Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ground testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Studies of Nucleon Form Factors with 12 GeV CEBAF and SuperBigBite

The elastic electromagnetic form factors are among the most fundamental quantities that describe the ground-state structure of the proton and neutron. Precision data of the form factors over a wide kinematical range provide a powerful test of current theories of hadron structure. A number of experiments aiming to measure the electric and magnetic elastic form factors of the neutron, G{sub E}{sup n} and G{sub M}{sup n}, and proton, G{sub E}{sup p}, at very high momentum transfer, up to the range of Q{sup 2} = 10-14 (GeV/c){sup 2}, are planned to be carried out with the future 11 GeV electron beam of the upgraded CEBAF at Jefferson Lab. These experiments will determine the nucleon form factors with unprecedented precision to Q{sup 2}-values up to three times higher than those of existing data. We review the approved proposals and the conceptual design of a new spectrometer, SuperBigBite, that will be used in these and other future experiments at Jefferson Lab.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High resolution transmission spectroscopy as a diagnostic for Jovian exoplanet atmospheres: constraints from theoretical models

We present high resolution transmission spectra of giant planet atmospheres from a coupled three-dimensional (3D) atmospheric dynamics and transmission spectrum model that includes Doppler shifts which arise from winds and planetary motion. We model Jovian planets covering more than two orders of magnitude in incident flux, corresponding to planets with 0.9-55 day orbital periods around solar-type stars. The results of our 3D dynamical models reveal certain aspects of high resolution transmission spectra that are not present in simple one-dimensional (1D) models. We find that the hottest planets experience strong substellar to anti-stellar (SSAS) winds, resulting in transmission spectra with net blueshifts of up to 3 km s{sup –1}, whereas less irradiated planets show almost no net Doppler shifts. We find only minor differences between transmission spectra for atmospheres with temperature inversions and those without. Compared to 1D models, peak line strengths are significantly reduced for the hottest atmospheres owing to Doppler broadening from a combination of rotation (which is faster for close-in planets under the assumption of tidal locking) and atmospheric winds. Finally, high resolution transmission spectra may be useful in studying the atmospheres of exoplanets with optically thick clouds since line cores for very strong transitions should remain optically thick to very high altitude. High resolution transmission spectra are an excellent observational test for the validity of 3D atmospheric dynamics models, because they provide a direct probe of wind structures and heat circulation. Ground-based exoplanet spectroscopy is currently on the verge of being able to verify some of our modeling predictions, most notably the dependence of SSAS winds on insolation. We caution that interpretation of high resolution transmission spectra based on 1D atmospheric models may be inadequate, as 3D atmospheric motions can produce a noticeable effect on the absorption signatures.

79 ASTRONOMY AND ASTROPHYSICS↗

Soil net nitrogen mineralization and leaching under Miscanthus × giganteus and Zea mays

Abstract The winter fallow period common in annual cropping systems leaves soils vulnerable to erosion and nutrient loss, especially to nitrogen (N) leaching. This vulnerability can be mitigated with perennial crops that have living roots in the ground year‐round. The mechanisms, magnitude, and consistency with which perennial crops retain N are not clear. We used an experiment to test whether a perennial crop, miscanthus ( Miscanthus × giganteus Greef et Deu.), would leach less N than continuous maize ( Zea mays L.) and how soil net N mineralization (N min ) may explain observed leaching under varied environment and management conditions. The experiment included three crossed factors: (1) cropping system (maize, juvenile miscanthus = 1–2 years old, mature miscanthus = 3–4 years old); (2) N fertilization (0 and 224 kg N ha −1 ); and (3) environment (four site‐years at two locations in Iowa, USA, that differed in climate and soil fertility). We measured N cycling dynamics, including: inorganic soil N (ammonium + nitrate), in situ N min , N leaching, crop N uptake, and calculated system N use efficiency. There were many complex interactions among factors. On average, cumulative N min under juvenile miscanthus was 111% greater than maize, but as miscanthus matured, there was no difference in N min between the perennial crop and maize. There was no difference in N leaching between juvenile miscanthus and maize, but mature miscanthus decreased N leaching by 42% and 88% compared to maize (with and without N fertilization, respectively). Across all treatments, there was no relationship between N min and N leaching, suggesting other mechanisms are regulating N leaching. Overall, mature miscanthus shows promise as a tool to reduce N losses in areas dominated by annual row‐crops.

54 ENVIRONMENTAL SCIENCES↗

Geochemical detection of carbon dioxide in dilute aquifers

Carbon storage in deep saline reservoirs has the potential to lower the amount of CO{sub 2} emitted to the atmosphere and to mitigate global warming. Leakage back to the atmosphere through abandoned wells and along faults would reduce the efficiency of carbon storage, possibly leading to health and ecological hazards at the ground surface, and possibly impacting water quality of near-surface dilute aquifers. We use static equilibrium and reactive transport simulations to test the hypothesis that perturbations in water chemistry associated with a CO{sub 2} gas leak into dilute groundwater are important measures for the potential release of CO{sub 2} to the atmosphere. Simulation parameters are constrained by groundwater chemistry, flow, and lithology from the High Plains aquifer. The High Plains aquifer is used to represent a typical sedimentary aquifer overlying a deep CO{sub 2} storage reservoir. Specifically, we address the relationships between CO{sub 2} flux, groundwater flow, detection time and distance. The CO{sub 2} flux ranges from 10{sup 3} to 2 x 10{sup 6} t/yr (0.63 to 1250 t/m{sup 2}/yr) to assess chemical perturbations resulting from relatively small leaks that may compromise long-term storage, water quality, and surface ecology, and larger leaks characteristic of short-term well failure.

54 ENVIRONMENTAL SCIENCES↗

Layer-wise Imaging Dataset from Powder Bed Additive Manufacturing Processes for Machine Learning Applications (Peregrine v2022-10)

This release consists of six datasets which together include multi-modal layer-wise powder bed images from two different powder bed printing technologies. These datasets are designed primarily to facilitate the development and testing of new computer vision and machine learning based anomaly and defect detection algorithms. The authors provide both training data with corresponding ground truth pixel masks and evaluation data with corresponding baseline prediction pixel masks made by a trained neural network. The laser powder bed fusion (L-PBF) datasets are sourced from EOS M290 and AddUp FormUp 350 printers and the binder jet (BJ) dataset is sourced from an ExOne M-Flex printer. The materials represented in these datasets include 17-4 PH Stainless Steel, DMREF, Inconel 718, Maraging Steel, and H13 Steel. The sensor imaging modalities represented include visible-light (VL), temporally-integrated (i.e., long duration exposure) near-infrared (TI-NIR), and wide-band infrared (IR).

36 MATERIALS SCIENCE↗

Layer-wise Imaging Dataset from Powder Bed Additive Manufacturing Processes for Machine Learning Applications (Peregrine v2022-10.1)

This release consists of six datasets which together include multi-modal layer-wise powder bed images from two different powder bed printing technologies. These datasets are designed primarily to facilitate the development and testing of new computer vision and machine learning based anomaly and defect detection algorithms. The authors provide both training data with corresponding ground truth pixel masks and evaluation data with corresponding baseline prediction pixel masks made by a trained neural network. The laser powder bed fusion (L-PBF) datasets are sourced from EOS M290 and AddUp FormUp 350 printers and the binder jet (BJ) dataset is sourced from an ExOne M-Flex printer. The materials represented in these datasets include 17-4 PH Stainless Steel, GammaPrint-700, Inconel 718, Maraging Steel, and H13 Steel. The sensor imaging modalities represented include visible-light (VL), temporally-integrated (i.e., long duration exposure) near-infrared (TI-NIR), and wide-band infrared (IR). To download the dataset: (1) Create a Globus account. (2) Create a Globus Endpoint on your computer. (3) Transfer the dataset from the OLCF DOI-DOWNLOADS Collection to your Collection. Common troubleshooting steps: (a) Confirm that the transfer is going from OLCF DOI-DOWNLOADS to your Collection. (b) Create an exception for Globus in your antivirus software so that it can create an Endpoint. (c) Manually create a Globus access directory (where the data will be downloaded) by going to the Preferences > Access tab.

36 MATERIALS SCIENCE↗

2014 Well Completion Report for Corrective Action Unit 447 Project Shoal Area Churchill County, Nevada October 2015

This report summarizes the drilling program conducted by the U.S. Department of Energy (DOE) Office of Legacy Management at the Project Shoal Area (Shoal) Subsurface Corrective Action Unit 447 in Churchill County, Nevada. Shoal was the location of an underground nuclear test conducted on October 26, 1963, as part of the Vela Uniform program sponsored jointly by the U.S. Department of Defense and the U.S. Atomic Energy Commission (a predecessor to DOE). The test consisted of detonating a 12-kiloton nuclear device in granitic rock at a depth of approximately 1,211 feet (ft) below ground surface (bgs) (AEC 1964). The corrective action strategy for the site is focused on revising the site conceptual model and evaluating the adequacy of the monitoring well network at the site. Field activities associated with the project were conducted in accordance with the Federal Facility Agreement and Consent Order (FFACO 1996, as amended) and applicable Nevada Division of Environmental Protection (NDEP) policies and regulations.

54 ENVIRONMENTAL SCIENCES↗

Modeled Performance of the Hathaway Solar Patriot house - Washington D.C

This Dataset contains field research raw data, analysis spreadsheet, photos, and final report from the Hathaway Solar Patriot House Building America Case Study project. This dataset details the monitored and modeled performance of a solar home outside of Washington, D.C. We modeled the home energy performance using DOE 2.2, performed numerous short-terms tests on the home, and monitored its occupied performance for 29 months. The home used modular construction, solar water heating, a ground-coupled heat pump, efficient appliances, and compact fluorescent lighting to reduce its energy consumption by 35% compared to the Building America research benchmark home. The addition of 6kW of photovoltaics (PV) increased the savings to 67% compared to the Building America research benchmark. A more efficient shell to reduce space conditioning loads would have brought the home closer to its zero energy goals. However, even with efficient lighting and appliances, the lights, appliance and plug loads were a significant energy consumer. About 4 kW of PV was required to meet the needs of these loads alone. To achieve the zero energy goal with no further efficiency increases, the Hathaway house would need about 2.6 kW of PV in addition to the 6.0 kW it now has. Applying advanced efficiency measures available or being developed, such as heat-recovery ventilation, superinsulation, and electrochromic windows, could reduce the heating, cooling, and domestic hot water (DHW) energy use to less than 1700 kWh per year, an 88% reduction in these loads from the Building America Benchmark. At this efficiency level, the appliance and plug loads come to dominate energy consumption and account for nearly 70% of the total energy use. This analysis points out that even with highly effective energy-savings technologies (pushed beyond levels currently practical), whole-house energy use reduction by efficiency measures is only about 60% without also reducing the energy use of appliances and plug loads largely considered outside the designers jurisdiction.

Array↗

Thermal Response Testing Takes a Step Forward

Oak Ridge National Labs has independently confirmed the accuracy of a new breakthrough Advanced Thermal Response Test (TRT) method that it claims “uses less than half of the test time, allows for a fluctuating or interruptible heat flux, performs quality validation of a GHEX installation, and yields new insights into ground thermal conductivity that warrant further research.” The new Advanced TRT approach will reduce costs and, for the first time, also determine the actual thermal conductivity of grout as it is installed. As everyone in the ground source heat pump (GSHP) industry knows, assuring the quality of the grout job of a ground heat exchanger (GHEX) is an especially vexing problem. Unless one is standing at the borehole head the entire time grouting is underway, they basically have no idea how good or bad the grouting job is or even if the loop pipe itself is installed correctly. This problem has been further brought to light with formal third party grout reports confirming that grout had been poured from the surface and that many loops were shorter than the specified depth in several projects

58 GEOSCIENCES↗

Electronic excitation of molecules in solution calculated using the symmetry-adapted cluster–configuration interaction method in the polarizable continuum model

The effects from solvent environment are specific to the electronic states; therefore, a computational scheme for solvent effects consistent with the electronic states is necessary to discuss electronic excitation of molecules in solution. The PCM (polarizable continuum model) SAC (symmetry-adapted cluster) and SAC-CI (configuration interaction) methods are developed for such purposes. The PCM SAC-CI adopts the state-specific (SS) solvation scheme where solvent effects are self-consistently considered for every ground and excited states. For efficient computations of many excited states, we develop a perturbative approximation for the PCM SAC-CI method, which is called corrected linear response (cLR) scheme. Our test calculations show that the cLR PCM SAC-CI is a very good approximation of the SS PCM SAC-CI method for polar and nonpolar solvents.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High Temperature Ternary Chloride Molten Salt Pump

This work investigates the design criteria considering thermal, structural, and mate-rial selection of a ternary chloride (MgCl2-NaCl-KCl) molten salt pump that is capable of running at temperatures above 720 °C. In this work, preliminary testing of salt-wetted hydrodynamic bearings was done to investigate different material pairings including colmonoy grades, stellite grades, and a novel NiWC-based alloy (i.e. HybrimetTM NiWC3b) used as a High Velocity Ox-ygen Fuel (HVOF) coating. The coating has shown to withstand the corrosive nature of the salt, and is additionally used to protect a 316L stainless steel pump reservoir. The pump wetted components are made of Inconel 625, and it features a carbon ring seal developed by Flows-erve flooded with a N2 gas flow on the overhead to keep salt vapors from interacting with the external ambient air. This research showcases a promising design for use in the CSP Gen 3 liquid-pathway and sets the ground for further development and use of the HybrimetTM NiWC3b as a competitive alternative to available superalloys. Further work will further characterize the pump by performance & cycle testing in molten salt at higher temperatures.

14 SOLAR ENERGY↗

Electrical design analysis and breakdown voltage test aspects of indigenously developed electrical breaks at Cryo temperatures

Electrical insulation breaks are very critical component of large-scale fusion devices employing superconducting magnets and are used to insulate electrically the coil and the cryogenic supply line (kept at ground potential). The electrical insulation of breaks consists of the composites insulations, G-10 GFRP (Glass fiber reinforced plastic), cryogenic compatible epoxy and S-glass boron free fiber in air and helium environment under vacuum. To optimize the design parameters, the detailed electrical analysis have been carried out using the electrostatic solid axi-symmetric model by COMSOL 4.1 multiphysics software for electrodes separation, electrical field strength as well as flashover phenomenon between two electrodes with composite insulator material have been analyzed at different surfaces and contours along with by varying gaps between SS electrodes. We have carried out the high voltage breakdown test (0-35) kV, insulation resistance measurement at 0-5 kV test voltage in Paschen condition of (10{sup 3} -10{sup -5}) mbar in helium gas and air environment at 300 K and 77 K experimentally on in-house developed insulation breaks. (author)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Method for Selecting Software for Dynamic Event Analysis II: the Taylor Anvil and Dynamic Brazilian Tests

New nuclear power reactor designs will require resistance to a variety of possible malevolent attacks as well as traditional dynamic accident scenarios. The design/analysis team may be faced with a broad range of phenomena including air and ground blasts, high-velocity penetrators or shaped charges, and vehicle or aircraft impacts. With a host of software tools available to address these high-energy events, the analysis team must evaluate and select the software most appropriate for their particular set of problems. The accuracy of the selected software should then be validated with respect to the phenomena governing the interaction of the threat and structure. Several software codes are available for the study of blast, impact, and other shock phenomena. At the Idaho National Laboratory (INL), a study is underway to investigate the comparative characteristics of a group of shock and high-strain rate physics codes including ABAQUS, LS-DYNA, CTH, ALEGRA, and ALE-3D. In part I of this report, a series of five benchmark problems to exercise some important capabilities of the subject software was identified. The benchmark problems selected are a Taylor cylinder test, a split Hopkinson pressure bar test, a free air blast, the dynamic splitting tension (Brazilian) test, and projectile penetration of a concrete slab. Part II-- this paper-- reports the results of two of the benchmark problems: the Taylor cylinder and the dynamic Brazilian test. The Taylor cylinder test is a method to determine the dynamic yield properties of materials. The test specimen is a right circular cylinder which is impacted against a theoretically rigid target. The cylinder deforms upon impact, with the final shape depending upon the dynamic yield stress, in turn a function of strain and strain rate. The splitting tension test, or Brazilian test, is a method to measure the tensile strength of concrete using a cylindrical specimen. The specimen is loaded diametrically in compression, producing a fracture at the center of the specimen that propagates toward the loading points until the cylinder is split. To generate a dynamic load, different methods such as a drop-weight or a split Hopkinson pressure bar are employed. The Taylor anvil and dynamic Brazilian test analyses are presented, including discussion of the analysis approach for each of the five subject software packages; comparison of results both among the codes and to physical test results; and conclusions as to the applicability of the subject codes to these two problems. Studies of the remaining three benchmark problems and overall conclusions will be presented in future reports.

42 ENGINEERING↗

Countdown to perovskite space launch: Guidelines to performing relevant radiation-hardness experiments

Perovskite photovoltaics (PVs) are under intensive development for promise in terrestrial energy production. Soon, the community will find out how much of that promise may become reality. Perovskites also open new opportunities for lower cost space power. However, radiation tolerance of space environments requires appropriate analysis of relevant devices irradiated under representative radiation conditions. We present guidelines designed to rigorously test the radiation tolerance of perovskite PVs. We review radiation conditions in common orbits, calculate nonionizing and ionizing energy losses (NIEL and IEL) for perovskites, and prioritize proton radiation for effective nuclear interactions. Low-energy protons (0.05-0.15 MeV) create a representative uniform damage profile, whereas higher energy protons (commonly used in ground-based evaluation) require significantly higher fluence to accumulate the equivalent displacement damage dose due to lower scattering probability. Furthermore, high-energy protons may "heal" devices through increased electronic ionization. These procedural guidelines differ from those used to test conventional semiconductors.

14 SOLAR ENERGY↗

Local Scrape-Off Layer Control Using Biased electrodes in NSTX

An experiment was designed to test the theory that biased electrodes can affect the local scrape-off layer (SOL) width by creating a strong radial ExB drift [Cohen, R.H. and Ryutov, D.D, Nucl. Fusion 37, 621 (1997)]. These electrodes were located near the outer midplane in the SOL of the National Spherical Torus Experiment (NSTX). The electrodes were biased at up to {+-} 100 Volts, and the radial profile of the plasma between them was measured by an array of Langmuir probes. The biasing caused large changes in the local SOL profiles at least qualitatively consistent with this theory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Record of Technical Change 1 for Closure Report for Corrective Action Unit 543: Liquid Disposal Units, Nevada Test Site, Nevada, Revision 0

ROTC-1: Downgrade FFACO UR at CAU 543, CAS 06-07-01, Decon Pad to an Administrative UR. CAS 06-07-01, Decon Pad, is located at the Decontamination Facility in Area 6. The CAS consists of the effiuent collection and distribution systems for Buildings 6-605, 6-606, and 6-607, which include two 1,000-gallon (gal) septic tanks, two ground-level sumps and associated piping, the concrete foundation of Building 6-605, floor drains, drain trenches, and cleanouts. The Area 6 Decontamination Facility was built in 1971 and was designed to decontaminate vehicles, equipment, and clothing that had become radiologically contaminated during nuclear testing activities. Additionally, the facility managed mixed and radioactive waste generated from these decontamination processes. The Area 6 Decontamination Facility is located along the southwest edge of Yucca Lake in Area 6 of the NNSS. From 1971through1992, hazardous, radioactive, and sanitary wastes were generated within several buildings and originally discharged via process waste lines, septic systems, and sumps to the Area. 6 Decontamination Pond. The Area 6 Decontamination Facility remained operational until 2001, and is currently inactive and abandoned. Additionally, a portion of the facility yard was used as a contaminated materials storage area where equipment and materials awaited decontamination. As a result, portions of the facility yard are posted as "Contamination Areas" (NNSA/NSO, 2004d). During closure activities, the use-restricted area was fenced and posted, and a UR was implemented for PCBs and radioactivity. As best management practices (BMPs ), two septic tanks, two sumps, and their contents were removed and disposed of as mixed waste; sediment from the Building 6-605 floor drain trenches was removed and disposed of as mixed waste; the floor drain trenches, a diversion box, and seven cleanouts were grouted to grade; and numerous containers and other surface debris were segregated according to waste stream and disposed of appropriately as either low-level waste or sanitary waste (NNSA/NSO, 2008). ·

54 ENVIRONMENTAL SCIENCES↗

ADVANCES IN HEXAVALENT CHROMIUM REMOVAL AT HANFORD

At the Hanford Site, chromium was used as a corrosion inhibitor in the reactor cooling water and was introduced into the groundwater as a result of planned and unplanned discharges from reactors during plutonium production since 1944. Beginning in 1995, groundwater treatment methods were evaluated leading to the use of pump and treat facilities with ion exchange using Dowex 21 K, a regenerable strong base anion exchange resin. This required regeneration of the resin, which is currently performed offsite. Resin was installed in a 4 vessel train, with resin removal required from the lead vessel approximately once a month. In 2007, there were 8 trains (32 vessels) in operation. In 2008, DOE recognized that regulatory agreements would require significant expansion in the groundwater chromium treatment capacity. Previous experience from one of the DOE project managers led to identification of a possible alternative resin, and the contractor was requested to evaluate alternative resins for both cost and programmatic risk reductions. Testing was performed onsite in 2009 and 2010, using a variety of potential resins in two separate facilities with groundwater from specific remediation sites to demonstrate resin performance in the specific groundwater chemistry at each site. The testing demonstrated that a weak base anion single-use resin, ResinTech SIR-700, was effective at removing chromium, had a significantly higher capacity, could be disposed of efficiently on site, and would eliminate the complexities and programmatic risks from sampling, packaging, transportation and return of resin for regeneration. This resin was installed in Hanford's newest groundwater treatment facility, called 100-DX, which began operations in November, 2010, and used in a sister facility, 100-HX, which started up in September of 2011. This increased chromium treatment capacity to 25 trains (100 vessels). The resin is also being tested in existing facilities that utilize Dowex 21 K for conversion to the new resin. This paper will describe the results of the testing, performance in the facilities, continued optimization in the pump and treat facilities, and the estimated savings and non-tangible benefits of the conversion.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Results of a Soil Flushing Treatability Test for Hanford Site Hexavalent Chromium Removal - 20446

U.S. Department of Energy contractor CH2M Hill Plateau Remediation Company has made significant progress remediating hexavalent chromium in groundwater near the Columbia River through the operation of pump and treat facilities and source removal activities. To mitigate risks associated with hexavalent chromium contamination, which was identified in a CERCLA interim action record of decision as the primary groundwater contaminant of concern for the 100-KR-4 Operable Unit from discharging to the Columbia River, three ion-exchange pump and treat systems were installed between 1997 and 2009. Between 2010 and 2016, operation of the K West pump and treat system, located near the former 105K West plutonium production reactor, reduced concentrations below the groundwater remediation target for hexavalent chromium. In 2016, a rebound study was performed to evaluate the effectiveness of the pump and treat remedy and assess the potential for any residual hexavalent chromium sources continuing to contribute to groundwater contamination. As a result of the rebound study, a source of continued groundwater contamination was identified. To address this condition, a soil flushing treatability test was written and approved by the U.S. Department of Energy and the U.S. Environmental Protection Agency. The test included saturating about a 1-acre area of soil with treated water with the goal of forcing the residual hexavalent chromium to groundwater where existing extraction wells could remove it for treatment, accelerating the cleanup process. In spring and summer 2019, CH2M Hill Plateau Remediation Company installed and began operating a shallow underground leach system to support the treatability test. Preliminary sampling data show the test was effective in removing the residual contamination. Following further evaluation and analysis from the initial test, the process will be considered for implementation elsewhere on the Hanford Site, particularly at locations where there is a known or suspected continuing contamination source in the soil column. The paper will cover the goals of the study, as well as more details about the following: - Overview of pump and treat exit strategy (using U.S. Environmental Protection Agency guidance); - The design and installation of the soil flushing technology in the 100-K Area; - The testing process and results of sampling data; - Post-study evaluation and potential for implementation in other locations at the Hanford Site. Innovative solutions for cleanup, such as the soil flushing technology, have resulted in substantial progress in the removal of groundwater contaminants at the Hanford Site, potentially shortening the time frame required to meet cleanup goals and resulting in significant cost savings. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗