the dose distribution in the intestines. Tumor irradiation alone was significantly better than whole bladder irradiation in terms of organ sparing. Conclusion: The displacements of the bladder due to volume changes were mainly related to the upper wall. The internal margins should be nonuniform, with the largest margins cranially and anteriorly. The changes in bladder filling during RT could influence the dose distribution in the bladder and intestines. The dose distribution in the rectum and bowel was slightly better with a 'partially empty' than with a 'full' bladder.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modeling Plan-Related Clinical Complications Using Machine Learning Tools in a Multiplan IMRT Framework

Purpose: To predict organ-at-risk (OAR) complications as a function of dose-volume (DV) constraint settings without explicit plan computation in a multiplan intensity-modulated radiotherapy (IMRT) framework. Methods and Materials: Several plans were generated by varying the DV constraints (input features) on the OARs (multiplan framework), and the DV levels achieved by the OARs in the plans (plan properties) were modeled as a function of the imposed DV constraint settings. OAR complications were then predicted for each of the plans by using the imposed DV constraints alone (features) or in combination with modeled DV levels (plan properties) as input to machine learning (ML) algorithms. These ML approaches were used to model two OAR complications after head-and-neck and prostate IMRT: xerostomia, and Grade 2 rectal bleeding. Two-fold cross-validation was used for model verification and mean errors are reported. Results: Errors for modeling the achieved DV values as a function of constraint settings were 0-6%. In the head-and-neck case, the mean absolute prediction error of the saliva flow rate normalized to the pretreatment saliva flow rate was 0.42% with a 95% confidence interval of (0.41-0.43%). In the prostate case, an average prediction accuracy of 97.04% with a 95% confidence interval of (96.67-97.41%) was achieved for Grade 2 rectal bleeding complications. Conclusions: ML can be used for predicting OAR complications during treatment planning allowing for alternative DV constraint settings to be assessed within the planning framework.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gamma Knife Radiosurgery for Benign Tumors With Symptoms From Brainstem Compression

Purpose: This study evaluated the role of radiosurgery in the management of symptomatic patients with brainstem compression from benign basal tumors. Methods and Materials: Over a 17-year, period 246 patients (202 vestibular schwannomas and 44 meningiomas) with brainstem compression from benign skull-base tumors were managed with Gamma Knife radiosurgery. Median tumor volumes were 3.9 cm{sup 3} (range, 0.8-39.0 mL) and 6.6 mL (range, 1.6-25.1 mL) for vestibular schwannomas and meningiomas, respectively. For both tumors, a median marginal dose of 13 Gy was prescribed. Median follow-up of patients was 65 months for vestibular schwannomas and 60 months for meningiomas. Patients were categorized into four groups on the basis of the tumor-brainstem relationship on neuroimaging. Results: Preservation of function was stratified according to grade of brainstem compression. We analyzed the effect of radiosurgery on symptoms of brainstem compression. The tumor control rate was 100 % for meningioma and 97% for vestibular schwannomas (although 5% required an additional procedure such as a ventriculoperitoneal shunt). In patients with vestibular schwannoma, serviceable hearing was preserved in 72.0%. Balance improved in 31.9%, remained unchanged in 56.5%, and deteriorated in 11.6% of patients who had imbalance at presentation. Balance improved significantly in patients who had less tumor compression (p = 0.0357) after radiosurgery. Symptoms improved in 43.2% of patients with meningioma. Conclusion: Radiosurgery is a minimally invasive option for patients with benign basal tumors that indent or distort the brainstem. A high tumor growth control rate and satisfactory rate of neurological preservation and symptom control can be obtained with radiosurgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improving the Definition of Tumor Bed Boost With the Use of Surgical Clips and Image Registration in Breast Cancer Patients

Purpose: To evaluate the accuracy of a boost technique. Methods and Materials: Twenty-two patients underwent tumorectomy with placement of two or more clips in the surgical cavity before breast remodeling. Preoperative and postoperative computed tomography scans, with match-point registration, were performed on all patients. The relationship between the location of the gross tumor volume (GTV), defined on the preoperative scan, and clip clinical target volume (CTV) (clips with a 5-mm margin on the postoperative scan) was then studied, by use of commercial volume analysis software. Results: Of the patients, 4 had two clips, 2 had three clips, 8 had four clips, and 8 had five clips. The median GTV was 1.06 mL (range, 0.2-5.3 mL); clip CTV ranged from 2.4 to 21.5 mL. Volumetric analysis showed that in 7 cases (32%), there was no intersection between the GTV and the clip CTV, with the following distribution: 4 patients with two clips, 1 patient with three clips, 1 patient with four clips, and 1 patient with five clips. The common contoured volume was defined as the percent ratio between the intersection of the GTV and clip CTV and the GTV. It was found to be significantly increased if three or more clips were used vs. only two clips (common contoured volume, 35.45% vs. 0.73%; p = 0.028). Finally, the GTV and clip CTV volume relationship can be presented as follows: 12.5% to 33% overlap in 8 patients (36.4%), 50% to 75% in 5 patients (22.7%), and greater than 90% in 2 patients (9%). Conclusions: The use of three or more clips during tumorectomy increases the accuracy of tumor bed delineation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Novel Assessment of Renal Motion in Children as Measured via Four-Dimensional Computed Tomography

Objectives: Abdominal intensity-modulated radiation therapy and proton therapy require quantification of target and organ motion to optimize localization and treatment. Although addressed in adults, there is no available literature on this issue in pediatric patients. We assessed physiologic renal motion in pediatric patients. Methods and Materials: Twenty free-breathing pediatric patients at a median age of 8 years (range, 2-18 years) with intra-abdominal tumors underwent computed tomography simulation and four-dimensional computed tomography acquisition (slice thickness, 3 mm). Kidneys and diaphragms were contoured during eight phases of respiration to estimate center-of-mass motion. We quantified center of kidney mass mobility vectors in three dimensions: anteroposterior (AP), mediolateral (ML), and superoinferior (SI). Results: Kidney motion decreases linearly with decreasing age and height. The 95% confidence interval for the averaged minima and maxima of renal motion in children younger than 9 years was 5-9 mm in the ML direction, 4-11 mm in the AP direction, and 12-25 mm in the SI dimension for both kidneys. In children older than 9 years, the same confidence interval reveals a widening range of motion that was 5-16 mm in the ML direction, 6-17 mm in the AP direction, and 21-52 mm in the SI direction. Although not statistically significant, renal motion correlated with diaphragm motion in older patients. The correlation between diaphragm motion and body mass index was borderline (r = 0.52, p = 0.0816) in younger patients. Conclusions: Renal motion is age and height dependent. Measuring diaphragmatic motion alone does not reliably quantify pediatric renal motion. Renal motion in young children ranges from 5 to 25 mm in orientation-specific directions. The vectors of motion range from 5 to 52 mm in older children. These preliminary data represent novel analyses of pediatric intra-abdominal organ motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A New Brain Positron Emission Tomography Scanner With Semiconductor Detectors for Target Volume Delineation and Radiotherapy Treatment Planning in Patients With Nasopharyngeal Carcinoma

Purpose: We compared two treatment planning methods for stereotactic boost for treating nasopharyngeal carcinoma (NPC): the use of conventional whole-body bismuth germanate (BGO) scintillator positron emission tomography (PET{sub CONV}WB) versus the new brain (BR) PET system using semiconductor detectors (PET{sub NEW}BR). Methods and Materials: Twelve patients with NPC were enrolled in this study. [{sup 18}F]Fluorodeoxyglucose-PET images were acquired using both the PET{sub NEW}BR and the PET{sub CONV}WB system on the same day. Computed tomography (CT) and two PET data sets were transferred to a treatment planning system, and the PET{sub CONV}WB and PET{sub NEW}BR images were coregistered with the same set of CT images. Window width and level values for all PET images were fixed at 3000 and 300, respectively. The gross tumor volume (GTV) was visually delineated on PET images by using either PET{sub CONV}WB (GTV{sub CONV}) images or PET{sub NEW}BR (GTV{sub NEW}) images. Assuming a stereotactic radiotherapy boost of 7 ports, the prescribed dose delivered to 95% of the planning target volume (PTV) was set to 2000 cGy in 4 fractions. Results: The average absolute volume ({+-}standard deviation [SD]) of GTV{sub NEW} was 15.7 ml ({+-}9.9) ml, and that of GTV{sub CONV} was 34.0 ({+-}20.5) ml. The average GTV{sub NEW} was significantly smaller than that of GTV{sub CONV} (p = 0.0006). There was no statistically significant difference between the maximum dose (p = 0.0585) and the mean dose (p = 0.2748) of PTV. The radiotherapy treatment plan based on the new gross tumor volume (PLAN{sub NEW}) significantly reduced maximum doses to the cerebrum and cerebellum (p = 0.0418) and to brain stem (p = 0.0041). Conclusion: Results of the present study suggest that the new brain PET system using semiconductor detectors can provide more accurate tumor delineation than the conventional whole-body BGO PET system and may be an important tool for functional and molecular radiotherapy treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Tumor Shape Variability in Head-and-Neck Cancer Patients Over the Course of Radiation Therapy Using Implanted Gold Markers

Purpose: This study quantifies tumor shape variability in head-and-neck cancer patients during radiation therapy using implanted markers. Methods and Materials: Twenty-seven patients with oropharyngeal tumors treated with (chemo)radiation were included. Helical gold markers (0.35 Multiplication-Sign 2 mm, 3-10/patient, average 6) were implanted around the tumor. Markers were identified on planning computed tomography (CT) and daily cone beam CT (CBCT). After bony anatomy registration, the daily vector length on CBCT in reference to the planning CT and daily marker movement perpendicular to the gross tumor volume (GTV) surface at planning CT (d{sub normal}) of each marker were analyzed. Time trends were assessed with linear regression of the {sub markers}. In 2 patients, 2 markers were implanted in normal tissue to evaluate migration by measuring intermarker distances. Results: Marker implantation was feasible without complications. Three-dimensional vectors (4827 measurements, mean 0.23 cm, interquartile ratio 0.24 cm) were highest in base of tongue sublocalization (P<.001) and bulky tumors (vectors exceeded 0.5 cm in 5.7% [0-20 mL], 12.0% [21-40 mL], and 21.7% [{>=}41 mL], respectively [P<.001] of measurements). The measured inward time trend in 11/27 patients correlated with the visual observed marker pattern. In patients with an outward trend (5/27) or no trend (11/27), visual observation showed predominantly an inhomogeneous pattern. Remarkably, in 6 patients, outward marker movement was observed in the posterior pharyngeal wall. The difference in distance between normal tissue markers (1 SD) was 0.05-0.06 cm without time trend, indicating that implanted markers did not migrate. Conclusions: During head-and-neck radiation therapy, normal tissue markers remained stable. Changes in position of tumor markers depended on sublocalization and tumor volume. Large differences in marker patterns between patients as well as within patients were observed. Based on our study, the cranial and caudal border in the posterior pharyngeal wall are at highest risk to be covered insufficiently. Furthermore, implanted markers could help identify patients with an actual shrinkage of the GTV who might benefit from mid-radiation therapy redelineation to reduce toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessment of Interfraction Patient Setup for Head-and-Neck Cancer Intensity Modulated Radiation Therapy Using Multiple Computed Tomography-Based Image Guidance

Purpose: Various image guidance systems are commonly used in conjunction with intensity modulated radiation therapy (IMRT) in head-and-neck cancer irradiation. The purpose of this study was to assess interfraction patient setup variations for 3 computed tomography (CT)-based on-board image guided radiation therapy (IGRT) modalities. Methods and Materials: A total of 3302 CT scans for 117 patients, including 53 patients receiving megavoltage cone-beam CT (MVCBCT), 29 receiving kilovoltage cone-beam CT (KVCBCT), and 35 receiving megavoltage fan-beam CT (MVFBCT), were retrospectively analyzed. The daily variations in the mediolateral (ML), craniocaudal (CC), and anteroposterior (AP) dimensions were measured. The clinical target volume-to-planned target volume (CTV-to-PTV) margins were calculated using 2.5Σ + 0.7 σ, where Σ and σ were systematic and random positioning errors, respectively. Various patient characteristics for the MVCBCT group, including weight, weight loss, tumor location, and initial body mass index, were analyzed to determine their possible correlation with daily patient setup. Results: The average interfraction displacements (± standard deviation) in the ML, CC, and AP directions were 0.5 ± 1.5, −0.3 ± 2.0, and 0.3 ± 1.7 mm (KVCBCT); 0.2 ± 1.9, −0.2 ± 2.4, and 0.0 ± 1.7 mm (MVFBCT); and 0.0 ± 1.8, 0.5 ± 1.7, and 0.8 ± 3.0 mm (MVCBCT). The day-to-day random errors for KVCBCT, MVFBCT, and MVCBCT were 1.4-1.6, 1.7, and 2.0-2.1 mm. The interobserver variations were 0.8, 1.1, and 0.7 mm (MVCBCT); 0.5, 0.4, and 0.8 mm (MVFBCT); and 0.5, 0.4, and 0.6 mm (KVCBCT) in the ML, CC, and AP directions, respectively. The maximal calculated uniform CTV-to-PTV margins were 5.6, 6.9, and 8.9 mm for KVCBCT, MVFBCT, and MVCBCT, respectively. For the evaluated patient characteristics, the calculated margins for different patient parameters appeared to differ; analysis of variance (ANOVA) and/or t test analysis found no statistically significant setup difference in any direction. Conclusions: Daily random setup errors and CTV-to-PTV margins for treatment of head-and-neck cancer were affected by imaging quality. Our data indicated that larger margins were associated with MVFBCT and MVCBCT, compared with smaller margins for KVCBCT. IGRT modalities with better image quality are encouraged in clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Local and Global Function Model of the Liver

Purpose: To develop a local and global function model in the liver based on regional and organ function measurements to support individualized adaptive radiation therapy (RT). Methods and Materials: A local and global model for liver function was developed to include both functional volume and the effect of functional variation of subunits. Adopting the assumption of parallel architecture in the liver, the global function was composed of a sum of local function probabilities of subunits, varying between 0 and 1. The model was fit to 59 datasets of liver regional and organ function measures from 23 patients obtained before, during, and 1 month after RT. The local function probabilities of subunits were modeled by a sigmoid function in relating to MRI-derived portal venous perfusion values. The global function was fitted to a logarithm of an indocyanine green retention rate at 15 minutes (an overall liver function measure). Cross-validation was performed by leave-m-out tests. The model was further evaluated by fitting to the data divided according to whether the patients had hepatocellular carcinoma (HCC) or not. Results: The liver function model showed that (1) a perfusion value of 68.6 mL/(100 g · min) yielded a local function probability of 0.5; (2) the probability reached 0.9 at a perfusion value of 98 mL/(100 g · min); and (3) at a probability of 0.03 [corresponding perfusion of 38 mL/(100 g · min)] or lower, the contribution to global function was lost. Cross-validations showed that the model parameters were stable. The model fitted to the data from the patients with HCC indicated that the same amount of portal venous perfusion was translated into less local function probability than in the patients with non-HCC tumors. Conclusions: The developed liver function model could provide a means to better assess individual and regional dose-responses of hepatic functions, and provide guidance for individualized treatment planning of RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Machine learning guided search for energetically favorable metal borocarbide ternary compounds

In this work, we employ machine-learning (ML) combined with first principles calculations to efficiently search for the energetically favorable metal borocarbide (M-B-C) ternary compounds with M being the group 1–3 metal elements. Using a crystal graph convolutional neural network (CGCNN) ML approach followed by first-principles calculations, we predicted 47 energetically favorable stable and metastable ternary Na-B-C, Ca-B-C, and La-B-C ternary compounds with their decomposition energy (E d ) below or within 100 meV/atom from the currently known convex hulls. Phonon spectra and electronic structures of the 14 energetically favorable stable structures are also investigated by first-principles calculations. By substituting the metal atoms in the 29 energetically favorable non-equivalent template structures of Na (Ca, La)-B-C with other group 1–3 elements in the periodic table, we further obtain 22 stable structures and 52 metastable structures (E d ≤100 meV/atom with respect to the known convex hulls) for Li-B-C, K-B-C, Rb-B-C, Mg-B-C, Sr-B-C, Ba-B-C, Sc-B-C and Y-B-C ternary compounds. New convex hulls including our newly predicted stable ternary structures and the known stable structures are constructed for the M-B-C systems. The results obtained by our ML guided first-principles calculations enrich our knowledge in the structure and energy landscape of metal borocarbide ternary compounds and provide useful guidance for further experimental synthesis and discovery.

36 MATERIALS SCIENCE↗

Rapid Coal-Ash Characterization using Geophysical Methods & Machine Learning

Coal combustion products (CCP) are challenging to delineate in heterogeneous field settings. Conventional methods (test pits, coring, and laboratory analyses) are labor-intensive, slow, invasive, and provide sparse spatial coverage. This study evaluates whether rapid non-invasive geophysical screening methods—induced polarization (IP), magnetic susceptibility, and nuclear magnetic resonance (NMR) —combined with surface colorimetry (RGB_24), can discriminate CCP-soil mixtures and provide reliable estimates of CCP content. Laboratory measurements were collected on five CCP-soil mixtures (series) and modeled using (i) a linear baseline, (ii) a calibrated non-linear (power-mean) model, and (iii) a machine-learning (ML) Random Forest approach, with validation via leave-one-series-out and site-specific tests. Across the five series, individual signals—particularly IP and magnetic susceptibility—were strongly predictive of ash content but were consistently outperformed by combined models. The pooled calibrated non-linear and ML models captured the observed non-linearity and achieved high accuracy and precision, improving on linear fits. Colorimetry showed the weakest direct relationship with ash content for the tested samples but improved performance when included in multi-signal models. At pre-selected 3.5% decision threshold, calibrated and ML approaches yielded near-perfect classification (Matthews correlation coefficient ˜ 1), suggesting strong practical operability for field screening. Additionally, field-analog tests highlighted the role of endmembers—accuracy declined without access to end-member measurements but was largely recovered by collecting a minimal labeled pair for local recalibration. With end members, accuracy remained high. Globally trained models performed well on three operational unknowns; however, series-specific refits provided the most accurate predictions. Overall, these results highlight the potential of combining rapid geophysics and minimal local calibration for improved coal-ash delineation.

Peshtani, Klaudio↗

A comparative study of machine learning models for predicting the state of reactive mixing

Mixing phenomena are important mechanisms controlling flow, species transport, and reaction processes in fluids and porous media. Accurate predictions of reactive mixing are critical for many Earth and environmental science problems such as contaminant fate and remediation, macroalgae growth, and plankton biomass evolution. Here, to investigate the evolution of mixing dynamics under different scenarios (e.g., anisotropy, fluctuating velocity fields), a finite-element-based numerical model was built to solve the fast, irreversible bimolecular reaction-diffusion equations to simulate a range of reactive-mixing scenarios. A total of 2,315 simulations were performed using different sets of model input parameters comprising various spatial scales of vortex structures in the velocity field, time-scales associated with velocity oscillations, the perturbation parameter for the vortex-based velocity, anisotropic dispersion contrast (i.e., ratio of longitudinal-to-transverse dispersion), and molecular diffusion. The outputs comprised concentration profiles of reactants and products. The inputs to and outputs from these simulations were concatenated into feature and label matrices, respectively, to train 20 different machine learning (ML) models intended to emulate system behavior. These 20 ML emulators, based on linear methods, Bayesian methods, ensemble learning methods, and multilayer perceptrons (MLPs), were trained to classify the state of mixing and predict three quantities of interest (QoIs) characterizing species production, decay (i.e., average concentration, square of average concentration), and degree of mixing (i.e., variances of species concentration). Unsurprisingly, linear classifiers and regressors failed to reproduce the QoIs; however, ensemble methods (classifiers and regressors) and the MLP model accurately classified the state of reactive mixing and the QoIs. Among ensemble methods, random forest and decision-tree-based AdaBoost faithfully predicted the QoIs. At run time, trained ML emulators produced results times faster than the finite-element simulations. Due to their low computational expense and high accuracy, ensemble and MLP models are excellent emulators for these numerical simulations and great utilities in uncertainty quantification exercises, which can require 1,000s of forward model runs.

97 MATHEMATICS AND COMPUTING↗

Machine learning models for estimating contamination across different curbside collection strategies

Contaminated recyclables, which are frequently discarded as waste, pose a significant challenge to the implementation of a circular economy. These contaminated recyclables impede the circulation of resources, resulting in higher processing costs at material recovery facilities (MRFs). Over the past few decades, machine learning (ML) models such as linear regression (LR), support vector machine (SVM), and random forest (RF) have evolved to provide new methods for predicting inbound contamination rates in addition to traditional statistical models. In this study, we applied ML models to predict inbound contamination rates using demographic features from 15 counties in the U.S. with different curbside collection strategies. In general, we found that ML models outperformed linear mixed models. Specifically, SVM models had the highest performance (R 2 = 0.75; mean absolute error (MAE) = 0.06), which may be due to their ability to model nonlinear relationships between features and inbound contamination rates. Further, the key predictor was population, with poverty rate being positively correlated and median age negatively correlated with inbound contamination rates. To improve the management of contamination and enhance the implementation of a circular economy, better models are needed to understand and estimate inbound contamination rates as well as identify critical factors in the present and future.

54 ENVIRONMENTAL SCIENCES↗

The impact of tritium phytoremediation on plant health as measured by fluorescence

Phytoremediation, using plants for soil, sediment, or water contaminant clean-up, is an established technology dependent on plant health. Tritium (3H), a radioactive isotope of hydrogen that is generally found in the environment as tritiated water (HTO), is a low-level beta emitter with a half-life of 12.32 years. Chlorophyll fluorescence (CF) for monitoring risk assessment of tritium to plant health was conducted at the Tritium Irrigation Facility (TIF) located on the US Department of Energy's Savannah River Site (SRS) near Aiken, SC. Two fluorometers were evaluated in conjunction with phytoremediation at the 25 –acre TIF where tritiated groundwater is being spray–irrigated on a mixed coniferous/deciduous forested watershed as a means of reducing tritium release to a nearby stream that serves as a tributary to the Savannah River. Tritium activity in irrigated water averaged 104 + 42 pCi mL -1 during the 2003 project. Fluorescence parameters measured by the two fluorometers were well correlated with each other (p < 0.0001). Tritium in water respired from oak leaves ranged up to 1845.13 pCi ml -1 and 2138.22 pCi ml -1 in pine needles. Trees in both the test and control sites were approximately 15 years old. In this report we demonstrated that fluorescence parameters provide an effective way to estimate the impact of HTO on plant health in a noninvasive, extremely rapid, and cost-effective manner. In the current study applying fluorometry, plants within the TIF phytoremediation site exposed to the site tritiated water were not significantly impacted by the tritium phytoremediation based on CF parameters as compared to the control, a nascent non-irrigated site.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Comparison of permeability predictions on cemented sandstones with physics-based and machine learning approaches

Permeability prediction has been an important problem since the time of Darcy. Most approaches to solve this problem have used either idealized physical models or empirical relations. In recent years, machine learning (ML) has led to more accurate and robust, but less interpretable empirical models. Using 211 core samples collected from 12 wells in the Garn Sandstone from the North Sea, this study compared idealized physical models based on the Carman-Kozeny equation to interpretable ML models. We found that ML models trained on estimates of physical properties are more accurate than physical models. The results show evidence of a threshold of about 10% volume fraction, above which pore-filling cement strongly affects permeability.

03 NATURAL GAS↗

Feature engineering for machine learning enabled early prediction of battery lifetime

Accurate battery lifetime estimates enable accelerated design of novel battery materials and determination of optimal use protocols for longevity in deployments. Unfortunately, traditional battery testing may take years to reach thousands of cycles. Recent studies have shown that machine learning (ML) tools can predict lithium-ion battery lifetimes from 100 or fewer preliminary cycles, representing only a few weeks of cycling. Until now, conclusions about the efficacy and broad applicability of these predictions across a variety of cathode chemistries have been limited by available experimental information. In this work, we leverage a battery cycling dataset representing six cathode chemistries (NMC111, NMC532, NMC622, NMC811, HE5050, and 5Vspinel), multiple electrolyte/anode compositions, and 300 total carefully prepared pouch batteries to explore feature selection and battery chemistry's role in ML battery lifetime predictions. Here, a mean absolute error (MAE) of 78 cycles in prediction was seen for a chemistry-spanning test set from 100 preliminary cycles. Furthermore, an MAE of 103 cycles was seen when using only the first cycle. This study represents an in-depth investigation of strategies for feature selection for battery lifetime prediction, ML models' generalization across multiple battery chemistries, and predictions beyond the training set in the chemical space.

25 ENERGY STORAGE↗