Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETOMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Exchange bias in La 0.7 Sr 0.3 CrO 3 /La 0.7 Sr 0.3 MnO 3 /La 0.7 Sr 0.3 CrO 3 heterostructures

In the recent past, heterostructures of magnetic oxide thin films have attracted a great deal of research excitement due to very interesting physical properties such as antiferromagnetic interlayer coupling, tunable exchange-bias, interfacial driven magnetic properties and high mobility electron gas across the interfaces. In this work, we report on the comprehensive magnetic properties observed from the heterostructures of (2 unit cells) La 0.7 Sr 0.3 CrO 3 /(8 unit cells) La 0.7 Sr 0.3 MnO 3 /(2 unit cells) La 0.7 Sr 0.3 CrO 3 , which are epitaxially deposited on SrTiO 3 substrate by plasma-assisted oxide molecular beam epitaxy. Using SQUID magnetometer, the magnetic properties are studied when the magnetic field was applied both in plane and out of plane. The Curie temperature of this structure is found to be at 290 K. Most significantly, at 2 K, we observed a complete up/down shift (along magnetization axis) of hysteresis loop when the sample was cooled under a magnetic field of ± 5000 Oe in the in-plane configuration. We believe that the strong antiferromagnetic (super) exchange coupling of Mn-Cr across the two interfaces is responsible for the observed exchange bias. We will present and discuss our in-detailed experimental findings collected on this heterostructure as a function of temperature and magnetic field.

36 MATERIALS SCIENCE↗

Magnetic field sensors for detection of trapped flux in superconducting radio frequency cavities

Superconducting radio-frequency (SRF) cavities are fundamental building block of modern particle accelerators. They operate at liquid helium temperatures 2-4 K to achieve very high quality factors 1e10-1e11. Trapping of magnetic flux within the superconductor is a significant contribution to the residual RF losses which limit the achievable quality factor. Suitable diagnostic tools are in high demand to understand the mechanisms of flux trapping in technical superconductors and the fundamental components of such diagnostic tool are magnetic field sensors. We have studied the performance of commercially available Hall probes, anisotropic magnetoresistive sensors and flux-gate magnetometers with respect to their sensitivity and capability to detect localized, low magnetic flux amplitudes, of the order of few tens of magnetic flux quantum at liquid helium temperature. Although Hall probes have the lowest magnetic field sensitivity (~96$ nV$/microT at 2 K), their physical dimensions are such that they have the ability to detect the lowest number of trapped vortices among the three type of sensors. Hall probes and anisotropic magnetoresistive sensors have been selected to be used in a setup to map regions of trapped flux on the surface of a single-cell SRF cavity.

47 OTHER INSTRUMENTATION↗

Molecular qubits based on photogenerated spin-correlated radical pairs for quantum sensing

Photogenerated spin-correlated radical pairs (SCRPs) in electron donor–bridge–acceptor (D–B–A) molecules can act as molecular qubits and inherently spin qubit pairs. SCRPs can take singlet and triplet spin states, comprising the quantum superposition state. Their synthetic accessibility and well-defined structures, together with their ability to be prepared in an initially pure, entangled spin state and optical addressability, make them one of the promising avenues for advancing quantum information science. Coherence between two spin states and spin selective electron transfer reactions form the foundation of using SCRPs as qubits for sensing. We can exploit the unique sensitivity of the spin dynamics of SCRPs to external magnetic fields for sensing applications including resolution-enhanced imaging, magnetometers, and magnetic switch. Molecular quantum sensors, if realized, can provide new technological developments beyond what is possible with classical counterparts. While the community of spin chemistry has actively investigated magnetic field effects on chemical reactions via SCRPs for several decades, we have not yet fully exploited the synthetic tunability of molecular systems to our advantage. This review offers an introduction to the photogenerated SCRPs-based molecular qubits for quantum sensing, aiming to lay the foundation for researchers new to the field and provide a basic reference for researchers active in the field. We focus on the basic principles necessary to construct molecular qubits based on SCRPs and the examples in quantum sensing explored to date from the perspective of the experimentalist.

Mani, Tomoyasu (ORCID:0000000241255195)↗

Magnetic functionalization and catalytic behavior of magnetic nanoparticles during laser photochemical graphitization of polyimide

We report laser-assisted photochemical graphitization of polyimides (PIs) into functional magnetic nanocomposites using laser irradiation of PI in the presence of magnetite nanoparticles (MNPs). PI Kapton sheets covered with MNP were photochemically treated under ambient conditions using a picosecond pulsed laser (1064 nm) to obtain an electrically conductive material. Scanning electron microscopy of the treated material revealed a layered magnetic nanoparticle/graphite (MNP/graphite) nanocomposite structure. Four probe conductivity measurements indicated that the nanocomposite has an electrical conductivity of 1550 ± 60 S/m. Superconducting quantum interference device magnetometer-based magnetic characterization of the treated material revealed an anisotropic ferromagnetic response in the MNP/graphite nanocomposite compared to the isotropic response of MNP. Raman spectroscopy of the MNP/graphite nanocomposite revealed a fourfold improvement in graphitization, suppression in disorder, and decreased nitrogenous impurities compared to the graphitic material obtained from laser treatment of just PI sheets. X-ray photoelectron spectroscopy, x-ray diffraction, and energy-dispersive x-ray spectroscopy were used to delineate the phase transformations of MNP during the formation of MNP/graphite nanocomposite. Post-mortem characterization indicates a possible photocatalytic effect of MNP during MNP/graphite nanocomposite formation. Under laser irradiation, MNP transformed from the initial Fe 3 O 4 phase to γ-Fe 2 O 3 and Fe 5 C 2 phases and acted as nucleation spots to catalyze the graphitization process of PI.

36 MATERIALS SCIENCE↗

Magnetic force microscopy revealing long-range room temperature stable molecule bridge-induced magnetic ordering on magnetic tunnel junction (MTJ) pillars

Magnetic tunnel junctions (MTJs) can integrate novel single molecular device elements to overcome long-standing fabrication challenges, thus unlocking their novel potential. This study employs magnetic force microscopy (MFM) to demonstrate that organometallic molecules, when placed between two ferromagnetic electrodes along cross-junction shaped MTJ edges, dramatically altered the magnetic properties of the electrodes, affecting areas several hundred microns in size around the molecular junction vicinity at room temperature. These findings are supported by magnetic resonance and magnetometer studies on ∼7000 MTJ pillars. MFM on the pillar sample showed an almost complete disappearance of the magnetic contrast. The spatial magnetic image suggests that molecular channels significantly impacted the spin density of states in the ferromagnetic electrodes. This advancement in MTJ-based molecular devices paves the way for a new generation of commercially viable logic and memory devices controlled by molecular quantum states at near-room temperatures.

Tyagi, Pawan (ORCID:0000000275411344)↗

A magnon scattering platform

Significance This work describes a general scattering platform that uses magnons to explore the underlying properties of target materials. In this work we show how both phase and amplitude of magnons can be imaged using a nitrogen vacancy center magnetometer and how the scattered pattern of waves can be used to infer geometric and magnetic properties of a target material. To demonstrate this new experimental methodology we use a permalloy disk as our target and show that even with such a simple target unexpected behavior is observed. In addition, we provide a theoretical framework to reconstruct the properties of the target.

36 MATERIALS SCIENCE↗

STATISTICAL STUDY OF STRONG AND EXTREME GEOMAGNETIC DISTURBANCES AND SOLAR CYCLE CHARACTERISTICS

We study the relation between strong and extreme geomagnetic storms and solar cycle characteristics. The analysis uses an extensive geomagnetic index AA data set spanning over 150 yr complemented by the Kakioka magnetometer recordings. We apply Pearson correlation statistics and estimate the significance of the correlation with a bootstrapping technique. We show that the correlation between the storm occurrence and the strength of the solar cycle decreases from a clear positive correlation with increasing storm magnitude toward a negligible relationship. Hence, the quieter Sun can also launch superstorms that may lead to significant societal and economic impact. Our results show that while weaker storms occur most frequently in the declining phase, the stronger storms have the tendency to occur near solar maximum. Our analysis suggests that the most extreme solar eruptions do not have a direct connection between the solar large-scale dynamo-generated magnetic field, but are rather associated with smaller-scale dynamo and resulting turbulent magnetic fields. The phase distributions of sunspots and storms becoming increasingly in phase with increasing storm strength, on the other hand, may indicate that the extreme storms are related to the toroidal component of the solar large-scale field.

79 ASTRONOMY AND ASTROPHYSICS↗

Layer-by-layer assembly of a [Fe-(pyrazine){Pd(CN) 4 }] spin crossover thin film

Abstract [Fe-(pyrazine){Pd(CN) 4 }] (pyrazine = pz) thin films were fabricated using a layer-by-layer assembly approach, a method known to be tunable, versatile, and scalable, since thin films are better-suited for industrial applications. In this study, [Fe-(pz){Pd(CN) 4 }] powder was synthesized, and the results obtained from a vibrating sample magnetometer verified the presence of an abrupt hysteresis loop with widths of 45 K centered around 300 K, indicating good cooperativity. Super conducting quantum interference device magnetometry results indicated a slow spin transition with temperature but with evidence of hysteresis for thin film samples. X-ray absorption analysis provided further support of the spin crossover behavior but differs from the magnetometry because the spin state transition at the surface differs from the bulk of the thin film. X-ray photoelectron spectroscopy provided some insight into issues with the film deposition process and multiplex fitting was used to further support the claim that the surface of the film is different than the bulk of the film.

McElveen, Kayleigh A. (ORCID:0000000210302913)↗

Effects of head modeling errors on the spatial frequency representation of MEG

Abstract Objectives. We aim to investigate the effects of head model inaccuracies on signal and source reconstruction accuracies for various sensor array distances to the head. This allows for the assessment of the importance of head modeling for next-generation magnetoencephalography (MEG) sensors, optically-pumped magnetometers (OPM). Approach. A 1-shell boundary element method (BEM) spherical head model with 642 vertices of radius 9 cm and conductivity of 0.33 S m −1 was defined. The vertices were then randomly perturbed radially up to 2%, 4%, 6%, 8% and 10% of the radius. For each head perturbation case, the forward signal was calculated for dipolar sources located at 2 cm, 4 cm, 6 cm and 8 cm from the origin (center of the sphere), and for a 324 sensor array located at 10 cm to 15 cm from the origin. Equivalent current dipole (ECD) source localization was performed for each of these forward signals. The signal for each perturbed spherical head case was then analyzed in the spatial frequency domain, and the signal and ECD errors were quantified relative to the unperturbed case. Main results. In the noiseless and high signal-to-noise ratio (SNR) case of approximately ≥6 dB, inaccuracies in our spherical BEM head conductor models lead to increased signal and ECD inaccuracies when sensor arrays are placed closer to the head. This is true especially in the case of deep and superficial sources. In the noisy case however, the higher SNR for closer sensor arrays allows for an improved ECD fit and outweighs the effects of head geometry inaccuracies. Significance. OPMs may be placed directly on the head, as opposed to the more commonly used superconducting quantum interference device sensors which must be placed a few centimeters away from the head. OPMs thus allow for signals of higher spatial resolution to be captured, resulting in potentially more accurate source localizations. Our results suggest that an increased emphasis on accurate head modeling for OPMs may be necessary to fully realize its improved source localization potential.

Yeo, Wan-Jin (ORCID:0000000241417123)↗

Magnetic state switching in FeGa microstructures

This work demonstrates that magnetoelectric composite heterostructures can be designed at the length scale of 10µms that can be switched from a magnetized state to a vortex state, effectively switching the magnetization off, using electric field induced strain. This was accomplished using thin film magnetoelectric heterostructures of Fe 81.4 Ga 18.6 on a single crystal (011) [Pb(Mg 1/3 Nb 2/3 )O 3 ] 0.68 -[PbTiO 3 ] 0.32 (PMN-32PT) ferroelectric substrate. Here, the heterostructures were tripped from a multi-domain magnetized state to a flux closure vortex state using voltage induced strain in a piezoelectric substrate. FeGa heterostructures were deposited on a Si-substrate for superconducting quantum interference device magnetometry characterization of the magnetic properties. The magnetoelectric coupling of a FeGa continuous film on PMN-32PT was characterized using a magneto optical Kerr effect magnetometer with bi-axial strain gauges, and magnetic multi-domain heterostructures were imaged using x-ray magnetic circular dichroism—photoemission electron microscopy during the transition to the vortex state. The domain structures were modelled using MuMax 3 , a micromagnetics code, and compared with observations. The results provide considerable insight into designing magnetoelectric heterostructures that can be switched from an ‘on’ state to an ‘off’ state using electric field induced strain.

36 MATERIALS SCIENCE↗

Significant reduction in the low-field magnetization of Nb 3 Sn superconducting strands using the internal oxidation APC approach

Nb 3 Sn superconductors are promising for building accelerator magnets for future energy-frontier circular colliders. A critical factor for this application is the low-field persistent-current magnetization because it leads to several critical issues: e.g. low-field instability (including flux jumps), hysteresis loss, and field errors in magnet bores. Suppression of low-field magnetization requires reduction of low-field critical current density (J c ) or effective subelement size (d eff ). However, reduction of deff of state-of-the-art Nb 3 Sn conductors—the restacked-rod-process (RRP ® ) type—below 40–50 μm without a pronounced decrease in high-field J c is difficult. On the other hand, the internal oxidation method which forms artificial pinning centers (APC) in Nb 3 Sn offers an alternative approach to reducing the low-field magnetization. Compared with a conventional Nb 3 Sn conductor whose flux pinning force versus field (F p –B) curve peaks at ~20% of its irreversibility field (B irr ), the F p –B curve peaks of APC conductors shift to higher fields due to the point pinning effect, leading to flattening of the J c –B curves. The goal of this paper is to quantitatively study how much the APC approach can reduce the low-field magnetization. Here we measured the J c –B curves of an RRP ® conductor and two APC conductors (reacted at 700 °C) from zero field to B irr using a high-field vibrating sample magnetometer. Here the results showed that the APC conductors have higher non-Cu J c at high fields (e.g. 32%–41% higher at 16 T) and simultaneously lower non-Cu Jc at low fields (e.g. 28%–34% lower at 1 T) compared with the RRP ® . This effect is due to a competition between their Nb3Sn layer fraction ratios and layer F p ratios. Suppose they reach the same 16 T non-Cu J c , then the 1 T non-Cu J c and magnetization of the APC conductors are only half or even less compared with the RRP ® conductor.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Single-trial classification of evoked responses to auditory tones using OPM- and SQUID-MEG

Abstract Objective. Optically pumped magnetometers (OPMs) are emerging as a near-room-temperature alternative to superconducting quantum interference devices (SQUIDs) for magnetoencephalography (MEG). In contrast to SQUIDs, OPMs can be placed in a close proximity to subject’s scalp potentially increasing the signal-to-noise ratio and spatial resolution of MEG. However, experimental demonstrations of these suggested benefits are still scarce. Here, to compare a 24-channel OPM-MEG system to a commercial whole-head SQUID system in a data-driven way, we quantified their performance in classifying single-trial evoked responses. Approach. We measured evoked responses to three auditory tones in six participants using both OPM- and SQUID-MEG systems. We performed pairwise temporal classification of the single-trial responses with linear discriminant analysis as well as multiclass classification with both EEGNet convolutional neural network and xDAWN decoding. Main results. OPMs provided higher classification accuracies than SQUIDs having a similar coverage of the left hemisphere of the participant. However, the SQUID sensors covering the whole helmet had classification scores larger than those of OPMs for two of the tone pairs, demonstrating the benefits of a whole-head measurement. Significance. The results demonstrate that the current OPM-MEG system provides high-quality data about the brain with room for improvement for high bandwidth non-invasive brain–computer interfacing.

Iivanainen, Joonas (ORCID:0000000160344604)↗

Transient shocks beyond the heliopause

The heliopause is a rich, dynamic surface affected by the time-dependent solar wind. Stream interactions due to coronal mass ejections (CMEs), corotating interaction regions (CIRs), and other transient phenomena are known to merge producing global merged interaction regions (GMIRs). Numerical simulations of the solar wind interaction with the local interstellar medium (LISM) show that GMIRs, as well other time-dependent structures in the solar wind, may produce compression/rarefaction waves and shocks in the LISM behind the heliopause. These shocks may initiate wave activity observed by the Voyager spacecraft. The magnetometer onboard Voyager 1 indeed observed a few structures that may be interpreted as shocks. We present numerical simulations of such shocks in the year of 2000, when both Voyager spacecraft were in the supersonic solar wind region, and in 2012, when Voyager 1 observed traveling shocks. In the former case, Voyager observations themselves provide time- dependent boundary conditions in the solar wind. In the latter case, we use OMNI data at 1 AU to analyze the plasma and magnetic field behavior after Voyager 1 crossed the heliospheric boundary. Numerical results are compared with spacecraft observations.

79 ASTRONOMY AND ASTROPHYSICS↗

A new cryogenic apparatus to search for the neutron electric dipole moment

A cryogenic apparatus is described that enables a new experiment, nEDM@SNS, with a major improvement in sensitivity compared to the existing limit in the search for a neutron Electric Dipole Moment (EDM). This apparatus uses superfluid 4 He to produce a high density of Ultra-Cold Neutrons (UCN) which are contained in a suitably coated pair of measurement cells. The experiment, to be operated at the Spallation Neutron Source at Oak Ridge National Laboratory, uses polarized 3 He from an Atomic Beam Source injected into the superfluid 4 He and transported to the measurement cells where it serves as a co-magnetometer. The superfluid 4 He is also used as an insulating medium allowing significantly higher electric fields, compared to previous experiments, to be maintained across the measurement cells. Finally, these features provide an ultimate statistical uncertainty for the EDM of 2-3× 10 -28 e-cm, with anticipated systematic uncertainties below this level.

47 OTHER INSTRUMENTATION↗

Engineering diamond interfaces free of dark spins

Nitrogen-vacancy (NV) centers in diamond are utilized extensively as quantum sensors for imaging fields at the nanoscale. The ultrahigh sensitivity of NV magnetometers has enabled the detection and spectroscopy of individual electron spins, with potentially far-reaching applications in condensed matter physics, spintronics, and molecular biology. However, the surfaces of these diamond sensors naturally contain electron spins, which create a background signal that can be hard to differentiate from the signal of the target spins. In this study, we develop a surface modification approach that eliminates the unwanted signal of these so-called dark electron spins. Our surface passivation technique, based on coating diamond surfaces with a thin titanium oxide (Ti⁢O 2 ) layer, reduces the dark spin density. The observed reduction in dark spin density aligns with our findings on the electronic structure of the diamond-Ti⁢O 2 interface. The reduction, from a typical value of 2000 μm −2 to a value below that set by the detection limit of our NV sensors (200 μm −2 ), results in a twofold increase in Hahn-echo coherence time of near surface NV centers. Furthermore, we derive a comprehensive spin model that connects dark spin relaxation with NV coherence, providing additional insights into the mechanisms behind the observed spin dynamics. Our findings are directly transferable to other quantum platforms, including nanoscale solid-state qubits and superconducting qubits.

74 ATOMIC AND MOLECULAR PHYSICS↗

Backaction-evading impulse measurement with mechanical quantum sensors

The quantum measurement of any observable naturally leads to noise added by the act of measurement. Approaches to evade or reduce this noise can lead to substantial improvements in a wide variety of sensors, from laser interferometers to precision magnetometers and more. In this paper, we develop a measurement protocol based upon pioneering work by the gravitational wave community which allows for reduction of added noise from measurement by coupling an optical field to the momentum of a small mirror. As a specific implementation, we present a continuous measurement protocol using a double-ring optomechanical cavity. We demonstrate that, with experimentally relevant parameters, this protocol can lead to significant backaction noise evasion, yielding measurement noise below the standard quantum limit over many decades of frequency.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Variational quantum state preparation for quantum-enhanced metrology in noisy systems

Here, we investigate optimized quantum state preparation for quantum metrology applications in noisy environments. Using the QFI-OPT package, we simulate a low-depth variational quantum circuit (VQC) composed of a sequence of global rotations and entangling operations applied to a chain of qubits that are subject to dephasing noise. The parameters controlling the VQC are numerically optimized to maximize the quantum Fisher information, which characterizes the ultimate metrological sensitivity of a quantum state with respect to a global rotation. We find that, regardless of the details of the entangling operation implemented in the VQC, the optimal quantum states can be broadly classified into a trio of qualitative regimes, i.e., catlike, squeezed like, and product states, associated with different dephasing rates. Our findings are relevant for designing optimal state-preparation strategies for next-generation quantum sensors exploiting entanglement, such as time and frequency standards and magnetometers, aimed at achieving state-of-the-art performance in the presence of noise and decoherence.

quantum Fisher information↗

High-Field Magnetoresistance of Organic Semiconductors

The magnetoelectronic field effects in organic semiconductors at high magnetic fields are described by field-dependent mixing between singlet and triplet states of weakly bound charge-carrier pairs due to small differences in their Landé g factors that arise from the weak spin-orbit coupling in the material. In this work, we corroborate theoretical models for the high-field magnetoresistance of organic semiconductors, in particular of diodes made of the conducting polymer poly(3,4-ethylenedioxythiophene):poly(styrene-sulfonate) (PEDOT:PSS) at low temperatures, by conducting magnetoresistance measurements along with multifrequency continuous-wave electrically detected magnetic-resonance experiments. The measurements are performed on identical devices under similar conditions in order to independently assess the magnetic-field-dependent spin-mixing mechanism, the so-called Δg mechanism. Finally, an understanding of the microscopic origin of magnetoresistance in organic semiconductors is crucial for developing reliable magnetometer devices capable of operating over a broad range of magnetic fields of order 10 -7 - 10 T.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗