Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Failure Rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Abnormalities of the QT interval in primary disorders of autonomic failure

BACKGROUND: Experimental evidence shows that activation of the autonomic nervous system influences ventricular repolarization and, therefore, the QT interval on the ECG. To test the hypothesis that the QT interval is abnormal in autonomic dysfunction, we examined ECGs in patients with severe primary autonomic failure and in patients with congenital dopamine beta-hydroxylase (DbetaH) deficiency who are unable to synthesize norepinephrine and epinephrine. SUBJECTS AND METHODS: Maximal QT and rate-corrected QT (QTc) intervals and adjusted QTc dispersion [(maximal QTc - minimum QTc on 12 lead ECG)/square root of the number of leads measured] were determined in blinded fashion from ECGs of 67 patients with primary autonomic failure (36 patients with multiple system atrophy [MSA], and 31 patients with pure autonomic failure [PAF]) and 17 age- and sex-matched healthy controls. ECGs of 5 patients with congenital DbetaH deficiency and 6 age- and sex-matched controls were also analyzed. RESULTS: Patients with MSA and PAF had significantly prolonged maximum QTc intervals (492+/-58 ms(1/2) and 502+/-61 ms(1/2) [mean +/- SD]), respectively, compared with controls (450+/-18 ms(1/2), P < .05 and P < .01, respectively). A similar but not significant trend was observed for QT. QTc dispersion was also increased in MSA (40+/-20 ms(1/2), P < .05 vs controls) and PAF patients (32+/-19 ms(1/2), NS) compared with controls (21+/-5 ms(1/2)). In contrast, patients with congenital DbetaH deficiency did not have significantly different RR, QT, QTc intervals, or QTc dispersion when compared with controls. CONCLUSIONS: Patients with primary autonomic failure who have combined parasympathetic and sympathetic failure have abnormally prolonged QT interval and increased QT dispersion. However, QT interval in patients with congenital DbetaH deficiency was not significantly different from controls. It is possible, therefore, that QT abnormalities in patients with primary autonomic failure are not solely caused by lesions of the sympathetic nervous system, and that the parasympathetic nervous system is likely to have a modulatory role in ventricular repolarization.

Non-NASA Center↗

Automatically adaptive stabilized finite elements and continuation analysis for compaction banding in geomaterials

Under compressive creep, viscoplastic solids experiencing internal mass transfer processes can accommodate singular cnoidal wave solutions as material instabilities at the stationary wave limit. These instabilities appear when the loading rate is significantly faster than the material's capacity to diffusive internal perturbations, leading to localized failure features (e.g., cracks and compaction bands). These cnoidal waves, generally found in fluids, have strong nonlinearities that produce periodic patterns. Due to the singular nature of the solutions, the applicability of the theory is currently limited. Additionally, practical simulation tools require proper regularization to overcome the challenges that singularity induces. We focus on the numerical treatment of the governing equation using a nonlinear approach building on a recent adaptive stabilized finite element method. This automatic refinement method provides an error estimate that drives mesh adaptivity, a crucial feature for the problem at hand. We compare the performance of this adaptive strategy against analytical and standard finite element solutions. We then investigate the sensitivity of the diffusivity ratio, the parameter controlling the process, and identify multiple possible solutions with several stress peaks. We also show the evolution of the spacing between peaks for all solutions as a function of that parameter.

42 ENGINEERING↗

Constitutive model development of aluminum alloy 1100 for elevated temperature forming process

Commercially pure aluminum alloy, AA1100, presents good electrical and thermal conductivity, high formability, and low cost. Those favorable characteristics have the potential to enable bipolar plates with improved economics and enhanced performance compared to current stainless steel bipolar plates for proton exchange membrane fuel cells. An accurate constitutive model is essential to develop and optimize processing parameters and effectively control the forming process. Here, the objective of this work is to develop a constitutive model of AA1100 that is able to simulate stress-strain relation, formed geometry, and predict the onset of fracture strain to avoid forming failure. Initially, a set of tensile tests at temperature between 300 and 500°C and strain rate between 0.005 and 1.0/s were conducted to examine the deformation behavior. Then, a set of damage-based unified visco-plastic constitutive equations is proposed and calibrated based on the results of stress-strain data. A genetic algorithm optimization method is applied to search for best fitting material constants in constitutive equations. The proposed model shows good predictability of both the stress-strain relation and fracture strain at low strain rate and high temperature conditions. The accuracy of proposed model is also evaluated statistically. A comparison of the proposed model with three popular models (Arrhenius-type mode, Johnson-Cook model and Zerilli-Armstrong model) was made. The proposed model shows the best experimental agreement with correlation coefficient of 0.96 in contrast to 0.25, 0.38 and 0.75 for the popular models, respectively. The proposed model can help to optimize the elevated temperature forming process and guide die design to enable optimal geometric features in the formed components.

08 HYDROGEN↗

Robust constrained tension control for high-precision roll-to-roll processes

Tension control is critical for maintaining good product quality in most roll-to-roll (R2R) production systems. Previous work has primarily focused on improving the disturbance rejection performance of tension controllers. Here, a robust linear parameter-varying model predictive control (LPV-MPC) scheme is designed to enhance the tension tracking performance of a pilot R2R system for deposition of materials used in flexible thin film applications. The performance of a tension controller may degrade due to disturbances associated with model uncertainties and the slowly-changing dynamics in R2R systems. We introduce a method that separately treats these two sources of disturbance. The controller utilizes an incremental model to eliminate the errors caused by the mismatch between the nominal model and the actual system. A tube-based MPC formulation combined with scheduled parameters adequately updates models and corrects for the time-varying dynamics. Constraints on the rated motor torque are incorporated in the MPC to maintain the controller reliability and avoid machine failures. We illustrate the operation of our control algorithm through simulation of an actual R2R system. The controller outperforms the benchmarks in terms of fast transient response and offset-free tension tracking. Furthermore, it also demonstrates immunity from variations due to parametric uncertainties.

42 ENGINEERING↗

Thermal shielding by subliming volume reflectors in convective and intense radiative environments.

The behavior of dielectric materials having densely packed internal scattering centers subject to extreme convective and radiative environments is analyzed. Experiments have shown that these materials act as volume reflectors of incident radiation even when the exposed surface is being eroded by thermochemical ablation. The analysis was applied to interpret experiments of subliming Teflon models exposed to combined radiative and convective fluxes up to 1.7 kW/sq cm for several seconds. Results show that, although the exposed surface receded at an apparently steady rate, the internal temperature climbed continually, due to internal absorption of radiation and would have caused failure internally if the test duration were extended a few seconds. Thus, performance is time-limited by the internal absorption coefficient. Results were obtained for larger configurations and other materials. Typically, Teflon shells may withstand radiant fluxes up to 20 kW/sq cm for about 5 sec and fritted quartz up to 50 kW/sq cm for about 8 sec (corresponding to the Jupiter entry).

Howe, J. T.↗

Reliability-based optimum inspection and maintenance procedures

The development of reliability-based optimum inspection and maintenance schedules for engines needs an understanding of the fatigue behavior of the engines. Critical areas of the engine structure prone to fatigue damage are usually identified beforehand or after the fleet has been put into operation. In these areas, fatigue cracks initiate after several flight hours, and these cracks grow in length until failure takes place when these cracks attain the critical lengths. Crack initiation time and its growth rate are considered to be random variables. Usually, the inspection (fatigue) or test data from similar engines are used as prior distributions. The existing state-of-the-art is to ignore the different lengths of cracks obserbed at various inspections and to consider only the fact that a crack existed (or did not exist) at the time of inspection. In this paper, a procedure has been developed to obtain the probability of finding a crack of a given size at a certain time if the probability distributions for crack initiation and rates of growth are known. Application of the developed stochastic models to devise optimum procedures for inspection and maintenance are also discussed.

Nanagud, S.↗

Progress in the development of the hollow fiber sodium-sulfur secondary cell

This report describes the development and status of the sodium-sulfur secondary cell which uses fine hollow glass fibers as the electrolyte. Laboratory size cells containing up to 7000 fibers and having capacities up to 5 ampere-hours have been built and operated. These cells have been run at various cycle depths up to 95% of capacity. Lifetime does not depend on depth of discharge up to at least 50% depth and possibly deeper. Rates of charge and discharge of the nominally one hour cells have been varied from three times the design rate to 0.05 times the design rate. Smaller cells operate with essentially no internal resistance increase during their lifetimes of over four months on continuous charge/discharge at the one hour rate. Larger cells assembled with somewhat different mechanical assembly techniques have shorter lives. Two types of failure modes are observed: progressive weakening and breaking of the fibers inside the cell assembly, and fiber breakage at the fiber/tube sheet interface.

Levine, C. A.↗

Effect of gyro verticality error on lateral autoland tracking performance for an inertially smoothed control law

The results of a simulation study performed to determine the effects of gyro verticality error on lateral autoland tracking and landing performance are presented. A first order vertical gyro error model was used to generate the measurement of the roll attitude feedback signal normally supplied by an inertial navigation system. The lateral autoland law used was an inertially smoothed control design. The effect of initial angular gyro tilt errors (2 deg, 3 deg, 4 deg, and 5 deg), introduced prior to localizer capture, were investigated by use of a small perturbation aircraft simulation. These errors represent the deviations which could occur in the conventional attitude sensor as a result of the maneuver-induced spin-axis misalinement and drift. Results showed that for a 1.05 deg per minute erection rate and a 5 deg initial tilt error, ON COURSE autoland control logic was not satisfied. Failure to attain the ON COURSE mode precluded high control loop gains and localizer beam path integration and resulted in unacceptable beam standoff at touchdown.

Thibodeaux, J. J.↗

Acoustic emission monitoring crack propagation in single crystal silicon

The feasibility of acoustic emission (AE) monitoring of cracking and crack propagation in Si semiconductor materials was evaluated experimentally. A double torsion load relaxation method was employed wherein the propagation velocity and the AE levels in precracked (but not notched) boron-doped wafers were recorded simultaneously. A numerical model for the critical stress intensity factor (KIC) was used to relate the crack growth velocity, the instantaneous load and the load relaxation rate. All specimens were monitored with acoustic transducers at six points and examined with SEM after failure. The AE levels reached a peak amplitude of 70 dB at a KIC of 0.997 MNm to the -3/2 for cracking in the 111 plane. No AE was detected before the load reached the KIC, indicating that no subcritical crack growth occurs in Si. The results support the use of AE for monitoring crack propagation in crystal Si.

Chen, C. P.↗

Status of the NASA balloon program

The U.S. National Aeronautics and Space Administration (NASA) Balloon Program has been highly successful since recovering from the catastrophic balloon failure problems of the early to mid 1980s. Balloons have continued to perform at unprecedented success rates. The comprehensive research and development (R&D) effort has continued with advances being made across the spectrum of balloon related disciplines. The long duration balloon project will be transitioning from a development effort to an operational capability this year. Recently, emphasis has been placed on the development and implementation of new support systems and facilities. A new permanent launch facility at Fort Sumner, New Mexico has been established. New ground station support equipment is being implemented, and a new heavy load launch vehicle is scheduled to be implemented in 1992. The progress, status and future plans for these and other aspects of the NASA program will be presented.

Needleman, H. C.↗

Aperture Valve for the Mars Organic Molecule Analyzer (MOMA)

NASA's participation in the multi-nation ExoMars 2018 Rover mission includes a critical astrobiology Mass Spectrometer Instrument on the Rover called the Mars Organic Molecule Analyzer (MOMA). The Aperture Valve is a critical electromechanical valve used by the Mass Spectrometer to facilitate the transfer of ions from Martian soil to the Mass Spectrometer for analysis. The MOMA Aperture Valve development program will be discussed in terms of the Initial valve design and subsequent improvements that resulted from prototype testing. The Initial Aperture Valve concept seemed promising, based on calculations and perceived merits. However, performance results of this design were disappointing, due to delamination of TiN and DLC coatings applied to the Titanium base metals, causing debris from the coatings to seize the valve. While peer reviews and design trade studies are important forums to vet a concept design, results from testing should not be underestimated.Despite the lack of development progress to meet requirements, valuable information from weakness discovered in the Initial Valve design was used to develop a second, more robust Aperture valve. Based on a check-ball design, the ETU flight valve design resulted in significantly less surface area to create the seal. Moreover, PVD coatings were eliminated in favor of hardened, nonmagnetic corrosion resistant alloys. Test results were impressive, with the valve achieving five orders of magnitude better sealing leak rate over end of life requirements. Cycle life was equally impressive, achieving 280,000 cycles without failure.

Mars↗

Aperture Valve for the Mars Organic Molecule Analyzer (MOMA)

NASA's participation in the multi-nation ExoMars 2018 Rover mission includes a critical astrobiology Mass Spectrometer Instrument on the Rover called the Mars Organic Molecule Analyzer (MOMA). The Aperture Valve is a critical electromechanical valve used by the Mass Spectrometer to facilitate the transfer of ions from Martian soil to the Mass Spectrometer for analysis. The MOMA Aperture Valve development program will be discussed in terms of the Initial valve design and subsequent improvements that resulted from prototype testing. The Initial Aperture Valve concept seemed promising, based on calculations and perceived merits. However, performance results of this design were disappointing, due to delamination of TiN and DLC coatings applied to the Titanium base metals, causing debris from the coatings to seize the valve. While peer reviews and design trade studies are important forums to vet a concept design, results from testing should not be underestimated. Despite the lack of development progress to meet requirements, valuable information from weakness discovered in the Initial Valve design was used to develop a second, more robust Aperture valve. Based on a check-ball design, the ETU /flight valve design resulted in significantly less surface area to create the seal. Moreover, PVD coatings were eliminated in favor of hardened, nonmagnetic corrosion resistant alloys. Test results were impressive, with the valve achieving five orders of magnitude better sealing leak rate over end of life requirements. Cycle life was equally impressive, achieving 280,000 cycles without failure.

00000↗

Aperture Valve for the Mars Organic Molecule Analyzer (MOMA)

NASA's participation in the multi-nation ExoMars 2018 Rover mission includes a critical astrobiology Mass Spectrometer Instrument on the Rover called the Mars Organic Molecule Analyzer (MOMA). The Aperture Valve is a critical electromechanical valve used by the Mass Spectrometer to facilitate the transfer of ions from Martian soil to the Mass Spectrometer for analysis. The MOMA Aperture Valve development program will be discussed in terms of the initial valve design and subsequent improvements that resulted from prototype testing. The initial Aperture Valve concept seemed promising, based on calculations and perceived merits. However, performance results of this design were disappointing, due to delamination of TiN and DLC coatings applied to the titanium base metals, causing debris from the coatings to seize the valve. While peer reviews and design trade studies are important forums to vet a concept design, results from testing should not be underestimated. Despite the lack of development progress to meet requirements, valuable information from weakness discovered in the initial Valve design was used to develop a second, more robust Aperture Valve. Based on a check-ball design, the ETU / flight valve design resulted in significantly less surface area to create the seal. Moreover, PVD coatings were eliminated in favor of hardened, non-magnetic corrosion resistant alloys. Test results were impressive, with the valve achieving five orders of magnitude better sealing leak rate over end of life requirements. Cycle life was equally impressive, achieving 280,000 cycles without failure.

Engler, Charles↗

Orbiter post-tire failure and skid testing results

An investigation was conducted at the NASA Langley Research Center's Aircraft Landing Dynamics Facility (ALDF) to define the post-tire failure drag characteristics of the Space Shuttle Orbiter main tire and wheel assembly. Skid tests on various materials were also conducted to define their friction and wear rate characteristics under higher speed and bearing pressures than any previous tests. The skid tests were conducted to support a feasibility study of adding a skid to the orbiter strut between the main tires to protect an intact tire from failure due to overload should one of the tires fail. Roll-on-rim tests were conducted to define the ability of a standard and a modified orbiter main wheel to roll without a tire. Results of the investigation are combined into a generic model of strut drag versus time under failure conditions for inclusion into rollout simulators used to train the shuttle astronauts.

Daugherty, Robert H.↗

Intermediate Temperature Stress Rupture of Woven SiC Fiber, BN Interphase, SiC Matrix Composites in Air

Tensile stress-rupture experiments were performed on woven Hi-Nicalon reinforced SiC matrix composites with BN interphases in air. Modal acoustic emission (AE) was used to monitor the damage accumulation in the composites during the tests and microstructural analysis was performed to determine the amount of matrix cracking that occurred for each sample. Fiber fractograph), was also performed for individual fiber failures at the specimen fracture surface to determine the strengths at which fibers failed. The rupture strengths were significantly worse than what would have been expected front the inherent degradation of the fibers themselves when subjected to similar rupture conditions. At higher applied stresses the rate of rupture "?as larger than at lower applied stresses. It was observed that the change in rupture rate corresponded to the onset of through-thickness cracking in the composites themselves. The primary cause of the sen,ere degradation was the ease with which fibers would bond to one another at their closest separation distances, less than 100 nanometers, when exposed to the environment. The near fiber-to-fiber contact in the woven tows enabled premature fiber failure over large areas of matrix cracks due to the stress-concentrations created b), fibers bonded to one another after one or a few fibers fail. i.e. the loss of global load sharing. An@, improvement in fiber-to-fiber separation of this composite system should result in improved stress- rupture properties. A model was den,eloped in order to predict the rupture life-time for these composites based on the probabilistic nature of indin,idual fiber failure at temperature. the matrix cracking state during the rupture test, and the rate of oxidation into a matrix crack. Also incorporated into the model were estimates of the stress-concentration that would occur between the outer rim of fibers in a load-bearing bundle and the unbridged region of a matrix crack after Xia et al. For the lower stresses, this source of stress-concentration was the likely cause for initial fiber failure that would trigger catastrophic failure of the composite.

Morscher, Gregory N.↗

Some Aspects of the Failure Mechanisms in BaTiO3-Based Multilayer Ceramic Capacitors

The objective of this presentation is to gain insight into possible failure mechanisms in BaTiO3-based ceramic capacitors that may be associated with the reliability degradation that accompanies a reduction in dielectric thickness, as reported by Intel Corporation in 2010. The volumetric efficiency (microF/cm3) of a multilayer ceramic capacitor (MLCC) has been shown to not increase limitlessly due to the grain size effect on the dielectric constant of ferroelectric ceramic BaTiO3 material. The reliability of an MLCC has been discussed with respect to its structure. The MLCCs with higher numbers of dielectric layers will pose more challenges for the reliability of dielectric material, which is the case for most base-metal-electrode (BME) capacitors. A number of MLCCs manufactured using both precious-metal-electrode (PME) and BME technology, with 25 V rating and various chip sizes and capacitances, were tested at accelerated stress levels. Most of these MLCCs had a failure behavior with two mixed failure modes: the well-known rapid dielectric wearout, and so-called 'early failures." The two failure modes can be distinguished when the testing data were presented and normalized at use-level using a 2-parameter Weibull plot. The early failures had a slope parameter of Beta >1, indicating that the early failures are not infant mortalities. Early failures are triggered due to external electrical overstress and become dominant as dielectric layer thickness decreases, accompanied by a dramatic reduction in reliability. This indicates that early failures are the main cause of the reliability degradation in MLCCs as dielectric layer thickness decreases. All of the early failures are characterized by an avalanche-like breakdown leakage current. The failures have been attributed to the extrinsic minor construction defects introduced during fabrication of the capacitors. A reliability model including dielectric thickness and extrinsic defect feature size is proposed in this presentation. The model can be used to explain the Intel-reported reliability degradation in MLCCs with respect to the reduction of dielectric thickness. It can also be used to estimate the reliability of a MLCC based on its construction and microstructure parameters such as dielectric thickness, average grain size, and number of dielectric layers. Measures for preventing early failures are also discussed in this document.

Liu, David Donhang↗

Verification and Validation of a Three-Dimensional Composite Impact Model with Tabulated Input

A material model which incorporates several key capabilities which have been identified by the aerospace community as lacking in the composite impact models currently available in the commercial transient dynamic finite element code LS-DYNA® has been developed. The material model utilizes experimentally based tabulated input to define the evolution of plasticity and damage as opposed to specifying discrete input parameters (such as modulus and strength. The plasticity portion of the orthotropic, three-dimensional, macroscopic composite constitutive model is based on an extension of the Tsai-Wu composite failure model into a generalized yield function with a non-associative flow rule. The capability to account for the rate and temperature dependent deformation response of composites has also been incorporated into the material model. For the damage model, a strain equivalent formulation is utilized to allow for the uncoupling of the deformation and damage analyses. In the damage model, a diagonal damage tensor is defined to account for the directionally dependent variation of damage. However, the terms in the damage matrix are semi-coupled such that the damage in a particular coordinate direction is a function of the stresses and plastic strains in all of the coordinate directions. For the failure model, a tabulated approach is utilized in which a stress or strain based invariant is defined as a function of the location of the current stress state in stress space to define the initiation of failure, which allows an arbitrarily shaped failure surface to be defined. A systematic series of validation and verification studies, at a variety of length scales ranging from single element simulations to simulations of a flat panel impact test, have been performed to fully exercise and evaluate the capabilities of the developed model.

Impact↗

Fracture and failure: Analyses, mechanisms and applications; Proceedings of the Symposium, Los Angeles, CA, March 17-20, 1980

Papers are presented on the application of fracture mechanics to spacecraft design, fracture control applications on the Space Shuttle reaction control thrusters, and an assessment of fatigue crack growth rate relationships for metallic airframe materials. Also considered are fracture mechanisms and microstructural relationships in Ni-base alloy systems, the use of surface deformation markings to determine crack propagation directions, case histories of metallurgical failures in the electronics industry, and a failure analysis of silica phenolic nozzle liners.

Tung, P. P.↗