EMTP based stability analysis of space station electric power system in a test bed environment

The Space Station Freedom Electric Power System (EPS) will convert solar energy into electric energy and distribute the same using an 'all dc', Power Management and Distribution (PMAD) System. Power conditioning devices (dc to dc converters) are needed to interconnect parts of this system operating at different nominal voltage levels. Operation of such devices could generate under damped oscillations (instability) under certain conditions. Criteria for instability are examined and verified for a single device. Suggested extension of the criteria to a system operation is examined by using the EMTP model of the PMAD DC test bed. Wherever possible, data from the test bed is compared with the modeling results.

Dravid, Narayan V.↗

EMTP based stability analysis of Space Station Electric Power System in a test bed environment

The Space Station Freedom Electric Power System (EPS) will convert solar energy into electric energy and distribute the same using an 'all dc', Power Management and Distribution (PMAD) System. Power conditioning devices (dc to dc converters) are needed to interconnect parts of this system operating at different nominal voltage levels. Operation of such devices could generate under damped oscillations (instability) under certain conditions. Criteria for instability are examined and verified for a single device. Suggested extension of the criteria to a system operation is examined by using the EMTP model of the PMAD dc test bed. Wherever possible, data from the test bed is compared with the modeling results.

Dravid, Narayan V.↗

Estimating Transmitted-Signal Phase Variations for Uplink Array Antennas

A method of estimating phase drifts of microwave signals distributed to, and transmitted by, antennas in an array involves the use of the signals themselves as phase references. The method was conceived as part of the solution of the problem of maintaining precise phase calibration required for proper operation of an array of Deep Space Network (DSN) antennas on Earth used for communicating with distant spacecraft at frequencies between 7 and 8 GHz. The method could also be applied to purely terrestrial phased-array radar and other radio antenna array systems. In the DSN application, the electrical lengths (effective signal-propagation path lengths) of the various branches of the system for distributing the transmitted signals to the antennas are not precisely known, and they vary with time. The variations are attributable mostly to thermal expansion and contraction of fiber-optic and electrical signal cables and to a variety of causes associated with aging of signal-handling components. The variations are large enough to introduce large phase drifts at the signal frequency. It is necessary to measure and correct for these phase drifts in order to maintain phase calibration of the antennas. A prior method of measuring phase drifts involves the use of reference-frequency signals separate from the transmitted signals. A major impediment to accurate measurement of phase drifts over time by the prior method is the fact that although DSN reference-frequency sources separate from the transmitting signal sources are stable and accurate enough for most DSN purposes, they are not stable enough for use in maintaining phase calibrations, as required, to within a few degrees over times as long as days or possibly even weeks. By eliminating reliance on the reference-frequency subsystem, the present method overcomes this impediment. In a DSN array to which the present method applies (see figure), the microwave signals to be transmitted are generated by exciters in a signal-processing center, then distributed to the antennas via optical fibers. At each antenna, the signals are used to drive a microwave power-amplifier train, the output of which is coupled to the antenna for transmission. A small fraction of the power-amplifier-train output is sent back to the signal-processing center along another optical fiber that is part of the same fiber-optic cable used to distribute the transmitted signal to the antenna. In the signal-processing center, the signal thus returned from each antenna is detected and its phase is compared with the phase of the signal sampled directly from the corresponding exciter. It is known, from other measurements, that the signal-propagation path length from the power-amplifier-train output port to the phase center of each antenna is sufficiently stable and, hence, that sampling the signal at the power-amplifier-train output port suffices for the purpose of characterizing the phase drift of the transmitted signal at the phase center of the antenna

Paal, Leslie↗

Evolutionary Game Dynamics between Distributed Energy Resources and Microgrid Operator: Balancing Act for Power Factor Improvement

This article investigates the intricate dynamics between Distributed Energy Resources (DERs) and the Microgrid Operator (MGO) within a microgrid interconnected with the main grid. Employing an evolutionary game framework, the study scrutinizes the strategic evolution of DERs’ decision-making processes in their interactions with the MGO. Modeled as an evolutionary game, these interactions encapsulate the strategies adopted by DERs, resulting in stable equilibrium strategies over time. Motivated by direct benefits linked to increased active power production, DERs strive to sell all available power, while the MGO focuses on optimizing the microgrid’s overall performance. The study assesses the microgrid’s performance in terms of its power factor, emphasizing the strategic balance DERs must achieve in their active power generation to avoid penalization. This penalization results in decreased individual utility for DERs due to the overall power factor decrease resulting from their prioritization of active power generation. Additionally, the diminished overall power factor implies a decrease in MGO utility. The individual utility of each DER is further influenced by the strategies adopted by other DERs, impacting the penalization factor. Leveraging a modified IEEE 13-node distribution microgrid consisting of three DERs, the study presents case studies encompassing both cooperative and non-cooperative evolutionary game scenarios. These case studies illuminate the intricacies of interactions and the resulting equilibrium outcomes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Langmuir Probe Measurements of Inductively Coupled CHF3/Ar and Ar/CHF3/O2 Plasmas

Plasma parameters, such as, electron number density (ne), electron temperature (Te), y electron energy distribution function (EEDF), mean electron energy (Ee), ion number density (ni), and plasma potential (Vp), have been measured by using Langmuir probe in low-pressure (10-50 mTorr) inductively coupled CHF3/Ar and CHF3/Ar/O2 plasmas generated in the GEC cell. The measurements were made at the center of the plasma, keeping the lower electrode grounded, for various CHF3/Ar and Ar/CHF3/O2 mixtures operating at 10-50 mTorr pressures and two input RF power levels, 200 and 300 W. EEDF data show a strong Druyvesteyn distribution with relatively lower number of low energy electrons as compared to a Maxwell distribution and a large electron population with energies higher than the plasma potential. The results further show that at low CHF3 concentrations (less than 50%) the electron number density remains nearly constant with increase in pressure. At higher CHF3 concentrations, however, it decreases with increase in pressure. Plasma potential and electron temperature increase with decrease in pressure and with increase in CHF3 concentration. An analysis of the above observations and mechanisms will be presented.

Sharma, S. P.↗

Planning Roadmap for DER Integration in India: Industry Best Practices and Resource Guide

Ensuring safe, reliable, cost-effective DER integration at scale requires holistic planning, broad stakeholder engagement, and should address key development areas such as standards adoption, equipment testing and certification, interoperability and cybersecurity, interconnection procedures, and advanced forecasting and DER management. Each of these areas currently represent significant challenges for utilities, regulators, OEMs, developers, and even consumers worldwide. India has already seen significant growth of DERs and has announced targets for substantial growth yet to come, with the potential for DERs to make up a non-negligible portion of the country's overall generation capacity. As such, it is of critical importance that Indian stakeholders consider the potential impacts of wide-spread adoption of DERs and take preemptive action related to the five development areas listed here, among others. India should consider strategies including the adoption of key DER standards related to interconnection, testing, and cybersecurity; enabling effective and secure communication channels for DER interoperability; testing and certifying DER equipment in accredited testing laboratories; building robust, streamlined interconnection procedures; and revamping legacy system planning structures to incorporate DERs in a holistic planning framework.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hot Electron Scaling and Energy Coupling In Nonlinear Laser Plasma Interactions

Energy conversion from high power lasers to energetic hot electrons is a fundamental phenomenon in laser-plasma interactions. At laser intensities above a few times 10 14 W/cm 2 , nonlinear laser-plasma interactions lead to the generation of hot electrons with a broad energy distribution at typical temperatures of 10’s – 100’s kilo-electron-volt (keV). The fraction of laser energy transferred to hot electrons, their energy distribution and energy coupling efficiency to the targets are strongly affected by the laser intensity, wavelength and the plasma condition. Most investigations to date that are related to the fusion of high-energy-density laboratory plasmas (HEDLP) are carried out with relatively moderate laser intensity and lower laser wavelength to minimize hot electron generation, as electron preheating can degrade the fuel assembly. An alternative fusion scheme known as shock ignition (SI) has been proposed, requiring a high intensity spike pulse at the end of a fuel assembly phase to generate a strong shock to ignite the fuel. An initial shock pressure of 0.3 Gbar is required for ignition-scale targets using the SI scheme, requiring a relatively high on-target laser intensity of 5-10X10 15 W/cm 2 for the spike pulse. At such intensities, copious hot electrons can be produced by laser-plasma-instabilities (LPI), e.g., Stimulated Raman Scattering (SRS) and Two-Plasmon Decay (TPD). While very energetic electrons (>200 keV) could preheat the fuel, electrons with moderate energies may actually be beneficial for the SI scheme. Electrons in the 50-100 keV range can be stopped in the compressed high-density outer ablator layer leading to an increase in the ignitor shock strength and therefore enhancing overall efficiency in the SI scheme. Considering this importance of total energy and temperature of hot electrons, it is necessary to understand the LPI in the SI high intensity regime. Characterizing the hot electron source and energy coupling is key to investigating the viability of the SI concept. The overall goal of the HEDLP award was to perform a detailed study of the scaling of hot electron generation and energy coupling on high power laser systems, with intensity, wavelength, and target ablator material relevant to the nonlinear laser-plasma interaction at SI relevant conditions. This was a collaborative project between the Center for Energy Research at the University of California, San Diego (UCSD) and General Atomics. The experiment was performed at the Omega Laser Facility at the Laboratory for Laser Energetics (LLE) in the University of Rochester. Specific objectives of the work were to: understand the basic physics of laser-plasma interactions and instabilities at high laser intensities (up to 10 17 W/cm 2 ) and the effects of low-Z ablator materials and laser wavelengths (IR pulse at 1.054 µm versus UV pulse at 0.351 µm) and intensity scaling, fully characterize the resultant hot electron energy distribution, validate hot electron energy deposition via collisional and kinetic processes in the target and the induced shocks in support of electron-assisted SI concept.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Specifying angular reference for robust three-phase state estimation

While the phase angle of any of the bus voltages can be chosen as the angular reference in the state estimation formulation of positive sequence networks, the same approach does not readily extend to three-phase network state estimation problem. It is commonly assumed that there is at least one bus where the bus voltages are perfectly balanced with phase angles displaced ±120° and these balanced three phase voltages are used as the three-phase reference in solving the three-phase state estimation problem. This assumption may be quite realistic in transmission networks, and for distribution networks with a strong transmission system connection. However, it might not be realistic to assume existence of a perfectly balanced reference bus in today’s distribution systems with ever increasing penetration of renewable sources or for isolated operation of microgrids. In this paper, a novel state estimation formulation will be presented which facilitates correct solution irrespective of the existence of buses with perfectly balanced voltages. The new formulation is general, and lends itself to bad data processing. It yields accurate results in any three-phase power system irrespective of its operating conditions (balanced or highly unbalanced), configuration (isolated microgrid, connected to transmission system, etc.) and whether or not it contains any synchronous generators. The performance of the method is validated using the IEEE 123 bus three-phase system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reliable Protection for an Inverter-Based Resources Dominant Grid: Technology Development and Field Demonstration

The project aimed to address the challenges posed by the rapid growth of inverter-based resources (IBR) such as solar, wind, and battery storage, which have fundamentally changed fault behavior, system strength, and protection performance in bulk power systems. Traditional protection schemes, designed for synchronous generator-dominated grids, are inadequate under high IBR penetration. Overall, the project materially advances protection modeling and simulation capabilities needed to maintain reliable grid protection under high IBR penetration. The results build utility confidence in operating power systems safely and reliably across a wide range of generation mixes, supporting grid modernization goals.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data-Driven Scalable Emulation of Hydropower Using Real-Time Hardware-in-the-Loop

This presentation covers Motivation: (1) With the increased grid integration of inverter-based resources, hydropower plays a crucial role in maintaining the bulk power system reliability and resilience; and (2) A more dynamic response and new control designs are required to meet the grid requirements. To evaluate any modification, control-prototyping, performance validation and de-risking grid integration of hydropower, a high-fidelity environment is required. Also covers Objectives: (1) To develop data-driven emulation of hydropower using hardware-in-the-loop for different size, types of hydro plants; and (2) To characterize hardware and obtain accurate dynamic response for shaft speed, torque, and power. Provide a mechanical power interface with emulated dynamics of a hydro-turbine shaft that can be coupled to electrical generators for mechanical and electrical PHIL.

electrical↗

Open-Source High-Fidelity Aggregate Composite Load Models of Emerging Load Behaviors for Large-Sale Analysis

The goal of this project is to accurately model the dynamic loads for power system planning and operation and to address the challenges inherent in such modeling. Existing load models are inadequate to handle the increasing proliferation of residential air conditioner loads and distributed energy resources, the emerging trends of price-responsive demand, and the growing importance of protective devices in equipment and buildings. A need has emerged to develop a fundamentally new class of load models and next-generation data tools. This work proposes to develop a set of regional–level, scalable open source load models and tools, including large-scale aggregate load protection, concept of price responsive demand, advanced load composition data, next-generation load model data tools, and advanced composite load model calibration and validation frameworks to address new challenges in the representation of next-generation load models.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Modular Power System Fully Populated Electronics Enclosure Thermal Testing

A thermal test of an enclosure housing the AMPS electronics cards was performed. The enclosure was fully populated with 17 nonfunctioning AMPS electronics cards. Heaters were applied to the cards to simulate their operation. A cold plate was installed on the top of the case. The case was then insulated to simulate its installation within an electronics rack with the face and rear of the enclosure left open. The cold plate was connected to a chiller which provided cooling water at a fixed input temperature to the cold plate. Flow rates from the chiller of 0.0 L/min, 1.4 L/min and 1.8 L/min were tested. The test was operated at each flow rate over a range of heater power levels until the steady state temperature of the electronics cards was reached. Heater power levels from 2.5 W/card to 45 W/card were tested. The data collected was used to determine the steady state operating temperature of the cards, the temperature distribution between the cards, the time to reach steady-state temperature, the change in steady state temperature with change in heater power, the temperature distribution between the cards at the steady state condition and the heat lost to the surrounds by the enclosure. One of the main goals of the testing was to determine how much waste heat the cards could generate and still maintain a touch temperature at or below 40°C. Based on this requirement, for the 3 cooling rates tested, the maximum card waste heat that could be generated by each individual card was 3.9 W, 16.3 W and 17.6 W respectively. An analysis was also set up to provide an analytical model to estimate the card temperature under different cold plate flow rates and card heater power levels. The results off the analysis was compared to that of the experiment of the range of flow rates and power levels tested.

Anthony Colozza↗

Early retirement of power plants in climate mitigation scenarios

International efforts to avoid dangerous climate change aim for large and rapid reductions of fossil fuel CO 2 emissions worldwide, including nearly complete decarbonization of the electric power sector. However, achieving such rapid reductions may depend on early retirement of coal- and natural gas-fired power plants. Here, we analyze future fossil fuel electricity demand in 171 energy-emissions scenarios from Integrated Assessment Models (IAMs), evaluating the implicit retirements and/or reduced operation of generating infrastructure. Although IAMs calculate retirements endogenously, the structure and methods of each model differ; we use a standard approach to infer retirements in outputs from all six major IAMs and—unlike the IAMs themselves—we begin with the age distribution and region-specific operating capacities of the existing power fleet. We find that coal-fired power plants in scenarios consistent with international climate targets (i.e. keeping global warming well-below 2 °C or 1.5 °C) retire one to three decades earlier than historically has been the case. If plants are built to meet projected fossil electricity demand and instead allowed to operate at the level and over the lifetimes they have historically, the roughly 200 Gt CO 2 of additional emissions this century would be incompatible with keeping global warming well-below 2 °C. Thus, ambitious climate mitigation scenarios entail drastic, and perhaps un-appreciated, changes in the operating and/or retirement schedules of power infrastructure.

20 FOSSIL-FUELED POWER PLANTS↗

DEEP Solar: Data DrivEn Modeling and Analytics for Enhanced System Layer ImPlementation

Realizing the SETO 2030 mission of reducing solar energy costs to 3-5 c/kWh will require innovative enabling research on effective, cost-efficient integration of local PV within distribution systems. However, the intermittent and variable nature of PVs compels operators to impose conservative hosting capacity constraints. Given the extremely high variability of (intermittent and unpredictable) solar energy generation, relaxing the capacity constraints (which are currently around 15%) and achieving 100% or greater integration of renewables will require a fundamental transformation of the power grid via the utilization of exponentially larger amounts of AMI enabled fine-grained data. To address the challenges in increasing the penetration of renewable energy based DERs, this project envisions an Enhanced System Layer (ESL) at the distribution network level that is reliable, cost-effective and scalable to millions of Distributed Energy Resources (DERs)/devices. This includes developing: 1) Transformative and highly scalable machine learning based predictive analytics tools that plug into distribution system planning and provide real-time situational awareness at the distribution level for short and long-term operational planning. The tools will be built using novel data-driven energy models of millions of active nodes with AMI, 2) Adaptive stochastic analysis and optimization algorithms for real-time grid operations, 3) Dynamic Scenario Analysis using parallel Cloudenabled implementations with < 1 minute computational cycle times.

14 SOLAR ENERGY↗

Kilometric radiation power flux dependence on area of discrete aurora

Kilometer wavelength radiation, measured from distant positions over the North Pole and over the Earth's equator, was compared to the area of discrete aurora imaged by several low-altitude spacecraft. Through correlative studies of auroral kilometric radiation (AKR) with about two thousand auroral images, a stereoscopic view of the average auroral acceleration region was obtained. A major result is that the total AKR power increases as the area of the discrete auroral oval increases. The implications are that the regions of parallel potentials or the auroral plasma cavities, in which AKR is generated, must possess the following attributes: (1) they are shallow in altitude and their radial position depends on wavelength, (2) they thread flux tubes of small cross section, (3) the generation mechanism in them reaches a saturation limit rapidly, and (4) their distribution over the discrete auroral oval is nearly uniform. The above statistical results are true for large samples collected over a long period of time (about six months). In the short term, AKR frequently exhibits temporal variations with scales as short as three minutes (the resolution of the averaged data used). These fluctuations are explainable by rapid quenchings as well as fast starts of the electron cyclotron maser mechanism. There were times when AKR was present at substantial power levels while optical emissions were below instrument thresholds. A recent theoretical result may account for this set of observations by predicting that suprathermal electrons, of energies as low as several hundred eV, can generate second harmonic AKR. The indirect observations of second harmonic AKR require that these electrons have mirror points high above the atmosphere so as to minimize auroral light emissions. The results provide evidence supporting the electron cyclotron maser mechanism.

Saflekos, N. A.↗

Competitiveness Improvement Project Informational Workshop

The National Renewable Energy Laboratory (NREL) is hosted an in-person workshop and webinar for the distributed wind Competitiveness Improvement Project (CIP) on Tuesday, December 17, 2019, at NREL's Flatirons Campus. The CIP is a periodic solicitation issued by NREL on behalf of the U.S. Department of Energy's Wind Energy Technologies Office. Through a competitive process, component suppliers and manufacturers of small- to medium-sized wind turbine technology are awarded cost-shared subcontracts to optimize their designs, develop advanced manufacturing processes, and perform turbine testing. The CIP aims to make wind energy cost competitive with other distributed generation technologies and increase the number of wind turbine designs certified to national performance and safety standards.

17 WIND ENERGY↗

Design for the Structure and the Mechanics of Moballs

The moball is envisioned to be a round, self-powered, and wind-driven multifunctioning sensor used in the Gone with the Wind ON-Mars (GOWON) [http://www.lpi.usra.edu/meetings/ marsconcepts2012/pdf/4238.pdf]: A Wind-Driven Networked System of Mobile sensors on Mars. The moballs would have sensing, processing, and communication capabilities. The moballs would perform in situ detection of key environmental elements such as vaporized water, trace gases, wind, dust, clouds, light and UV exposure, temperature, as well as minerals of interest, possible biosignatures, surface magnetic and electric fields, etc. The embedded various low-power micro instruments could include a Multispectral Microscopic Imager (to detect various minerals), a compact curved focal plane array camera (UV/Vis/NIR) with a large field of view, a compact UV/Visible spectrometer, a micro-weather station, etc. The moballs could communicate with each other and an orbiter. Their wind- or gravity-driven rolling movement could be used to harvest and store electric energy. They could also generate and store energy using the sunlight, when available, and the diurnal temperature variations on Mars. The moballs would be self-aware of their (and their neighbors ) positions, energy storage, and memory availability; they would have processing power and could intelligently cooperate with neighboring moballs by distributing tasks, sharing data, and fusing information. The major advantages of using the wind-driven and spherical moball network over rovers or other fixed sensor webs to explore Mars would be: (1) moballs could explore a much larger expanse of Mars in a much faster fashion, (2) they could explore the difficult terrains such as steep slopes and sand dunes, and (3) they would be self-energy- generating and could work together and move around autonomously. The challenge in designing the structure and the mechanics of the moball would be that it should be sturdy enough to withstand the impact of its initial fall, as well as other impacts from obstacles in its way. A mechanism would be needed that could enable hundreds of moballs to be carried while they would be deflated and compact, then would inflate them just after deploying them to their drop site. Furthermore, the moballs should also be light enough to allow them to move easily over obstacles by force of the wind. They also should have some kind of maneuvering mechanism in place to help them avoid very hazardous sharp objects or events, and to enable them to get closer to the objects of interest. The structure of the moballs was designed so that they would have different layers. The outer layer should comprise a sturdy, yet light, polymer that could withstand both the impact of the initial drop, as well as the impact of the different obstacles it would encounter while traversing the surface of Mars. This polymer should not deteriorate with the 100 K daily temperature swings on Mars. The inner layer should consist of a very light gas such as nitrogen or helium. In terms of maneuvering, six very light weights placed at strategic locations would give moballs the ability to turn, or even hop, over hazardous (e.g., sharp) obstacles, or even initiate a movement (before getting more help from the wind to be carried around) when stuck. Maneuvering would be necessary in order to get closer to objects of interest. If the weights would be allowed to move freely, they could also be used to generate energy.

Davoodi, Faranak↗

Optimal Energy Dispatch of Distributed PVs for the Next Generation of Distribution Management Systems

Advanced Distribution Management Systems (ADMS) are being widely adopted by electric utilities for managing and optimizing the operations of their distribution systems. Distributed photovoltaic (DPV) systems with smart inverters can be controlled to adjust active power and reactive power outputs, and they are envisioned to become a part of (centrally or distributed) controllable assets managed by the ADMS for optimizing grid operations. This paper proposes an optimal energy dispatch strategy controlling DPV systems for regulating distribution voltages and achieving conservation voltage reduction. A convex optimization model is proposed with the use of linearized power flow, and the gradient projection algorithm is used to solve the optimal active power and reactive power outputs of smart inverters. The proposed optimal energy dispatch is implemented using an open-source ADMS platform, and simulation results have demonstrated the effectiveness of the proposed approach on improving distribution grid operations.

42 ENGINEERING↗