Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IMAGE PROCESSING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

A short-scan reconstruction for cone-beam CT using shift-invariant FBP and equal weighting

A 3D reconstruction formula has been derived for a circular cone-beam (CB) short scan using 1D shift-invariant filtering, CB backprojection, and equal weighting. By first converting the divergent projections to parallel projections, we analyze the circular CB data using the classic central slice theorem. The sampling density in Fourier space is investigated and 1D shift-invariant filtering before backprojection can be used to compensate for the nonuniformity. The final formula consists of a conventional FDK reconstruction and a correction term using differential backprojection and the 1D Hilbert transform in the image domain. On a full scan, the approach reduces to the FDK algorithm, while for a short scan, the CB artifacts are suppressed by the second term. This algorithm outperforms the modified FDK algorithm with Parker's weighting, as illustrated by computer simulations and experimental results. Due to its shift-invariant filtered-backprojection structure, the proposed algorithm is implemented efficiently, and requires a simple adaptation of the FDK algorithm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A three-dimensional statistical approach to improved image quality for multislice helical CT

Multislice helical computed tomography scanning offers the advantages of faster acquisition and wide organ coverage for routine clinical diagnostic purposes. However, image reconstruction is faced with the challenges of three-dimensional cone-beam geometry, data completeness issues, and low dosage. Of all available reconstruction methods, statistical iterative reconstruction (IR) techniques appear particularly promising since they provide the flexibility of accurate physical noise modeling and geometric system description. In this paper, we present the application of Bayesian iterative algorithms to real 3D multislice helical data to demonstrate significant image quality improvement over conventional techniques. We also introduce a novel prior distribution designed to provide flexibility in its parameters to fine-tune image quality. Specifically, enhanced image resolution and lower noise have been achieved, concurrently with the reduction of helical cone-beam artifacts, as demonstrated by phantom studies. Clinical results also illustrate the capabilities of the algorithm on real patient data. Although computational load remains a significant challenge for practical development, superior image quality combined with advancements in computing technology make IR techniques a legitimate candidate for future clinical applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Soft-tissue detectability in cone-beam CT: Evaluation by 2AFC tests in relation to physical performance metrics

Soft-tissue detectability in cone-beam computed tomography (CBCT) was evaluated via two-alternative forced-choice (2AFC) tests. Investigations included the dependence of detectability on radiation dose, the influence of the asymmetric three-dimensional (3D) noise-power spectrum (NPS) in axial and sagittal or coronal planes, and the effect of prior knowledge on detectability. Custom-built phantoms ({approx}15 cm diameter cylinders) containing soft-tissue-simulating spheres of variable contrast and diameter were imaged on an experimental CBCT bench. The proportion of correct responses (P{sub corr}) in 2AFC tests was analyzed as a figure of merit, ideally equal to the area under the receiver operating characteristic curve. P{sub corr} was evaluated as a function of the sphere diameter (1.6-12.7 mm), contrast (20-165 HU), dose (1-7 mGy), plane of visualization (axial/sagittal), apodization filter (Hanning and Ram-Lak), and prior knowledge provided to the observer [ranging from stimulus known exactly (SKE) to stimulus unknown (SUK)]. Detectability limits were characterized in terms of the dose required to achieve a given level of P{sub corr} (e.g., 70%). For example, a 20 HU stimulus of diameter down to {approx}6 mm was detected with P{sub corr} 70% at dose {>=}2 mGy. Detectability tended to be greater in axial than in sagittal planes, an effect amplified by sharper apodization filters in a manner consistent with 3D NPS asymmetry. Prior knowledge had a marked influence on detectability - e.g., P{sub corr} for a {approx}6 mm(20 HU) sphere was {approx}55%-65% under SUK conditions, compared to {approx}70%-85% for SKE conditions. Human observer tests suggest practical implications for implementation of CBCT: (i) Detectability limits help to define minimum-dose imaging techniques for specific imaging tasks; (ii) detectability of a given structure can vary between axial and sagittal/coronal planes, owing to the spatial-frequency content of the 3D NPS in relation to the imaging task; and (iii) performance under SKE conditions (e.g., image guidance tasks in which lesion characteristics are known) is maintained at a lower dose than in SUK conditions (e.g., diagnostic tasks in which lesion characteristics are unknown)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A dual-stage method for lesion segmentation on digital mammograms

Mass lesion segmentation on mammograms is a challenging task since mass lesions are usually embedded and hidden in varying densities of parenchymal tissue structures. In this article, we present a method for automatic delineation of lesion boundaries on digital mammograms. This method utilizes a geometric active contour model that minimizes an energy function based on the homogeneities inside and outside of the evolving contour. Prior to the application of the active contour model, a radial gradient index (RGI)-based segmentation method is applied to yield an initial contour closer to the lesion boundary location in a computationally efficient manner. Based on the initial segmentation, an automatic background estimation method is applied to identify the effective circumstance of the lesion, and a dynamic stopping criterion is implemented to terminate the contour evolution when it reaches the lesion boundary. By using a full-field digital mammography database with 739 images, we quantitatively compare the proposed algorithm with a conventional region-growing method and an RGI-based algorithm by use of the area overlap ratio between computer segmentation and manual segmentation by an expert radiologist. At an overlap threshold of 0.4, 85% of the images are correctly segmented with the proposed method, while only 69% and 73% of the images are correctly delineated by our previous developed region-growing and RGI methods, respectively. This resulting improvement in segmentation is statistically significant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved dynamic-programming-based algorithms for segmentation of masses in mammograms

In this paper, two new boundary tracing algorithms for segmentation of breast masses are presented. These new algorithms are based on the dynamic programming-based boundary tracing (DPBT) algorithm proposed in Timp and Karssemeijer, [S. Timp and N. Karssemeijer, Med. Phys. 31, 958-971 (2004)] The DPBT algorithm contains two main steps: (1) construction of a local cost function, and (2) application of dynamic programming to the selection of the optimal boundary based on the local cost function. The validity of some assumptions used in the design of the DPBT algorithm is tested in this paper using a set of 349 mammographic images. Based on the results of the tests, modifications to the computation of the local cost function have been designed and have resulted in the Improved-DPBT (IDPBT) algorithm. A procedure for the dynamic selection of the strength of the components of the local cost function is presented that makes these parameters independent of the image dataset. Incorporation of this dynamic selection procedure has produced another new algorithm which we have called ID{sup 2}PBT. Methods for the determination of some other parameters of the DPBT algorithm that were not covered in the original paper are presented as well. The merits of the new IDPBT and ID{sup 2}PBT algorithms are demonstrated experimentally by comparison against the DPBT algorithm. The segmentation results are evaluated with base on the area overlap measure and other segmentation metrics. Both of the new algorithms outperform the original DPBT; the improvements in the algorithms performance are more noticeable around the values of the segmentation metrics corresponding to the highest segmentation accuracy, i.e., the new algorithms produce more optimally segmented regions, rather than a pronounced increase in the average quality of all the segmented regions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feature-based characterization of motion-contaminated calcified plaques in cardiac multidetector CT

In coronary calcium scoring, motion artifacts affecting calcified plaques are commonly characterized using descriptive terms, which incorporate an element of subjectivity in their interpretations. Quantitative indices may improve the objective characterization of these motion artifacts. In this paper, an automated method for generating 12 quantitative indices, i.e., features that characterize the motion artifacts affecting calcified plaques, is presented. This method consists of using the rapid phase-correlated region-of-interest (ROI) tracking algorithm for reconstructing ROI images of calcified plaques automatically from the projection data obtained during a cardiac scan, and applying methods for extracting features from these images. The 12 features include two dynamic, six morphological, and four intensity-based features. The two dynamic features are three-dimensional (3D) velocity and 3D acceleration. The six morphological features include edge-based volume, threshold-based volume, sphericity, irregularity, average margin gradient, and variance of margin gradient. The four intensity-based features are maximum intensity, mean intensity, minimum intensity, and standard deviation of intensity. The 12 features were extracted from 54 reconstructed sets of simulated four-dimensional images from the dynamic NCAT phantom involving six calcified plaques under nine heart rate/multi-sector gating combinations. In order to determine how well the 12 features correlated with a plaque motion index, which was derived from the trajectory of the plaque, partial correlation coefficients adjusted for heart rate, number of gated sectors, and mean feature values of the six plaques were calculated for all 12 features. Features exhibiting stronger correlations (|r| set-membership sign [0.60,1.00]) with the motion index were 3D velocity, maximum intensity, and standard deviation of intensity. Features demonstrating stronger correlations (|r| set-membership sign [0.60,1.00]) with other features mostly involved intensity-based features. Edge-based volume/irregularity and average margin gradient/variance of margin gradient were the only two feature pairs out of 12 with stronger correlations that did not involve intensity-based features. Automatically extracted features of the motion artifacts affecting calcified plaques in cardiac computed tomography images potentially can be used to develop models for predicting image assessability with respect to motion artifacts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automated volume analysis of head and neck lesions on CT scans using 3D level set segmentation

The authors have developed a semiautomatic system for segmentation of a diverse set of lesions in head and neck CT scans. The system takes as input an approximate bounding box, and uses a multistage level set to perform the final segmentation. A data set consisting of 69 lesions marked on 33 scans from 23 patients was used to evaluate the performance of the system. The contours from automatic segmentation were compared to both 2D and 3D gold standard contours manually drawn by three experienced radiologists. Three performance metric measures were used for the comparison. In addition, a radiologist provided quality ratings on a 1 to 10 scale for all of the automatic segmentations. For this pilot study, the authors observed that the differences between the automatic and gold standard contours were larger than the interobserver differences. However, the system performed comparably to the radiologists, achieving an average area intersection ratio of 85.4% compared to an average of 91.2% between two radiologists. The average absolute area error was 21.1% compared to 10.8%, and the average 2D distance was 1.38 mm compared to 0.84 mm between the radiologists. In addition, the quality rating data showed that, despite the very lax assumptions made on the lesion characteristics in designing the system, the automatic contours approximated many of the lesions very well.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stereotactic mammography imaging combined with 3D US imaging for image guided breast biopsy

Stereotactic X-ray mammography (SM) and ultrasound (US) guidance are both commonly used for breast biopsy. While SM provides three-dimensional (3D) targeting information and US provides real-time guidance, both have limitations. SM is a long and uncomfortable procedure and the US guided procedure is inherently two dimensional (2D), requiring a skilled physician for both safety and accuracy. The authors developed a 3D US-guided biopsy system to be integrated with, and to supplement SM imaging. Their goal is to be able to biopsy a larger percentage of suspicious masses using US, by clarifying ambiguous structures with SM imaging. Features from SM and US guided biopsy were combined, including breast stabilization, a confined needle trajectory, and dual modality imaging. The 3D US guided biopsy system uses a 7.5 MHz breast probe and is mounted on an upright SM machine for preprocedural imaging. Intraprocedural targeting and guidance was achieved with real-time 2D and near real-time 3D US imaging. Postbiopsy 3D US imaging allowed for confirmation that the needle was penetrating the target. The authors evaluated 3D US-guided biopsy accuracy of their system using test phantoms. To use mammographic imaging information, they registered the SM and 3D US coordinate systems. The 3D positions of targets identified in the SM images were determined with a target localization error (TLE) of 0.49 mm. The z component (x-ray tube to image) of the TLE dominated with a TLE{sub z} of 0.47 mm. The SM system was then registered to 3D US, with a fiducial registration error (FRE) and target registration error (TRE) of 0.82 and 0.92 mm, respectively. Analysis of the FRE and TRE components showed that these errors were dominated by inaccuracies in the z component with a FRE{sub z} of 0.76 mm and a TRE{sub z} of 0.85 mm. A stereotactic mammography and 3D US guided breast biopsy system should include breast compression for stability and safety and dual modality imaging for target localization. The system will provide preprocedural x-ray mammography information in the form of SM imaging along with real-time US imaging for needle guidance to a target. 3D US imaging will also be available for targeting, guidance, and biopsy verification immediately postbiopsy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Computer-aided detection of interstitial abnormalities in chest radiographs using a reference standard based on computed tomography

A computer-aided detection (CAD) system is presented for the localization of interstitial lesions in chest radiographs. The system analyzes the complete lung fields using a two-class supervised pattern classification approach to distinguish between normal texture and texture affected by interstitial lung disease. Analysis is done pixel-wise and produces a probability map for an image where each pixel in the lung fields is assigned a probability of being abnormal. Interstitial lesions are often subtle and ill defined on x-rays and hence difficult to detect, even for expert radiologists. Therefore a new, semiautomatic method is proposed for setting a reference standard for training and evaluating the CAD system. The proposed method employs the fact that interstitial lesions are more distinct on a computed tomography (CT) scan than on a radiograph. Lesion outlines, manually drawn on coronal slices of a CT scan of the same patient, are automatically transformed to corresponding outlines on the chest x-ray, using manually indicated correspondences for a small set of anatomical landmarks. For the texture analysis, local structures are described by means of the multiscale Gaussian filter bank. The system performance is evaluated with ROC analysis on a database of digital chest radiographs containing 44 abnormal and 8 normal cases. The best performance is achieved for the linear discriminant and support vector machine classifiers, with an area under the ROC curve (A{sub z}) of 0.78. Separate ROC curves are built for classification of abnormalities of different degrees of subtlety versus normal class. Here the best performance in terms of A{sub z} is 0.90 for differentiation between obviously abnormal and normal pixels. The system is compared with two human observers, an expert chest radiologist and a chest radiologist in training, on evaluation of regions. Each lung field is divided in four regions, and the reference standard and the probability maps are converted into region scores. The system performance does not significantly differ from that of the observers, when the perihilar regions are excluded from evaluation, and reaches A{sub z}=0.85 for the system, with A{sub z}=0.88 for both observers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification of accuracy of the automated nonlinear image matching and anatomical labeling (ANIMAL) nonlinear registration algorithm for 4D CT images of lung

The performance of the ANIMAL (Automated Nonlinear Image Matching and Anatomical Labeling) nonlinear registration algorithm for registration of thoracic 4D CT images was investigated. The algorithm was modified to minimize the incidence of deformation vector discontinuities that occur during the registration of lung images. Registrations were performed between the inhale and exhale phases for five patients. The registration accuracy was quantified by the cross-correlation of transformed and target images and distance to agreement (DTA) measured based on anatomical landmarks and triangulated surfaces constructed from manual contours. On average, the vector DTA between transformed and target landmarks was 1.6 mm. Comparing transformed and target 3D triangulated surfaces derived from planning contours, the average target volume (GTV) center-of-mass shift was 2.0 mm and the 3D DTA was 1.6 mm. An average DTA of 1.8 mm was obtained for all planning structures. All DTA metrics were comparable to inter observer uncertainties established for landmark identification and manual contouring.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimization of reference library used in content-based medical image retrieval scheme

Building an optimal image reference library is a critical step in developing the interactive computer-aided detection and diagnosis (I-CAD) systems of medical images using content-based image retrieval (CBIR) schemes. In this study, the authors conducted two experiments to investigate (1) the relationship between I-CAD performance and size of reference library and (2) a new reference selection strategy to optimize the library and improve I-CAD performance. The authors assembled a reference library that includes 3153 regions of interest (ROI) depicting either malignant masses (1592) or CAD-cued false-positive regions (1561) and an independent testing data set including 200 masses and 200 false-positive regions. A CBIR scheme using a distance-weighted K-nearest neighbor algorithm is applied to retrieve references that are considered similar to the testing sample from the library. The area under receiver operating characteristic curve (A{sub z}) is used as an index to evaluate the I-CAD performance. In the first experiment, the authors systematically increased reference library size and tested I-CAD performance. The result indicates that scheme performance improves initially from A{sub z}=0.715 to 0.874 and then plateaus when the library size reaches approximately half of its maximum capacity. In the second experiment, based on the hypothesis that a ROI should be removed if it performs poorly compared to a group of similar ROIs in a large and diverse reference library, the authors applied a new strategy to identify 'poorly effective' references. By removing 174 identified ROIs from the reference library, I-CAD performance significantly increases to A{sub z}=0.914 (p<0.01). The study demonstrates that increasing reference library size and removing poorly effective references can significantly improve I-CAD performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image quality and localization accuracy in C-arm tomosynthesis-guided head and neck surgery

The image quality and localization accuracy for C-arm tomosynthesis and cone-beam computed tomography (CBCT) guidance of head and neck surgery were investigated. A continuum in image acquisition was explored, ranging from a single exposure (radiograph) to multiple projections acquired over a limited arc (tomosynthesis) to a full semicircular trajectory (CBCT). Experiments were performed using a prototype mobile C-arm modified to perform 3D image acquisition (a modified Siemens PowerMobil). The tradeoffs in image quality associated with the extent of the source-detector arc ({theta}{sub tot}), the number of projection views, and the total imaging dose were evaluated in phantom and cadaver studies. Surgical localization performance was evaluated using three cadaver heads imaged as a function of {theta}{sub tot}. Six localization tasks were considered, ranging from high-contrast feature identification (e.g., tip of a K-wire pointer) to more challenging soft-tissue delineation (e.g., junction of the hard and soft palate). Five head and neck surgeons and one radiologist participated as observers. For each localization task, the 3D coordinates of landmarks pinpointed by each observer were analyzed as a function of {theta}{sub tot}. For all tomosynthesis angles, image quality was highest in the coronal plane, whereas sagittal and axial planes exhibited a substantial decrease in spatial resolution associated with out-of-plane blur and distortion. Tasks involving complex, lower-contrast features demonstrated steeper degradation with smaller tomosynthetic arc. Localization accuracy in the coronal plane was correspondingly high, maintained to <3 mm down to {theta}{sub tot}{approx}30 deg. , whereas sagittal and axial localization degraded rapidly below {theta}{sub tot}{approx}60 deg. . Similarly, localization precision was better than {approx}1 mm within the coronal plane, compared to {approx}2-3 mm out-of-plane for tomosynthesis angles below {theta}{sub tot}{approx}45 deg. . An overall 3D localization accuracy of {approx}2.5 mm was achieved with {theta}{sub tot}{approx} 90 deg. for most tasks. The high in-plane spatial resolution, short scanning time, and low radiation dose characteristic of tomosynthesis may enable the surgeon to collect near real-time images throughout the procedure with minimal interference to surgical workflow. Therefore, tomosynthesis could provide a useful addition to the image-guided surgery arsenal, providing on-demand, high quality image updates, complemented by CBCT at critical milestones in the surgical procedure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Segmentation of pulmonary nodules in three-dimensional CT images by use of a spiral-scanning technique

Accurate segmentation of pulmonary nodules in computed tomography (CT) is an important and difficult task for computer-aided diagnosis of lung cancer. Therefore, the authors developed a novel automated method for accurate segmentation of nodules in three-dimensional (3D) CT. First, a volume of interest (VOI) was determined at the location of a nodule. To simplify nodule segmentation, the 3D VOI was transformed into a two-dimensional (2D) image by use of a key 'spiral-scanning' technique, in which a number of radial lines originating from the center of the VOI spirally scanned the VOI from the 'north pole' to the 'south pole'. The voxels scanned by the radial lines provided a transformed 2D image. Because the surface of a nodule in the 3D image became a curve in the transformed 2D image, the spiral-scanning technique considerably simplified the segmentation method and enabled reliable segmentation results to be obtained. A dynamic programming technique was employed to delineate the 'optimal' outline of a nodule in the 2D image, which corresponded to the surface of the nodule in the 3D image. The optimal outline was then transformed back into 3D image space to provide the surface of the nodule. An overlap between nodule regions provided by computer and by the radiologists was employed as a performance metric for evaluating the segmentation method. The database included two Lung Imaging Database Consortium (LIDC) data sets that contained 23 and 86 CT scans, respectively, with 23 and 73 nodules that were 3 mm or larger in diameter. For the two data sets, six and four radiologists manually delineated the outlines of the nodules as reference standards in a performance evaluation for nodule segmentation. The segmentation method was trained on the first and was tested on the second LIDC data sets. The mean overlap values were 66% and 64% for the nodules in the first and second LIDC data sets, respectively, which represented a higher performance level than those of two existing segmentation methods that were also evaluated by use of the LIDC data sets. The segmentation method provided relatively reliable results for pulmonary nodule segmentation and would be useful for lung cancer quantification, detection, and diagnosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Concurrent multimodality image segmentation by active contours for radiotherapy treatment planning

Multimodality imaging information is regularly used now in radiotherapy treatment planning for cancer patients. The authors are investigating methods to take advantage of all the imaging information available for joint target registration and segmentation, including multimodality images or multiple image sets from the same modality. In particular, the authors have developed variational methods based on multivalued level set deformable models for simultaneous 2D or 3D segmentation of multimodality images consisting of combinations of coregistered PET, CT, or MR data sets. The combined information is integrated to define the overall biophysical structure volume. The authors demonstrate the methods on three patient data sets, including a nonsmall cell lung cancer case with PET/CT, a cervix cancer case with PET/CT, and a prostate patient case with CT and MRI. CT, PET, and MR phantom data were also used for quantitative validation of the proposed multimodality segmentation approach. The corresponding Dice similarity coefficient (DSC) was 0.90{+-}0.02 (p<0.0001) with an estimated target volume error of 1.28{+-}1.23% volume. Preliminary results indicate that concurrent multimodality segmentation methods can provide a feasible and accurate framework for combining imaging data from different modalities and are potentially useful tools for the delineation of biophysical structure volumes in radiotherapy treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automatic multiscale enhancement and segmentation of pulmonary vessels in CT pulmonary angiography images for CAD applications

The authors are developing a computerized pulmonary vessel segmentation method for a computer-aided pulmonary embolism (PE) detection system on computed tomographic pulmonary angiography (CTPA) images. Because PE only occurs inside pulmonary arteries, an automatic and accurate segmentation of the pulmonary vessels in 3D CTPA images is an essential step for the PE CAD system. To segment the pulmonary vessels within the lung, the lung regions are first extracted using expectation-maximization (EM) analysis and morphological operations. The authors developed a 3D multiscale filtering technique to enhance the pulmonary vascular structures based on the analysis of eigenvalues of the Hessian matrix at multiple scales. A new response function of the filter was designed to enhance all vascular structures including the vessel bifurcations and suppress nonvessel structures such as the lymphoid tissues surrounding the vessels. An EM estimation is then used to segment the vascular structures by extracting the high response voxels at each scale. The vessel tree is finally reconstructed by integrating the segmented vessels at all scales based on a 'connected component' analysis. Two CTPA cases containing PEs were used to evaluate the performance of the system. One of these two cases also contained pleural effusion disease. Two experienced thoracic radiologists provided the gold standard of pulmonary vessels including both arteries and veins by manually tracking the arterial tree and marking the center of the vessels using a computer graphical user interface. The accuracy of vessel tree segmentation was evaluated by the percentage of the 'gold standard' vessel center points overlapping with the segmented vessels. The results show that 96.2% (2398/2494) and 96.3% (1910/1984) of the manually marked center points in the arteries overlapped with segmented vessels for the case without and with other lung diseases. For the manually marked center points in all vessels including arteries and veins, the segmentation accuracy are 97.0% (4546/4689) and 93.8% (4439/4732) for the cases without and with other lung diseases, respectively. Because of the lack of ground truth for the vessels, in addition to quantitative evaluation of the vessel segmentation performance, visual inspection was conducted to evaluate the segmentation. The results demonstrate that vessel segmentation using our method can extract the pulmonary vessels accurately and is not degraded by PE occlusion to the vessels in these test cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A patient-specific respiratory model of anatomical motion for radiation treatment planning

The modeling of respiratory motion is important for a more accurate understanding and accounting of its effect on dose to cancers in the thorax and abdomen by radiotherapy. We have developed a model of respiration-induced organ motion in the thorax without the commonly adopted assumption of repeatable breath cycles. The model describes the motion of a volume of interest within the patient based on a reference three-dimensional (3D) image (at end expiration) and the diaphragm positions at different time points. The input data are respiration-correlated CT (RCCT) images of patients treated for non-small- cell lung cancer, consisting of 3D images, including the diaphragm positions, at ten phases of the respiratory cycle. A deformable image registration algorithm calculates the deformation field that maps each 3D image to the reference 3D image. A principal component analysis is performed to parameterize the 3D deformation field in terms of the diaphragm motion. We show that the first two principal components are adequate to accurately and completely describe the organ motion in the data of four patients. Artifacts in the RCCT images that commonly occur at the mid-respiration states are reduced in the model-generated images. Further validation of the model is demonstrated in the successful application of the parameterized 3D deformation field to RCCT data of the same patient but acquired several days later. We have developed a method for predicting respiration-induced organ motion in patients that has potential for improving the accuracy of dose calculation in radiotherapy. Possible limitations of the model are cases where the correlation between lung tumor and diaphragm position is less reliable such as superiorly situated tumors and interfraction changes in tumor-diaphragm correlation. The limited number of clinical cases examined suggests, but does not confirm, the model's applicability to a wide range of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗