Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLUORESCENCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Observation of ultralow-level Al impurities on a silicon surface by high-resolution grazing emission x-ray fluorescence excited by synchrotron radiation

We demonstrate that ultralow-level Al impurities on a silicon surface can be measured by using the high-resolution grazing emission x-ray fluorescence (GEXRF) technique combined with synchrotron-radiation excitation. An Al-impurity level of about 10{sup 12} atoms/cm{sup 2} was reached by observing the Al K{alpha} x-ray fluorescence in the resonant Raman-scattering background-''free'' regime by choosing an appropriate beam energy below the Si K absorption edge. Present results show that by combining the GEXRF method with the vapor phase decomposition technique the 10{sup 7} atoms/cm{sup 2} level can be reached for Al detection on silicon. Finally, we found that the high-resolution GEXRF technique is a sensitive tool to study the morphology of surface nanostructures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fast-scanning high-flux microprobe for biological X-ray fluorescence microscopy and microXAS

There is a growing interest in the biomedical community in obtaining information concerning the distribution and local chemical environment of metals in tissues and cells. Recently, biological X-ray fluorescence microscopy (XFM) has emerged as the tool of choice to address these questions. A fast-scanning high-flux X-ray microprobe, built around a recently commissioned pair of 200 mm-long Rh-coated silicon Kirkpatrick-Baez mirrors, has been constructed at BioCAT beamline 18ID at the Advanced Photon Source. The new optical system delivers a flux of 1.3 x 10{sup 12} photons s{sup -1} into a minimum focal spot size of {approx}3-5 {micro}m FWHM. A set of Si drift detectors and bent Laue crystal analyzers may be used in combination with standard ionization chambers for X-ray fluorescence measurements. BioCAT's scanning software allows fast continuous scans to be performed while acquiring and storing full multichannel analyzer spectra per pixel on-the-fly with minimal overhead time (<20 ms per pixel). Together, the high-flux X-ray microbeam and the rapid-scanning capabilities of the BioCAT beamline allow the collection of XFM and micro X-ray absorption spectroscopy (microXAS) measurements from as many as 48 tissue sections per day. This paper reports the commissioning results of the new instrument with representative XFM and microXAS results from tissue samples.

43 PARTICLE ACCELERATORS↗

Development of a single-cell X-ray fluorescence flow cytometer

An X-ray fluorescence flow cytometer that can determine the total metal content of single cells has been developed. Capillary action or pressure was used to load cells into hydrophilic or hydrophobic capillaries, respectively. Once loaded, the cells were transported at a fixed vertical velocity past a focused X-ray beam. X-ray fluorescence was then used to determine the mass of metal in each cell. By making single-cell measurements, the population heterogeneity for metals in the µ M to m M concentration range on fL sample volumes can be directly measured, a measurement that is difficult using most analytical methods. This approach has been used to determine the metal composition of 936 individual bovine red blood cells (bRBC), 31 individual 3T3 mouse fibroblasts (NIH3T3) and 18 Saccharomyces cerevisiae (yeast) cells with an average measurement frequency of ~4 cells min –1 . These data show evidence for surprisingly broad metal distributions. Lastly, details of the device design, data analysis and opportunities for further sensitivity improvement are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the Search for Nuclear Resonance Fluorescence Signatures of 235U and 238U above 3 MeV

Abstract–Nuclear resonance fluorescence is a physical process that provides an isotope-specific signature that could be used for the identification and characterization of materials. The technique involves the detection of prompt discrete-energy photons emitted from a sample that is exposed to photons in the MeV energy range. Potential applications of the technique range from detection of high explosives to characterization of special nuclear materials such as 235U. Pacific Northwest National Laboratory and Passport Systems have collaborated to conduct a a pair of measurements to search for a nuclear resonance fluorescence response of 235U above 3 MeV and of 238U above 5 MeV using an 8 g sample of highly enriched uranium and a 90 g sample of depleted uranium. No new signatures were observed. The minimum detectable integrated cross section for 235U is presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

On the Search for Nuclear Resonance Fluorescence Signatures of 235U and 238U above 3 MeV

Nuclear resonance fluorescence is a physical process that provides an isotope-specific signature that could be used for the identification and characterization of materials. The technique involves the detection of prompt discrete-energy photons emitted from a sample that is exposed to MeV-energy photons. Potential applications of the technique range from detection of high explosives to characterization of special nuclear materials such as 235U. Pacific Northwest National Laboratory and Passport Systems have collaborated to conduct a pair of measurements to search for a nuclear resonance fluorescence response of 235U above 3 MeV and of 238U above 5 MeV using an 8 g sample of highly enriched uranium and a 90 g sample of depleted uranium. No new signatures were observed. The minimum detectable integrated cross section for 235U is presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The physiological basis for estimating photosynthesis from Chl>em>a fluorescence

We report solar-induced Chl fluorescence (SIF) offers the potential to curb large uncertainties in the estimation of photosynthesis across biomes and climates, and at different spatiotemporal scales. However, it remains unclear how SIF should be used to mechanistically estimate photosynthesis. In this study, we built a quantitative framework for the estimation of photosynthesis, based on a mechanistic light reaction model with the Chla fluorescence of Photosystem II (SIFPSII) as an input (MLR-SIF). Utilizing 29 C 3 and C 4 plant species that are representative of major plant biomes across the globe, we confirmed the validity of this framework at the leaf level. The MLR-SIF model is capable of accurately reproducing photosynthesis for all C 3 and C 4 species under diverse light, temperature, and CO 2 conditions. We further tested the robustness of the MLR-SIF model using Monte Carlo simulations, and found that photosynthesis estimates were much less sensitive to parameter uncertainties relative to the conventional Farquhar, von Caemmerer, Berry (FvCB) model because of the additional independent information contained in SIF PSII . Once inferred from direct observables of SIF, SIF PSII provides ‘parameter savings’ to the MLR-SIF model, compared to the mechanistically equivalent FvCB model, and thus avoids the uncertainties arising as a result of imperfect model parameterization. Our findings set the stage for future efforts to employ SIF mechanistically to improve photosynthesis estimates across a variety of scales, functional groups, and environmental conditions.

59 BASIC BIOLOGICAL SCIENCES↗

Inference of photosynthetic capacity parameters from chlorophyll a fluorescence is affected by redox state of PSII reaction centers

Solar-induced chlorophyll fluorescence (SIF) has been used to infer photosynthetic capacity parameters (e.g., the maximum carboxylation rate V cmax , and the maximum electron transport rate J max ). However, the precise mechanism and practical utility of such approach under dynamic environments remain unclear. In this study, we used the balance between the light and carbon reactions to derive theoretical equations relating chlorophyll a fluorescence (ChlF) emission and photosynthetic capacity parameters, and formulated testable hypotheses regarding the dynamic relationships between the true total ChlF emitted from PSII (SIF PSII ) and V cmax and J max . We employed concurrent measurements of gas exchanges and ChlF parameters for 15 species from six biomes to test the formulated hypotheses across species, temperatures, and limitation state of carboxylation. Our results revealed that SIF PSII alone is incapable of informing the variations in V cmax and J max across species, even when SIF PSII is determined under the same environmental conditions. In contrast, the product of SIF PSII and the fraction of open PSII reactions q L , which indicates the redox state of PSII, is a strong predictor of both V cmax and J max , although their precise relationships vary somewhat with environmental conditions. Our findings suggest the redox state of PSII strongly influences the relationship between SIF PSII and V cmax and J max .

59 BASIC BIOLOGICAL SCIENCES↗

Experimental and theoretical dosimetry of a new polymer encapsulated iodine-125 source--SmartSeed: Dosimetric impact of fluorescence x rays

Purpose: The detailed study of a new permanent iodine-125 brachytherapy source, SmartSeed, is presented in this article. It is the first iodine seed made with biocompatible polymer and is manufactured by the IBt-Bebig group. Methods: Three dosimetric studies have been performed: The first one used thermoluminescent detectors in a solid water phantom with NIST (National Institute of Standards and Technology, USA) calibrated seeds, and two separate studies were of Monte Carlo photon transport calculations (MCNP5 code). The TG-43U1 protocol was applied to derive dosimetric parameters for clinical applications. Results: The radial dose function g(r) was determined at different distances ranging from 0.5 to 10 cm; and the anisotropy function F(r,{theta}) at angles ranging from 0 deg. to 350 deg. in 10 deg. increments. Monte Carlo calculations were performed in liquid water to obtain values for {Lambda}, g(r), F(r,{theta}), and {phi}{sub an}(r) as recommended by the TG-43U1 protocol for use in treatment planning system software. SmartSeed's biocompatible polymer capsule permits fluorescence x rays (3, 5, and 12 keV), generated by lead glass marker, to be present in the emission spectrum, influencing the dose rate constant. The impact on near field dosimetry in water from these x rays was also investigated and reported. The capsule also attenuates iodine-125 energies much less than typical titanium encased sources, resulting in a highly isotropic source. Conclusions: SmartSeed has a dose rate constant of 0.895{+-}7.3% cGy h{sup -1} U{sup -1}, a radial dose function nearly identical to the IBt-Bebig model I25.S06 seed, and a highly isotropic dose distribution. Fluorescence x rays account for the relatively low value of {Lambda}, yet their variable contribution to dosimetry arising from seed dimensional uncertainties is estimated to be <0.2%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-H-206-03: Promises and Challenges of Benchtop X-Ray Fluorescence CT (XFCT) for Quantitative in Vivo Imaging

Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly to biomedical research during the past decade. The initial development was an extension of clinical PET/CT and SPECT/CT from human to small animals and combine the unique functional information obtained from PET and SPECT with anatomical information provided by the CT in registered multi-modality images. The requirements to image a mouse whose size is an order of magnitude smaller than that of a human have spurred advances in new radiation detector technologies, novel imaging system designs and special image reconstruction and processing techniques. Examples are new detector materials and designs with high intrinsic resolution, multi-pinhole (MPH) collimator design for much improved resolution and detection efficiency compared to the conventional collimator designs in SPECT, 3D high-resolution and artifact-free MPH and sparse-view image reconstruction techniques, and iterative image reconstruction methods with system response modeling for resolution recovery and image noise reduction for much improved image quality. The spatial resolution of PET and SPECT has improved from ∼6–12 mm to ∼1 mm a few years ago to sub-millimeter today. A recent commercial small animal SPECT system has achieved a resolution of ∼0.25 mm which surpasses that of a state-of-art PET system whose resolution is limited by the positron range. More recently, multimodality SA PET/MRI and SPECT/MRI systems have been developed in research laboratories. Also, multi-modality SA imaging systems that include other imaging modalities such as optical and ultrasound are being actively pursued. In this presentation, we will provide a review of the development, recent advances and future outlook of multi-modality molecular imaging of small animals. Learning Objectives: To learn about the two major multi-modality molecular imaging techniques of small animals. To learn about the spatial resolution achievable by the molecular imaging systems for small animal today. To learn about the new multi-modality imaging instrumentation and techniques that are being developed. Sang Hyun Cho; X-ray fluorescence (XRF) imaging, such as x-ray fluorescence computed tomography (XFCT), offers unique capabilities for accurate identification and quantification of metals within the imaging objects. As a result, it has emerged as a promising quantitative imaging modality in recent years, especially in conjunction with metal-based imaging probes. This talk will familiarize the audience with the basic principles of XRF/XFCT imaging. It will also cover the latest development of benchtop XFCT technology. Additionally, the use of metallic nanoparticles such as gold nanoparticles, in conjunction with benchtop XFCT, will be discussed within the context of preclinical multimodal multiplexed molecular imaging. Learning Objectives: To learn the basic principles of XRF/XFCT imaging To learn the latest advances in benchtop XFCT development for preclinical imaging Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; L. Wang, Funding Support: NIH; COI: Microphotoacoustics; S. Cho, Yes: ;NIH/NCI grant R01CA155446 DOD/PCRP grant W81XWH-12-1-0198.

60 APPLIED LIFE SCIENCES↗

TH-AB-209-01: Making Benchtop X-Ray Fluorescence Computed Tomography (XFCT) Practical for in Vivo Imaging by Integration of a Dedicated High-Performance X-Ray Source in Conjunction with Micro-CT Functionality

Purpose: To make benchtop x-ray fluorescence computed tomography (XFCT) practical for routine preclinical imaging tasks with gold nanoparticles (GNPs) by deploying, integrating, and characterizing a dedicated high-performance x-ray source and addition of simultaneous micro-CT functionality. Methods: Considerable research effort is currently under way to develop a polychromatic benchtop cone-beam XFCT system capable of imaging GNPs by stimulation and detection of gold K-shell x-ray fluorescence (XRF) photons. Recently, an ad hoc high-power x-ray source was incorporated and used to image the biodistribution of GNPs within a mouse, postmortem. In the current work, a dedicated x-ray source system featuring a liquid-cooled tungsten-target x-ray tube (max 160 kVp, ∼3 kW power) was deployed. The source was operated at 125 kVp, 24 mA. The tube’s compact dimensions allowed greater flexibility for optimizing both the irradiation and detection geometries. Incident x-rays were shaped by a conical collimator and filtered by 2 mm of tin. A compact “OEM” cadmium-telluride x-ray detector was implemented for detecting XRF/scatter spectra. Additionally, a flat panel detector was installed to allow simultaneous transmission CT imaging. The performance of the system was characterized by determining the detection limit (10-second acquisition time) for inserts filled with water/GNPs at various concentrations (0 and 0.010–1.0 wt%) and embedded in a small-animal-sized phantom. The phantom was loaded with 0.5, 0.3, and 0.1 wt% inserts and imaged using XFCT and simultaneous micro-CT. Results: An unprecedented detection limit of 0.030 wt% was experimentally demonstrated, with a 33% reduction in acquisition time. The reconstructed XFCT image accurately localized the imaging inserts. Micro-CT imaging did not provide enough contrast to distinguish imaging inserts from the phantom under the current conditions. Conclusion: The system is immediately capable of in vivo preclinical XFCT imaging with GNPs. Micro-CT imaging will require optimization of irradiation parameters to improve contrast. Supported by NIH/NCI grant R01CA155446; This investigation was supported by NIH/NCI grant R01CA155446.

60 APPLIED LIFE SCIENCES↗

Analysis of the Spectral Composition of Fluorescence from Laser-Excited Cold Atomic Clouds

A consistent quantum approach is used to calculate the signal of fluorescence from a laser-excited cold atomic ensemble. The possibility of analyzing the spectral composition of this nonstationary signal is investigated. Application of wavelet transforms is shown to be a very efficient method that allows achieving a good spectral or temporal resolution, depending on specific problem. On the basis of this approach, the spectral composition of fluorescence and its dynamics after excitation are studied. The spectral properties of the secondary emission of the ensemble are compared for different directions and polarizations.

74 ATOMIC AND MOLECULAR PHYSICS↗

Fluorescence of Zinc Complex with N,N'-Bis(5-Bromosalicylidene)Ethylenediamine

A Zn(II) complex with N,N'-bis(5-bromosalicylidene)ethylenediamine exhibiting intense visible blue luminescence is synthesized. It is found that the zinc complex fluoresces at 293 K in both polycrystalline form and in solutions (λ{sub max} = 440 and 450 nm, respectively); the relative fluorescence quantum yields of the complex are determined in dilute ethanol, dimethylformamide, and dimethylsulfoxide solutions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mutation L232H Promotes Chromophore Maturation of EGFP-Based Fluorescent Fusion Proteins

The L232H mutant of the enhanced green fluorescent protein (EGFP) was expressed and crystallized. An X-ray diffraction data set was collected from the crystals to 1.53 Å resolution. An analysis of the three-dimensional structure revealed a stacking interaction between the amino-acid residues Н78 and Н232, which contributes to the fastening of the C-terminal region of the protein in the vicinity of the chromophore and influences chromophore maturation of hybrid fluorescent proteins produced by fusion of the target proteins with the C-terminus of EGFP. This hypothesis was experimentally confirmed by investigating chromophore maturation of the hybrid proteins fused to the N- and C-termini of EGFP and EGFP-L232H.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Anomalous scattering, transport, and spatial distribution of X-ray fluorescence at the exit of polycapillary structures

The angular distribution of the X-ray intensity at the exit of microchannel plates at grazing incidence of monochromatic radiation on the walls of microcapillaries has been investigated. The angles and energies of the primary radiation quanta at which the synchrotron beam excites X-ray fluorescence propagating inside polycapillary structures have been determined. The angular dependences of the intensity distribution of X-rays transmitted through the microcapillaries have been studied theoretically and experimentally for energies corresponding to the region of anomalous dispersion near the L{sub 2,3} absorption edges of silicon. The propagation of waves in hollow polycapillary waveguides, the excitation of X-ray fluorescence, and the X-ray diffraction at the exit of microchannel plates have been modeled mathematically. The mathematical model takes into account the presence of a transition layer on the microchannel surface.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fluorescence excited in a thunderstorm atmosphere by relativistic runaway electron avalanches

The spectrum and spatiotemporal evolution of the fluorescence of an atmospheric discharge developing in the regime of relativistic runaway electron avalanche (RREA) generation have been calculated without involving the relativistic feedback. The discharges generating narrow bipolar pulses, along with the discharges responsible for terrestrial gamma-ray flashes, are shown to be relatively dark. Nevertheless, the fluorescence excited by a discharge involving RREAs can be recorded with cameras used to record high-altitude optical phenomena. A possible connection between a certain class of optical phenomena observed at the tops of thunderclouds and RREA emission is pointed out.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of magnetic field on the character of fluorescence of dense and cold atomic ensembles excited by pulsed radiation

Specific features of fluorescence of dense and cold nondegenerate atomic ensembles in an external constant magnetic field are analyzed theoretically. The angular distribution, polarization properties, as well as the spectral composition of fluorescence radiation are calculated. The time variation of these characteristics after the end of the excitation pulse is analyzed. The dependence of the properties of secondary radiation on the duration and carrier frequency of the pulse is investigated. It is shown that, for dense clouds in which the free path length of quasiresonance photons is commensurate with the interatomic distance, the magnetic field significantly modifies all the observable properties of the radiation. Under these conditions, the trapping time may increase by tens of times. Magnetic field enhances the effect of quantum beats observed on time scales commensurate with the lifetime of the excited states of atoms. For individual polarization channels, this field also intensifies the phenomenon of coherent backscattering (CBS). The phenomena found are explained by the effect of magnetic field on the character of resonance dipole–dipole interaction and, as a result, on the specific features of collective phenomena in dense atomic ensembles.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurements of the Plasma Parameters in a Mirror Trap by Means of Laser-Induced Fluorescence

Results of measurements of the absolute density of ArII ions in a mirror trap with a toroidal divertor are presented. The ion density was measured by the method of laser-induced fluorescence with the use of ArII metastable states. A technique is proposed to estimate the plasma electron temperature from the ratio of the fluorescence signals obtained by comparing the intensities of different optical transitions of ArII.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Polarized Fluorescence in Indole under Two-Photon Excitation by Femtosecond Laser Pulses

We have analyzed the decay of fluorescence intensity in indole dissolved in propylene glycol under two-photon excitation by linearly and circularly polarized femtosecond laser pulses in the wavelength range 475–510 nm. The dependences of fluorescence intensity I{sub 0}, anisotropy r, and parameter Ω on the excitation energy have been determined and analyzed. In particular, a nonmonotonic behavior of I{sub 0} indicating the increase of indole excited state density in the excitation energy range above 5.1 eV and the anisotropy sign reversal due to the variation of the symmetry of indole vibronic states have been observed and interpreted theoretically.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗