Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Laser coupling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

An Automated Microfluidic Assay for Photonic Crystal Enhanced Detection and Analysis of an Antiviral Antibody Cancer Biomarker in Serum

Here, we report on the implementation of an automated platform for detecting the presence of an antibody biomarker for human papillomavirus-associated oropharyngeal cancer from a single droplet of serum, in which a nanostructured photonic crystal surface is used to amplify the output of a fluorescence-linked immunosorbent assay. The platform is comprised of a microfluidic cartridge with integrated photonic crystal chips that interfaces with an assay instrument that automates the introduction of reagents, wash steps, and surface drying. Upon assay completion, the cartridge interfaces with a custom laser-scanning instrument that couples light into the photonic crystal at the optimal resonance condition for fluorescence enhancement. The instrument is used to measure the fluorescence intensity values of microarray spots corresponding to the biomarkers of interest, in addition to several experimental controls that verify correct functioning of the assay protocol. In this work, we report both dose-response characterization of the system using anti-E7 antibody introduced at known concentrations into serum and characterization of a set of clinical samples from which results were compared with a conventional enzyme-linked immunosorbent assay (ELISA) performed in microplate format. Finally, the demonstrated capability represents a simple, rapid, automated, and high-sensitivity method for multiplexed detection of protein biomarkers from a low-volume test sample.

59 BASIC BIOLOGICAL SCIENCES↗

Spatially Resolved Characterisation of Low Mass Fraction Uranium Glass Working Reference Materials

Here, we present the results of a study to generate reference glasses that reflect an environment analogous to historic nuclear fallout samples of interest for post-detonation nuclear forensics. The glasses were generated by melting and then quenching SiO 2 , Al 2 O 3 and CaCO 3 powders. Two suites of glasses with three distinct U isotopic ratios were successfully made with enrichments in the 235 U isotope (~ natural [0.72%], ~ 53% and 94%), but the bulk elemental data showed heterogeneity (~ 10% RSD) with U mass fractions ranging from 331.47 to 373.63 μg g -1 . Spatially resolved U isotopic measurements were performed using three mass spectrometry techniques (secondary ion mass spectrometry-single stage accelerator mass spectrometry [SIMS-SSAMS], large geometry [LG] - SIMS, and laser ablation-inductively coupled plasma-mass spectrometry [LA-ICP-MS]) across five National Laboratories. The results showed good agreement with the bulk U isotopic data for the low, medium, and high U mass fractions. We conclude that despite elemental heterogeneity, these samples can serve as useful working reference materials for spatially resolved nuclear fallout analyses, as well as for other related spatially resolved analyses.

36 MATERIALS SCIENCE↗

Crystallization of rhenium salts in a simulated low-activity waste borosilicate glass

This study presents a new method for looking at the solubility of volatile species in simulated low-activity waste glass. The present study looking at rhenium salts is also applicable to real applications involving radioactive technetium salts. In this synthesis method, oxide glass powder is mixed with the volatiles species, vacuum-sealed in a fused quartz ampoule, and then heat-treated under vacuum in a furnace. This technique restricts the volatile species to the headspace above the melt but still within the sealed ampoule, thus maximizing the volatile concentration in contact with the glass. Various techniques were used to measure the solubility of rhenium in glass and include energy dispersive spectroscopy, wavelength dispersive spectroscopy, laser ablation inductively-coupled plasma mass spectroscopy, and inductively-coupled plasma optical emission spectroscopy. The Re-solubility in this glass was determined to be ~3004 parts per million Re atoms. Above this concentration, the salts separated out of the melt as inclusions and as a low viscosity molten salt phase on top of the melt observed during and after cooling. This salt phase was analyzed with X-ray diffraction, scanning electron microscopy as well as some of the other aforementioned techniques and identified to be composed of alkali perrhenate and alkali sulfate.

ampoule↗

Increased bundle‐sheath leakiness of CO 2 during photosynthetic induction shows a lack of coordination between the C 4 and C 3 cycles

Summary Use of a complete dynamic model of NADP‐malic enzyme C 4 photosynthesis indicated that, during transitions from dark or shade to high light, induction of the C 4 pathway was more rapid than that of C 3 , resulting in a predicted transient increase in bundle‐sheath CO 2 leakiness ( ϕ ). Previously, ϕ has been measured at steady state; here we developed a new method, coupling a tunable diode laser absorption spectroscope with a gas‐exchange system to track ϕ in sorghum and maize through the nonsteady‐state condition of photosynthetic induction. In both species, ϕ showed a transient increase to > 0.35 before declining to a steady state of 0.2 by 1500 s after illumination. Average ϕ was 60% higher than at steady state over the first 600 s of induction and 30% higher over the first 1500 s. The transient increase in ϕ , which was consistent with model prediction, indicated that capacity to assimilate CO 2 into the C 3 cycle in the bundle sheath failed to keep pace with the rate of dicarboxylate delivery by the C 4 cycle. Because nonsteady‐state light conditions are the norm in field canopies, the results suggest that ϕ in these major crops in the field is significantly higher and energy conversion efficiency lower than previous measured values under steady‐state conditions.

59 BASIC BIOLOGICAL SCIENCES↗

Speckle contrast diffuse correlation tomography of complex turbid medium flow

Purpose: Developed herein is a three-dimensional (3D) flow contrast imaging system leveraging advancements in the extension of laser speckle contrast imaging theories to deep tissues along with our recently developed finite-element diffuse correlation tomography (DCT) reconstruction scheme. This technique, termed speckle contrast diffuse correlation tomography (scDCT), enables incorporation of complex optical property heterogeneities and sample boundaries. When combined with a reflectance-based design, this system facilitates a rapid segue into flow contrast imaging of larger, in vivo applications such as humans. Methods: A highly sensitive CCD camera was integrated into a reflectance-based optical system. Four long-coherence laser source positions were coupled to an optical switch for sequencing of tomographic data acquisition providing multiple projections through the sample. This system was investigated through incorporation of liquid and solid tissue-like phantoms exhibiting optical properties and flow characteristics typical of human tissues. Computer simulations were also performed for comparisons. A uniquely encountered smear correction algorithm was employed to correct point-source illumination contributions during image capture with the frame-transfer CCD and reflectance setup. Results: Measurements with scDCT on a homogeneous liquid phantom showed that speckle contrast-based deep flow indices were within 12% of those from standard DCT. Inclusion of a solid phantom submerged below the liquid phantom surface allowed for heterogeneity detection and validation. The heterogeneity was identified successfully by reconstructed 3D flow contrast tomography with scDCT. The heterogeneity center and dimensions and averaged relative flow (within 3%) and localization were in agreement with actuality and computer simulations, respectively. Conclusions: A custom cost-effective CCD-based reflectance 3D flow imaging system demonstrated rapid acquisition of dense boundary data and, with further studies, a high potential for translatability to real tissues with arbitrary boundaries. A requisite correction was also found for measurements in the fashion of scDCT to recover accurate speckle contrast of deep tissues.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Geochemical and mineralogical controls on metal(loid) mobility in the oxide zone of the Prairie Creek Deposit, NWT

Prairie Creek is an unmined high grade Zn-Pb-Ag deposit in the southern Mackenzie Mountains of the Northwest Territories, located in a 320 km2 enclave surrounded by the Nahanni National Park reserve. The upper portion of the quartz-carbonate-sulphide vein mineralization has undergone extensive oxidation, forming high grade zones, rich in smithsonite (ZnCO3) and cerussite (PbCO3). This weathered zone represents a significant resource and a potential component of mine waste material. This study is focused on characterizing the geochemical and mineralogical controls on metal(loid) mobility under mine waste conditions, with particular attention to the metal carbonates as a potential source of trace elements to the environment. Analyses were conducted using a combination of microanalytical techniques (electron microprobe, scanning electron microscopy with automated mineralogy, laser-ablation inductively-coupled mass spectrometry, and synchrotron-based element mapping, micro-X-ray diffraction and micro-X-ray absorbance). The elements of interest included Zn, Pb, Ag, As, Cd, Cu, Hg, Sb and Se.

58 GEOSCIENCES↗

Data for Increased bundle sheath leakiness of CO2 during photosynthetic induction shows a lack of coordination between the C4 and C3 cycles

We developed a new application of isotopic gas exchange which couples a tunable diode laser absorption spectroscope (TDL) with a leaf gas exchange system, analyzing leakiness through induction of C4 photosynthesis on dark to high-light transitions. The youngest fully expanded leaf was measured on 40-45 day-old maize(B73) and sorghum (Tx430). Detail definition of each variable in raw Li-6400XT and Li-6800 (in "Original_data_AND_Data_processing_code.zip") is summarized in: https://www.licor.com/env/support/LI-6800/topics/symbols.html#const

bundle sheath leakage↗

Excitons in atomically thin 2D semiconductors and their applications

The research on emerging layered two-dimensional (2D) semiconductors, such as molybdenum disulfide (MoS 2 ), reveals unique optical properties generating significant interest. Experimentally, these materials were observed to host extremely strong light-matter interactions as a result of the enhanced excitonic effect in two dimensions. Thus, understanding and manipulating the excitons are crucial to unlocking the potential of 2D materials for future photonic and optoelectronic devices. Here in this review, we unravel the physical origin of the strong excitonic effect and unique optical selection rules in 2D semiconductors. In addition, control of these excitons by optical, electrical, as well as mechanical means is examined. Finally, the resultant devices such as excitonic light emitting diodes, lasers, optical modulators, and coupling in an optical cavity are overviewed, demonstrating how excitons can shape future 2D optoelectronics.

36 MATERIALS SCIENCE↗

Multimodal Nondestructive Dry Cask Basket Structure and Spent Fuel Evaluation

This NEUP-IRP assembled a team from diverse institutions and a diverse set of expertise to examine the problem of assessing the structural health of dry nuclear fuel storage casks, specifically the TN-32 design. With no physical access designed into these storage casks and the high cost and risk associated with opening casks for direct inspection, the technical difficulty of structural assessment of the basket structure and fuel assemblies is high. In response to this challenge, this IRP brought together experts in both traditional and novel NDE methodologies: active acoustics (University of Mississippi), emissions tomography (University of Florida), muon tomography (Oregon State University), and passive-active ultrasonics (University of South Carolina). Further, our industry partners in the Electric Power Research Institute (EPRI) and AREVA provided invaluable insight into technical design details for the cask, practical knowledge of operating parameters at a storage facility, and key relationships that enabled activities unforeseen at the time of the proposed work but were critical in guiding the path of the research. The team decided early in the project that we had a collective goal of laying the technical ground work for practical solutions that could be implemented in the field with reasonable cost, time, and reliability. A fortunate opportunity arose early in this IRP project to obtain access to a new TN-32 cask at Columbiana High Tech. Both acoustics teams were given access for testing concepts in the first year of the project. This ended up providing critical guidance in the design of subsequent laboratory experiments. Specifically, it became clear that the only reliable acoustic pathways to the interior were through the trunnions, base plate, and top ring of the cask. Based on these field tests and discussions about what would be of practical interest, the team as a whole decided a realistic goal was to detect catastrophic failure of a single fuel assembly, or one that was missing. It is clear from this work that the active acoustics / resonance and muon tomography methodologies would be capable of detecting interior structural integrity problems at this level. The other two areas of investigation (emissions tomography and passive/active ultrasonics) would need more testing to determine a successful implementation, but each may also have other applications such as long term monitoring and monitoring during transportation. This IRP project resulted in technical advances with applications that extend beyond the problem at hand, supported the training of 10 graduate students + 1 post doc, 21 publications, and 13 conference presentations. The remainder of this summary highlights significant activities and achievements in each of the methodologies and a brief discussion on how they can be combined to leverage strengths. Active Acoustics The active acoustics team at UM used both linear and non-linear structural resonance methods to infer information about the internal structure of a cask. Significant activities were a set of four field test measurements on a full scale TN-32 cask at the Columbiana Hi Tech facility in Greensboro, NC and the design and fabrication of a 1/6th scale model TN-32 cask for laboratory measurements. A significant set of acoustic data has been acquired on both the full scale and laboratory scale casks. It was determined early in the project that mechanical resonance techniques were not going to be sensitive to small scale (centimeter) cracks and structural defects in the basket structure or fuel assemblies. We were able to ascertain that both the energy and complexity of the resonance spectra were sensitive to “bulk state” of the fuel assemblies – an intact assembly versus a severely degraded assembly. By developing a novel combination of metrics, we are able to measure a statistically significant shift due to one out of the 32 fuel assemblies being either missing or degraded to a point of complete loss of structural coherence (i.e. “rubble”). We believe this combination of resonance metrics is new to the field and will have applications beyond the fuel storage problem. Emissions Tomography The Emissions Tomography team at the University of Florida explored the concept of using scattering of radiation emissions from the stored fuel as method of evaluating the internal structural health of the cask. Due to the need for emissive fuel assemblies and the difficulties of gaining access to storage facilities, this team primarily relied on simulations to inform feasibility. A key question was the flux estimates of neutrons with a small enough number of scattering events to retain spatial information. Some key conclusions from the transmission component of this work are that the number of scattering events falls rapidly with energy – setting a 11MeV threshold, the average number of scattering events is 8∓4. Rough estimates of scanning times using an ideal detector array would be 1 week. The team also explored the case of significant structural failure resulting in a shift of the source material (fuel). The result is that a +/- 2% mass shift results in a detectable (5.13%) shift in the correlated 2 neutron emission counts and thus may be a candidate as an initial survey. Finally, simulations for predicting the azimuthal dependence of the flux based on specific loading patterns were conducted. Due to self-shielding effects of the assemblies, a periodic pattern results and could potentially be used to identify missing or severely degraded assemblies. This work forms a basis for proper detector placement with the goal of optimizing sensitivity. Muon Tomography Muon tomography (MT) is a relatively novel method of interrogating interior structure on a large scale. One of the advantages of this technique is that the exciting energy source (cosmic muons) is ubiquitous and relatively stable in time. Challenging aspects are relatively low flux rates and appropriate detector technologies. The efforts of the muon group at Oregon State University focused on two areas: (1) simulation of various combinations of muon scattering events and detection schemes to assess sensitivities and time scales for image construction and (2) building a prototype muon detection system applicable to the dry storage cask problem as well as many other similar systems. Significant accomplishments in this area are: (1) demonstration that MT is a viable method for detecting missing or severely degraded rod assemblies, (2) a scintillation based detector with 4 panels and 32 channels of position data each were constructed, tested, and calibrated. Testing of the panels using natural muon background and no scattering objects yielded largely expected results – a straight line path for the muon through the four panels. However some anomalies (paths deviating from a line) were also detected. A redesign of the board improved the signal which greatly improved the muon tracking through the panels. Testing with lead bricks as scattering bodies showed a reduction in the coincidence rate with increasing bricks indicating increased scattering events. A refinement of the scintillator detector design resulted in a spatial image resolution of around 2 cm based on lead brick spacing tests lasting 24 hours. Passive/Active Ultrasonics This team at the University of South Carolina investigated the feasibility of combining passive ultrasonics, in which an elastic pulse is generated by a degradation process (such as a crack extending), and active ultrasonics, in which a known excitation is introduced into the structure and detected by an array of transducers. Significant accomplishments in this area include the development of elastic wave propagation simulation in relevant materials, development of diagnostic algorithms, and laboratory testing and validation using laser doppler vibrometry. This group demonstrated the applicability of various non-contact vibration detection methodologies such as air-coupled ultrasonic transducers and scanning laser doppler vibrometry. While passive acoustic emissions monitoring will likely have a role during the transportation of a fuel storage cask, the level of detailed information about the defect generating the event which can be ascertained from the detections in a complex structure remains for future work. Thermography The EPRI team contributed early in the project a series of thermography measurements in which various levels of water pooled in a mock-up canister were analyzed using commercially available infrared imaging technologies. While large levels of water (100 L, ~10 cm deep) were observable in the thermograms, more realistic levels of pooled water (1 L) were not detectable whether localized or distributed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Time-Resolved, NIR Two-Tone Frequency Modulation Spectroscopy for Quantitative Measurement of HO 2 Radical in Fuel Oxidation Reactions

Time-resolved two-tone frequency modulation (TTFM) absorption spectroscopy has been used to measure, in situ and quantitatively, hydroperoxy (HO 2 ) radical in fuel oxidation reactions at the first overtone transitions (2v 1 ) of HO 2 near 1509nm. Typical HO 2 detection limit is on the order of 10 11 molecule cm -3 , which corresponds to a relative absorption of 10 -5 . TTFM method successfully removes low frequency thermal lensing noise in measured HO 2 kinetic time traces, which is a general noise source in fuel oxidation absorption experiments. Compared with previous works, we have upgraded the TTFM experiment with a NIR distributed feedback (DFB) diode laser, a fiber-coupled broadband phase modulator, and a two-channel wave generator, which have improve the performance of our experiment substantially.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reduced diffusion and enhanced retention of multiple radionuclides from pore structure characterization of barrier materials for enhanced repository performance

Fluid flow and chemical transport in porous media are the macroscopic consequences of pore structure, which integrates geometry (e.g., pore size and surface area, pore-size distribution) and topology (e.g., pore connectivity). Low-permeability geological media whose pores are poorly interconnected will exhibit the characteristics of anomalous diffusion and sample size-dependent effective porosity, which will strongly impact long-term net diffusion and retention of radionuclides in geological repository settings involving different host rocks and barrier materials. A suite of innovative and complementary experimental approaches is utilized to study the microscopic pore structure and macroscopic fluid flow & chemical transport for a range of host rocks and barrier materials, in addition to standard clay minerals and reference rocks. With a particular focus on quantifying the presence and magnitude of “isolated” pores for a reduced effective porosity in low-permeability geomedia, the integrated methodologies for basic properties and pore structure characterization of these geomedia include X-ray diffraction, thin section petrography, grain size distribution, water immersion porosimetry after vacuum-pulling for full saturation, mercury intrusion porosimetry, nitrogen physisorption, scanning electron microscopy, X-ray computed tomography, and (ultra-)small angle neutron (X-ray) scattering. In addition, custom-designed gas diffusion, tracer recipe involving a range of anionic and cationic chemicals with subsequent analyses by laser ablation and inductively coupled plasma-mass spectrometry, along with batch sorption, column transport, and imbibition tests were conducted for coupled effects of pore structure and chemical retention/transport. From the perspectives of pore structure in conjunction with multiple and complementary approaches to examining a range of sample sizes under different observational scales, we find that the poor pore connectivity is prevalent in low-permeability media (mudstone and crystalline rock) that is related to geological processes (e.g., compaction, diagenesis and thermal maturation). For example, the deep and organic matter-rich mudstones have a much smaller effective porosity than the total porosity (as a result of poor pore connectivity) and associated diffusion coefficient, and the effective porosity & diffusion coefficients are also dependent upon the sample sizes used in the measurement. Similarly, most of the pore space in the shallow mudstone is also controlled by pore-throat diameters in the 5-50 nm range of intergranular pore types from its fine-grained nature, but with an overall good pore connectivity. However, the nm-sized pore space (physically pore-network architecture) and strong sorption capacities (chemical retention from clay minerals) of both shallow and deep mudstones lead to the synergistic retention of cationic radionuclides and their utilities as effective host rocks and barrier materials. Our unique approaches of studying how the micro-scale pore structure affect macro-scale fluid flow, diffusion & retention, and chemical transport produce improved mechanistic understanding, and realistic quantification, of diffusion and retention of typical radionuclides in a range of generic host rocks and barrier materials (clay/shale, salt, crystalline rock, and tuff), with the overall results leading to scientifically-based understanding of enhanced isolation (from both diffusion and retention) of radionuclides and improved confidence on the long-term performance of geological repository to store high-level radioactive wastes. In addition to the training of 25 undergraduates, graduates, and postdocs of UTA, the scientists (organizations) involved in performing this work (e.g., discussion, sample sharing, and operation of SANS and SAXS instruments) include Ed Matteo, Yifeng Wang, and Kristopher Kuhlman (Sandia National Laboratories), Jens Birkholzer, Liange Zheng, Tim Kneafsey, and Sharon Borglin (Lawrence Berkeley National Laboratory), Mavrik Zavarin (Lawrence Livermore National Laboratory), Yukio Tachi and Yuta Fukatsu (Japan Atomic Energy Agency), Mieke de Craen (Euridice, Belgium), Markus Bleuel (NIST), Wei-Ren Chen, Gergely Nagy, Changwoo Do, William Heller, Larry Anovitz, and Kenneth Littrell (ORNL), as well as Jan Illvsky, Ivan Kuzmenko, Ju-Sang Park and Jon Almers (ANL). Key deliverables include a total of 13 peer-reviewed journal articles (nine published and three under review), 23 presentations at scientific conferences (AAPG, AAPG Southwest Section, AGU, Asian Clay Conference, GSA, GSA South-Central Section, IHLRWM, InterPore, International Conference on Chemistry and Migration Behavior of Actinides and Fission Products in the Geosphere, International Conference on Coupled Processes in Fractured Geological Media: Observation, Modeling and Application), and academic institutions (UTA, New Mexico State University; University of Poitiers, France; University of Helsinki, Finland; Uppsala University, Sweden; Istanbul Technical University, Turkey) and other organizations (Andra, France; Posiva Oy, Finland).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

REACTIVITY OF OH AND CH{sub 3}OH BETWEEN 22 AND 64 K: MODELING THE GAS PHASE PRODUCTION OF CH{sub 3}O IN BARNARD 1b

In recent years, ultra-low temperature chemical kinetic experiments have demonstrated that some gas-phase reactions are much faster than was previously thought. One example is the reaction between OH and CH{sub 3}OH, which has recently been found to be accelerated at low temperatures yielding CH{sub 3}O as its main product. This finding raised the question of whether or not the CH{sub 3}O observed in the dense core Barnard 1b could be formed by the gas-phase reaction of CH{sub 3}OH and OH. Several chemical models including this reaction and grain-surface processes have been developed to explain the observed abundance of CH{sub 3}O, but they have met with little success. Here, we report for the first time the rate coefficients for the gas-phase reaction of OH and CH{sub 3}OH down to a temperature of 22 K, which is very close to the temperature in cold interstellar clouds. Two independent experimental set-ups based on the supersonic gas expansion technique coupled to the pulsed laser photolysis laser-induced fluorescence technique were used to determine the rate coefficients in the temperature range 22–64 K. The temperature dependence obtained in this work can be expressed as k(22–64 K) = (3.6±0.1)×10{sup −12}(T/300K){sup −(1.0±0.2)} cm{sup 3} molecule{sup −1} s{sup −1}. Implementing this expression in a chemical model of a cold, dense cloud results in CH{sub 3}O/CH{sub 3}OH abundance ratios similar to or slightly lower than the value of ∼3 × 10{sup −3} observed in Barnard 1b. This finding confirms that the gas-phase reaction between OH and CH{sub 3}OH is an important contributor to the formation of interstellar CH{sub 3}O. The role of grain-surface processes in the formation of CH{sub 3}O, although it cannot be fully neglected, remains controversial.

79 ASTRONOMY AND ASTROPHYSICS↗

Integrated optics technology study

The materials and processes available for the fabrication of single mode integrated electrooptical components are described. Issues included in the study are: (1) host material and orientation, (2) waveguide formation, (3) optical loss mechanisms, (4) wavelength selection, (5) polarization effects and control, (6) laser to integrated optics coupling,(7) fiber optic waveguides to integrated optics coupling, (8) souces, (9) detectors. The best materials, technology and processes for fabrication of integrated optical components for communications and fiber gyro applications are recommended.

Chen, B.↗

Integrated optics technology study

The status and near term potential of materials and processes available for the fabrication of single mode integrated electro-optical components are discussed. Issues discussed are host material and orientation, waveguide formation, optical loss mechanisms, wavelength selection, polarization effects and control, laser to integrated optics coupling fiber optic waveguides to integrated optics coupling, sources, and detectors. Recommendations of the best materials, technology, and processes for fabrication of integrated optical components for communications and fiber gyro applications are given.

Chen, B.↗

Optoelectronic gain control of a microwave single stage GaAs MESFET amplifier

Gain control of a single stage GaAs MESFET amplifier is demonstrated by the use of optical illumination of photon energy greater than the GaAs bandgap. The optical illumination is supplied by a semiconductor laser diode and is coupled to the Schottky gate of the MESFET by an optical fiber. The increase in gain is observed to be as much as 5.15 dB when the MESFET is biased close to pinchoff, that is, V(sub gs) equals -1.5 V and with optical illumination of 1.5 mW. The computed maximum available gain (MAG) and current gain (bar h sub 21 bar) from the de-embedded s-parameters show that MAG is unaffected by optical illumination, however, bar h(sub 21)bar increases by more than 2 dB under optical illumination of 1.5 mW. The maximum frequency of oscillation (F sub max) and the unity current gain cut-off frequency (F sub t) obtained by extrapolating the MAG and bar h(sub 21)bar curves, respectively, show that the F(sub max) is insensitive to optical illumination but F(sub t) increases by 5 GHz.

Simons, Rainee N.↗