Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNET SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Biomaterials and Magnetic fields for Cancer Therapy

The field of biomaterials has emerged as an important topic in the purview of NASA s new vision of research activities in the Microgravity Research Division. Although this area has an extensive track record in the medical field as borne out by the routine use of polymeric sutures, implant devices, and prosthetics, novel applications such as tissue engineering, artificial heart valves and controlled drug delivery are beginning to be developed. Besides the medical field, biomaterials and bio-inspired technologies are finding use in a host of emerging interdisciplinary fields such as self-healing and self-assembling structures, biosensors, fuel systems etc. The field of magnetic fluid technology has several potential applications in medicine. One of the emerging fields is the area of controlled drug delivery, which has seen its evolution from the basic oral delivery system to pulmonary to transdermal to direct inoculations. In cancer treatment by chemotherapy for example, targeted and controlled drug delivery has received vast scrutiny and substantial research and development effort, due to the high potency of the drugs involved and the resulting requirement to keep the exposure of the drugs to surrounding healthy tissue to a minimum. The use of magnetic particles in conjunction with a static magnetic field allows smart targeting and retention of the particles at a desired site within the body with the material transport provided by blood perfusion. Once so located, the therapeutical aspect (radiation, chemotherapy, hyperthermia, etc.) of the treatment, now highly localized, can be implemented.

Ramachandran, Narayanan↗

Superconducting thin-film gyroscope readout for Gravity Probe-B

The high-resolution gyroscope readout system for the Stanford Gravity Probe-B experiment, whose purpose is to measure two general relativistic precessions of gyroscopes in earth orbit, is described. In order to achieve the required resolution in angle (0.001 arcsec), the readout system combines high-precision mechanical fabrication and measurement techniques with superconducting thin-film technology, ultralow magnetic fields, and SQUID detectors. The system design, performance limits achievable with current technology, and the results of fabrication and laboratory testing to date are discussed.

Lockhart, James M.↗

Five degree-of-freedom control of an ultra-precision magnetically-suspended linear bearing

The authors constructed a high precision linear bearing. A 10.7 kg platen measuring 125 mm by 125 mm by 350 mm is suspended and controlled in five degrees of freedom by seven electromagnets. The position of the platen is measured by five capacitive probes which have nanometer resolution. The suspension acts as a linear bearing, allowing linear travel of 50 mm in the sixth degree of freedom. In the laboratory, this bearing system has demonstrated position stability of 5 nm peak-to-peak. This is believed to be the highest position stability yet demonstrated in a magnetic suspension system. Performance at this level confirms that magnetic suspensions can address motion control requirements at the nanometer level. The experimental effort associated with this linear bearing system is described. Major topics are the development of models for the suspension, implementation of control algorithms, and measurement of the actual bearing performance. Suggestions for the future improvement of the bearing system are given.

Trumper, David L.↗

Passive Magnetic Bearing

Magnetic bearing for limited rotation devices requires no feedback control system to sense and correct shaft position. Passive Magnetic Torsion Bearing requires no power supply and has no rubbing parts. Torsion wire restrains against axial instability. Magnetic flux geometry chosen to assure lateral stability with radial restoring force that maintains alignment.

Studer, P. A.↗

A CAD approach to magnetic bearing design

A design methodology has been developed at the Magnetic Bearing Research Laboratory for designing magnetic bearings using a CAD approach. This is used in the algorithm of an interactive design software package. The package is a design tool developed to enable the designer to simulate the entire process of design and analysis of the system. Its capabilities include interactive input/modification of geometry, finding any possible saturation at critical sections of the system, and the design and analysis of a control system that stabilizes and maintains magnetic suspension.

Jeyaseelan, M.↗

Violation of Field Line Conservation and Associated Spatial Scales in Particle-In-Cell Simulations and MMS Data

For the first time, space flight technology exists to detect, in situ, violation of magnetic field line conservation. The violation of magnetic line conservation on scales smaller than the system size is a necessary and sufficient condition for finite magnetic field reconnection. We demonstrate that violation of line conservation produces a detectable, structured signature both in particle-in-cell simulations of reconnection and in data from the Magnetospheric Multi-Scale mission. In particle-in-cell simulations of asymmetric reconnection, the quantity-which we call M-that identifies this violation achieves significant values in electron skin depth-scale layers that extend away from the separator, with higher values emerging on the low-density, high-magnetic-field side of the current sheet. At the separator, M owes largely to perpendicular gradients in the parallel electric field, while it attains its highest values away from the separator in dispersed, layered structures associated with gradients in the perpendicular nonideal electric field and electron transport. Sub-ion scale bipolar forms of the quantity also appear further from the separator. In two MMS burst data intervals detecting the electron diffusion region, we find that M exceeds measurement uncertainties both at the separator and near the separatrices. One interval has highly sheared reconnecting fields and the other a stronger guide field. For one event, we determine the location and scale of M and the inner electron diffusion region relative to electron outflows and the magnetic separatrices. The measure can therefore serve as a potent diagnostic for magnetic reconnection in space measurements.

Wendel, Deirdre E.↗

Effect of low-frequency ambient magnetic fields on the control unit and RF head of a commercial SQUID magnetometer

The control unit and RF head of the SHE model 330XRFSQUID system are shown to be sensitive to ambient ac magnetic fields below 1 HZ, which cause the appearance of false signals corresponding to a magnetometer signal of 0.000001 phi(0) per gauss of field applied. The control unit shows a sensitivity that is linear with frequency, suggesting that the signal is generated by Faraday induction. In contrast, the RF head response is independent of frequency and shows a strong second-harmonic coversion. This response may be due to the magnetic field sensitivity of the ferrite core inductor in the tuned amplifier of the RF head. These signals induced by ambient fields are a potential source of error in Stanford's Relativity Gyroscope experiment, which uses SQUID's on board a rolling satellite as part of the gyroscope readout system. The extent of the magnetic field sensitivity in these components necessitates the use of additional magnetic shielding aboard the satellite.

Marcus, C. M.↗

Magnetostrophic balance in planetary dynamos - Predictions for Neptune's magnetosphere

With the purpose of estimating Neptune's magnetic field and its implications for nonthermal Neptune radio emissions, a new scaling law for planetary magnetic fields was developed in terms of externally observable parameters (the planet's mean density, radius, mass, rotation rate, and internal heat source luminosity). From a comparison of theory and observations by Voyager it was concluded that planetary dynamos are two-state systems with either zero intrinsic magnetic field (for planets with low internal heat source) or (for planets with the internal heat source sufficiently strong to drive convection) a magnetic field near the upper bound determined from magnetostrophic balance. It is noted that mass loading of the Neptune magnetosphere by Triton may play an important role in the generation of nonthermal radio emissions.

Curtis, S. A.↗

Evidence for Langmuir oscillations and a low density cavity in the Venus magnetotail

We report the discovery of Langmuir oscillations in a very low plasma density region in the Venus magnetotail. These waves are observed more often at 30 kHz, but also at 5.4 kHz indicating densities as low as 0.3 cu cm in the central tail lobe. The Langmuir probe on board the Pioneer Venus Orbiter cannot resolve such a low plasma density. We use the magnetic field strength and the assumption of total pressure balance to infer the electron temperature as a test of the Langmuir wave interpretation. By investigating the spatial distribution of this wave activity we find that the plasma cavity is ordered in a coordinate system defined by the interplanetary magnetic field and is found at either side of the central tail current sheet.

Ho, C. M.↗

Evidence for Langmuir Oscillations and a Low Density Cavity in the Venus Magnetotail

We report the discovery of Langmuir oscillations in a very low plasma density region in the Venus magnetotail. These waves are observed more often at 30 kHz, but also at 5.4 kHz indicating densities as low as 0.3/cu cm in the central tail lobe. The Langmuir probe on board the Pioneer Venus Orbiter cannot resolve such a low plasma density. We use the magnetic field strength and the assumption of total pressure balance to infer the electron temperature as a test of the Langmuir wave interpretation. By investigating the spatial distribution of this wave activity we find that the plasma cavity is ordered in a coordinate system defined by the interplanetary magnetic field and is found at either side of the central tail current sheet.

Ho, C. M.↗

MAGSAT: Vector magnetometer absolute sensor alignment determination

A procedure is described for accurately determining the absolute alignment of the magnetic axes of a triaxial magnetometer sensor with respect to an external, fixed, reference coordinate system. The method does not require that the magnetic field vector orientation, as generated by a triaxial calibration coil system, be known to better than a few degrees from its true position, and minimizes the number of positions through which a sensor assembly must be rotated to obtain a solution. Computer simulations show that accuracies of better than 0.4 seconds of arc can be achieved under typical test conditions associated with existing magnetic test facilities. The basic approach is similar in nature to that presented by McPherron and Snare (1978) except that only three sensor positions are required and the system of equations to be solved is considerably simplified. Applications of the method to the case of the MAGSAT Vector Magnetometer are presented and the problems encountered discussed.

Acuna, M. H.↗

Standing Alfven wave current system at Io - Voyager 1 observations

The enigmatic control of the occurrence frequency of Jupiter's decametric emissions by the satellite Io has been explained theoretically on the basis of its strong electrodynamic interaction with the corotating Jovian magnetosphere leading to field-aligned currents connecting Io with the Jovian ionosphere. Direct measurements of the perturbation magnetic fields due to this current system were obtained by the Goddard Space Flight Center magnetic field experiment on Voyager 1 on March 5, 1979, when it passed within 20,500 km south of Io. An interpretation in the framework of Alfven waves radiated by Io leads to current estimates of 2.8 x 10 to the 6th A. A mass density of 7400-13,600 proton mass units/cu cm is derived, which compares very favorably with independent observations of the torus composition characterized by 7-9 proton mass units per electron for a local electron density of 1050-1500/cu cm. The power dissipated in the current system may be important for heating the Io heavy ion torus, inner magnetosphere, Jovian ionosphere, and possibly the ionosphere or even the interior of Io.

Acuna, M. H.↗

Critical speeds and forced response solutions for active magnetic bearing turbomachinery, part 1

The prediction of critical speeds and forced response of active magnetic bearing turbomachinery is of great interest due to the increased use of this new and promising technology. Calculating the system undamped critical speeds and forced response is important to all those who are involved in the design of the active magnetic bearing system. An extended Jeffcott model which was used as an approximate solution to a more accurate transfer matrix procedure is presented. Theory behind a two-degree-of freedom extended Jeffcoat model is presented. Results of the natural frequency calculation are shown followed by the results of the forced response calculation. The system response was predicted for two types of forcing. A constant magnitude excitation with a wide frequency variation was applied at the bearings as one forcing function. The normal unbalance force at the midspan was the second source of excitation. The results of this extended Jeffcott solution gives useful design guidance for the influence of the first and third modes of a symmetric rotor system.

Keesee, J.↗

Continued Development of the Pulsed Magnetic Nozzle for the Pulsed Fission Fusion (PuFF) Vehicle

High thrust, high specific impulse propulsion systems, such as PuFF (Pulsed Fission-Fusion)offer a new paradigm of speed and safety when exploring the solar system. To realize thesepossibilites, PuFF needs a mature magnetic nozzle design. PuFF’s magnetic nozzle is uniquein that it must provide power in addition to thrust. In the authors’ opinion, the power systemdesign is fairly mature, but nozzle thrust coil design is less so. Previous work has suggested thatthe PuFF magnetic nozzle will behave similarly to a ‘magnetic reflection chamber,’ relying onprinciples of magnetic flux compression to re-direct nozzle flow. However, recent work, usingthe 3D modeling software SPFMax, suggests that plasma motion in the nozzle will be drivenby the Lorentz force. This recent work is limited in that the plasma did not completely leavethe nozzle before the simulation ended. In this work, we aim to extend the SPFMax modelfrom previous work, with a bolstered electromagnetic field solver, so the model can run untilthe plasma is fully evacuated. We hope to confirm previous results regarding the ideal PuFFnozzle design, but we could be surprised. Through improving the PuFF nozzle model, weaim to reduce technical risk with building the nozzle, realize paradigm-shifting performancenumbers, and allow rapid, reliable, and safe exploration of the solar system.

Nathan M Schilling↗

A high-voltage-isolated automated data acquisition system

A data acquisition system for electric-arc heated, high-temperature wind tunnel facilities has been developed; the high voltage isolation of the system exceeds 50 kV. A closed loop, optically coupled data system acquires transducer signals from high-temperature, arc-generated plasmas used for reentry testing. The data acquisition system monitors on-line tests, stores data on magnetic tape, and prints out a paper tape. The system has 400 data channels: 200 low-voltage programmable channels and 200 high-voltage sequential channels.

Cox, J.↗