The MSP 2001 Mars Environmental Compatibility Assessment (MECA)

A chemical analysis of soil-water mixtures and the first microscopic images of martian soil will be among the results to be returned by the Mars Environmental Compatibility Assessment (MECA) payload on the Mars Surveyor Program 2001 Lander. Sponsored by the Human Exploration and Development of Space (HEDS) enterprise, MECA's primary goal is to evaluate potential geochemical and environmental hazards that may confront future martian explorers, and to guide HEDS scientists in the development of high fidelity Mars soil simulants. As a survey of soil properties, the MECA data set will also be rich in information relevant to basic geology, paleoclimate, and exobiology. The integrated MECA payload contains a wet-chemistry laboratory, a microscopy station, an electrometer to characterize the electrostatics of the soil and its environment, and arrays of material patches to study the abrasive and adhesive properties of soil grains. MECA is allocated a mass of 10 kg and a peak power usage of 15 W within an enclosure of 35 x 25 x 15 cm. The Wet Chemistry Laboratory (WCL) consists of four identical cells that will accept samples from surface and subsurface regions accessible to the Lander's robotic arm, mix them with water, and perform extensive analysis of the solution. Ion-selective electrodes and related sensors will evaluate total dissolved solids, redox potential, pH, and the concentration of many soluble ions and gases. Cyclic voltammetry will address oxidants, and anodic stripping voltammetry will probe potentially hazardous trace metals. MECA's microscopy station combines optical and atomic-force microscopy (AFM) in a controlled illumination environment to image dust and soil particles from millimeters to nanometers in size. Careful selection of substrates and an abrasion tool allows experimental study of size distribution, adhesion, abrasion, hardness, color, shape, aggregation, magnetic and other properties. Mounted on the end of the robot arm, MECA's electrometer consists of four types of sensors: an electric field meter, several triboelectricity monitors, an ion gauge, and a thermometer. Tempered only by ultra-violet- light-induced ions and a low-voltage break-down threshold, the dry, cold, dusty martian environment presents an imposing electrostatic hazard to both robots and humans. In addition, the electrostatic environment is key to transport of dust and, consequently, martian meteorology. MECA will also observe natural dust accumulation on engineering materials. Viewed with the robot arm camera, the abrasion and adhesion plates are strategically placed to allow direct observation of the inter-action between materials and soils on a macroscopic scale. Materials of graded hardness are placed directly under the robot arm scoop to sense wear and soil hardness. A second array, placed on the lander deck, is deployed after the dust plume of landing has settled. It can be manipulated in a primitive fashion by the arm, first having dirt deposited on it from the scoop and subsequently shaken clean. Dust accumulation as a function of conductivity, magnetic field strength, and other parameters will be explored. The MECA instruments described above will assess potential hazards that the Martian soil might present to human explorers and their equipment. In addition, MECA will provide information on the composition of ancient surface water environments, observing microscopic evidence of geological (and biological?) processes, inferring soil and dust transport, comminution and weathering mechanisms, and characterizing soil horizons that might be encountered during excavation. Additional information is contained in the original extended abstract.

Hecht, M. H.↗

Method Developed for Noninterference Measurement of Blade Damping

Although noninterference optical instrumentation has been previously used to monitor and measure rotor blade vibrations, it has not been used at the NASA Glenn Research Center for the determination of damping. This article describes such a measurement in Glenn's Spin Rig facility. The optical system was chosen because installation of the slip rig for this particular configuration was not feasible, ruling out strain gauge instrumentation. The shaft in this facility was suspended with two radial magnetic bearings, and the excitation was supplied to the bearings by a signal generator. For the first mode, the direction of excitation force was always perpendicular to the blade as described by Morrison. The preceding graph shows blade displacements, as measured by an optical probe during a frequency sweep designed to locate the first mode resonance. The resonance determines the frequency at which the shaft is excited. Because the sampling rate was fixed to only once per revolution with these transducers, and the first mode frequency was much larger than the rotational frequency, the data in this figure were undersampled with an apparent frequency that was only 1 Hz at the beginning of the sweep, about 14 Hz at the maximum amplitude, and about 20 Hz at the end of the sweep. The true excitation frequency varied during the sweep from 320 to 340 Hz, and the resonance occurred at 334 Hz. Damping is determined by applying a frequency burst to the shaft. Upon cessation of the burst, the blade undergoes free decay. The apparent damping is then obtained by a least squares fit of the theoretical cosine decay function through the experimental points. The following graph illustrates this procedure. Because of frequency aliasing, the apparent measured damping must be divided by the ratio of the true resonant frequency to the apparent measured frequency to obtain the true damping. Note that the contribution of the shaft vibration to the blade vibration could be neglected because it was shown that it is an order of magnitude smaller and that its decay is an order of magnitude faster.

Kurkov, Anatole P.↗

EMI Performance of the AIRS Cooler and Electronics

The TRW pulse tube cryocooler for JPL's Atmospheric Infrared Sounder (AIRS) instrument is required to meet stringent requirements for radiated electric and magnetic fields, conducted emissions on the input power bus, and electromagnetic susceptivility.

EMI AIRS Cooler Electronics Cryocooler↗

Chromospheric LAyer SpectroPolarimeter (CLASP2)

The sounding rocket Chromospheric Lyman-Alpha SpectroPolarimeter (CLASP) was launched on September 3rd, 2015, and successfully detected (with a polarization accuracy of 0.1 %) the linear polarization signals (Stokes Q and U) that scattering processes were predicted to produce in the hydrogen Lyman-alpha line (Ly; 121.567 nm). Via the Hanle effect, this unique data set may provide novel information about the magnetic structure and energetics in the upper solar chromosphere. The CLASP instrument was safely recovered without any damage and we have recently proposed to dedicate its second ight to observe the four Stokes profiles in the spectral region of the Mg II h and k lines around 280 nm; in these lines the polarization signals result from scattering processes and the Hanle and Zeeman effects. Here we describe the modifications needed to develop this new instrument called the "Chromospheric LAyer SpectroPolarimeter" (CLASP2).

CLASP↗

The 2008 Mars Phoenix Lander Thermal and Evolved Gas Analyzer (TEGA) Dataset: Placing Easily Interpretable Evolved Gas Data on the Planetary Data System (PDS)

The Phoenix Scout Lander mission investigated the north polar region of Mars in 2008 with the goal to study the history of water, assess the past/present Martian climate, search for organics, and evaluate the potential for past/present microbial habit-ability on Mars. To accomplish this goal, the Phoenix Lander’s Thermal and Evolved-Gas Analyzer (TEGA) instrument assessed the gas composition of the Martian atmosphere and evaluated the mineralogy of the Martian regolith. The TEGA instrument consisted of eight small ovens connected to a 4 channel magnetic sector mass spectrometer. The ovens heated soil samples from ambient to 1000°C where the gases (e.g., H2O, CO2, etc.) evolved from thermal decomposition of mineral phases were analyzed by the mass spectrometer. Minerals thermally decomposed at characteristic temperatures and the evolving gases indicated the presence of perchlorate, carbonate, and hydrated phases in the Phoenix landing site soils.

Garcia, A. H.↗

The Atmosphere-Space Transition Region Explorer (ASTRE) – A Low Perigee Satellite to Investigate the Coupling of the Earth’s Upper Atmosphere and Magnetosphere

The Atmosphere-Space Transition Region Explorer (ASTRE) is a mission concept designed to carry out an unprecedented study of the interaction between the Earth’s atmosphere and the ionized gases of space within the atmosphere-space transition region. By gathering direct measurements of the coupling of ion and neutral gases in this region, ASTRE provides the critical missing link in our knowledge of the transfer, dissipation, and regulation of energy and momentum between the sun and the upper atmosphere. ASTRE provides the first detailed, systematic investigation of this important unexplored region, vastly improves and constrains models of the upper atmosphere, and fills a critical gap in our understanding of how the coupled lower ionosphere/upper atmosphere “works” as a system. To achieve its science objectives, ASTRE gathers accurate measurements of plasma and neutral gases, electric and magnetic fields, and energetic particles using well-proven, in situ instruments with excellent flight heritage. Furthermore, as described herein, all the instruments have been designed to perform well in the low perigee environment, including altitudes of 150 km and lower. ASTRE utilizes a three-axis stabilized satellite that uses on-board propulsion to carry out systematic, low perigee measurements at high latitudes. The satellite design incorporates a “form follows function” approach with a cylindrical shape and conductive body-mounted solar arrays to minimize drag and perturbations to the space environment. Atomic-oxygen resistant materials are utilized and a passive thermal design with heat pipes and radiator panels minimizes the impact of aero-heating. ASTRE launches into a 250 km × 1500 km elliptical insertion orbit with an inclination of 83°. Perigee precesses from its highest northern latitude to its highest southern latitude every ~60 days. Hydrazine propulsion provides over 2000 orbits with perigee below 200 km, with a significant fraction as low as 150 km, during high latitude, two-week campaigns when perigee precesses to either the northern or southern high latitude region. At mid and low latitudes, the perigee is near 225 km. Because very conservative assumptions were made with respect to the orbital analysis and drag, including continuous 3-sigma “worst-case” solar flux and atmospheric density, when additional propellant is included (accommodated in the current design) and some of the stringent assumptions are relaxed, the ASTRE mission described herein may be expected to include repeated excursions to altitudes of ~130 km or even lower. This paper presents an overview of the ASTRE mission, its science motivation, and objectives. It includes a discussion of the science-driven requirements and traceability, followed by a “proof-of concept” implementation that includes notional instruments and a straightforward spacecraft design. Three key points are demonstrated: 1) There is a critical knowledge gap in the high latitude, atmosphere-space transition region below 250 km; 2) The instrument and measurement techniques needed to obtain the ASTRE measurements are well-proven and function well in the low-altitude environment; and 3) A mature spacecraft design, flight dynamics analysis, and concept of operations have been developed that demonstrate that the ASTRE mission can be achieved in a straightforward manner using current technologies.

Ionosphere↗

Muon g-2 Experiment Shimming

The Muon g-2 experiment at Fermilab will use as its primary instrument a 52-foot-wide electromagnet that creates a precise magnetic field. In this video, Fermilab's Brendan Kiburg explains the lengthy process of finely "shimming" that magnetic field into shape.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fuel Property Characterization and Prediction

The Fuel Property Characterization and Prediction effect with the Co-Optimization of Fuels and Engines (Co-Optima) initiative is focused on the measurement or prediction of key fuel properties. Efforts under the Vehicle Technologies Office (VTO) have focused on understanding how fuel evaporation phenomena can impact auto-ignition, mixing, and pollutant formation by studying the most important azeotropic interactions between alcohols and gasoline components utilizing a novel Differential Scanning Calorimetry/Thermogravimetric Analysis instrument coupled to a Mass Spectrometer (DSC/TGA/MS). In another effort, Nuclear Magnetic Resonance (NMR) measurements were utilized to understand how oxygenate clusters and networks contribute to vapor pressure effects. This is critical for predicting fuel droplet evaporation and effects on combustion. A method was developed on the Advanced Fuel Ignition Delay Analyzer (AFIDA) to rapidly measure the Research Octane Number (RON) and Sensitivity (S) of samples utilizing small volumes, which will aid in the pace of development of new fuels having targeted properties. Additionally, the AFIDA was employed to develop a method for fast measurement of phi-sensitivity in a bench-scale test that will allow studies of molecular structure effects on mechanism kinetics of this poorly understood kinetic phenomena. A flow reactor was also utilized to investigate the mechanistic basis of phi-sensitivity by identifying and quantitating key species in autoignition mechanisms that can explain phi-sensitivity. The outcomes of these efforts will help ensure that the Co-Optima program can advance the underlying science needed to develop biomass-derived-fuel and advanced engine technologies that will work in tandem to achieve Co-Optima's efficiency, environmental, and economic goals.

33 ADVANCED PROPULSION SYSTEMS↗

A Superconducting Magnet Upgrade of the ATF2 Final Focus

The ATF2 facility at KEK is a proving ground for linear collider technology with a well instrumented extracted beam line and Final Focus (FF). The primary ATF2 goal is to demonstrate the extreme beam demagnification and spot stability needed for a linear collider FF. But the ATF2 FF uses water cooled magnets and the ILC baseline has a superconducting (SC) FF. We plan to upgrade ATF2 and replace some of the warm FF magnets with SC FF magnets. The ATF2 SC magnets, like the ILC FF, will made via direct wind construction. ATF2 coil winding is in progress at BNL and warm magnetic measurements indicate we have achieved good field quality. Studies indicate that having ATF2 FF magnets with larger aperture and better field quality should allow reducing the ATF2 FF beta function for study of focusing regimes relevant to CLIC. The ATF2 magnet cryostat will have laser view ports for directly monitoring cold mass movement. We plan to make stability measurements at BNL and KEK to relate ATF2 FF magnet performance to that of a full length ILC QD0 R and D FF prototype under construction at BNL.

43 PARTICLE ACCELERATORS↗

A Superconducting Magnet Upgrade of the ATF2 Final Focus

The ATF2 facility at KEK is a proving ground for linear collider technology with a well instrumented extracted beam line and Final Focus (FF). The primary ATF2 goal is to demonstrate the extreme beam demagnification and spot stability needed for a linear collider FF. But the ATF2 FF uses water cooled magnets and the ILC baseline has a superconducting (SC) FF. We plan to upgrade ATF2 and replace some of the warm FF magnets with SC FF magnets. The ATF2 SC magnets, like the ILC FF, will made via direct wind construction. ATF2 coil winding is in progress at BNL and warm magnetic measurements indicate we have achieved good field quality. Studies indicate that having ATF2 FF magnets with larger aperture and better field quality should allow reducing the ATF2 FF beta function for study of focusing regimes relevant to CLIC. The ATF2 magnet cryostat will have laser view ports for directly monitoring cold mass movement. We plan to make stability measurements at BNL and KEK to relate ATF2 FF magnet performance to that of a full length ILC QD0 R&D FF prototype under construction at BNL.

43 PARTICLE ACCELERATORS↗

Imaging crystal spectrometer for high-resolution x-ray measurements on electron beam ion traps and tokamaks

Here, we describe a crystal spectrometer implemented on the Livermore electron beam ion traps that employ two spherically bent quartz crystals and a cryogenically cooled back-illuminated charge-coupled device detector to measure x rays with a nominal resolving power of λ/Δλ ≥ 10 000. Its focusing properties allow us to record x rays either with the plane of dispersion perpendicular or parallel to the electron beam and, thus, to preferentially select one of the two linear x-ray polarization components. Moreover, by choice of dispersion plane and focussing conditions, we use the instrument either to image the distribution of the ions within the 2 cm long trap region, or to concentrate x rays of a given energy to a point on the detector, which optimizes the signal-to-noise ratio. We demonstrate the operation and utility of the new instrument by presenting spectra of Mo 34+ , which prepares the instrument for use as a core impurity diagnostic on the NSTX-U spherical torus and other magnetic fusion devices that employ molybdenum as plasma facing components.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proton deflectometry with in situ x-ray reference for absolute measurement of electromagnetic fields in high-energy-density plasmas

In this work, we report a technique of proton deflectometry that uses a grid and an in situ reference x-ray grid image for precise measurements of magnetic fields in high-energy-density plasmas. A D 3 He fusion implosion provides a bright point source of both protons and x-rays, which is split into beamlets by a grid. The protons undergo deflections as they propagate through the plasma region of interest, whereas the x-rays travel along straight lines. The x-ray image, therefore, provides a zero-deflection reference image. The line-integrated magnetic fields are inferred from the shifts of beamlets between the deflected (proton) and reference (x-ray) images. We developed a system for analysis of these data, including automatic algorithms to find beamlet locations and to calculate their deflections from the reference image. The technique is verified in an experiment performed at OMEGA to measure a nonuniform magnetic field in vacuum and then applied to observe the interaction of an expanding plasma plume with the magnetic field.

47 OTHER INSTRUMENTATION↗

The FIELDS Instrument Suite on MMS: Scientific Objectives, Measurements, and Data Products

The FIELDS instrumentation suite on the Magnetospheric Multiscale (MMS) mission provides comprehensive measurements of the full vector magnetic and electric fields in the reconnection regions investigated by MMS, including the dayside magnetopause and the night-side magnetotail acceleration regions out to 25 Re. Six sensors on each of the four MMS spacecraft provide overlapping measurements of these fields with sensitive cross-calibrations both before and after launch. The FIELDS magnetic sensors consist of redundant flux-gate magnetometers (AFG and DFG) over the frequency range from DC to 64 Hz, a search coil magnetometer (SCM) providing AC measurements over the full whistler mode spectrum expected to be seen on MMS, and an Electron Drift Instrument (EDI) that calibrates offsets for the magnetometers. The FIELDS three-axis electric field measurements are provided by two sets of biased double-probe sensors (SDP and ADP) operating in a highly symmetric spacecraft environment to reduce significantly electrostatic errors. These sensors are complemented with the EDI electric measurements that are free from all local spacecraft perturbations. Cross-calibrated vector electric field measurements are thus produced from DC to 100 kHz, well beyond the upper hybrid resonance whose frequency provides an accurate determination of the local electron density. Due to its very large geometric factor, EDI also provides very high time resolution (∼1 ms) ambient electron flux measurements at a few selected energies near 1 keV. This paper provides an overview of the FIELDS suite, its science objectives and measurement requirements, and its performance as verified in calibration and cross-calibration procedures that result in anticipated errors less than 0.1 nT in B and 0.5 mV/m in E. Summaries of data products that result from FIELDS are also described, as well as algorithms for cross-calibration. Details of the design and performance characteristics of AFG/DFG, SCM, ADP, SDP, and EDI are provided in five companion papers.

Electromagnetic field measurements↗

Laboratory testing of a supercritical helium pump for a magnetic refrigerator

A supercritical helium testing system for a magnetic refrigerator has been built. Details of the supercritical helium pump, the test system, and the test instrumentation are given. Actual pump tests were not run during this ASEE term because of delivery problems associated with the required pump flow meter. Consequently, efforts were directed on preliminary design of the magnetic refrigeration system for the pump. The first concern with the magnetic refrigerator design was determining how to effectively make use of the pump. A method to incorporate the supercritical helium pump into a magnetic refrigerator was determined by using a computer model. An illustrated example of this procedure is given to provide a tool for sizing the magnetic refrigerator system as a function of the pump size. The function of the computer model and its operation are also outlined and discussed.

Wang, Pao-Lien↗

Invited Article: An integrated mid-infrared, far-infrared, and terahertz optical Hall effect instrument

We report on the development of the first integrated mid-infrared, far-infrared, and terahertz optical Hall effect instrument, covering an ultra wide spectral range from 3 cm{sup −1} to 7000 cm{sup −1} (0.1–210 THz or 0.4–870 meV). The instrument comprises four sub-systems, where the magneto-cryostat-transfer sub-system enables the usage of the magneto-cryostat sub-system with the mid-infrared ellipsometer sub-system, and the far-infrared/terahertz ellipsometer sub-system. Both ellipsometer sub-systems can be used as variable angle-of-incidence spectroscopic ellipsometers in reflection or transmission mode, and are equipped with multiple light sources and detectors. The ellipsometer sub-systems are operated in polarizer-sample-rotating-analyzer configuration granting access to the upper left 3 × 3 block of the normalized 4 × 4 Mueller matrix. The closed cycle magneto-cryostat sub-system provides sample temperatures between room temperature and 1.4 K and magnetic fields up to 8 T, enabling the detection of transverse and longitudinal magnetic field-induced birefringence. We discuss theoretical background and practical realization of the integrated mid-infrared, far-infrared, and terahertz optical Hall effect instrument, as well as acquisition of optical Hall effect data and the corresponding model analysis procedures. Exemplarily, epitaxial graphene grown on 6H-SiC, a tellurium doped bulk GaAs sample and an AlGaN/GaN high electron mobility transistor structure are investigated. The selected experimental datasets display the full spectral, magnetic field and temperature range of the instrument and demonstrate data analysis strategies. Effects from free charge carriers in two dimensional confinement and in a volume material, as well as quantum mechanical effects (inter-Landau-level transitions) are observed and discussed exemplarily.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Difficulties in Observing Coronal Structure

There has developed in recent years a substantial body of evidence to indicate that the temperature and density structure of the corona are far more complicated than had previously been thought. We review some of the evidence and discuss some specific examples: observations of a limb flare, showing that the cool H-alpha material is cospatial with the hot X-ray emitting material: simultaneous NIXT and Yohkoh SXT observations of an active region, showing that loops seen in one instrument are not seen in the other, and that the effect works in both directions; comparisons of extrapolated magnetic field measurements to the observed coronal structure, indicating that neither potential nor constant-e force-free fits are adequate. We conclude with a description of two new instruments, the TRACE and the TXI, which will help to resolve some of these difficulties.

Golub, Leon↗

An imaging vector magnetograph for the next solar maximum

Researchers describe the conceptual design of a new imaging vector magnetograph currently being constructed at the University of Hawaii. The instrument combines a modest solar telescope with a rotating quarter-wave plate, an acousto-optical tunable prefilter as a blocker for a servo-controlled Fabry-Perot etalon, CCD cameras, and on-line digital image processing. Its high spatial resolution (1/2 arcsec pixel size) over a large field of view (5 by 5 arcmin) will be sufficient to significantly measure, for the first time, the magnetic energy dissipated in major solar flares. Its millisecond tunability and wide spectral range (5000 to 7000 A) enable nearly simultaneous vector magnetic field measurements in the gas-pressure-dominated photosphere and magnetically-dominated chromosphere, as well as effective co-alignment with Solar-A's X ray images. Researchers expect to have the instrument in operation at Mees Solar Observatory (Haleakala) in early 1991. They have chosen to use tunable filters as wavelength-selection elements in order to emphasize the spatial relationships between magnetic field elements, and to permit construction of a compact, efficient instrument. This means that spectral information must be obtained from sequences of images, which can cause line profile distortions due to effects of atmospheric seeing.

Mickey, D. L.↗