Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Finite-element”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

High-Aperture-Efficiency Horn Antenna

A horn antenna (see Figure 1) has been developed to satisfy requirements specific to its use as an essential component of a high-efficiency Ka-band amplifier: The combination of the horn antenna and an associated microstrip-patch antenna array is required to function as a spatial power divider that feeds 25 monolithic microwave integrated-circuit (MMIC) power amplifiers. The foregoing requirement translates to, among other things, a further requirement that the horn produce a uniform, vertically polarized electromagnetic field in its patches identically so that the MMICs can operate at maximum efficiency. The horn is fed from a square waveguide of 5.9436-mm-square cross section via a transition piece. The horn features cosine-tapered, dielectric-filled longitudinal corrugations in its vertical walls to create a hard boundary condition: This aspect of the horn design causes the field in the horn aperture to be substantially vertically polarized and to be nearly uniform in amplitude and phase. As used here, cosine-tapered signifies that the depth of the corrugations is a cosine function of distance along the horn. Preliminary results of finite-element simulations of performance have shown that by virtue of the cosine taper the impedance response of this horn can be expected to be better than has been achieved previously in a similar horn having linearly tapered dielectric- filled longitudinal corrugations. It is possible to create a hard boundary condition by use of a single dielectric-filled corrugation in each affected wall, but better results can be obtained with more corrugations. Simulations were performed for a one- and a three-corrugation cosine-taper design. For comparison, a simulation was also performed for a linear- taper design (see Figure 2). The three-corrugation design was chosen to minimize the cost of fabrication while still affording acceptably high performance. Future designs using more corrugations per wavelength are expected to provide better field responses and, hence, greater aperture efficiencies.

Pickens, Wesley↗

Dynamics and Controls of a Conceptual Jovian Moon Tour Spacecraft

The dynamics and control challenges presented by a conceptual Jovian Moon Tour spacecraft are summarized in this paper. Attitude and orbital dynamics interactions are present due to the designed low-thrust trajectory, and controls structure interactions are also present due to the non-collocated sensor-actuator pairs on board the flexible spacecraft. A finite-element based simulation model is described which is capable of handling the complex orbital and attitude dynamics arising during the low-thrust spiraling maneuvers of the spacecraft. A few numerical simulations demonstrate that some of the challenges hitherto identified can be faced via integrated dynamics and control analysis, and that reasonable assessments of the pointing performance can be made.

dynamics↗

Explicit Pore Pressure Material Model in Carbon-Cloth Phenolic

An explicit material model that uses predicted pressure in the pores of a carbon-cloth phenolic (CCP) composite has been developed. This model is intended to be used within a finite-element model to predict phenomena specific to CCP components of solid-fuel-rocket nozzles subjected to high operating temperatures and to mechanical stresses that can be great enough to cause structural failures. Phenomena that can be predicted with the help of this model include failures of specimens in restrained-thermal-growth (RTG) tests, pocketing erosion, and ply lifting

Gutierrez-Lemini, Danton↗

NASA Tech Briefs, October 2003

Topics covered include: Cryogenic Temperature-Gradient Foam/Substrate Tensile Tester; Flight Test of an Intelligent Flight-Control System; Slat Heater Boxes for Thermal Vacuum Testing; System for Testing Thermal Insulation of Pipes; Electrical-Impedance-Based Ice-Thickness Gauges; Simulation System for Training in Laparoscopic Surgery; Flasher Powered by Photovoltaic Cells and Ultracapacitors; Improved Autoassociative Neural Networks; Toroidal-Core Microinductors Biased by Permanent Magnets; Using Correlated Photons to Suppress Background Noise; Atmospheric-Fade-Tolerant Tracking and Pointing in Wireless Optical Communication; Curved Focal-Plane Arrays Using Back-Illuminated High-Purity Photodetectors; Software for Displaying Data from Planetary Rovers; Software for Refining or Coarsening Computational Grids; Software for Diagnosis of Multiple Coordinated Spacecraft; Software Helps Retrieve Information Relevant to the User; Software for Simulating a Complex Robot; Software for Planning Scientific Activities on Mars; Software for Training in Pre-College Mathematics; Switching and Rectification in Carbon-Nanotube Junctions; Scandia-and-Yttria-Stabilized Zirconia for Thermal Barriers; Environmentally Safer, Less Toxic Fire-Extinguishing Agents; Multiaxial Temperature- and Time-Dependent Failure Model; Cloverleaf Vibratory Microgyroscope with Integrated Post; Single-Vector Calibration of Wind-Tunnel Force Balances; Microgyroscope with Vibrating Post as Rotation Transducer; Continuous Tuning and Calibration of Vibratory Gyroscopes; Compact, Pneumatically Actuated Filter Shuttle; Improved Bearingless Switched-Reluctance Motor; Fluorescent Quantum Dots for Biological Labeling; Growing Three-Dimensional Corneal Tissue in a Bioreactor; Scanning Tunneling Optical Resonance Microscopy; The Micro-Arcsecond Metrology Testbed; Detecting Moving Targets by Use of Soliton Resonances; and Finite-Element Methods for Real-Time Simulation of Surgery.

Source record↗

Simulation System for Training in Laparoscopic Surgery

A computer-based simulation system creates a visual and haptic virtual environment for training a medical practitioner in laparoscopic surgery. Heretofore, it has been common practice to perform training in partial laparoscopic surgical procedures by use of a laparoscopic training box that encloses a pair of laparoscopic tools, objects to be manipulated by the tools, and an endoscopic video camera. However, the surgical procedures simulated by use of a training box are usually poor imitations of the actual ones. The present computer-based system improves training by presenting a more realistic simulated environment to the trainee. The system includes a computer monitor that displays a real-time image of the affected interior region of the patient, showing laparoscopic instruments interacting with organs and tissues, as would be viewed by use of an endoscopic video camera and displayed to a surgeon during a laparoscopic operation. The system also includes laparoscopic tools that the trainee manipulates while observing the image on the computer monitor (see figure). The instrumentation on the tools consists of (1) position and orientation sensors that provide input data for the simulation and (2) actuators that provide force feedback to simulate the contact forces between the tools and tissues. The simulation software includes components that model the geometries of surgical tools, components that model the geometries and physical behaviors of soft tissues, and components that detect collisions between them. Using the measured positions and orientations of the tools, the software detects whether they are in contact with tissues. In the event of contact, the deformations of the tissues and contact forces are computed by use of the geometric and physical models. The image on the computer screen shows tissues deformed accordingly, while the actuators apply the corresponding forces to the distal ends of the tools. For the purpose of demonstration, the system has been set up to simulate the insertion of a flexible catheter in a bile duct. [As thus configured, the system can also be used to simulate other endoscopic procedures (e.g., bronchoscopy and colonoscopy) that include the insertion of flexible tubes into flexible ducts.] A hybrid approach has been followed in developing the software for real-time simulation of the visual and haptic interactions (1) between forceps and the catheter, (2) between the forceps and the duct, and (3) between the catheter and the duct. The deformations of the duct are simulated by finite-element and modalanalysis procedures, using only the most significant vibration modes of the duct for computing deformations and interaction forces. The catheter is modeled as a set of virtual particles uniformly distributed along the center line of the catheter and connected to each other via linear and torsional springs and damping elements. The interactions between the forceps and the duct as well as the catheter are simulated by use of a ray-based haptic-interaction- simulating technique in which the forceps are modeled as connected line segments.

Basdogan, Cagatay↗

Battery Pack Shape Optimization using Transient Heat Conduction Coupled with Cell-Discharge Analysis

Battery electric systems exhibit significant time-dependence, especially when evaluated in the context of an aircraft mission profile with continually changing power demands. Additionally, when evaluating battery-powered aircraft concepts, it is important to accurately compute the temperature of the batteries and properly characterize the thermal response of the system. The temperature of the batteries has a significant impact on cell performance, in addition to safety considerations of maintaining battery temperatures below their operating limit. Because of these considerations, battery models for preliminary design and optimization of aircraft should include the capability to accurately compute the temperature distribution within the battery pack. Furthermore, battery pack designs should be as light-weight as possible to maximize the pack energy density, while also considering battery temperature limits. Here, we demonstrate a simultaneous trajectory and shape optimization of a battery pack concept, using a transient heat transfer finite element model coupled with a time-varying cell-discharge battery model to provide this capability. Including the transient finite element problem in the loop enables accurate temperatures that can be passed back to the cell discharge model, while the cell discharge model can supply the finite element model with time-varying heat boundary conditions to the finite element problem, further benefiting the fidelity of the thermal response of the batteries. We first demonstrate the coupling capability between the battery cell-discharge model and the transient finite-element heat transfer through an optimization which computes the optimal current profile for the battery pack while ensuring the battery temperatures remain below their operational limit. We then build on this optimization by adding shape optimization to the problem, which allows us to consider a composite objective function which also minimizes the mass of the battery pack, while also producing an optimal current discharge profile.

Optimization↗

Microwave Debinding of Ceramics Produced by Additive Manufacturing

Microwave-assisted debinding offers an innovative approach to processing 3D-printed engineering ceramics. Ceramic parts produced with photopolymer-based additive manufacturing techniques require thermal debinding to remove polymers that bind ceramic particles during the printing process. Microwave-assisted debinding significantly reduces processing times and offers energy savings over conventional thermal treatments due to higher heating rates and more uniform heating. Finite-element modeling of the debinding process allows for the optimization and prediction of temperature distribution, stress development, and potential defects, leading to improved process control and material quality.

36 - MATERIALS SCIENCE↗

Minimization of thermal deformation in crystal optics for high repetition-rate FEL

Minimizing thermal deformation in X-ray crystal optics is crucial for preserving coherence and wavefront in high-repetition-rate free-electron lasers (FELs). This study presents two approaches to reduce pulse-by-pulse transient thermal deformation in diamond crystals used in cavity-based X-ray FELs (CBXFELs): (1) cryogenic cooling with liquid nitrogen (LN₂), and (2) second-order correction via focusing optics. We revisit the temperature-dependent thermal-mechanical properties of diamond and silicon, implement a finite-element analysis (FEA) method to accelerate convergence to a quasisteady-state regime. Results show that LN₂-cooled diamond crystals meet the stringent deformation requirement of less than 15 pm RMS for the pulse at mJ scale at 1 MHz repetition frequency, and up to 1.5 mJ for 100 kHz. Second-order correction by using focusing elements within the cavity can reduce the impact of thermal deformation for both liquid nitrogen and water cooling.

free electron laser↗

Novel Design and Fabrication of a High Frequency Transient Heat Flux Sensor for Use in an RDE

Rotating detonation engine (RDE) combustion systems have been a topic of interest in the pressure gain combustion community for their benefits over traditional gas turbine engine combustors. However, cooling requirements for these engines are significantly higher and less predictable than non-detonating engines. To understand the high-speed heat transfer dynamics inside an RDE, a novel, high-frequency heat flux gage is presented. This study aims to design a robust, single-sided sensor that can withstand the high temperature and harsh environment of an RDE for extended durations. Sensor bench testing is performed using a hot plate as a heat source, and the sensor response is compared to a finite-element analysis (FEA) model. The sensor response is then tested inside a water-cooled RDE and the wall heat flux is compared to calorimetry data.

rotating detonation engines↗

Broad frequency tuning of a Nb$_{3}$Sn superconducting microwave cavity for dark matter searches

We demonstrate a novel broad-frequency tuning mechanism for superconducting microwave cavities designed for dark matter searches. Using a Nb$_3$Sn-coated cigar-shaped cavity operating at approximately 9 GHz, we achieve continuous frequency tuning exceeding 1 GHz by mechanically separating the two cavity halves: a "tuning-by-opening" technique. Finite-element method simulations predict that radiative losses do not degrade the quality factor even for large openings, as a closed cavity with an intrinsic quality factor of $10^7$ maintains this value for apertures up to 9 mm, corresponding to a tuning range from 9.0 to 7.5 GHz. Experimental validation using both copper ring spacers and a continuous sliding mechanism confirms $Q_0$ values exceeding the dark matter quality factor across the entire explored frequency range, despite mechanical imperfections and film non-uniformities. This tuning approach avoids inserting elements into the resonant volume, making it particularly suitable for high-Q superconducting cavities in axion haloscope experiments and readily applicable to REBCO-based implementations capable of operating in multi-tesla magnetic fields.

Maiello, D. [Padua U.; INFN, Padua] (ORCID:0009000↗

Optimal Hairpin Winding Configuration for EV Traction Motors to Enhance Active CMV Cancellation Capability of NPL.X Inverter

Active common-mode voltage (CMV) cancellation in neutral-point-less (NPL.X) inverter is an effective approach for reducing common-mode electromagnetic interference and alleviating voltage stress associated with high-speed switching in EV traction drives. However, the existing hairpin winding configuration often exhibits impedance imbalance due to slot leakage inductance and manufacturing constraints, limiting the effectiveness of active CMV cancellation. This paper investigates symmetric hairpin winding configurations for a dual-three-phase EV traction machine to improve impedance symmetry. Considering the manufacturing constraints of six-layer hairpin windings, four feasible symmetric winding configurations are analyzed. Two-dimensional finite-element analysis is performed to extract the impedance parameters of each configuration. The extracted impedance parameters are used to quantify the impedance mismatch between complementary phase pairs and evaluate its influence on active CMV cancellation. The results show that the fully interleaved winding configuration achieves perfectly balanced phase impedances with 0 % mismatch, whereas the mismatch in the other configurations ranges from approximately 2.4 % to 0.8 %. Consequently, the resulting total CMV overshoot is significantly suppressed to near zero voltage under high-voltage and high switching frequency operating conditions, demonstrating the importance of winding symmetry for maximizing the active CMV cancellation capability of the NPL.X inverter.

Lee, Kangbeen [Purdue Univ., West Lafayette, IN (U↗

In-Situ Magnetic Field Reconstruction in the MAGIS-100 Experiment

Long-baseline atom interferometers such as the Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) require stringent control and continuous characterization of background magnetic fields and spatial gradients to prevent systemic phase shifts that mimic ultralight dark matter or gravitational wave signatures. Because direct sensor placement within the ultra-high vacuum beam pipe is infeasible, in-situ magnetic field monitoring relies on external sensor arrays situated in the surrounding annular region. This work demonstrates a field reconstruction framework for a 5.3-meter MAGIS-100 modular section using finite-element Opera simulations. Transverse magnetic fields are expanded using a cylindrical multipole framework as informed by Fermilab’s Muon g-2 experiment, with magnetometer array configurations optimized via Fisher information matrix D-optimality. Inverting external sensor readings through a Gauss-Newton scheme recovers interior tube fields across distinct axial positions. In the discontinuity-averse uniform region (slice pair P4), the model achieves sub-noise-floor performance with a cross-validated root-mean-square error (RMSE) of $6.7227 \times 10^{-4}\text{ A/m}$ ($0.845\times$ sensor noise floor) and an interior field coefficient of variation of $1.71\%$. An elbow criterion in the Fisher bounds establishes $n_{\text{max}} = 2$ as the optimal multipole truncation order to prevent noise amplification from over-parameterization, with $n_{\text{max}} = 3$ (sextupole) order chosen for analysis to demonstrate further complexity and cross-pair comparison. Furthermore, analytical differentiation of the fitted multipole coefficients yields dense spatial maps of the transverse Jacobian gradient matrix $\nabla \mathbf{H}$ along with propagated $1\sigma$ uncertainty bounds across the beam region ($r \le 2.75\text{ in}$). This operational framework confirms that external magnetometer arrays can reliably monitor magnetic field uniformity and spatial gradients along the 100-meter flight path given appropriate sampling for any complexity order.

Appleby, Darwin [William Rainey Harper Coll.; Ferm↗

Physics-based stabilized finite element approximations of the Poisson–Nernst–Planck equations

We present and analyze two stabilized finite element methods for solving numerically the Poisson–Nernst–Planck equations. The stabilization we consider is carried out by using a shock detector and a discrete graph Laplacian operator for the ion equations, whereas the discrete equation for the electric potential need not be stabilized. Discrete solutions stemmed from the first algorithm preserve both maximum and minimum discrete principles. For the second algorithm, its discrete solutions are conceived so that they hold discrete principles and obey an entropy law provided that an acuteness condition is imposed for meshes. Remarkably the latter is found to be unconditionally stable. We validate our methodology through transient numerical experiments that show convergence toward steady-state solutions.

97 MATHEMATICS AND COMPUTING↗

Polynomial range estimation as a troubled-cell indicator for high-order methods

Two troubled-cell indicators based on polynomial range estimation methods are used to flag cells that may violate positivity constraints. One method uses interval extension, and the second uses the range enclosure property of the Bernstein polynomial basis. Furthermore, both methods reduce compute time for the positivity preserver by limiting its application to a subset of cells. The Bernstein polynomial method remains effective as the problem dimensionality increases. Interval extension applied to the internal energy equation permits the use of the troubled-cell indicators for rational functions, though performance suffers compared to directly applying the indicators to polynomial functions.

42 ENGINEERING↗

X-point effects on the ideal MHD modes in tokamaks in the description of dual-poloidal-region safety factor

The flux coordinates with dual-region safety factor (q) in the poloidal direction are developed in this work. The X-point effects on the ideal MHD modes in tokamaks are then analyzed using this coordinate system. Since the X-point effects mainly affect the edge region, the modes localized at the tokamak edge are particularly examined. Two types of modes are studied. The first is related to the conventional peeling or peeling-ballooning modes. The mode existence aligned with the local magnetic field in the poloidally core region as observed experimentally is confirmed. The X points are shown to contribute to a stabilizing effect for the conventionally treated modes with the surface-averaged q and with the tokamak edge portion truncated. The other is the axisymmetric modes localized in the vicinity of X points, which can affect the cross-field-line transport near the X points. The existence of axisymmetric modes points to the possibility of applying a toroidally axisymmetric resonant magnetic perturbation (RMP) in the X-point area for mitigating the edge localized modes, which can be an alternative to the current RMP design. The dual q description also has important implications for the existing non-axisymmetric RMP concept. It helps to understand why the RMP suppression of edge localized modes is difficult to achieve in the double-null tokamak configurations and points to the possibility of further improving the current RMP concept by considering the alignment to the local q.

Fourier analysis↗

Full-field quantitative visualization of shock-driven pore collapse and failure modes in PMMA

The dynamic collapse of pores under shock loading is thought to be directly related to hot spot generation and material failure, which is critical to the performance of porous energetic and structural materials. However, the shock compression response of porous materials at the local, individual pore scale is not well understood. This study examines, quantitatively, the collapse phenomenon of a single spherical void in PMMA at shock stresses ranging from 0.4 to 1.0 GPa. Using a newly developed internal digital image correlation technique in conjunction with plate impact experiments, full-field quantitative deformation measurements are conducted in the material surrounding the collapsing pore for the first time. The experimental results reveal two failure mode transitions as shock stress is increased: (i) the first in situ evidence of shear localization via adiabatic shear banding and (ii) dynamic fracture initiation at the pore surface. Numerical simulations using thermo-viscoplastic dynamic finite element analysis provide insights into the formation of adiabatic shear bands (ASBs) and stresses at which failure mode transitions occur. Further numerical and theoretical modeling indicates the dynamic fracture to occur along the weakened material inside an adiabatic shear band. Finally, analysis of the evolution of pore asymmetry and models for ASB spacing elucidate the mechanisms for the shear band initiation sites, and elastostatic theory explains the experimentally observed ASB and fracture paths based on the directions of maximum shear.

42 ENGINEERING↗

A three-dimensional laser ray-tracing methodology for radiation-hydrodynamics simulations

We report on a methodology for performing laser ray-tracing in three spatial dimensions for radiation-hydrodynamics simulation codes. Our method, which is an extension of that developed in Haines et al., Comput. Fluids 201, 104478 (2020), utilizes an automatically generated separate mesh for the laser ray-tracing from the radiation-hydrodynamics mesh. This enables the laser mesh to be tailored to minimize ray noise with significantly fewer rays than would be required when the ray-tracing is performed on the radiation-hydrodynamics mesh, primarily by allowing the use of high-aspect-ratio cells that are not suitable for hydrodynamics solvers. For a planar target, we show that our method provides a ≈ 100× reduction in computational expense to achieve a fixed level of ray noise relative to ray-tracing directly on the radiation-hydrodynamics mesh. The relatively low ray requirement also enables efficient computation of cross-beam energy transfer. Each cell in the logically cubic laser mesh is a non-convex dodecahedron with triangular sides, and numerical integration of the ray trajectories and inverse bremsstrahlung is performed by mapping each cell to the unit cube. We will describe our methodology in detail as well as its implementation in the xRAGE radiation-hydrodynamics code, discuss performance, and present the results from applying the methodology to test problems with analytic solutions for laser ray-tracing through a quadratic density gradient with an analytic solution as well as for a laser-driven heat front. In 3D radiation-hydrodynamics simulations of laser-driven experiments performed on the National Ignition Facility, laser ray-tracing with our methodology uses less than 1% of total computational time while introducing acceptably low levels of ray noise.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Assessment of errors in analytic modeling of permanent magnet electron spectrometers for laser-plasma accelerators

Here, we assess the error in three treatments of a critical electron beam diagnostic for laser-plasma acceleration (LPA) experiments: a permanent magnet electron spectrometer. Since LPA electron spectrometers are often difficult to calibrate due to the scarcity of well-characterized, tunable electron beam sources in the appropriate energy range and the mechanical complexity of electron spectrometers, the standard of calibration is Hall probe measurements. We first compare the electron spectrometer performance between SIMION calculations and the Hall probe measurements. We find up to a 60% (<8%) error in determining the absolute energy for electrons below (above) 80 MeV when using the SIMION-modeled magnetic field vs the measured magnetic field due to SIMION overpredicting fringe field strength. The difference in spectrometer energy resolution is within ∼10% between the modeled and measured fields. We then assess a simple block model, which is commonly used. We find that the simple block model presented here sufficiently captures the predicted as-built spectrometer performance for any application provided that the user can tolerate uncertainties on absolute energy determination up to 5% and errors on energy resolution up to 1%.

Electromagnetic optics↗