Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Wavelength measurement of n=3 to n=3 transitions in highly charged tungsten ions

3s{sub 1/2}-3p{sub 3/2} and 3p{sub 1/2}-3d{sub 3/2} transitions have been studied in potassiumlike W{sup 55+} through neonlike W{sup 64+} ions at the electron-beam ion trap facility in Livermore. The wavelengths of the lines have been measured in high resolution relative to well known reference lines from oxygen and nitrogen ions. Using the high-energy SuperEBIT electron-beam ion trap and an R=44.3 m grazing-incidence soft-x-ray spectrometer, the lines were observed with a cryogenic charge-coupled device camera. The wavelength data for the sodiumlike and magnesiumlike tungsten lines are compared with theoretical predictions for ions along the isoelectronic sequences.

74 ATOMIC AND MOLECULAR PHYSICS↗

Measuring tides and binary parameters from gravitational wave data and eclipsing timings of detached white dwarf binaries

The discovery of the most compact detached white dwarf (WD) binary SDSS J065133.33+284423.3 has been discussed in terms of probing the tidal effects in WDs. This system is also a verification source for the space-based gravitational wave (GW) detector, eLISA, or the evolved Laser Interferometer Space Antenna, which will observe short-period compact Galactic binaries with P {sub orb} ≲ 5 hr. We address the prospects of performing tidal studies using eLISA binaries by showing the fractional uncertainties in the orbital decay rate, f-dot , and the rate of that decay, f{sup ¨} expected from both the GW and electromagnetic (EM) data for some of the high-f binaries. We find that f-dot and f{sup ¨} can be measured using GW data only for the most massive WD binaries observed at high frequencies. From timing the eclipses for ∼10 yr, we find that f-dot can be known to ∼0.1% for J0651. We find that from GW data alone, measuring the effects of tides in binaries is (almost) impossible. We also investigate the improvement in the knowledge of the binary parameters by combining the GW amplitude and inclination with EM data with and without f-dot . In our previous work, we found that EM data on distance constrained the 2σ uncertainty in chirp mass to 15%-25% whereas adding f-dot reduces it to 0.11%. EM data on f-dot also constrain the 2σ uncertainty in distance to 35%-19%. EM data on primary mass constrain the secondary mass m {sub 2} to factors of two to ∼40% whereas adding f-dot reduces this to 25%. Finally, using single-line spectroscopic data constrains 2σ uncertainties in both the m {sub 2}, d to factors of two to ∼40%. Adding EM data on f-dot reduces these 2σ uncertainties to ≤25% and 6%-19%, respectively. Thus we find that EM measurements of f-dot and radial velocity are valuable in constraining eLISA binary parameters.

79 ASTRONOMY AND ASTROPHYSICS↗

Systematic errors in low-latency gravitational wave parameter estimation impact electromagnetic follow-up observations

Among the most eagerly anticipated opportunities made possible by Advanced LIGO/Virgo are multimessenger observations of compact mergers. Optical counterparts may be short-lived so rapid characterization of gravitational wave (GW) events is paramount for discovering electromagnetic signatures. One way to meet the demand for rapid GW parameter estimation is to trade off accuracy for speed, using waveform models with simplified treatment of the compact objects’ spin. We report on the systematic errors in GW parameter estimation suffered when using different spin approximations to recover generic signals. Component mass measurements can be biased by >5σ using simple-precession waveforms and in excess of 20σ when non-spinning templates are employed. This suggests that electromagnetic observing campaigns should not take a strict approach to selecting which LIGO/Virgo candidates warrant follow-up observations based on low-latency mass estimates. For sky localization, we find that searched areas are up to a factor of ∼2 larger for non-spinning analyses, and are systematically larger for any of the simplified waveforms considered in our analysis. Distance biases for the non-precessing waveforms can be in excess of 100% and are largest when the spin angular momenta are in the orbital plane of the binary. We confirm that spin-aligned waveforms should be used for low-latency parameter estimation at the minimum. Including simple precession, though more computationally costly, mitigates biases except for signals with extreme precession effects. Our results shine a spotlight on the critical need for development of computationally inexpensive precessing waveforms and/or massively parallel algorithms for parameter estimation.

79 ASTRONOMY AND ASTROPHYSICS↗

THE SOLAR X-RAY CONTINUUM MEASURED BY RESIK

The solar X-ray continuum emission at five wavelengths between 3.495 A and 4.220 A for 19 flares in a 7-month period in 2002-2003 was observed by the RESIK (REntgenovsky Spektrometr s Izognutymi Kristalami) crystal spectrometer on CORONAS-F. In this wavelength region, free-free and free-bound emissions have comparable fluxes. With a pulse-height analyzer having settings close to optimal, the fluorescence background was removed so that RESIK measured true solar continuum in these bands with an uncertainty in the absolute calibration of +-20%. With an isothermal assumption, and temperature and emission measure derived from the ratio of the two GOES channels, the observed continuum emission normalized to an emission measure of 10{sup 48} cm{sup -3} was compared with theoretical continua using the CHIANTI atomic code. The accuracy of the RESIK measurements allows photospheric and coronal abundance sets, important for the free-bound continuum, to be discriminated. It is found that there is agreement to about 25% of the measured continua with those calculated from CHIANTI assuming coronal abundances in which Mg, Si, and Fe abundances are four times photospheric.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A bronchoscopic navigation system using bronchoscope center calibration for accurate registration of electromagnetic tracker and CT volume without markers

Purpose: Various bronchoscopic navigation systems are developed for diagnosis, staging, and treatment of lung and bronchus cancers. To construct electromagnetically navigated bronchoscopy systems, registration of preoperative images and an electromagnetic tracker must be performed. This paper proposes a new marker-free registration method, which uses the centerlines of the bronchial tree and the center of a bronchoscope tip where an electromagnetic sensor is attached, to align preoperative images and electromagnetic tracker systems. Methods: The chest computed tomography (CT) volume (preoperative images) was segmented to extract the bronchial centerlines. An electromagnetic sensor was fixed at the bronchoscope tip surface. A model was designed and printed using a 3D printer to calibrate the relationship between the fixed sensor and the bronchoscope tip center. For each sensor measurement that includes sensor position and orientation information, its corresponding bronchoscope tip center position was calculated. By minimizing the distance between each bronchoscope tip center position and the bronchial centerlines, the spatial alignment of the electromagnetic tracker system and the CT volume was determined. After obtaining the spatial alignment, an electromagnetic navigation bronchoscopy system was established to real-timely track or locate a bronchoscope inside the bronchial tree during bronchoscopic examinations. Results: The electromagnetic navigation bronchoscopy system was validated on a dynamic bronchial phantom that can simulate respiratory motion with a breath rate range of 0–10 min{sup −1}. The fiducial and target registration errors of this navigation system were evaluated. The average fiducial registration error was reduced from 8.7 to 6.6 mm. The average target registration error, which indicates all tracked or navigated bronchoscope position accuracy, was much reduced from 6.8 to 4.5 mm compared to previous registration methods. Conclusions: An electromagnetically navigated bronchoscopy system was constructed with accurate registration of an electromagnetic tracker and the CT volume on the basis of an improved marker-free registration approach that uses the bronchial centerlines and bronchoscope tip center information. The fiducial and target registration errors of our electromagnetic navigation system were about 6.6 and 4.5 mm in dynamic bronchial phantom validation.

60 APPLIED LIFE SCIENCES↗

Electro-optical measurement of intense electric field on a high energy pulsed power accelerator

We describe a direct electro-optical approach to measuring a strong 118 MV/m narrow pulse width (~ 33 ns) electric field in the magnetically insulated transmission line (MITL) of a pulsed power accelerator. To date, this is the highest direct external electric field measured electro-optically in a pulsed power accelerator, and it is between two to three orders of magnitude higher than values reported in comparable high energy scientific experiments. The MITL electric field is one of the most important operating parameters in an accelerator and is critical to understanding the properties of the radiation output. However, accurately measuring these high fields using conventional pulsed power diagnostics is difficult due to the strength of interfering particles and fields. Our approach uses a free-space laser beam with a dielectric crystal sensor that is highly immune to electromagnetic interference and does not require an external calibration. Here we focus on device theory, operating parameters, laboratory and pulsed power accelerator experiments as well as challenges that were overcome in the measurement environment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Impedance computations and beam-based measurements: A problem of discrepancy

High intensity of particle beams is crucial for high-performance operation of modern electron-positron storage rings, both colliders and light sources. The beam intensity is limited by the interaction of the beam with self-induced electromagnetic fields (wake fields) proportional to the vacuum chamber impedance. For a new accelerator project, the total broadband impedance is computed by element-wise wake-field simulations using computer codes. For a machine in operation, the impedance can be measured experimentally using beam-based techniques. In this article, a comparative analysis of impedance computations and beam-based measurements is presented for 15 electron-positron storage rings. The measured data and the predictions based on the computed impedance budgets show a significant discrepancy. For this article, three possible reasons for the discrepancy are discussed: interference of the wake fields excited by a beam in adjacent components of the vacuum chamber, effect of computation mesh size, and effect of insufficient bandwidth of the computed impedance.

43 PARTICLE ACCELERATORS↗

Performance of the AILES THz-Infrared beamline at SOLEIL for High resolution spectroscopy

The new THz beamline (AILES) located at the third generation Synchrotron Radiation source SOLEIL is now operating for applications in a wide variety of research themes. In particular, this source with its adapted optics allows high resolution spectroscopic measurements of molecules in the entire infrared and THz range. This presentation focuses on the performances concerning flux, spectral range and stability for molecular spectroscopy. Thanks to these performances, the coupling of synchrotron radiation from a highly stable third generation source with high resolution FTIR spectrometer and with a long path cell (150 m or more) can be particularly advantageous. This fact is related to the optics of the beamline permitting the entire source to be used without aperture stop (entrance iris), even for measurements at highest-resolution of approx0.1 mueV (10{sup -3} cm{sup -1}).

43 PARTICLE ACCELERATORS↗

Measurements of single transverse spin asymmetries for hadron productions in {radical}(s) = 200 GeV p+p collisions at STAR

The question of how the spin degrees of freedom in the nucleon are organized has not yet been fully answered. Forward hadron production in transversely polarized p+p collisions provides a unique way of probing the spin structure of the nucleon. Large (10% or more) single transverse spin asymmetries (A{sub N}) were measured at a wide range of collision energy. The STAR collaboration has previously measured {pi}{sup 0} production with the Forward Pion Detector (FPD) at RHIC, and reported that large A{sub N} persists up to {radical}(s) = 200 GeV. A Pb-glass electromagnetic calorimeter detector named the Forward Meson Spectrometer (FMS) has been built and installed at STAR. The FMS covers the pseudo-rapidity region of 2.5<{eta}<4.2 and the full azimuth. The FMS's large acceptance allows us to extend measurements to higher p{sub T}, to heavier mass regions, and to multi particle final states. STAR has collected data with the FMS during Run 8. Results of A{sub N} measurements using the FMS and FPD will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Final Technical Report Project: Low-Energy Photonuclear Studies at HIGS and Lund

This report summarizes a program of low-energy photonuclear studies at MAX-Lab in Lund (Sweden) and at the High Intensity Gamma Source (HIGS) at Duke University. A major emphasis has been on Compton scattering from deuterium in order to determine the electric and magnetic polarizabilities of the neutron. The studies at Lund utilized unpolarized photons at Egamma = 62-115 MeV to measure differential cross sections. The studies at HIGS utilized polarized and unpolarized photon beams (both linear and circular) at Egamma < 90 MeV. Polarization observables will be exploited to improve our understanding of the electric and magnetic polarizabilities, and in particular, double-polarization observables (using polarized targets) will be measured in the future to provide new information about the spin polarizabilities of the nucleon. The MAX-Lab experiments (using unpolarized photons) focused on an approved PAC proposal for Compton scattering on the deuteron aimed at making a precise determination of the electromagnetic polarizabilities of the neutron. At MAX-Lab we had three of the largest NaI detectors in the world, each capable of ~2% energy resolution. We have completed our measurements in two separate tagged photon energy ranges which overlap each other (62-97 MeV and 90-115 MeV) and the results of these experiments have been published. The photon beam at the High Intensity Gamma Source (HIGS) has several distinct advantages that make it unique: (1) ultra-high photon flux, ultimately reaching 100 MHz, (2) 100% linearly polarized photon beam, as well as circular polarization, (3) monoenergetic beam, with ~2% energy resolution, and (4) extremely low-background beam environment. Exploiting the high flux and polarization capabilities of the HIGS photon beam is central in the series of experiments being performed at this facility. Very little data exist on Compton scattering using polarized photons. We will exploit clear sensitivities in the polarization observables to the electric and magnetic polarizabilities of the nucleon, and we will ultimately extend these studies to the investigation of the spin polarizabilities. To accomplish these objectives, a liquid hydrogen/deuterium/helium cryotarget has been constructed at HIGS, and an array of NaI detectors has been commissioned for Compton studies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Large Eddy Simulations of Electromagnetic Braking Effects on Argon Bubble Transport and Capture in a Steel Continuous Casting Mold

In continuous casting of steel, argon gas is often injected to prevent clogging of the nozzle, but the bubbles affect the flow pattern, and may become entrapped to form defects in the final product. Further, an electromagnetic field is frequently applied to induce a braking effect on the flow field and modify the inclusion transport. In this study, a previously validated GPU-based in-house code CUFLOW is used to investigate the effect of electromagnetic braking on turbulent flow, bubble transport, and capture. Well-resolved large eddy simulations are combined with two-way coupled Lagrangian computations of the bubbles. The drag coefficient on the bubbles is modified to account for the effects of the magnetic field. The distribution of the argon bubbles, capture, and escape rates, are presented and compared with and without the magnetic field. The bubble capture patterns are also compared with results of a previous RANS model as well as with plant measurements.

36 MATERIALS SCIENCE↗

Measurement of the dispersion of radiation from a steady cosmological source

The 'missing baryons' of the near universe are believed to be principally in a partially ionized state. Although passing electromagnetic waves are dispersed by the plasma, the effect has hitherto not been utilized as a means of detection because it is generally believed that a successful observation requires the background source to be highly variable, i.e., the class of sources that could potentially deliver a verdict is limited. We argue in two stages that this condition is not necessary. First, by modeling the fluctuations on macroscopic scales as interference between wave packets, we show that, in accordance with the ideas advanced by Einstein in 1917, both the behavior of photons as bosons (i.e., the intensity variance has contributions from Poisson and phase noise) and the van-Cittert-Zernike theorem are a consequence of wave-particle duality. Nevertheless, we then point out that, in general, the variance on some macroscopic timescale τ consists of (1) a main contributing term ∝1/τ, plus (2) a small negative term ∝1/τ{sup 2} due to the finite size of the wave packets. If the radiation passes through a dispersive medium, this size will be enlarged well beyond its vacuum minimum value of Δt ≈ 1/Δν, leading to a more negative (2) term (while (1) remains unchanged), and hence a suppression of the variance wrt the vacuum scenario. The phenomenon, which is typically at a few parts in 10{sup 5} level, enables one to measure cosmological dispersion in principle. Signal-to-noise estimates, along with systematic issues and how to overcome them, will be presented.

79 ASTRONOMY AND ASTROPHYSICS↗

Quadrupole collectivity in the neutron-rich sulfur isotopes 38,40,42,44 S

Electromagnetic transition strengths in the even-even neutron-rich sulfur isotopes 38,40,42,44 S were measured using intermediate-energy Coulomb excitation at the National Superconducting Cyclotron Laboratory. By utilizing the sensitivity of the experimental technique to E2 excitations from the ground state, the evolution of the pattern of B(E2) strengths to several low-lying 2 + states was investigated at Z = 16 from near stability to the N = 28 island of inversion. The experimental results allowed a detailed comparison with predictions from shell-model calculations using the SDPF-MU Hamiltonian, which was designed to describe collectivity in this region of the nuclear chart. While the shell-model calculations succeeded in modeling transition strengths at N = 22, 24, 26, the experimental B(E2; $0$ $^{+}_{1}$ → $2$ $^{+}_{1}$) at N = 28 was smaller than the predicted value by about a factor of 2, similar to previous observations for chlorine and argon isotopes around N = 28. The dependence of this overprediction by theory on the choice of effective charges was explored.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of the Support and Drive System of the PETRA III APPLE Undulator

Helmholtzzentrum Berlin has built an APPLE II undulator for the storage ring PETRA III. The device has a total length of 5m and a minimum gap of 11mm. The high magnetic forces in particular in the inclined mode have been analyzed by means of finite element methods (FEM). Specific mechanic components such as flexible joints have been optimized to cope with the gap- and shift-dependent 3D-forces and a sophisticated control and drive system has been implemented. After completion of the device, detailed laser interferometer measurements for all operation modes have been performed. The data are compared to the FEM simulations.

43 PARTICLE ACCELERATORS↗

From a discrete to a continuous model for interpulse interference with a frequency-comb laser

We have investigated correlation patterns generated by a frequency-comb laser in a dispersive unbalanced Michelson interferometer and apply the developed formalism to the case of distance metrology. Due to group velocity dispersion, the position of the brightest fringe of the correlation pattern, which is used for distance determination, cannot be derived by simply using the definition of group refractive index of the dispersive medium. It is shown that the discrete spectrum of the optical frequency comb gives rise to correlation functions which can be represented by a series, namely a discrete correlation series. We have developed a general formalism, valid for any pulse train, extending the discrete model to a continuous model of cross-correlation functions using the Poisson summation. Our model is relevant for any offset and repetition frequency of the frequency comb. From the continuous cross-correlation model we show that, even for a homogeneous dispersive medium the position of the brightest fringe varies nonlinearly for small delay distances and stabilizes for longer ones. We have compared the theoretical results to measurements of pulse propagation in air for path-lengths up to 200 m.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The next-generation magnetic recoil spectrometer (MRSnext) on OMEGA and NIF for diagnosing ion temperature, yield, areal density, and alpha heating

The next-generation magnetic recoil spectrometer (MRSnext) is being designed to replace the current MRS at the National Ignition Facility and OMEGA for measurements of the neutron spectrum from an inertial confinement fusion implosion. The MRSnext will provide a far-superior performance and faster data turnaround than the current MRS systems, i.e., a 2× and 6× improvement in energy resolution at the NIF and OMEGA, respectively, and 20× improvement in data turnaround time. The substantially improved performance of the MRSnext is enabled by using electromagnets that provide a short focal plane (12–16 cm) and unprecedented flexibility for a wide range of applications. In addition to being able to measure neutron yield, apparent ion temperature, areal density, and plasma-flow velocity over a wide range of yields, the NIF MRSnext will be able to directly, uniquely assess the alpha heating of the fuel ions through measurements of the alpha knock-on tail in the neutron spectrum. The goal is to implement a radiation-hard electronic detection system capable of providing rapid data acquisition and analysis. The development of the MRSnext will also set the foundation for the more advanced, time-resolving MRSt and serve as a testbed for its implementation on the NIF.

47 OTHER INSTRUMENTATION↗

A detailed map of Higgs boson interactions by the ATLAS experiment ten years after the discovery

The standard model of particle physics describes the known fundamental particles and forces that make up our Universe, with the exception of gravity. One of the central features of the standard model is a field that permeates all of space and interacts with fundamental particles. The quantum excitation of this field, known as the Higgs field, manifests itself as the Higgs boson, the only fundamental particle with no spin. In 2012, a particle with properties consistent with the Higgs boson of the standard model was observed by the ATLAS and CMS experiments at the Large Hadron Collider at CERN. Since then, more than 30 times as many Higgs bosons have been recorded by the ATLAS experiment, enabling much more precise measurements and new tests of the theory. Here, on the basis of this larger dataset, we combine an unprecedented number of production and decay processes of the Higgs boson to scrutinize its interactions with elementary particles. Interactions with gluons, photons, and W and Z bosons—the carriers of the strong, electromagnetic and weak forces—are studied in detail. Interactions with three third-generation matter particles (bottom (b) and top (t) quarks, and tau leptons (τ)) are well measured and indications of interactions with a second-generation particle (muons, μ) are emerging. These tests reveal that the Higgs boson discovered ten years ago is remarkably consistent with the predictions of the theory and provide stringent constraints on many models of new phenomena beyond the standard model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Few-body physics with CLAS

The study of few-body, nuclear systems with electromagnetic probes is an essential piece of the scientific program at Jefferson Lab. Reactions using real photons and electrons (up to energies of 6 GeV) are measured using the CEBAF large acceptance spectrometer (CLAS) detector in Hall B, a nearly 4π magnetic spectrometer. We focus here on three areas. (1) Short-range correlations (SRCs) probe the high-momentum components of the nuclear wave function. Recent CLAS experiments map out their isospin character and reveal the importance of the tensor part of the nuclear force. (2) Three-body forces are an essential feature of nuclei. We will show results using real photons and 3He and 4He targets that remain largely unexplained. (3) Evidence for the transition to a quark-gluon description of nuclei has been observed with photon beams in CLAS on deuterium and 3-He targets. Alternative explanations reveal the geography of the transition is complex.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗