Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Integrable systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Integrated electrochemical nuclear decontamination system

An electrochemical cell that oxidizes a solution provides a continuous and stable supply of an oxidizing ion solution to a fixture or vessel used for the purposes of decontaminating metal and metal alloys. The electrochemical cell includes an anode compartment that oxidizes the solution in nitric acid or methane sulfonic acid at a rate equal to or greater than a rate of reduction, or generates the oxidizing ions prior to use in a batch. The electrochemical cell is part of a larger system that facilitates online measurement system which measures the oxidizing ion solution and the dissolved PuO 2 , UO 2 , AmO 2 , other radionuclides, or other contaminates in real-time. Solution decontamination system removes the dissolved PuO 2 /UO 2 /AmO 2 , other radionuclides, or other contaminates from the oxidizing ion solution, real time acoustic monitoring of the thickness of the surface being contaminated, and automation of a delivery system facilitates flow between surface and electrochemical cell.

Karmiol, Benjamin↗

A Causal Approach to Integrate Component Health Data into System Reliability Models

Two of the challenges of current plant reliability approaches are the ability to integrate plant health data, and to support decision making. Condition based data and diagnostic/prognostic information are in fact not considered into plant reliability models to inform system engineers on the most critical components. Currently, the propagation of quantitative health data from the component to the system level is a challenge given the diverse nature/structure of the data. On the other hand, plant reliability methods (which are typically based on fault-trees or reliability block diagrams) can effectively propagate data from the component to the system level, but values of failure rates or failure probabilities are an approximated integral representation of the past industry-wide operational experience, and it neglects the present component health status (e.g., diagnostic and condition-based data) and health projection (when available from prognostic data). Our first claim is that system reliability models should propagate health information from the component to the system/plant level in order to provide a quantitative snapshot of system/plant health and identify the most critical components. Our second claim is that component health should be informed solely by that specific component current and historical performance data and should not be an approximated integral representation of the past industry-wide operational experience. This paper is directly supporting these two claims by proposing a different approach to perform reliability modeling which relies on available component diagnostic, prognostic and condition-based data to measure component health, and it propagates this information through fault tree models. The propagation of health data from the component to the system level is performed not in terms of probability, but in terms of margins where margin is defined as the “distance” between the present actual status and an undesired event (e.g., failure or unacceptable performance). Through a cause-effect lens, while classical reliability models target the effect associated to a component performance, a margin-based approach focuses on the cause of an undesired component performance (i.e., component health). Hence, thinking of reliability in terms of margins implies decision making based on causal reasoning. We will show how fault tree models can be solved using a margin language and how this process can effectively assist system engineers to identify the most critical components.

97 MATHEMATICS AND COMPUTING↗

Flood Susceptibility Mapping Using Machine Learning and Geospatial-Sentinel-1 SAR Integration for Enhanced Early Warning Systems

This study presents a comprehensive framework for flood susceptibility mapping by integrating geospatial factors with both statistical and machine learning models. Thirteen Flood-related factors, including DEM, slope, TWI, NDVI, etc., are extracted as features of models, and historical flood data derived from Sentinel-1 SAR from 2018 to 2023 are used as the target variables of the models. These datasets are analyzed using a frequency-based statistical model and three machine learning models, including Random Forest, XGBoost, and CNN, to generate flood susceptibility maps. The performance of each model is evaluated through AUC; and SHAP scores are separately generated for Machine learning (ML) models to explain each feature contribution in the ML model. The generated susceptibility maps are validated by high-flood-risk locations monitored by flood sensors, BLE inundation models, and flood-prone areas suggested by the Local Community Task Force. The results indicate that the XGBoost model outperforms all other models, with an AUC of 0.92 and demonstrates the highest alignment with recommended high-flood-risk locations, while the frequency-based statistical model showed the weakest performance with an AUC of 0.65. SHAP value graphs highlight the elevation, slope, and TWI as the most influential features across all models. The susceptibility maps generated by the machine learning model show strong agreement with the BLE map and high-flood-risk areas identified by the local Community Task Force.

Google Engine↗

Development of Electro-chemical Battery Model for Plug-and-Play Eco-system Library

Energy storage components are fundamental to the concept of an Integrated Energy System (IES). They serve to store surplus energy during low-demand periods for later release when other IES components (i.e., Secondary Energy Source, Balance of Plant, etc.) would otherwise have to operate flexibly. This provision for storage avoids high-amplitude power ramps in these components thereby limiting thermal and mechanical stresses to their internals and providing for extended service life. This report describes a dynamic model that has been developed for an electrochemical battery. The lithium-ion (Li-ion) cell was selected as representative technology. The battery model was developed in the Dymola simulation environment and meets the requirements of the ecosystem plug-and-play library. The model accurately describes the electric dynamic response of a Li-ion battery for an imposed charging/discharging power profile. The corresponding physical limitations related to over-power scenarios, and the impact of the residual state of charge are accounted for in the model. A literature review of the major degradation processes affecting Li-ion batteries was performed. Given the purposes of the CTD-IES project, the progressive fade of the installed capacity, the reduction of the round-trip efficiency, and the limits on the number of charging/discharging cycles are aspects that need to be taken into account in techno-economic analyses. The modeling of these degradation phenomena becomes crucial when predictions over long time horizons (capacity expansion) are made. For each one of these phenomena, a brief description is given, and some figures to be implemented in the HERON optimization algorithm are presented.

25 ENERGY STORAGE↗

Evaluating an Eco-Cooperative Automated Control System

The paper evaluates an Eco-Cooperative Automated Control (Eco-CAC) system on a large-scale network considering a combination of internal combustion engine vehicles (ICEVs), hybrid electric vehicles (HEVs), and battery-only electric vehicles (BEVs) in a microscopic traffic simulation environment. We used a novel integrated control system that: (1) routes ICEVs, HEVs, and BEVs in a fuel/energy-efficient manner; (2) selects vehicle speeds based on anticipated traffic network evolution; (3) minimizes vehicle fuel/energy consumption near signalized intersections; and (4) intelligently modulates the longitudinal motion of vehicles along freeways within a cooperative platoon to minimize fuel/energy consumption. The study tested the system using the INTEGRATION software on the Los Angeles (LA), U.S., downtown network for three different demand levels: no congestion, mild congestion, and heavy congestion. The results demonstrated that the Eco-CAC system effectively reduces vehicle fuel and energy consumption, travel time, total delay, and stopped delay in heavily congested conditions. However, different vehicle compositions produced different results. In particular, the maximum energy consumption savings for BEVs (36.9%) for a current vehicle composition occurred at a 10% market penetration rate (MPR) of connected automated vehicles (CAVs) in mild congestion, while the maximum savings for a future vehicle composition (35.5%) occurred at a 50% CAV MPR in no congestion. The system reduced fuel consumption for ICEVs and HEVs by up to 5.4% and 6.3% at a 25% CAV MPR in heavy congestion for current and future vehicle compositions, respectively. However, the system increased total fuel consumption by up to 4.6% at a 50% CAV MPR in no congestion for a current vehicle composition. The study demonstrates that the effectiveness of the Eco-CAC system depends on traffic conditions, including congestion level, network configuration, CAV MPR, and vehicle composition.

Engineering↗

Integrated Heat Exchanger/Thermal Energy Storage System for CSP Plants

The research and development during the project focused on the design and optimization of an integrated heat exchanger/thermal energy storage (HX/TES) system, the charging and discharging performance of the developed HX/TES system, and the experimental investigation of lab-scale prototypes based on the full-scale system.

42 ENGINEERING↗

NREL CITIES Support (CRADA CRD-14-00558 Final Report)

The Technical University of Denmark has received a Grant from the Danish Council for Strategic Research for the project "CITIES - Centre for IT-Intelligent Energy Systems in Cities", a strategic research centre, which involves industrial partners and universities. The Alliance for Sustainable Energy, LLC will participate with DTU as an industrial partner in "CITIES" under this Cooperative Research and Development Agreement (CRADA). The Centre for IT based Intelligent Energy Systems in Cities (CITIES) Project is a Danish national research center focused on work in building short-term operational integrated energy system models that feed longer term plam1ing models, considering the spatio-temporal variations, interactions, dynamics and stochastics in the energy system, from production to consumption. CITIES will harness the extensive expertise and experience of its industrial and academic partners to conduct meaningful research with tangible outputs, including a roadmap to a fossil free future. Decision support tools will be developed to inform stakeholders of the impact of investment, control and policy measures and to identify further opportunities for energy system efficiency. Dissemination and transferring knowledge is a key value to this CRADA, and the use of results by Danish policymakers, industry and society is vital. All participants in the Centre for IT based Intelligent Energy Systems in Cities (CITIES) Project are therefore encouraged to use all means to communicate their findings to society. Wherever possible, and compatible with applicable intellectual property regulations, publications should be produced and disseminated under Open Science, Data, Source and Access principles.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of the INL Thermal Energy Distribution System (TEDS) in the Modelica Eco-System for Validation and Verification

This report provides an overview on the development of the Thermal Energy Distribution System (TEDS) in the Modelica process model eco-system at Idaho National Laboratory as part of the integrated energy system initiative. Model development has led to the creation of a dynamic process model of the experimental TEDS facility housed within the Engineering Science Laboratory (ESL) at INL. The model was then used during the pre-construction phase of the experimental effort to inform experimental design (insulation requirements, bypass line placement, expected performance of components) and to test innovative control schemes prior to the initial operation. The TEDS model developed in Modelica includes the primary components of the TEDS experimental unit including: a 200kW Chromalox heater, a single-tank packed bed thermal energy storage system filled with 0.125 inch Alumina (Al 2 O 3 ), an ethylene-glycol to Therminol-66 heat exchanger, system piping, six control valves, and all associated temperature, pressure, and mass flow sensors. The model does not include nitrogen fill gas tanks, or associated overfill tanks, as these are not part of standard system control. Two simulation sets were run. The first is a five-hour test that operates as a shakedown test for the facility. This simulation puts the facility through all five potential operating modes and showcases the ability of valving, control sensors, and component controllers to meet the system demands. The second case imposes a typical summer day demand on the system from a region with mixed commercial and residential electrical needs where the generator alone cannot meet peak demand but instead requires the thermal storage unit to act as a peaking unit. Over the course of the fifteen-hour discharge cycle heat losses account for a heat loss of approximately 15°C in outlet temperature. Such heat losses would lead to a decrease in overall system efficiency and may lead to additional design changes for such designs in the future that may include a topping heater. Through commencement of this work, a systems level model of TEDS with associated control systems, sensors, piping diameters, and component capabilities has been created. This model has been utilized in the pre-experimental phase to inform system design, insulation thicknesses, and potential control schemes to operate the system effectively and safely. Once TEDS begins operation, this model will be refined, tuned, and used for validation and verification purposes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Casing Annulus Monitoring of CO 2 Injection Using Wireless Autonomous Distributed Sensor Networks

Effective and secure carbon subsurface storage, involving the deep underground injection of CO 2 into geological formations where it is permanently trapped, is paramount to mitigating CO 2 emissions (Figure I). Ensuring the integrity of these storage sites and detecting potential leakage through the casing annulus necessitates robust monitoring. This work provides the first integrated demonstration of a wireless casing-annulus monitoring architecture that can operate in highly attenuating cement-brine environments relevant to CO 2 storage. This project focused on developing and validating a novel sensor system for integration with autonomous monitoring near the cement reservoir interface. The goal was a fully integrated Technology Readiness Level (TRL) 4/5 field validation of a distributed wireless intelligent sensor system providing real-time, direct subsurface formation measurements to enhance fluid movement monitoring in the cemented casing annulus. Achieving this objective required the development and integration of 1) wireless autonomous microsensor technology by California Institute of Technology (Caltech); 2) sensor packaging and emplacement technology by Research Triangle Institute (RTI); and 3) smart well completions using wireless active casing collars and NOV pipe by the Sandia National Lab (SNL). The collaboration with the Caltech team in this project aimed to develop millimeter-scale radio frequency identification (RFID) sensors capable of detecting CO 2 , pH, and/or methane levels. These sensors are engineered to be impervious to fluids, allowing them to be mixed with cement and installed within the casing annulus. They operate using RFID protocols at frequencies of 902–928 MHz for both power and communication. A Sandia National Laboratories’ team engaged their expertise in the development of a Smart Collar system designed for the wireless data collection from these RFID sensors embedded in the cement annulus and transmission of this information to the ground surface via IntelliPipe/IntelliServ NOV drill pipe. This is accomplished through inductive coupling at the collar, which facilitates data transfer through each segment of the pipe. Because the system cannot transmit a direct current signal to power the Smart Collar, both power and communication were implemented using alternating current and electromagnetic signals at varying frequencies. Furthermore, the developed microsensor technology had to be demonstrated and validated in comparison with reference transducer measurements in a field test site at The University of Texas at Austin (UT-Austin). Although the full sensor suite did not reach field-deployment readiness, the system-level integration achieved in this project establishes a validated pathway for future incorporation of advanced microsensors.

47 OTHER INSTRUMENTATION↗

HERON

HERON is a modeling toolset and plugin for RAVEN to accelerate stochastic technoeconomic assessment of the economic viability of various grid-energy system configurations, especially with application to electrical grids and integrated energy systems (IES). The frameworks enabling this toolset are INL's RAVEN and its TEAL plugin. The toolset includes automated RAVEN workflow generation tools for performing stochastic analysis and optimization driven by technoeconomic factors. The workflows generated employ RAVEN for parametric or optimizing study of grid component characteristics, and again for stochastic sampling of regulated and deregulated markets, load, and weather histories. The toolset further provides methods for economically-optimal dispatch of system components given the stochastic samples of market, load, and weather histories. The toolset allows assembling of existing and new models through the RAVEN interface to the Modelica process modeling language.

Talbot, PaulW↗

Low-cost Retrofit Kit for Integral Reciprocating Compressors (IRCs) to Reduce Emissions and Enhance Efficiency

Methane emissions from natural gas engines within the oil and gas industry pose a significant environmental challenge, contributing approximately 34.1 MMTCO2 eq to the total of 239 MMTCO2 eq of methane emissions in 2021, according to the EPA report. In response to this pressing issue, a collaborative effort involving the University of Oklahoma and key industry partners—WAGO Automation, Mid Continental Rental, Elipsa, and Perscient—has resulted in the development of a retrofit kit designed to reduce emissions from integral reciprocating compressors (IRCs), which are integrated compressors and engines. The retrofit kit developed comprises an Air Management System (AMS), Integrated Sensors, and a Cloud-Connected Control Unit with Graphical User Interface (GUI)/Human-Machine Interface (HMI). This solution enhances operational efficiency, reduces emissions, and expands the operational envelope of IRCs in the natural gas industry. The project successfully completed all tasks, including the installation of a full-size IRC at a designated site in Oklahoma, the development of an optimized AMS, integration of sensors, and implementation of a data acquisition system. Significant achievements include a notable reduction in CH 4 emissions, up to 84% at specific loads, and the successful deployment of the retrofit kit in diverse field conditions. The system's capabilities were enhanced through the creation of a feedback control algorithm for the AMS using a correlation matrix illustrating relationships between engine parameters, and the design of a predictive and preventive maintenance platform. The project concluded with the deployment of the entire retrofit kit to another location, confirming its effectiveness in reducing emissions and enhancing IRC performance. The comprehensive solution offers valuable benefits for IRCs, making them invaluable assets in the natural gas industry.

03 NATURAL GAS↗

Renewable Integration in Hybrid ac-dc Systems using Multi-port Autonomous Reconfigurable Solar power plant (MARS)

To increase inertia and improve primary frequency response of future grids, grid-forming inverters connecting PV to grid and energy storage systems (ESSs) are likely to play an important role. Moreover, high-voltage direct current (HVdc) links will also be an enabler to transfer remote PV generation and for improved grid stability. That is, with increased penetration of PV, discrete development of PV and ESS connecting to transmission ac grid and HVdc links is one of the solutions for stable operation of grid. Here, an integrated concept for integration of PV and ESS to transmission ac grid and HVdc links is proposed that is named as multi-port autonomous reconfigurable solar power plant (MARS). The proposed integrated development reduces the cost associated with respect to discrete development of PV-ESS systems connecting to transmission ac grid and HVdc links. The integrated development incorporates advanced control methods to provide inertial and primary frequency response, reactive power support, and transient stability to manage PV and ESS resources. In this paper, high-fidelity switched system model of the integrated system and grids are developed and detailed simulation results are provided to showcase the stable operation of the integrated system and provision of grid support functions.

14 SOLAR ENERGY↗

Large Language Models (LLMs) for Energy Systems Research

The integration of Large Language Models (LLMs) in energy systems research promises transformative results, as demonstrated in this work, particularly in the realms of information retrieval and legal document analysis. We have developed a chat-based interface, specifically designed to query an extensive corpus of technical reports from the National Renewable Energy Laboratory (NREL). This interface capitalizes on the natural language processing capabilities of LLMs, providing future consumers of NREL research with a user-friendly platform to access and extract valuable information from technical documents, thus enhancing the dissemination of research to the public. In addition to information retrieval, we have employed LLMs to extract renewable energy siting ordinances from a variety of legal documents, a task traditionally driven by significant human labor. This automated extraction not only supports the ongoing development of the high-impact NREL siting ordinance database but also ensures the database's accuracy and comprehensiveness. Crucially, we have augmented the performance of LLMs through the integration of a decision tree framework, resulting in a substantial improvement in extraction accuracy. Comparative analysis with manual efforts has shown that this approach not only rivals but also significantly surpasses human accuracy, heralding increased reliability in legal document analysis for energy systems research. To democratize access to these advancements and foster collaborative research, we introduce the "Energy Language Model" (ELM), an open-source software package. ELM encapsulates the methodologies and tools developed in this work, providing researchers and practitioners with a robust toolkit to conduct similar analyses within their respective domains. Through these contributions, this work underscores the immense potential of LLMs in revolutionizing energy systems research, improving accuracy, efficiency, and accessibility in the field.

automation↗

Meso-Scale Electrodynamic Coupling of the Earth Magnetosphere-Ionosphere System

Within the fully integrated magnetosphere-ionosphere system, many electrodynamic processes interact with each other. We review recent advances in understanding three major meso-scale coupling processes within the system: the transient field-aligned currents (FACs), mid-latitude plasma convection, and auroral particle precipitation. (1) Transient FACs arise due to disturbances from either dayside or nightside magnetosphere. As the interplanetary shocks suddenly compress the dayside magnetosphere, short-lived FACs are induced at high latitudes with their polarity successively changing. Magnetotail dynamics, such as substorm injections, can also disturb the current structures, leading to the formation of substorm current wedges and ring current disruption. (2) The mid-latitude plasma convection is closely associated with electric fields in the system. Recent studies have unraveled some important features and mechanisms of subauroral fast flows. (3) Charged particles, while drifting around the Earth, often experience precipitating loss down to the upper atmosphere, enhancing the auroral conductivity. Recent studies have been devoted to developing more self-consistent geospace circulation models by including a better representation of the auroral conductance. It is expected that including these new advances in geospace circulation models could promisingly strengthen their forecasting capability in space weather applications. The remaining challenges especially in the global modeling of the circulation system are also discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Program Review: Thermal Systems Pillar

Program Review: Thermal Systems Pillar Slides go over the 3 year plan for the integrated energy systems program DETAIL. The plan goes into connections between the DETAIL components and plans for future integration.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Economically Viable Intermediate to Long Duration Hydrogen Energy Storage Solutions for Fossil Fueled Assets

This report was prepared as an account of work sponsored by the Office of Fossil Energy and Carbon Management of U.S. Department of Energy under Funding Opportunity Announcement Number DE-FOA-0002332 “Energy Storage for Fossil Power Generation”. The work aimed to explore and advance an innovative hydrogen energy storage system – the synergistically integrated hydrogen energy storage system (SIHES) – that has the following characteristics: • Compatible with existing or new coal and gas fuel electricity generation units, • best suited for intermediate to long duration energy storage, from 12 hours to weeks even months, and • capable of storing energy at the utility scale – hundreds of MWh to GWh energy storage with power output level in tens to hundreds of MW. Preliminary front-end engineering design (Pre-FEED) studies was carried out to develop and refine a site-specific SIHES as peaking power generation units (so named as HyPeaker) as the first market entry point, to demonstrate both the technical feasibility and the economic viability to integrate the HyPeaker “within the fence” of a fossil power plant. This specific site was TVA’s Johnsonville Combustion Turbine Plant. The HyPeaker was designed and engineered to integrate with a 60MW aeroderivative gas turbine unit already available at TVA’s Johnsonville site. This site-specific HyPeaker consists of an alkaline electrolyzer to produce hydrogen from CO 2 free electricity sources, an innovative low-cost high-pressure hydrogen storage system (Big-Ton) and the aero gas turbine to generate electricity using blend of hydrogen and natural gas. A holistic system level technoeconomic analysis tool specific to HyPeaker was developed to optimize the engineering design of the Johnsonville site-specific HyPeaker for cost and performance. The optimal design and specification of the Johnsonville site-specific HyPeaker are the following: • Alkaline electrolyzer: 3MW • Big-Ton storage vessel: 11,000kg H 2 at 3000psi. • 4-stage diaphragm hydrogen compressor: 55kg-H 2 /hr from 150psi to 3000psi. The HyPeaker is designed to provide sufficient hydrogen for 90% continuous operation of the HyPeaker. All major components have design life of 30 years. The capex of HyPeaker is estimated at $\$$7.1M. This included $\$$1.5M for the electrolyzer, $\$$5.6M for the storage vessel and compressor. The cost of aero gas turbine was included as it is already available at the site. Key findings are: • HyPeaker can be designed, manufactured, installed and integrated with the fossil power plants, with sub-systems and components commercially available on the market today, even when it is scaled up to an order of magnitude larger than the one at the Johnsonville site. HyPeaker is a technologically viable solution to cover a wide range of energy storage duration needs, from daily peaking operation to seasonal shifting for fossil fueled assets. • The cost advantage of SCCV based Big-Ton H 2 storage vessel made it possible to “oversize” the H 2 storage subsystem to achieve overall system level cost optimization. The benefits are two-fold. First, it allows to significantly reduce the capacity and cost of electrolyzer by spreading H 2 production over a much longer period of time when the fuel cost for electricity production is low. Second, it allows to balance the hydrogen production and usage shift over weeks to months to meet the peak demands. As such, the capital cost of HyPeaker system using the Big-Ton was less than half of the cost of a system with today’s steel tube based H 2 storage system. The HyPeaker has even better cost advantage Li-ion battery based energy storage system. The estimated capital cost of Li-Ion battery system would be at $\$$38M, under the same projected 20-year electricity generation profile of the Johnsonville site. This is over 5 times more expensive than the HyPeaker system. • Since industry scale energy storage systems do not have 100% energy conversion and storage efficiency, energy storage systems using fossil fuel generated electricity would increase the CO 2 emission. This is particularly the case for HyPeaker due to its low round trip efficiency. Therefore, a more sensible solution would be to the excessive or curtailed electricity from CO 2 emission free sources such as solar farms, wind farms or nuclear power plants, to produce hydrogen, and integrate them with the HyPeaker. Electricity from TVA’s nuclear power plants was used for the Johnsonville HyPeaker. • The economic viability of HyPeaker is expected to be further improved when global supply chains are taken into consideration. For the same Johnsonville site specific HyPeaker, the capex would be reduced to ~$\$$3.6M from ~$\$$7.1M, and the added LCOE is reduced to ~$\$$85/MWh. With the bipartisan Infrastructure Investment and Jobs Act, the cost of domestically produced HyPeaker sub-systems would be at the level of today’s global suppliers. Since the peaking units generally operate at peak usage period, thereby demanding higher price, the projected $\$$85/MWh LCOE would be within the realm of financial viability for utility operators.

08 HYDROGEN↗

Integration of a DER Management System in Riverside. Final report

The tasks in this project covered various aspects, including algorithm development, algorithm integration into a commercial Active Network Management (ANM) platform, hardware-in-the-loop (HIL) testing in an industry-standard testing platform, pilot demonstration in Riverside, California, and also cost and benefit analysis. The DERMS platform in this project can host different algorithms developed on different platforms (e.g., MATLAB and Python) and it can interact with different hardware devices (e.g., different PV inverters, battery inverters, and different sensors). The DER control solution are based on an advanced model-free, layered, and clustered DER control paradigm. At the core of the DER control algorithms was the concept of Extremum Seeking (ES), which is a model-free probing-based control technique. The ES-based control algorithms were tested on major real-world inverters; both individually and in a cluster. It was shown that even legacy equipment (or when paired with a few additional advanced equipment) can support such advanced control. The monitoring algorithms utilize a heterogeneous set of legacy and advanced sensor measurements, such as behind-the-meter DER sensors, distribution-level Phase Measurement Units, distribution-substation Supervisory Control and Data Acquisition (SCADA), and line current sensors, with their limited availability; in order to infer practical network conditions. Sensor data are utilized to achieve resource forecasting, phase identification, and distribution system state estimation. The technology that was developed and demonstrated in this project could be transformational to utilities, including the smaller municipal utilities such as in Riverside, which may not have the resources to deploy advanced distribution system and DERMS solutions in order to support high penetration of solar power integration. This project created a real-world prototype to provide utilities with an assessment of smart grid monitoring and control technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Illinois Compressed Air Energy Storage

Compressed Air Storage Energy (CAES) is one of the few mid- technology readiness level (TRL) energy storage technologies that can address the long-duration infrastructure needed for dealing with variable electric output from renewable energy sources and be reliable backup source for replacing natural gas during supply interruptions. In CAES the goal is to capture and store compressed air in subsurface sedimentary strata when off-peak power is available, or there is a need for grid balancing. The stored high-pressure air is returned to the surface and used to power turbines during reductions in either renewable energy or supply issues with fossil fuels. The Illinois CAES project evaluates the feasibility of capturing surplus electrical energy from renewable sources and off-peak energy at a fossil fuel power plant at the University of Illinois Urbana - Champaign (UIUC) campus. The UIUC Abbott Power Plant uses natural gas and coal to generate electricity (capacity: 35 MWe by coal and 49 MWe by NG). UIUC receives additional electricity from on campus solar farm, and off-campus wind farm. Also, UIUC offsets electricity usage by integrating geothermal energy systems into building heating Also, UIUC offsets steam, hot and chilled water usage by integrating geothermal energy systems into building heating and cooling systems. Furthermore, the two UIUC solar farms (Solar Farm 1 is 21 acres and Solar Farm 2 is 54 acres) to generate 4.68 megawatts (MW) and 12.1 MW, respectively. Campus receives 8.6% of the wind-generated electricity from the Rail Splitter Wind Farm. The project objectives were to design an integrated system to 1) capture surplus electrical energy from renewable sources and the Abbott Power Plant using a CAES system, 2) store both the compressed air and the thermal heat generated by compression in the subsurface as part of an adiabatic system, 3) simulate the movement of the air and heat in the subsurface, 4) recover the compressed air and stored thermal heat to rotate turbine generators during sustained interruption due to weather events or fossil fuel disruptions.

03 NATURAL GAS↗