Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HELICITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Space-resolved extreme ultraviolet spectrometer for impurity emission profile measurement in Large Helical Device

A space-resolved extreme ultraviolet (EUV) spectrometer working in 60-400 A range has been developed to observe impurity emission profiles in core and edge plasmas of Large Helical Device (LHD). A flat focus is made for plane surface detector by using a varied line spacing holographic grating with an angle of incidence of 87 deg. An excellent spectral resolution of 0.22 A at 200 A is then obtained after careful adjustment of the optical components. In the profile measurement of the LHD plasmas, the toroidal resolution is important as well as the radial resolution because the magnetic surfaces of LHD quickly change when the observation chord is tilted at a slightly different toroidal location. Horizontal dispersion is therefore selected for the present spectrometer. As a result, the toroidal resolution of 75 mm is achieved at the plasma position. An enough radial resolution of 10 mm is also obtained at spatial-resolution slit width of 0.2 mm. In order to measure the full radial profile of LHD plasmas the spectrometer is placed at a distance of {approx}9200 mm away from the plasma center and a backilluminated charge-coupled device with a size of 6.6x26.6 mm{sup 2} is set vertical to the horizontal dispersion. Half of the LHD plasma, i.e., {approx}50 cm, can be measured along the vertical direction at horizontally elongated plasma cross section. A full vertical profile can be obtained by changing the vertical angle of the EUV spectrometer. As an example the full vertical profile of edge C IV (312.4 A) emission is presented. A wavelength interval of 35-65 A can be simultaneously observed, which varies according to the wavelength to be measured. A local emission profile of Fe XX (132.67 A) is also presented after Abel inversion as a typical example of the core EUV emission. Finally, the EUV spectrometer is absolutely calibrated using EUV bremsstrahlung continuum profile in comparison with absolute values of visible bremsstrahlung continuum profile because the bremsstrahlung continuum can be easily detected in high-density discharges of LHD.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Internal electron transport barrier due to neoclassical ambipolarity in the Helically Symmetric Experiment

Electron cyclotron heated plasmas in the Helically Symmetric Experiment (HSX) feature strongly peaked electron temperature profiles; central temperatures are 2.5 keV with 100 kW injected power. These measurements, coupled with neoclassical predictions of large 'electron root' radial electric fields with strong radial shear, are evidence of a neoclassically driven thermal transport barrier. Neoclassical transport quantities are calculated using the PENTA code [D. A. Spong, Phys. Plasmas 12, 056114 (2005)], in which momentum is conserved and parallel flow is included. Unlike a conventional stellarator, which exhibits strong flow damping in all directions on a flux surface, quasisymmetric stellarators are free to rotate in the direction of symmetry, and the effect of momentum conservation in neoclassical calculations may therefore be significant. Momentum conservation is shown to modify the neoclassical ion flux and ambipolar ion root radial electric fields in the quasisymmetric configuration. The effect is much smaller in a HSX configuration where the symmetry is spoiled. In addition to neoclassical transport, a model of trapped electron mode turbulence is used to calculate the turbulent-driven electron thermal diffusivity. Turbulent transport quenching due to the neoclassically predicted radial electric field profile is needed in predictive transport simulations to reproduce the peaking of the measured electron temperature profile [Guttenfelder et al., Phys. Rev. Lett. 101, 215002 (2008)].

43 PARTICLE ACCELERATORS↗

Z{sub eff} profile diagnostics using visible bremsstrahlung continuum for nonaxisymmetric plasmas with finite {beta} in large helical device

An astigmatism-corrected Czerny-Turner-type visible spectrometer coupled with a charge-coupled device has been installed in large helical device (LHD) to measure visible bremsstrahlung continuum. A full vertical profile has been observed from the elliptical plasmas at horizontally elongated plasma cross section through a 44 fiber parallel array with vertical observation length of {approx}1 m. Line emissions can be easily eliminated by use of the visible spectrometer instead of an interference filter. A nonmonotonic bremsstrahlung emission profile, which is originated in the thick ergodic layer surrounding the main plasma, has been observed for normal discharges in all the magnetic configurations of LHD. After analyzing the detailed structure, the lower half of the vertical bremsstrahlung emission profile is found to be free of the strong edge bremsstrahlung emission in inwardly shifted magnetic configurations (R{sub ax{<=}}3.60 m). The nonmonotonic bremsstrahlung emission disappeared in extremely high-density discharges (n{sub e{>=}}10{sup 14} cm{sup -3}) because of the reduction of the plasma outside boundary. When the local emissivity is calculated using Abel inversion, the solution is very sensitive to the distortion of the magnetic surface structure. The influence of the magnetic surface distortion based on the finite {beta} effect is examined as error estimation in addition to unclear edge plasma boundary due to the presence of the ergodic layer. The result indicates that the determination of the normalized minor radius for each observation chord gives a larger influence on the Abel inversion rather than the determination of the chord length. When the observed chord-integrated bremsstrahlung intensity profile is flat, the resultant uncertainty seen in the bremsstrahlung emissivity profile becomes large, in particular, at the plasma center. The Z{sub eff} profile calculated with consideration of density and temperature profiles is verified in neutral-beam-heated discharges with H{sub 2} and C pellet injections, where the Z{sub eff} values should be close to 1 and 6, respectively. Analysis on the flat and hollow electron density profiles results in a fairly flat Z{sub eff} profile.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of multiwavelength-range fine-resolution spectrometer for hydrogen emissions and its application to large helical device periphery plasmas

We developed a spectrometer specialized for simultaneous observation of the hydrogen Balmer-{alpha}, -{beta}, -{gamma} lines and the Fulcher-{alpha} v'=v''=2 rovibronic transition band. The spectrometer was optimized for the light input coupled by nine optical fibers having 400 {mu}m core diameters. The spectral resolutions were 0.02-0.03 nm for these wavelength ranges at the entrance slit width of 20 {mu}m. The polarization resolved spectra of these emissions from the peripheral region of large helical device (LHD) plasmas were measured simultaneously and showed the polarization dependence coming from the magnetic field in the LHD plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detachment stabilization with n/m=1/1 resonant magnetic perturbation field applied to the stochastic magnetic boundary of the Large Helical Device

It is found that the remnant island structure created by n/m=1/1 resonant magnetic perturbation field in the stochastic magnetic boundary of the Large Helical Device (LHD) [A. Komori et al., Nucl. Fusion 49, 104015 (2009)] has a stabilizing effect on formation of radiating plasma, realizing stably sustained divertor detachment operation with the core plasma being unaffected. The data from the several diagnostics, (profiles of electron temperature and density, radiation and temporal evolution of divertor particle flux) indicate selective cooling around X-point of the island and thus peaked radiation there, which is stabilized outside of the last closed flux surface throughout the detachment phase. The vacuum ultraviolet spectroscopy measurements of high Z impurity (iron) emission shows significant decrease during the detachment, indicating core plasma decontamination. The results from the three-dimensional (3D) edge transport code, edge Monte Carlo 3D (EMC3) [Y. Feng et al., Contrib. Plasma Phys. 44, 57 (2004)]-EIRENE [D. Reiter et al., Fusion Sci. Technol. 47, 172 (2005)] show similar tendency in the radiation pattern. The island size and its radial location are varied to investigate the magnetic topology effects on the detachment control. The divertor particle flux and neutral pressure exhibit intermittent oscillation as well as modification of recycling pattern during the detachment, which are found to reflect the island structure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Helical FOFO Snake for 6D Ionization Cooling of Muons

A channel for 6D ionization cooling of muons is described which consists of periodically inclined solenoids of alternating polarity, liquid hydrogen absorbers placed inside the solenoids and RF cavities between them. An important feature of such a channel (called Helical FOFO snake) is that it can cool simultaneously muons of both signs. Theoretical considerations as well as results of simulations with G4beamline are presented which show that a 200 MHz HFOFO snake has sufficient acceptance to be used for initial 6D cooling in muon colliders and neutrino factories.

43 PARTICLE ACCELERATORS↗

Site-Selective Determination of Magnetic Helices in BaTiCoFe{sub 10}O{sub 19} by Resonant Magnetic Scattering

Synchrotron radiation intensity measurements were made for single crystals of ferrimagnetic BaTiCoFe{sub 10}O{sub 19} at the BL-6C(3A) beamline of the Photon Factory. The resonant x-ray magnetic scattering (RXMS) method at the Fe K edge makes it possible to determine the magnetic crystal structure, having the magnetic helices for Fe ions in tetrahedral 4f{sub 1}, bipyramidal 2b, and octahedral 2a, 4f{sub 2} and 12k sites. Based on the information on x-ray magnetic circular dichroism (XMCD) and a resonant magnetic scattering factor f''{sub m} ( = 0.23) estimated from BaFe{sub 12}O{sub 19} at E = 7128.2 eV, the magnetic structures have been determined from an asymmetrical ratio {Delta}R (Y{sup +}-Y{sup -})/(Y{sup +}+Y{sup -}), where Y{sup +} and Y{sup -} are scattering intensities for left- and right-circular polarizations, respectively. Spin orientations were estimated in the least-squares procedure to minimize a residual factor of {Sigma}({Delta}R{sub obs}-{Delta}R{sub calc}){sup 2}. The canting angles estimated in this study are 180 deg., 19 deg., 118 deg., 180 deg. and 65 deg. for the magnetic moments of Fe ions in 4f{sub 1}, 2b, 2a, 4f{sub 2} and 12k sites, respectively.

36 MATERIALS SCIENCE↗

Far-forward collective scattering measurements of density fluctuations in the helically symmetric experiment stellarator

The multichannel interferometer system on the helically symmetric experiment (HSX) stellarator is reconfigured to perform far-forward collective scattering measurements of electron density fluctuations. The collective scattering system has nine viewing chords with 1.5 cm spacing. Scattered power is measured using a homodyne detection scheme. Far-forward collective scattering provides a line-integrated measurement of fluctuations within the divergence of the probe beam covering wavenumber range: k{sub perpendicular}<2 cm{sup -1}. The perpendicular wavenumber consists of poloidal and radial contributions that vary with chord position. Both coherent modes and broadband fluctuation are measured. When HSX is operated without quasihelical symmetry at B{sub T}=1 T and n{sub e}{approx}4x10{sup 12} cm{sup -3}, a coherent electrostatic fluctuation is observed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Poloidal beam emission spectroscopy system for the measurement of density fluctuations in Large Helical Device

A system of beam emission spectroscopy (BES) for density fluctuation measurements having the sightlines passing through the plasma in the poloidal direction was developed in the Large Helical Device (LHD). Even though the angle between the beam and the sightline is slightly larger than a right angle, Doppler-shifted beam emission can be distinguished from background emission because of the high energy (120-170 keV) of the neutral beam for heating with negative ion sources. Spatial resolution is about 0.1-0.2 in the normalized radius. Compared with the prototype BES system with toroidal sightlines, the BES system with poloidal sightlines showed improved spatial resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multifrequency channel microwave reflectometer with frequency hopping operation for density fluctuation measurements in Large Helical Device

In order to measure the internal structure of density fluctuations using a microwave reflectometer, the broadband frequency tunable system, which has the ability of fast and stable hopping operation, has been improved in the Large Helical Device. Simultaneous multipoint measurement is the key issue of this development. For accurate phase measurement, the system utilizes a single sideband modulation technique. Currently, a dual channel heterodyne frequency hopping reflectometer system has been constructed and applied to the Alfven eigenmode measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Objectives and layout of a high-resolution x-ray imaging crystal spectrometer for the large helical device

A high-resolution x-ray imaging crystal spectrometer, whose concept was tested on NSTX and Alcator C-Mod, is being designed for the large helical device (LHD). This instrument will record spatially resolved spectra of helium-like Ar{sup 16+} and will provide ion temperature profiles with spatial and temporal resolutions of <2 cm and {>=}10 ms, respectively. The spectrometer layout and instrumental features are largely determined by the magnetic field structure of LHD. The stellarator equilibrium reconstruction codes, STELLOPT and PIES, will be used for the tomographic inversion of the spectral data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simultaneous projection and detection system of four different frequencies for microwave imaging reflectometry in Large Helical Device

A simultaneous projection/detection system of four different frequencies for microwave imaging reflectometry (MIR) was developed for three-dimensional observation of electron density fluctuations in the Large Helical Device (LHD). The microwave with four frequency components at 60.410, 61.808, 63.008, and 64.610 GHz is projected in a continuous-wave mode to illuminate the target LHD plasma. A two-dimensional horn-antenna mixer array (2D HMA) receives the reflected wave from the plasma as well as the wave from the local oscillator operating at 55.800 GHz. The first intermediate frequency (IF) signals at 4.610, 6.008, 7.208, and 8.810 GHz were confirmed to be obtained by downconversion of these microwaves using the 2D HMA. Each of these first IF components is filtered from each other and downconverted again for the superheterodyne detection. It was confirmed that both the amplitudes and the phases of the detected signals reflect the fluctuations in LHD plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of electron cyclotron emission imaging system on Large Helical Device

A combined system of microwave imaging reflectometry and electron cyclotron emission (ECE) imaging has been developed for the Large Helical Device. This system includes a wide-band two-dimensional horn-antenna mixer array (HMA). The HMA consists of horn antennas, waveguides, mixers, and intermediate frequency circuits. The frequency response of the HMA is between 50 and 110 GHz. The ECE signal is selected using a 95 GHz local oscillator and a 93 GHz high-pass filter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fusion product diagnostics planned for Large Helical Device deuterium experiment

Deuterium experiment on the Large Helical Device (LHD) is now being planned at the National Institute for Fusion Science. The fusion product diagnostics systems currently considered for installation on LHD are described in this paper. The systems will include a time-resolved neutron yield monitor based on neutron gas counters, a time-integrated neutron yield monitor based on activation techniques, a multicollimator scintillation detector array for diagnosing spatial distribution of neutron emission rate, 2.5 MeV neutron spectrometer, 14 MeV neutron counter, and prompt {gamma}-ray diagnostics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhancement of cross-field transport into the private region of detached-divertor in Large Helical Device

The fluctuation of ion saturation currents in the attached- and detached-divertor plasmas of the Large Helical Device [Fujiwara et al., Nucl. Fusion 41, 1355 (2001)] has been measured using a Langmuir probe array embedded in a divertor plate. Analytical results indicate that these fluctuation properties differ considerably from each other; for instance, the mean value distribution expands to and positive spikes propagate toward a private region from the divertor leg in the detached-divertor. We investigated the magnetic field lines traced from probe electrodes by using the KMAG code [Nakamura et al., J. Plasma Fusion Res. 69, 41 (1993)], and it is then confirmed that the propagation direction of positive spikes corresponds to that predicted by the theory of blobby plasma transport. This phenomenon is expected to lead to the broadening of plasma particle and heat fluxes to the divertor plate.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Note: A helical velocity selector for continuous molecular beams

We report on a modern realization of the classic helical velocity selector for gas phase particle beams. The device operates stably under high vacuum conditions at rotational frequencies limited only by commercial dc motor capabilities. Tuning the rotational frequency allows selective scanning over a broad velocity band. The width of the selected velocity distributions at full-width-half-maximum is as narrow as a few percent of the selected mean velocity and independent of the rotational speed of the selector. The selector generates low vibrational noise amplitudes comparable to mechanically damped state-of-the-art turbo-molecular pumps and is therefore compatible with vibration sensitive experiments like molecule interferometry.

43 PARTICLE ACCELERATORS↗

High-Gradient High-Energy-Gain Inverse Free Electron Laser Experiment Using a Helical Undulator

In this paper we present the design of the high-gradient, high-energy-gain IFEL accelerator proposed for construction at the ATF beamline in BNL. We plan to accelerate the ATF electron beam from 50 MeV to 120 MeV using a 60 cm long tapered permanent magnet helical undulator designed at UCLA and the existing ATF 0.5 TW CO2 laser system. The experiment will obtain a record 120 MV/m gradient and >70 MeV energy gain and will be an important step in the development of compact IFEL accelerators for the mid-high energy range (up to 1-2 GeV).

43 PARTICLE ACCELERATORS↗

Design and performance of a punch mechanism based pellet injector for alternative injection in the large helical device

A low speed single barrel pellet injector, using a mechanical punch device has been developed for alternative injection in the large helical device. A pellet is injected by the combined operation of a mechanical punch and a pneumatic propellant system. The pellet shape is cylindrical, 3 mm in diameter and 3 mm in length. Using this technique the speed of the pellet can be controlled flexibly in the range of 100-450 m/s, and a higher speed can be feasible for a higher gas pressure. The injector is equipped with a guide tube selector to direct the pellet to different injection locations. Pellets are exposed to several curved parts with the curvature radii R{sub c}= 0.8 and 0.3 m when they are transferred in guided tubes to the respective injection locations. Pellet speed variation with pressure at different pellet formation temperatures has been observed. Pellet intactness tests through these guide tubes show a variation in the intact speed limit over a range of pellet formation temperatures from 6.5 to 9.8 K. Pellet speed reduction of less than 6% has been observed after the pellet moves through the curved guide tubes.

42 ENGINEERING↗