Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GLANDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

American Society for Radiation Oncology (ASTRO) and American College of Radiology (ACR) Practice Guideline for the Performance of High-Dose-Rate Brachytherapy

High-Dose-Rate (HDR) brachytherapy is a safe and efficacious treatment option for patients with a variety of different malignancies. Careful adherence to established standards has been shown to improve the likelihood of procedural success and reduce the incidence of treatment-related morbidity. A collaborative effort of the American College of Radiology (ACR) and American Society for Therapeutic Radiation Oncology (ASTRO) has produced a practice guideline for HDR brachytherapy. The guideline defines the qualifications and responsibilities of all the involved personnel, including the radiation oncologist, physicist and dosimetrists. Review of the leading indications for HDR brachytherapy in the management of gynecologic, thoracic, gastrointestinal, breast, urologic, head and neck, and soft tissue tumors is presented. Logistics with respect to the brachytherapy implant procedures and attention to radiation safety procedures and documentation are presented. Adherence to these practice guidelines can be part of ensuring quality and safety in a successful HDR brachytherapy program.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Blood Gene Expression Profiling of Breast Cancer Survivors Experiencing Fibrosis

Purpose: To extend knowledge on the mechanisms and pathways involved in maintenance of radiation-induced fibrosis (RIF) by performing gene expression profiling of whole blood from breast cancer (BC) survivors with and without fibrosis 3-7 years after end of radiotherapy treatment. Methods and Materials: Gene expression profiles from blood were obtained for 254 BC survivors derived from a cohort of survivors, treated with adjuvant radiotherapy for breast cancer 3-7 years earlier. Analyses of transcriptional differences in blood gene expression between BC survivors with fibrosis (n = 31) and BC survivors without fibrosis (n = 223) were performed using R version 2.8.0 and tools from the Bioconductor project. Gene sets extracted through a literature search on fibrosis and breast cancer were subsequently used in gene set enrichment analysis. Results: Substantial differences in blood gene expression between BC survivors with and without fibrosis were observed, and 87 differentially expressed genes were identified through linear analysis. Transforming growth factor-{beta}1 signaling was identified as the most significant gene set, showing a down-regulation of most of the core genes, together with up-regulation of a transcriptional activator of the inhibitor of fibrinolysis, Plasminogen activator inhibitor 1 in the BC survivors with fibrosis. Conclusion: Transforming growth factor-{beta}1 signaling was found down-regulated during the maintenance phase of fibrosis as opposed to the up-regulation reported during the early, initiating phase of fibrosis. Hence, once the fibrotic tissue has developed, the maintenance phase might rather involve a deregulation of fibrinolysis and altered degradation of extracellular matrix components.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Lowering Whole-Body Radiation Doses in Pediatric Intensity-Modulated Radiotherapy Through the Use of Unflattened Photon Beams;Flattening filter; Pediatric; Intensity-modulated radiotherapy; Second cancers; Radiation-induced malignancies

Purpose: Intensity modulated radiotherapy (IMRT) has been linked with an increased risk of secondary cancer induction due to the extra leakage radiation associated with delivery of these techniques. Removal of the flattening filter offers a simple way of reducing head leakage, and it may be possible to generate equivalent IMRT plans and to deliver these on a standard linear accelerator operating in unflattened mode. Methods and Materials: An Elekta Precise linear accelerator has been commissioned to operate in both conventional and unflattened modes (energy matched at 6 MV) and a direct comparison made between the treatment planning and delivery of pediatric intracranial treatments using both approaches. These plans have been evaluated and delivered to an anthropomorphic phantom. Results: Plans generated in unflattened mode are clinically identical to those for conventional IMRT but can be delivered with greatly reduced leakage radiation. Measurements in an anthropomorphic phantom at clinically relevant positions including the thyroid, lung, ovaries, and testes show an average reduction in peripheral doses of 23.7%, 29.9%, 64.9%, and 70.0%, respectively, for identical plan delivery compared to conventional IMRT. Conclusions: IMRT delivery in unflattened mode removes an unwanted and unnecessary source of scatter from the treatment head and lowers leakage doses by up to 70%, thereby reducing the risk of radiation-induced second cancers. Removal of the flattening filter is recommended for IMRT treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stereotactic Radiotherapy of Primary Lung Cancer and Other Targets: Results of Consultant Meeting of the International Atomic Energy Agency

To evaluate the current status of stereotactic body radiotherapy (SBRT) and identify both advantages and disadvantages of its use in developing countries, a meeting composed of consultants of the International Atomic Energy Agency was held in Vienna in November 2006. Owing to continuous developments in the field, the meeting was extended by subsequent discussions and correspondence (2007-2010), which led to the summary presented here. The advantages and disadvantages of SBRT expected to be encountered in developing countries were identified. The definitions, typical treatment courses, and clinical results were presented. Thereafter, minimal methodology/technology requirements for SBRT were evaluated. Finally, characteristics of SBRT for developing countries were recommended. Patients for SBRT should be carefully selected, because single high-dose radiotherapy may cause serious complications in some serial organs at risk. Clinical experiences have been reported in some populations of lung cancer, lung oligometastases, liver cancer, pancreas cancer, and kidney cancer. Despite the disadvantages expected to be experienced in developing countries, SBRT using fewer fractions may be useful in selected patients with various extracranial cancers with favorable outcome and low toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interfractional Reproducibility in Pancreatic Position Based on Four-Dimensional Computed Tomography

Purpose: To assess the interfractional positional variation of the pancreas using four-dimensional computed tomography (4D-CT) and to determine the suitable phase of respiration for dose delivery methods to account for pancreatic tumor motion. Methods and Materials: Fifteen patients with pancreatic cancer were enrolled in this study. For each patient, 4D-CT scans were performed at CT simulation and three times during the course of treatment. Regions of interest were set to the intrapancreatic bile ducts as a surrogate for pancreatic position. The centroids of the regions of interest were calculated at end-inhalation and end-exhalation of the respiration phase. The ranges of respiratory motion and interfractional positional variation were evaluated in the left-right (LR), anterior-posterior (AP), and superior-inferior (SI) directions. Results: The medians of respiratory motion were 1.1 mm (range, 0.0-9.8 mm), 1.5 mm (range, 0.0-7.0 mm), and 5.0 mm (range, 0.0-12.5 mm) in the LR, AP, and SI directions, respectively. The means {+-} SDs of the interfractional positional variation at end-inhalation were 0.9 {+-} 5.1 mm (range, -9.2 to 15.6 mm), -1.9 {+-} 3.9 mm (range, -12.8 to 6.4 mm), and -1.3 {+-} 6.9 mm (range, -15.0 to 13.7 mm) and those at end-exhalation were 0.0 {+-} 3.1 mm (range, -7.0 to 5.3 mm), -1.2 {+-} 3.9 mm (range, -11.2 to 6.7 mm), and 0.1 {+-} 3.2 mm (range, -9.9 to 5.1 mm) in the LR, AP, and SI directions, respectively. The SDs of the interfractional positional variation in the LR and SI directions were significantly larger at end-inhalation than at end-exhalation (LR, p < 0.001; SI, p < 0.001). Conclusions: The ranges of respiratory motion during the course of treatment and the interfractional positional variation were not negligible. The interfractional positional reproducibility was higher at end-exhalation than at end-inhalation under free breathing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

2-Methoxyestradiol, an Endogenous Estrogen Metabolite, Sensitizes Radioresistant MCF-7/FIR Breast Cancer Cells Through Multiple Mechanisms

Purpose: The requirement for a well-tolerated and highly effective radiosensitizer that preferentially sensitizes tumor cells at multiple levels of radioresistance remains largely unmet. 2-Methoxyestradiol (2ME) has polypharmacological profiles that target multiple signaling pathways involved in the development of radioresistance. In the current study, we investigated the radiosensitizing effect of 2ME on the radioresistant breast cancer MCF-7/FIR cell line and explored the underlying mechanisms. Methods and Materials: The radiosensitizing effect of 2ME was evaluated on the basis of cell death and clonogenic survival. Formation of reactive oxygen species (ROS), apoptosis, and cell cycle progression were assessed by flow cytometry. Radiation-induced DNA damage was evaluated on the basis of histone {gamma}-H2AX phosphorylation and foci formation. Immunoblotting was used to assess the effects of {gamma} radiation and/or 2ME on radioresistance pathways. Results: Our data demonstrate that MCF-7/FIR cells expressed higher levels of Bcl-2 and HIF-1{alpha} and displayed a lower ROS phenotype than the parental MCF-7 cells. Treatment of parental MCF-7 cells with 2ME (0.5 {mu}M) had minimal effect on {gamma} radiation-induced cell proliferation and surviving fractions. On the contrary, in MCF-7/FIR cells, treatment with 2ME significantly enhanced {gamma} radiation-induced reduction in cell proliferation and surviving fraction. This combination was effective in activating apoptosis, arresting the cell cycle at the G{sub 2}/M phase, and increasing the level of {gamma} radiation-induced ROS and the number of {gamma}-H2AX foci. In addition, 2ME significantly ameliorated {gamma} radiation-induced expression of the HIF-1{alpha} transcription factor and its downstream targets AKT/mTOR. Conclusion: 2ME preferentially sensitizes radioresistant MCF-7/FIR cells to {gamma} radiation by targeting multiple signaling pathways involved in the development of radioresistance. This polypharmacological profile qualifies 2ME as a promising radiosensitizer in the treatment of radioresistant breast cancer cells and warrants systematic preclinical and clinical studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Redox Protein Expression Predicts Radiotherapeutic Response in Early-Stage Invasive Breast Cancer Patients

Purpose: Early-stage invasive breast cancer patients have commonly undergone breast-conserving surgery and radiotherapy. In a large majority of these patients, the treatment is effective; however, a proportion will develop local recurrence. Deregulated redox systems provide cancer cells protection from increased oxidative stress, such as that induced by ionizing radiation. Therefore, the expression of redox proteins was examined in tumor specimens from this defined cohort to determine whether such expression could predict response. Methods and Materials: The nuclear and cytoplasmic expression of nine redox proteins (glutathione, glutathione reductase, glutaredoxin, glutathione peroxidase 1, 3, and 4, and glutathione S-transferase-{theta}, -{pi}, and -{alpha}) was assessed using conventional immunohistochemistry on a tissue microarray of 224 tumors. Results: A high cytoplasmic expression of glutathione S-transferase-{theta} significantly correlated with a greater risk of local recurrence (p = .008) and, when combined with a low nuclear expression (p = .009), became an independent predictive factor (p = .002) for local recurrence. High cytoplasmic expression of glutathione S-transferase-{theta} also correlated with a worse overall survival (p = .009). Low nuclear and cytoplasmic expression of glutathione peroxidase 3 (p = .002) correlated with a greater risk of local recurrence and was an independent predictive factor (p = .005). These proteins did not correlate with tumor grade, suggesting their function might be specific to the regulation of oxidative stress rather than alterations of tumor phenotype. Only nuclear (p = .005) and cytoplasmic (p = .001) expression of glutathione peroxidase 4 correlated with the tumor grade. Conclusions: Our results support the use of redox protein expression, namely glutathione S-transferase-{theta} and glutathione peroxidase 3, to predict the response to radiotherapy in early-stage breast cancer patients. If incorporated into routine diagnostic tests, they have the potential to aid clinicians in their stratification of patients into more tailored treatment regimens. Future targeted therapies to these systems might improve the efficacy of reactive oxygen species-inducing therapies, such as radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automated Planning of Tangential Breast Intensity-Modulated Radiotherapy Using Heuristic Optimization

Purpose: To present an automated technique for two-field tangential breast intensity-modulated radiotherapy (IMRT) treatment planning. Method and Materials: A total of 158 planned patients with Stage 0, I, and II breast cancer treated using whole-breast IMRT were retrospectively replanned using automated treatment planning tools. The tools developed are integrated into the existing clinical treatment planning system (Pinnacle{sup 3}) and are designed to perform the manual volume delineation, beam placement, and IMRT treatment planning steps carried out by the treatment planning radiation therapist. The automated algorithm, using only the radio-opaque markers placed at CT simulation as inputs, optimizes the tangential beam parameters to geometrically minimize the amount of lung and heart treated while covering the whole-breast volume. The IMRT parameters are optimized according to the automatically delineated whole-breast volume. Results: The mean time to generate a complete treatment plan was 6 min, 50 s {+-} 1 min 12 s. For the automated plans, 157 of 158 plans (99%) were deemed clinically acceptable, and 138 of 158 plans (87%) were deemed clinically improved or equal to the corresponding clinical plan when reviewed in a randomized, double-blinded study by one experienced breast radiation oncologist. In addition, overall the automated plans were dosimetrically equivalent to the clinical plans when scored for target coverage and lung and heart doses. Conclusion: We have developed robust and efficient automated tools for fully inversed planned tangential breast IMRT planning that can be readily integrated into clinical practice. The tools produce clinically acceptable plans using only the common anatomic landmarks from the CT simulation process as an input. We anticipate the tools will improve patient access to high-quality IMRT treatment by simplifying the planning process and will reduce the effort and cost of incorporating more advanced planning into clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preclinical Assessment of Volumetric Modulated Arc Therapy for Total Marrow Irradiation

Purpose: A preclinical investigation was undertaken to explore a treatment technique for total marrow irradiation using RapidArc, a volumetric modulated arc technique. Materials and Methods: Computed tomography datasets of 5 patients were included. Plans with eight overlapping coaxial arcs were optimized for 6-MV photon beams. Dose prescription was 12 Gy in 2 Gy per fraction, normalized so that 100% isodose covered 85% of the planning target volume (PTV). The PTV consisted of the whole skeleton (including ribs and sternum), from the top of the skull to the medium distal third of the femurs. Planning objectives for organs at risk (OARs) were constrained to a median dose <6 to 7 Gy. OARs included brain, eyes, oral cavity, parotids, thyroid, lungs, heart, kidneys, liver, spleen, stomach, abdominal cavity, bladder, rectum, and genitals. Pretreatment quality assurance consisted of portal dosimetry comparisons, scoring the delivery to calculation agreement with the gamma agreement index. Results: The median total body volume in the study was 57 liters (range, 49-81 liters), for an average diameter of 47 cm (range, 46-53 cm) and a total length ranging from 95 to 112 cm. The median PTV volume was 6.8 liters (range, 5.8-10.8 liters). The mean dose to PTV was 109% (range, 107-112%). The global mean of median dose to all OARs was 4.9 Gy (range, 4.5-5.1 Gy over the 5 patients). The individual mean of median doses per organ ranged from 2.3 Gy (oral cavity) to 7.3 Gy (bowels cavity). Preclinical quality assurance resulted in a mean gamma agreement index of 94.3 {+-} 5.1%. The delivery time measured from quality assurance runs was 13 minutes. Conclusion: Sparing of normal tissues with adequate coverage of skeletal bones was shown to be feasible with RapidArc. Pretreatment quality assurance measurements confirmed the technical agreement between expected and actually delivered dose distributions, suggesting the possibility of incorporating this technique in the treatment options for patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospective Study of Cone-Beam Computed Tomography Image-Guided Radiotherapy for Prone Accelerated Partial Breast Irradiation

Purpose: To report setup variations during prone accelerated partial breast irradiation (APBI). Methods: New York University (NYU) 07-582 is an institutional review board-approved protocol of cone-beam computed tomography (CBCT) to deliver image-guided ABPI in the prone position. Eligible are postmenopausal women with pT1 breast cancer excised with negative margins and no nodal involvement. A total dose of 30 Gy in five daily fractions of 6 Gy are delivered to the planning target volume (the tumor cavity with 1.5-cm margin) by image-guided radiotherapy. Patients are set up prone, on a dedicated mattress, used for both simulation and treatment. After positioning with skin marks and lasers, CBCTs are performed and the images are registered to the planning CT. The resulting shifts (setup corrections) are recorded in the three principal directions and applied. Portal images are taken for verification. If they differ from the planning digital reconstructed radiographs, the patient is reset, and a new CBCT is taken. Results: 70 consecutive patients have undergone a total of 343 CBCTs: 7 patients had four of five planned CBCTs performed. Seven CBCTs (2%) required to be repeated because of misalignment in the comparison between portal and digital reconstructed radiograph image after the first CBCT. The mean shifts and standard deviations in the anterior-posterior (AP), superior-inferior (SI), and medial-lateral (ML) directions were -0.19 (0.54), -0.02 (0.33), and -0.02 (0.43) cm, respectively. The average root mean squares of the daily shifts were 0.50 (0.28), 0.29 (0.17), and 0.38 (0.20). A conservative margin formula resulted in a recommended margin of 1.26, 0.73, 0.96 cm in the AP, SI, and ML directions. Conclusion: CBCTs confirmed that the NYU prone APBI setup and treatment technique are reproducible, with interfraction variation comparable to those reported for supine setup. The currently applied margin (1.5 cm) adequately compensates for the setup variation detected.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Geometric and Dosimetric Approach to Determine Probability of Late Cardiac Mortality in Left Tangential Breast Irradiation: Comparison Between Wedged Beams and Field-in-Field Technique

Purpose: To evaluate the probability of late cardiac mortality resulting from left breast irradiation planned with tangential fields and to compare this probability between the wedged beam and field-in-field (FIF) techniques and to investigate whether some geometric/dosimetric indicators can be determined to estimate the cardiac mortality probability before treatment begins. Methods and Materials: For 30 patients, differential dose-volume histograms were calculated for the wedged beam and FIF plans, and the corresponding cardiac mortality probabilities were determined using the relative seriality model. As a comparative index of the dose distribution uniformity, the planning target volume (PTV) percentages involved in 97-103% of prescribed dose were determined for the two techniques. Three geometric parameters were measured for each patient: the maximal length, indicates how much the heart contours were displaced toward the PTV, the angle subtended at the center of the computed tomography slice by the PTV contour, and the thorax width/thickness ratio. Results: Evaluating the differential dose-volume histograms showed that the gain in uniformity between the two techniques was about 1.5. With the FIF technique, the mean dose sparing for the heart, the left anterior descending coronary artery, and the lung was 15% (2.5 Gy vs. 2.2 Gy), 21% (11.3 Gy vs. 9.0 Gy), and 42% (8.0 Gy vs. 4.6 Gy) respectively, compared with the wedged beam technique. Also, the cardiac mortality probability decreased by 40% (from 0.9% to 0.5%). Three geometric parameters, the maximal length, angle subtended at the center of the computed tomography slice by the PTV contour, and thorax width/thickness ratio, were the determining factors (p = .06 for FIF, and p = .10 for wedged beam) for evaluating the cardiac mortality probability. Conclusion: The FIF technique seemed to yield a lower cardiac mortality probability than the conventional wedged beam technique. However, although our study demonstrated that FIF technique improved the dose coverage of the PTV, the restricted number of patients enrolled and the short follow-up did not allow us to evaluate and compare the breast cancer survival rates of the patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Association Between Maximal Skin Dose and Breast Brachytherapy Outcome: A Proposal for More Rigorous Dosimetric Constraints

Purpose: Multiple investigations have used the skin distance as a surrogate for the skin dose and have shown that distances <6 mm have been associated with late toxicity after MammoSite brachytherapy. No publications have yet described the relationship between the actual maximal skin dose and the outcome. The present study analyzed the maximal skin dose delivered and the occurrence of late toxicity in a large cohort of patients with prolonged follow-up. Methods: A total of 96 patients treated with breast brachytherapy between 2000 and 2007 for whom complete planning and follow-up data were available were included in the present analysis. The median follow-up was 48 months (range, 24-111). Of the 96 patients, 40 were treated with multicatheter interstitial brachytherapy and 56 with MammoSite. A multivariate statistical analysis was performed to determine the relationship between several dosimetric parameters and patient outcome. Results: The treatment was well tolerated, with 98% of patients experiencing good to excellent cosmesis. Significant late toxicity was uncommon. The maximal dose delivered to the skin was significantly associated with the incidence of any degree of telangiectasia (p = .009) and moderate to severe fibrosis (p = .010). The incidence of late toxicity was significantly increased when the dose to the skin was >4.05 Gy/fraction. Conclusion: The initial skin dose recommendations have been based on safe use and the avoidance of significant toxicity. The results from the present study have suggested that patients might further benefit if more rigorous constraints were applied and if the skin dose were limited to 120% of the prescription dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image-Guided Radiotherapy for Breast Cancer Patients: Surgical Clips as Surrogate for Breast Excision Cavity

Purpose: To determine the use of surgical clips as a surrogate for localization of the excision cavity and to quantify the stability of the clips' positions during the course of external beam radiotherapy for breast cancer patients, using cone beam computed tomography (CBCT) scans. Methods and Materials: Twenty-one breast cancer patients with surgical clips placed in the breast excision cavity were treated in a supine position with 28 daily fractions. CBCT scans were regularly acquired for a setup correction protocol. Retrospectively, the CBCT scans were registered to the planning CT scans, using gray-value registration of the excision cavity region and chamfer matching of the clips. Subsequently, residual setup errors (systematic [{Sigma}] and random [{sigma}]) of the excision cavity were estimated relative to the clips' registration. Finally, the stability of the clips' positions were quantified as the movement of each separate clip according to the center of gravity of the excision cavity. Results: When clips were used for online setup corrections, the residual errors of the excision cavity were {Sigma}{sub left-right} = 1.2, {sigma}{sub left-right} = 1.0; {Sigma}{sub cranial-caudal} = 1.3, {sigma}{sub cranial-caudal} = 1.2; and {Sigma}{sub anterior-posterior} = 0.7, {sigma}{sub anterior-posterior} = 0.9 mm. Furthermore, the average distance (over all patients) between the clips and centers of gravity of the excision cavities was 18.8 mm (on the planning CT) and was reduced to 17.4 mm (measured on the last CBCT scan). Conclusion: Clips move in the direction of the center of gravity of the excision cavity, on average, 1.4 mm. The clips are good surrogates for locating the excision cavity and providing small residual errors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In Vivo Near-Infrared Spectroscopy and Magnetic Resonance Imaging Monitoring of Tumor Response to Combretastatin A-4-Phosphate Correlated With Therapeutic Outcome

Purpose: To develop a combination treatment consisting of combretastatin A-4-phosphate (CA4P) with radiation based on tumor oxygenation status. Methods and Materials: In vivo near-infrared spectroscopy (NIRS) and diffusion-weighted (DW) magnetic resonance imaging (MRI) were applied to noninvasively monitor changes in tumor blood oxygenation and necrosis induced by CA4P (30 mg/kg) in rat mammary 13762NF adenocarcinoma, and the evidence was used to optimize combinations of CA4P and radiation treatment (a single dose of 5 Gy). Results: NIRS showed decreasing concentrations of tumor vascular oxyhemoglobin and total hemoglobin during the first 2 h after CA4P treatment, indicating significant reductions in tumor blood oxygenation and perfusion levels (p < 0.001). Twenty-four hours later, in response to oxygen inhalation, significant recovery was observed in tumor vascular and tissue oxygenation according to NIRS and pimonidazole staining results, respectively (p < 0.05). DW MRI revealed significantly increased water diffusion in tumors measured by apparent diffusion coefficient at 24 h (p < 0.05), suggesting that CA4P-induced central necrosis. In concordance with the observed tumor oxygen dynamics, we found that treatment efficacy depended on the timing of the combined therapy. The most significant delay in tumor growth was seen in the group of tumors treated with radiation while the rats breathed oxygen 24 h after CA4P administration. Conclusions: Noninvasive evaluation of tumor oxygen dynamics allowed us to rationally enhance the response of syngeneic rat breast tumors to combined treatment of CA4P with radiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Outcomes of Breast Cancer Patients With Triple Negative Receptor Status Treated With Accelerated Partial Breast Irradiation

Purpose: Triple negative receptor status (TNRS) of patients undergoing breast-conserving therapy treated with whole-breast irradiation has been associated with increased distant metastasis and decreased disease-free and overall survival. This paper reports the outcomes of TNRS patients treated with accelerated partial breast irradiation (APBI). Methods and Materials: We studied 455 patients who received APBI at our institution, using interstitial, intracavitary, and three-dimensional conformal radiation therapy. TNRS was assigned if a patient tested negative for all three (ER [estrogen receptor], PR [progesterone receptor], and HER2/neu) receptors. Of 202 patients with all receptor results available, 20 patients were designated TNRS, and 182 patients had at least one receptor positive (RP). We analyzed ipsilateral breast tumor recurrence (IBTR), regional nodal failure (RNF), distant metastasis (DM), and overall survival (OS). Results: Mean follow-up was 4.1 years for the TNRS group and 5.1 years for the RP cohort (p = 0.11). TNRS patients had a higher histologic grade (59% TNRS vs. 13% RP; p < 0.001). Mean tumor size, stage N1 disease, and margin status were similar. Based on a 5-year actuarial analysis, the TNRS cohort experienced no IBTR, RNF, or DM, with an OS of 100% versus rates of 1.4% IBTR, 1.5% RNF, and 2.8% DM in the RP cohort (p > 0.52). OS for the RP cohort was 93% at 5 years (p > 0.28). Conclusions: In our patient population, TNRS conferred a clinical outcome similar to that of patients with RP disease treated with APBI. Further investigation with larger patient populations and longer follow-up periods is warranted to confirm that APBI is a safe and effective treatment for patients with localized TNRS breast cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Effect of Adjuvant Postmastectomy Radiotherapy Bolus Technique on Local Recurrence

Purpose: Postmastectomy radiotherapy bolus is heterogenous, with little evidence to guide clinical practise. This study explores the effect of chest wall bolus technique on chest wall recurrence. Methods and Materials: This was a retrospective cohort study of 254 patients treated with adjuvant postmastectomy radiotherapy between 1993 and 2003. Patient and treatment characteristics including bolus details were extracted. Outcomes considered were treatment toxicities, treatment delivery, and local recurrence. Results: In all, 143 patients received radiotherapy with whole chest wall bolus, 88 patients with parascar bolus, and 23 with no bolus. Twenty patients did not complete radiotherapy because of acute skin toxicity: 17 in the whole chest wall bolus group, 2 in the parascar bolus group, and 1 in the group not treated with bolus. On multivariate analysis, whole chest wall bolus and chemotherapy were found to be significant predictors for early cessation of radiotherapy resulting from acute skin toxicity. There were 19 chest wall failures: 13 in the whole chest wall bolus group, 4 in the parascar bolus group, and 2 in the no-bolus group. On multivariate analysis, lymphovascular invasion and failure to complete radiotherapy because of acute skin toxicity were associated with chest wall recurrence. Conclusions: From our results, parascar bolus and no bolus performed no worse than did whole chest wall bolus with regard to chest wall recurrence. However, bolus may have an impact on early cessation of radiotherapy caused by skin toxicity, which then may influence chest wall recurrence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patterns and Risk Factors of Locoregional Recurrence in T1-T2 Node Negative Breast Cancer Patients Treated With Mastectomy: Implications for Postmastectomy Radiotherapy

Purpose: Postmastectomy radiation therapy (PMRT) can reduce locoregional recurrences (LRR) in high-risk patients, but its role in the treatment of lymph node negative (LN-) breast cancer remains unclear. The aim of this study was to identify a subgroup of T1-T2 breast cancer patients with LN- who might benefit from PMRT. Methods and Materials: We retrospectively reviewed 1,136 node-negative T1-T2 breast cancer cases treated with mastectomy without PMRT at the Massachusetts General Hospital between 1980 and 2004. We estimated cumulative incidence rates for LRR overall and in specific subgroups, and used Cox proportional hazards models to identify potential risk factors. Results: Median follow-up was 9 years. The 10-year cumulative incidence of LRR was 5.2% (95% CI: 3.9-6.7%). Chest wall was the most common (73%) site of LRR. Tumor size, margin, patient age, systemic therapy, and lymphovascular invasion (LVI) were significantly associated with LRR on multivariate analysis. These five variables were subsequently used as risk factors for stratified analysis. The 10-year cumulative incidence of LRR for patients with no risk factors was 2.0% (95% CI: 0.5-5.2%), whereas the incidence for patients with three or more risk factors was 19.7% (95% CI: 12.2-28.6%). Conclusion: It has been suggested that patients with T1-T2N0 breast cancer who undergo mastectomy represent a favorable group for which PMRT renders little benefit. However, this study suggests that select patients with multiple risk factors including LVI, tumor size {>=}2 cm, close or positive margin, age {<=}50, and no systemic therapy are at higher risk of LRR and may benefit from PMRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Seed-mediated synthesis, properties and application of {gamma}-Fe{sub 2}O{sub 3}-CdSe magnetic quantum dots

Seed-mediated growth of fluorescent CdSe quantum dots (QDs) around {gamma}-Fe{sub 2}O{sub 3} magnetic cores was performed at high temperature (300 deg. C) in the presence of organic surfactants. Bi-functional magnetic quantum dots (MQDs) with tunable emission properties were successfully prepared. The as-synthesized MQDs were characterized by high-resolution transmission electron microscopy (HRTEM) and dynamic light scattering (DLS), which confirmed the assembly of heterodimers. When a longer growth period was employed, a homogeneous dispersion of QDs around a magnetic nanoparticle was obtained. The magnetic properties of these nanocomposites were examined. The MQDs were superparamagnetic with a saturation magnetization of 0.40 emu/g and a coercivity of 138 Oe at 5 K. To demonstrate their potential application in bio-labeling, these MQDs were coated with a thin silica shell, and functionalized with a polyethylene glycol (PEG) derivative. The functionalized MQDs were effectively used for the labeling of live cell membranes of 4T1 mouse breast cancer cells and HepG2 human liver cancer cells. - Graphical abstract: (a) HRTEM image of oleic acid capped MPs. The size of MPs ranges from 8 to 10 nm. (b) XRD pattern of {gamma}-Fe{sub 2}O{sub 3} MPs. Highlights: > The fabrication of MQDs through a seed-mediated approach has been demonstrated. > The formation and assembly of these bi-functional nanocomposites have been elucidated. > The MQDs exhibit superparamagnetism and tunable emissions characteristic of the components. > MQDs with thin silica coating were successfully employed in the labeling of cancer cell membranes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗