Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC RESONANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Assessing the Dosimetric Accuracy of Magnetic Resonance-Generated Synthetic CT Images for Focal Brain VMAT Radiation Therapy

Purpose: The purpose of this study was to assess the dosimetric accuracy of synthetic CT (MRCT) volumes generated from magnetic resonance imaging (MRI) data for focal brain radiation therapy. Methods and Materials: A study was conducted in 12 patients with gliomas who underwent both MR and CT imaging as part of their simulation for external beam treatment planning. MRCT volumes were generated from MR images. Patients' clinical treatment planning directives were used to create 12 individual volumetric modulated arc therapy (VMAT) plans, which were then optimized 10 times on each of their respective CT and MRCT-derived electron density maps. Dose metrics derived from optimization criteria, as well as monitor units and gamma analyses, were evaluated to quantify differences between the imaging modalities. Results: Mean differences between planning target volume (PTV) doses on MRCT and CT plans across all patients were 0.0% (range: −0.1 to 0.2%) for D{sub 95%}; 0.0% (−0.7 to 0.6%) for D{sub 5%}; and −0.2% (−1.0 to 0.2%) for D{sub max}. MRCT plans showed no significant changes in monitor units (−0.4%) compared to CT plans. Organs at risk (OARs) had average D{sub max} differences of 0.0 Gy (−2.2 to 1.9 Gy) over 85 structures across all 12 patients, with no significant differences when calculated doses approached planning constraints. Conclusions: Focal brain VMAT plans optimized on MRCT images show excellent dosimetric agreement with standard CT-optimized plans. PTVs show equivalent coverage, and OARs do not show any overdose. These results indicate that MRI-derived synthetic CT volumes can be used to support treatment planning of most patients treated for intracranial lesions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of resonant helical magnetic fields on plasma rotation

The effect of a resonant helical magnetic field on plasma rotation is investigated numerically based on the two fluid equations. It is found that depending on the frequency and the direction of the original plasma rotation, a static helical field of a small amplitude can either increase or decrease the rotation speed. With increasing the field amplitude, the plasma rotation frequency approaches the electron diamagnetic drift frequency but rotates in the ion drift direction. These results provide a new understanding of the recent experimental observations of TEXTOR [K. H. Finken et al., Phys. Rev. Lett. 94, 015003 (2005)].

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Resonant Spin Excitation in the High Temperature Superconductor Ba0.6K0.4Fe2As2

A new family of superconductors containing layers of iron arsenide has attracted considerable interest because of their high transition temperatures (T{sub c}), some of which are >50 K, and because of similarities with the high-{sub c} copper oxide superconductors. In both the iron arsenides and the copper oxides, superconductivity arises when an antiferromagnetically ordered phase has been suppressed by chemical doping. A universal feature of the copper oxide superconductors is the existence of a resonant magnetic excitation, localized in both energy and wavevector, within the superconducting phase. This resonance, which has also been observed in several heavy-fermion superconductors is predicted to occur when the sign of the superconducting energy gap takes opposite values on different parts of the Fermi surface, an unusual gap symmetry which implies that the electron pairing interaction is repulsive at short range. Angle-resolved photoelectron spectroscopy shows no evidence of gap anisotropy in the iron arsenides, but such measurements are insensitive to the phase of the gap on separate parts of the Fermi surface. Here we report inelastic neutron scattering observations of a magnetic resonance below T{sub c} in Ba{sub 0.6}K{sub 0.4}Fe{sub 2}As{sub 2}, a phase-sensitive measurement demonstrating that the superconducting energy gap has unconventional symmetry in the iron arsenide superconductors.

Christianson, Andrew D↗

Negative Index of Refraction Observed in a Single Layer of ClosedRing Magnetic Dipole Resonators

We report the results of a spectroscopic study of a singlelayer of metallic single closed ring resonators on free-standing thinmembrane at near-normal and grazing angles of incidence. When themagnetic component of the light is perpendicular to the ring plane, weobserve a negative index of refraction down to -1 around 150 terahertz(THz), attributed to a strong magnetic dipolar resonance and a broadelectric resonance in this metamaterial. We experimentally identify thedifferent resonance modes and the spectral region of negative refractiveindex on a series of samples with different feature and lattice sizes,comparing to electromagnetic simulations.

36 MATERIALS SCIENCE↗

Current-induced spin torque resonance of magnetic insulators affected by field-like spin-orbit torques and out-of-plane magnetizations

The spin-torque ferromagnetic resonance (ST-FMR) in a bilayer system consisting of a magnetic insulator such as Y{sub 3}Fe{sub 5}O{sub 12} and a normal metal with spin-orbit interaction such as Pt is addressed theoretically. We model the ST-FMR for all magnetization directions and in the presence of field-like spin-orbit torques based on the drift-diffusion spin model and quantum mechanical boundary conditions. ST-FMR experiments may expose crucial information about the spin-orbit coupling between currents and magnetization in the bilayers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Huygens’ Metasurfaces Enabled by Magnetic Dipole Resonance Tuning in Split Dielectric Nanoresonators

Dielectric metasurfaces that exploit the different Mie resonances of nanoscale dielectric resonators are a powerful platform for manipulating electromagnetic fields and can provide novel optical behavior. Here in this work, we experimentally demonstrate independent tuning of the magnetic dipole resonances relative to the electric dipole resonances of split dielectric resonators (SDRs). By increasing the split dimension, we observe a blue shift of the magnetic dipole resonance toward the electric dipole resonance. Therefore, SDRs provide the ability to directly control the interaction between the two dipole resonances within the same resonator. For example, we achieve the first Kerker condition by spectrally overlapping the electric and magnetic dipole resonances and observe significantly suppressed backward scattering. Moreover, we show that a single SDR can be used as an optical nanoantenna that provides strong unidirectional emission from an electric dipole source.

36 MATERIALS SCIENCE↗

Framework Stability of Nanocrystalline NaY in Aqueous Solution at Varying pH

Nanocrystalline zeolites (with crystal sizes of less than 50 nm) are versatile, porous nanomaterials with potential applications in a broad range of areas including bifunctional catalysis, drug delivery, environmental protection, and sensing, to name a few. The characterization of the properties of nanocrystalline zeolites on a fundamental level is critical to the realization of these innovative applications. Nanocrystalline zeolites have unique surface chemistry that is distinct from conventional microcrystalline zeolite materials and that will result in novel applications. In the proposed work, magnetic resonance techniques (solid state nuclear magnetic resonance (NMR) and electron paramagnetic resonance (EPR)) will be used to elucidate the structure and reactivity of nanocrystalline zeolites and to motivate bifunctional applications. Density functional theory (DFT) calculations will enhance data interpretation through chemical shift, quadrupole coupling constant, g-value and hyperfine calculations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Strong reduction of V{sup 4+} amount in vanadium oxide/hexadecylamine nanotubes by doping with Co{sup 2+} and Ni{sup 2+} ions: Electron paramagnetic resonance and magnetic studies

In this work we present a complete characterization and magnetic study of vanadium oxide/hexadecylamine nanotubes (VO{sub x}/Hexa NT's) doped with Co{sup 2+} and Ni{sup 2+} ions. The morphology of the NT's has been characterized by transmission electron microscopy, while the metallic elements have been quantified by the instrumental neutron activation analysis technique. The static and dynamic magnetic properties were studied by collecting data of magnetization as a function of magnetic field and temperature and by electron paramagnetic resonance. At difference of the majority reports in the literature, we do not observe magnetic dimers in vanadium oxide nanotubes. Also, we observed that the incorporation of metallic ions (Co{sup 2+}, S = 3/2 and Ni{sup 2+}, S = 1) decreases notably the amount of V{sup 4+} ions in the system, from 14-16% (nondoped case) to 2%-4%, with respect to the total vanadium atoms (fact corroborated by XPS experiments) anyway preserving the tubular nanostructure. The method to decrease the amount of V{sup 4+} in the nanotubes improves considerably their potential technological applications as Li-ion batteries cathodes.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A fast determination method for transverse relaxation of spin-exchange-relaxation-free magnetometer

We propose a fast and accurate determination method for transverse relaxation of the spin-exchange-relaxation-free (SERF) magnetometer. This method is based on the measurement of magnetic resonance linewidth via a chirped magnetic field excitation and the amplitude spectrum analysis. Compared with the frequency sweeping via separate sinusoidal excitation, our method can realize linewidth determination within only few seconds and meanwhile obtain good frequency resolution. Therefore, it can avoid the drift error in long term measurement and improve the accuracy of the determination. As the magnetic resonance frequency of the SERF magnetometer is very low, we include the effect of the negative resonance frequency caused by the chirp and achieve the coefficient of determination of the fitting results better than 0.998 with 95% confidence bounds to the theoretical equation. The experimental results are in good agreement with our theoretical analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quality factor assessment of finite-size all-dielectric metasurfaces at the magnetic dipole resonance

Recently there has been a large interest in achieving metasurface resonances with large quality factors. In this article, we examine metasurfaces that comprised a finite number of magnetic dipoles oriented parallel or orthogonal to the plane of the metasurface and determine analytic formulas for their resonances’ quality factors. These conditions are experimentally achievable in finite-size metasurfaces made of dielectric cubic resonators at the magnetic dipole resonance. Our results show that finite metasurfaces made of parallel (to the plane) magnetic dipoles exhibit low quality factor resonances with a quality factor that is independent of the number of resonators. More importantly, finite metasurfaces made of orthogonal (to the plane) magnetic dipoles lead to resonances with large quality factors, which ultimately depend on the number of resonators comprising the metasurface. In particular, by properly modulating the array of dipole moments by having a distribution of resonator polarizabilities, one can potentially increase the quality factor of metasurface resonances even further. These results provide design guidelines to achieve a sought quality factor applicable to any resonator geometry for the development of new devices such as photodetectors, modulators, and sensors.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Transition Metal Dissolution Mechanisms and Impacts on Electronic Conductivity in Composite LiNi 0.5 Mn 1.5 O 4 Cathode Films

The high-voltage LiNi 0.5 Mn 1.5 O 4 (LNMO) spinel cathode material offers high energy density storage capabilities without the use of costly Co that is prevalent in other Li-ion battery chemistries (e.g., LiNi x Mn y Co z O 2 (NMC)). Unfortunately, LNMO-containing batteries suffer from poor cycling performance because of the intrinsically coupled processes of electrolyte oxidation and transition metal dissolution that occurs at high voltage. In this work, we use operando electron paramagnetic resonance (EPR) and nuclear magnetic resonance (NMR) spectroscopies to demonstrate that transition metal dissolution in LNMO is tightly coupled to HF formation (and thus, electrolyte oxidation reactions as detected with operando and in situ solution NMR), indicative of an acid-driven disproportionation reaction that occurs during delithiation (i.e., battery charging). Leveraging the temporal resolution (s-min) of magnetic resonance, we find that the LNMO particles accelerate the rate of LiPF 6 decomposition and subsequent Mn 2+ dissolution, possibly due to the acidic nature of terminal Mn-OH groups. X-ray photoemission electron microscopy (XPEEM) provides surface-sensitive and localized X-ray absorption spectroscopy (XAS) measurements, in addition to X-ray photoelectron spectroscopy (XPS), that indicate disproportionation is enabled by surface reconstruction upon charging, which leads to surface Mn 3+ sites on the LNMO particle surface that can disproportionate into Mn 2+ (dissolved) and Mn 4+ (s) . During discharge of the battery, we observe high quantities of metal fluorides (in particular, MnF 2 ) in the cathode electrolyte interphase (CEI) on LNMO as well as the conductive carbon additives in the composite. Electronic conductivity measurements indicate that the MnF 2 decreases film conductivity by threefold compared to LiF, suggesting that this CEI component may impede both the ionic and electronic properties of the cathode. Ultimately, to prevent transition metal dissolution and the associated side reactions in spinel-type cathodes (particularly those that operate at high voltages like LNMO), the use of electrolytes that offer improved anodic stability and prevent acid byproducts will likely be necessary.

36 MATERIALS SCIENCE↗

Electronic Structure of Fullerene Acceptors in Organic Bulk-Heterojunctions. A Combined EPR and DFT Study

Organic photovoltaic (OPV) devices are a promising alternative energy source. Attempts to improve their performance have focused on the optimization of electron-donating polymers, while electron-accepting fullerenes have received less attention. Here, we report an electronic structure study of the widely used soluble fullerene derivatives PC61BM and PC71BM in their singly reduced state, that are generated in the polymer:fullerene blends upon light-induced charge separation. Density functional theory (DFT) calculations characterize the electronic structures of the fullerene radical anions through spin density distributions and magnetic resonance parameters. The good agreement of the calculated magnetic resonance parameters with those determined experimentally by advanced electron paramagnetic resonance (EPR) allows the validation of the DFT calculations. Thus, for the first time, the complete set of magnetic resonance parameters including directions of the principal g-tensor axes were determined. For both molecules, no spin density is present on the PCBM side chain, and the axis of the largest g-value lies along the PCBM molecular axis. While the spin density distribution is largely uniform for PC61BM, it is not evenly distributed for PC71BM.

14 SOLAR ENERGY↗

Enhanced Activity from Coordinatively Unsaturated and Dynamic Zeolite-Bound Organoscandium Species

Scandium borohydride grafted into the micropores of the faujasite zeolite HY30 catalyzes the C–H borylation of benzene, whereas silica-grafted species are inactive. This catalytic activity may originate from grafting at a Brønsted acid site leading to a more electron-deficient rare earth center. Herein, we apply multinuclear double-resonance nuclear magnetic resonance (NMR) experiments to probe the structure and dynamics of zeolite- and silica-bound scandium borohydride complexes. The experiments reveal that scandium centers located within the zeolite micropores, in proximity to Al-created Brønsted sites, are more dynamic than rigid scandium sites grafted on silanols. Through a combination of NMR and molecular dynamics simulations, we show that the coordination of the scandium in the zeolite is labile, with the metal exchanging between two binding sites. As a result, the weak electron donation from the support that enables the movement of the Sc center leads to the formation of an undercoordinated metal center that cannot exist on silica, ultimately leading to the new catalytic activity of the species.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Kinetic linear model of the interaction of helical magnetic perturbations with cylindrical plasmas

The linear kinetic model of the interaction of helical rotating magnetic perturbations (resonant and nonresonant) with a tokamak plasma developed in [M. F. Heyn et al., Nucl. Fusion 46, S159 (2006)] is extended by a Galilean invariant collision operator and a different finite Larmor radius expansion scheme of particle current density. The model is applied to study the plasma screening effect on resonant magnetic perturbations and the resulting torques acting on the plasma at various orders of Larmor radius expansion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Microturbulence studies of pulsed poloidal current drive discharges in the reversed field pinch

Experimental discharges with pulsed poloidal current drive (PPCD) in the Madison Symmetric Torus reversed field pinch are investigated using a semi-analytic equilibrium model in the gyrokinetic turbulence code GENE. PPCD cases, with plasma currents of 500 kA and 200 kA, exhibit a density-gradient-driven trapped electron mode (TEM) and an ion temperature gradient mode, respectively. Relative to expectations of tokamak core plasmas, the critical gradients for the onset of these instabilities are found to be greater by roughly a factor of the aspect ratio. A significant upshift in the nonlinear TEM transport threshold, previously found for tokamaks, is confirmed in nonlinear reversed field pinch simulations and is roughly three times the threshold for linear instability. The simulated heat fluxes can be brought in agreement with measured diffusivities by introducing a small, resonant magnetic perturbation, thus modeling the residual fluctuations from tearing modes. These fluctuations significantly enhance transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dispersion Validation for Flow Involving a Large Structure Revisited: 45 Degree Rotation

The atmospheric dispersion of contaminants in the wake of a large urban structure is a challenging fluid mechanics problem of interest to the scientific and engineering communities. Magnetic Resonance Velocimetry (MRV) and Magnetic Resonance Concentration (MRC) are relatively new techniques that leverage diagnostic equipment used primarily by the medical field to make 3D engineering measurements of flow and contaminant dispersal. SIERRA/Fuego, a computational fluid dynamics (CFD) code at Sandia National Labs is employed to make detailed comparisons to the dataset to evaluate the quantitative and qualitative accuracy of the model. This work is the second in a series of scenarios. In the prior work, a single large building in an array of similar buildings was considered with the wind perpendicular to a building face. In this work, the geometry is rotated by 45 degrees and improved studies are performed for simulation credibility. The comparison exercise shows conditionally good comparisons between the model and experiment. Model uncertainties are assessed through parametric variations. Various methods of quantifying the accuracy between experiments and data are examined Three-dimensional analysis of accuracy is performed. The effort helped identify deficiencies in the techniques used to make these comparisons, and further methods development therefore becomes one of the main recommendations for follow-on work.

42 ENGINEERING↗

Influence of interface exchange coupling in perpendicular anisotropy [Pt/Co]50/TbFe bilayers

We present the magnetization evolution of perpendicular anisotropy TbFe and [Co/Pt]{sub 50} thin films either in direct contact resulting in antiferromagnetic interfacial coupling or separated by a thick Pt layer. Magnetometry and x-ray magnetic circular dichroism spectroscopy determine the spatially averaged magnetic properties. Resonant magnetic x-ray small-angle scattering and magnetic soft X-ray transmission microscopy probed the domain configurations and correlations in the reversal processes. While the Co/Pt multilayer reverses by domain propagation, the TbFe magnetization reversal is found to be dominated either by coherent magnetization reversal processes or by lateral domain formation depending on the interface exchange coupling. In the presence of lateral domains, dipolar field induced domain replication phenomena are observed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Efficient synthesis of quantum gates on a three-spin system with triangle topology

Experiments in coherent nuclear and electron magnetic resonance and optical spectroscopy correspond to control of quantum-mechanical ensembles, guiding them from initial states to target states by unitary transformations. The control inputs (pulse sequences) that accomplish these unitary transformations should take as little time as possible so as to minimize the effects of relaxation and decoherence, and to optimize the sensitivity of the experiments. Here, we give an efficient synthesis of a class of unitary transformations on a three coupled spin-(1/2) system with equal Ising coupling strengths. We show a significant time saving compared with conventional methods.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗