Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Approximation of Engine Casing Temperature Constraints for Casing Mounted Electronics

The performance of propulsion engine systems is sensitive to weight and volume considerations. This can severely constrain the configuration and complexity of the control system hardware. Distributed Engine Control technology is a response to these concerns by providing more flexibility in designing the control system, and by extension, more functionality leading to higher performing engine systems. Consequently, there can be a weight benefit to mounting modular electronic hardware on the engine core casing in a high temperature environment. This paper attempts to quantify the in-flight temperature constraints for engine casing mounted electronics. In addition, an attempt is made at studying heat soak back effects. The Commercial Modular Aero Propulsion System Simulation 40k (C-MAPSS40k) software is leveraged with real flight data as the inputs to the simulation. A two-dimensional (2-D) heat transfer model is integrated with the engine simulation to approximate the temperature along the length of the engine casing. This modification to the existing C-MAPSS40k software will provide tools and methodologies to develop a better understanding of the requirements for the embedded electronics hardware in future engine systems. Results of the simulations are presented and their implications on temperature constraints for engine casing mounted electronics is discussed.

Engine↗

GEM-CEDAR Challenge: Poynting Flux at DMSP and Modeled Joule Heat

Poynting flux into the ionosphere measures the electromagnetic energy coming from the magnetosphere. This energy flux can vary greatly between quiet times and geomagnetic active times. As part of the Geospace Environment Modeling-coupling energetics and dynamics of atmospheric regions modeling challenge, physics-based models of the 3-D ionosphere and ionospheric electrodynamics solvers of magnetosphere models that specify Joule heat and empirical models specifying Poynting flux were run for six geomagnetic storm events of varying intensity. We compared model results with Poynting flux values along the DMSP-15 satellite track computed from ion drift meter and magnetic field observations. Although being a different quantity, Joule heat can in practice be correlated to incoming Poynting flux because the energy is dissipated primarily in high latitudes where Poynting flux is being deposited. Within the physics-based model group, we find mixed results with some models overestimating Joule heat and some models agreeing better with observed Poynting flux rates as integrated over auroral passes. In contrast, empirical models tend to underestimate integrated Poynting flux values. Modeled Joule heat or Poynting flux patterns often resemble the observed Poynting flux patterns on a large scale, but amplitudes can differ by a factor of 2 or larger due to the highly localized nature of observed Poynting flux deposition that is not captured by the models. In addition, the positioning of modeled patterns appear to be randomly shifted against the observed Poynting flux energy input. This study is the first to compare Poynting flux and Joule heat in a large variety of models of the ionosphere.

Rastaetter, Lutz↗

Approximation of Engine Casing Temperature Constraints for Casing Mounted Electronics

The performance of propulsion engine systems is sensitive to weight and volume considerations. This can severely constrain the configuration and complexity of the control system hardware. Distributed Engine Control technology is a response to these concerns by providing more flexibility in designing the control system, and by extension, more functionality leading to higher performing engine systems. Consequently, there can be a weight benefit to mounting modular electronic hardware on the engine core casing in a high temperature environment. This paper attempts to quantify the in-flight temperature constraints for engine casing mounted electronics. In addition, an attempt is made at studying heat soak back effects. The Commercial Modular Aero Propulsion System Simulation 40k (C-MAPSS40k) software is leveraged with real flight data as the inputs to the simulation. A two-dimensional (2-D) heat transfer model is integrated with the engine simulation to approximate the temperature along the length of the engine casing. This modification to the existing C-MAPSS40k software will provide tools and methodologies to develop a better understanding of the requirements for the embedded electronics hardware in future engine systems. Results of the simulations are presented and their implications on temperature constraints for engine casing mounted electronics is discussed.

Engine↗

Development of an Additive Manufactured Cryogenic TVS Augmented Injector

Cryogenic fluid transfer is critical in ground and space systems. Transfer typically requires venting a receiver vessel during the chill and fill process to maintain a pressure favorable to fluid flow. Venting in space is problematic due to low-gravity where fluid position is indeterminate; possibly allowing fluid to flow out the vent. To control receiver tank venting the vented chill/no-vent fill methodology is attractive. An additively manufactured Injector coupled with a Thermodynamic Venting System (TVS) augmentation can enable the vented chill/no-vent fill approach with simplified operations. The TVS augmented injector includes an internal heat exchanger, fluid injector spray head, and external surface condensation heat exchange; combined with integrated flow paths in one part. Operations using the injector allow the tank vent to be closed very early in the transfer and not reopened. The TVS circuit eliminates the potential for stalled fill by maintaining cooling flow on the injector and condenser elements, reducing tank pressure. The injector can also be employed for long-term cryo fluid storage as a means of controlling tank pressure if integrated with a recirculation pump. A cryo-cooler can be used in place of/or augmenting the TVS flow circuit for a zero loss pressure control system. The Injector was developed using the principles of design for additive manufacture and printed as one part, resulting in part count reduction, improved reproducibility, shorter lead times, and reduced cost. The TVS augmented injector is compact and highly adaptable simplifying its integration. A key benefit is that this methodology enables simplified operations in reaching 100% fill conditions.

Omar Mireles↗

Best Practices Case Study: CDC Realty, Inc. - Centennial Terrace, Tucson, AZ

Case study on CDC Realty who achieved HERS 70 by putting ducts in a conditioned attic insulated along the roofline with netted cellulose, R-5 rigid insulated sheathing over R-19 wall cavity insulation, and deep overhangs and low-e windows to minimize solar heat gain. The 17 homes are solar-ready for solar water heating and five have integral collector storage hot water systems on the roof.

Building America↗

High Temperature Heat Pumps and Their Roles in the Decarbonization of Building and Industry

Heat pumps have been sought as a promising technology for air and water heating processes in buildings. Several OEMs have been commercializing heat pumps with varying capacities; However, the application has been limited to lower temperatures (less than 70℃). With the recently growing interest in replacing gas-fired equipment for buildings and industrial processes, a new class of heat pumps, known as high-temperature heat pumps, is gaining substantial interest where the target temperatures are higher than the conventional heat pump technology (greater than 90℃). The current study is focused on this class of heat pumps and aims to provide a holistic overview of state-of-the-art technology while highlighting major challenges and opportunities. The discussion will be focused on the availability of technology to enable higher sink temperatures, deployment-based applications, waste heat recovery, and process integration and controls.

Nawaz, Kashif↗

Electric Motor Thermal Management

The poster reports the accomplishments of EDT-Electric Motor Thermal Management consortium project for 2024 VTO Annual Merit Review (AMR). The overall aims of the project are to support research enabling compact, reliable, low-cost, and efficient electric machines aligned with roadmap research areas; to collaborate with ORNL, Ames, and SNL to provide motor thermal analysis support, reliability evaluation, and material measurements on related motor research at national laboratories; and collaborate with university partners including Georgia Institute of Technology and University of Wisconsin Madison to support university-led motor thermal management research efforts.

ADVANCED PROPULSION SYSTEMS↗

Fast-Ignition Target Design and Experimental-Concept Validation on OMEGA

A comprehensive scientific program is being pursued at LLE to explore the physics of fast ignition. The OMEGA EP Laser was completed in April 2008, adjacent to the 60 beam, 30 kJ OMEGA Laser Facility. OMEGA EP consists of four beamlines with a NIF-like architecture, each delivering up to 6.5 kJ of UV laser energy in long pulse (ns) mode into the OMEGA EP target chamber. Two of the beamlines can operate as high-energy petawatt lasers, with up to 2.6 kJ each with 10 ps pulse duration. These beams can either be injected into the OMEGA EP target chamber or combined collinearly into the existing OMEGA target chamber for integrated fast-ignitor experiments. Fuel-assembly experiments on OMEGA have achieved high fuel areal densities, and the effects of a cone on the fuel assembly are being studied. Experiments on short-pulse laser systems in collaboration with other institutions are being pursued to investigate the conversion efficiency from laser energy to fast electrons. A coherent transition radiation diagnostic to study the transport of the electrons in high-density material is being developed. Integrated experiments with room-temperature targets on OMEGA will be performed in 2008. Simulations of these integrated experiments show significant heating of up to 1 keV due to the hot electrons from the short-pulse laser.

Stoeckl, C↗

A top loading 2 Kelvin test cryostat for SRF cavities.

A new large 2 Kelvin test cryostat is being commissioned at Argonne National Laboratory. This system will have a full time connection to the 4.5 Kelvin ATLAS refrigerator and, with integrated J-T heat exchanger, will allow continuous 2 Kelvin operation. The large diameter was chosen to accommodate essentially all of today's superconducting cavities and the top loading design facilitates clean room assembly. The commissioning run will be with a coaxial half wave cavity to be followed by testing with 1.3 GHz single-cell elliptical cavities. Details of the initial engineering cool down on the cryostat are presented.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

James Webb Space Telescope Integrated Science Instrument Module Calibration and Verification of High-Accuracy Instrumentation to Measure Heat Flow in Cryogenic Testing

The James Webb Space Telescope (JWST) is an upcoming flagship observatory mission scheduled to be launched in 2018, Three of the four science instruments are passively cooled to their operational temperature range of 36K to 40K, and the fourth instrument is actively cooled to its operational temperature of approximately 6K. The requirement for multiple thermal zones results in the instruments being thermally connected to five external radiators via individual high purity aluminum heat straps. Thermal-vacuum and thermal balance testing of the flight instruments at the Integrated Science Instrument Module (ISIM) element level will take place within a newly constructed shroud cooled by gaseous helium inside Goddard Space Flight Center's (GSFC) Space Environment Simulator (SES). The flight external radiators are not available during ISIM-Ievel thermal vacuum/thermal testing, so they will be replaced in test with stable and adjustable thermal boundaries with identical physical interfaces to the flight radiators. Those boundaries are provided on specially designed test hardware which measures the heat flow within each of the five heat straps to an accuracy of less than 2 m W, which is less than 5% of the minimum predicted heat flow values. This is essential to ISIM thermal model correlation, since thermal models are more accurately correlated when temperature data is supplemented by accurate knowledge of heat flows. Devices that measure heat flow in this manner have historically been referred to as "Q-meters". Perhaps the most important feature of the design of the Q-meters is that it does not depend on the absolute accuracy of its temperature sensors, but rather on a difference in heater power, for which a table is empirically developed during a calibration campaign in a small chamber at GSFC. This paper discusses the Q-meter calibration procedure including calibration chamber modifications and accommodations, the handling of differing conditions between calibration and usage, the calibration process itself, and the results of the tests used to determine if the calibration is successful.

Comber, Brian↗

James Webb Space Telescope Integrated Science Instrument Module Calibration and Verification of High-Accuracy Instrumentation to Measure Heat Flow in Cryogenic Testing

The James Webb Space Telescope (JWST) is an upcoming flagship observatory mission scheduled to be launched in 2018. Three of the four science instruments are passively cooled to their operational temperature range of 36K to 40K, and the fourth instrument is actively cooled to its operational temperature of approximately 6K. The requirement for multiple thermal zoned results in the instruments being thermally connected to five external radiators via individual high purity aluminum heat straps. Thermal-vacuum and thermal balance testing of the flight instruments at the Integrated Science Instrument Module (ISIM) element level will take place within a newly constructed shroud cooled by gaseous helium inside Goddard Space Flight Center's (GSFC) Space environment Simulator (SES). The flight external radiators are not available during ISIM-level thermal vacuum/thermal testing, so they will be replaced in test with stable and adjustable thermal boundaries with identical physical interfaces to the flight radiators. Those boundaries are provided by specially designed test hardware which also measures the heat flow within each of the five heat straps to an accuracy of less than 2 mW, which is less than 5% of the minimum predicted heat flow values. Measurement of the heat loads to this accuracy is essential to ISIM thermal model correlation, since thermal models are more accurately correlated when temperature data is supplemented by accurate knowledge of heat flows. It also provides direct verification by test of several high-level thermal requirements. Devices that measure heat flow in this manner have historically been referred to a "Q-meters". Perhaps the most important feature of the design of the JWST Q-meters is that it does not depend on the absolute accuracy of its temperature sensors, but rather on knowledge of precise heater power required to maintain a constant temperature difference between sensors on two stages, for which a table is empirically developed during a calibration campaign in a small chamber at GSFC. This paper provides a brief review of Q-meter design, and discusses the Q-meter calibration procedure including calibration chamber modifications and accommodations, handling of differing conditions between calibration and usage, the calibration process itself, and the results of the tests used to determine if the calibration is successful.

Comber, Brian↗

System Design Techniques for Reducing the Power Requirements of Advanced life Support Systems

The high power requirement associated with overall operation of regenerative life support systems is a critical Z:p technological challenge. Optimization of individual processors alone will not be sufficient to produce an optimized system. System studies must be used in order to improve the overall efficiency of life support systems. Current research efforts at NASA Ames Research Center are aimed at developing approaches for reducing system power and energy usage in advanced life support systems. System energy integration and energy reuse techniques are being applied to advanced life support, in addition to advanced control methods for efficient distribution of power and thermal resources. An overview of current results of this work will be presented. The development of integrated system designs that reuse waste heat from sources such as crop lighting and solid waste processing systems will reduce overall power and cooling requirements. Using an energy integration technique known as Pinch analysis, system heat exchange designs are being developed that match hot and cold streams according to specific design principles. For various designs, the potential savings for power, heating and cooling are being identified and quantified. The use of state-of-the-art control methods for distribution of resources, such as system cooling water or electrical power, will also reduce overall power and cooling requirements. Control algorithms are being developed which dynamically adjust the use of system resources by the various subsystems and components in order to achieve an overall goal, such as smoothing of power usage and/or heat rejection profiles, while maintaining adequate reserves of food, water, oxygen, and other consumables, and preventing excessive build-up of waste materials. Reductions in the peak loading of the power and thermal systems will lead to lower overall requirements. Computer simulation models are being used to test various control system designs.

Finn, Cory↗

Utility of Bromide and Heat Tracers for Aquifer Characterization Affected by Highly Transient Flow Conditions

A tracer test using both bromide and heat tracers conducted at the Integrated Field Research Challenge site in Hanford 300 Area (300A), Washington, provided an instrument for evaluating the utility of bromide and heat tracers for aquifer characterization. The bromide tracer data were critical to improving the calibration of the flow model complicated by the highly dynamic nature of the flow field. However, most bromide concentrations were obtained from fully screened observation wells, lacking depth-specific resolution for vertical characterization. On the other hand, depth-specific temperature data were relatively simple and inexpensive to acquire. However, temperature-driven fluid density effects influenced heat plume movement. Moreover, the temperature data contained “noise” caused by heating during fluid injection and sampling events. Using the hydraulic conductivity distribution obtained from the calibration of the bromide transport model, the temperature depth profiles and arrival times of temperature peaks simulated by the heat transport model were in reasonable agreement with observations. This suggested that heat can be used as a cost-effective proxy for solute tracers for calibration of the hydraulic conductivity distribution, especially in the vertical direction. However, a heat tracer test must be carefully designed and executed to minimize fluid density effects and sources of noise in temperature data. A sensitivity analysis also revealed that heat transport was most sensitive to hydraulic conductivity and porosity, less sensitive to thermal distribution factor, and least sensitive to thermal dispersion and heat conduction. This indicated that the hydraulic conductivity remains the primary calibration parameter for heat transport.

Ma, Rui↗

Retrofitting Combined Space and Water Heating Systems: Laboratory Tests

Better insulated and tighter homes can often use a single heating plant for both space and domestic water heating. These systems, called dual integrated appliances (DIA) or combination systems, can operate at high efficiency and eliminate combustion safety issues associated by using a condensing, sealed combustion heating plant. Funds were received to install 400 DIAs in Minnesota low-incomehomes. The NorthernSTAR DIA laboratory was created to identify proper system components, designs, operating parameters, and installation procedures to assure high efficiency of field installed systems. Tests verified that heating loads up to 57,000 Btu/hr can be achieved with acceptable return water temperatures and supply air temperatures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Retrofitting Combined Space and Water Heating Systems: Laboratory Tests

Better insulated and tighter homes can often use a single heating plant for both space and domestic water heating. These systems, called dual integrated appliances (DIA) or combination systems, can operate at high efficiency and eliminate combustion safety issues associated by using a condensing, sealed combustion heating plant. Funds were received to install 400 DIAs in Minnesota low-income homes. The NorthernSTAR DIA laboratory was created to identify proper system components, designs, operating parameters, and installation procedures to assure high efficiency of field installed systems. Tests verified that heating loads up to 57,000 Btu/hr can be achieved with acceptable return water temperatures and supply air temperatures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗