Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Data analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

πScope: Python based scientific workbench with MDSplus data visualization tool

In this work, a newly developed python based scientific data analysis and visualization tool, πScope (http://piscope.psfc.mit.edu), is reported. The primary motivation is 1) to provide an updated tool to browse the MDSplus data beyond existing dwscope/jScope and 2) to realize a universal foundation to construct interface tools to perform computer modeling from experimental data. To visualize MDSplus data, πScope has many features including overplotting different signals and discharges, generating various plot types (line, contour, image, etc.), performing in-panel data analysis using python scripts, and producing publication quality graphics. The logic to generate multi-panel plots is designed to be backward compatible with dwscope, enabling smooth migration for users. πScope uses multi-threading in data loading, and is easy to modify and expand due to its object-oriented design. Furthermore, A user can access the data structure both from a GUI and a script, enabling relatively complex data analysis workflow built quickly on πScope.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Echo

This document is a white paper marketing proposal for Echo™ is a data analysis platform designed for efficient, robust, and scalable creation and execution of complex workflows. Echo’s analysis management system refers to the ability to track, understand, and reproduce workflows used for arriving at results and decisions. Echo improves on traditional scripted data analysis in MATLAB, Python, R, and other languages to allow analysts to make better use of their time. Additionally, the Echo platform provides a powerful data management and curation solution allowing analysts to quickly find, access, and consume datasets. After two years of development and a first release in early 2016, Echo is now available for use with many data types in a wide range of application domains. Echo provides tools that allow users to focus on data analysis and decisions with confidence that results are reported accurately.

97 MATHEMATICS AND COMPUTING↗

A deep learning-guided automated workflow in LipidOz for detailed characterization of fungal fatty acid unsaturation by ozonolysis

Understanding fungal lipid biology and metabolism is critical for antifungal target discovery as lipids play central roles in cellular processes. Nuances in lipid structural differences can significantly impact their functions, making it necessary to characterize lipids in detail to enable and understanding of their roles in these complex systems. In particular, lipid double bond (DB) locations are an important component of lipid structure that can only be determined using a few specialized analytical techniques. Ozone-induced dissociation mass spectrometry (OzID-MS) is one such technique that uses ozone to break lipid DBs, producing pairs of characteristic fragments that allow the determination of DB positions. In this work we apply OzID-MS and LipidOz software to analyze the complex lipids of Saccharomyces cerevisiae yeast strains transfected with different fatty acid desaturases from Histoplasma capsulatum to determine the specific unsaturated lipids produce. The automated data analysis in LipidOz made the determination of DB positions from this large dataset more practical, but manual verification for all targets was still time-consuming. The DL model reduces manual involvement in data analysis, but since it was trained using mammalian lipid extracts, the prediction accuracy on yeast-derived data was reduced. We addressed both shortcomings by retraining the DL model to act as a pre-filter to prioritize targets for automated analysis, providing confident manually verified results but requiring less computational time and manual effort. Our workflow resulted in the determination of novel DB positions and enzymatic specificity.

mass spectrometry, deep learning, Lipidomics, doub↗

AMS / BARC Joint Survey Addendum Technical Report

This report details the data analysis results from data collected during the September-October 2019 joint survey series between the Department of Energy (DOE) National Nuclear Security Administration (NNSA) Aerial Measuring System (AMS) asset, and the Government of India’s Department of Atomic Energy (DAE) Bhabha Atomic Research Centre (BARC). This joint survey series took place at the Nevada National Security Site (NNSS), areas of public land in Southern Nevada, and at the DOE Office of Legacy Management (LM) Large Area Calibration Pads (LACP) at the Grand Junction Regional Airport in Grand Junction, CO. The data detailed in this report were gathered at the LACP. More details regarding the setup of these surveys and personnel involvement can be found in the AMS / BARC Joint Survey Summary Report. The data from the LACP collected by AMS are consistent with past data collection campaigns at the LACP. The AMS Bell 412 (B412) helicopter, equipped with both the standard AMS thallium-doped sodium iodide (NaI(Tl)) 2"x4"x16" 12-detector system and a subset of the BARC Aerial Gamma Spectroscopy System (AGSS) consisting of two independent 3"x3"cylindrical NaI(Tl) detectors, measured each of the five calibration pads for a minimum of 10 minutes. After the helicopter measurements, a pressurized ion chamber (PIC) was used to directly measure radiation exposure rates on each of the pads for a period 5 minutes. The geophysical calibration procedure published by the International Atomic Energy Agency (IAEA) (Erdi-Krausz et al. 2003) was used to determine the spectral stripping sensitivity matrix for naturally occurring radiological material (NORM). The sensitivity matrix is consistent with the AMS long term average. Additionally, the PIC data was used to calibrate the AMS system for exposure rate. The results of the exposure rate analysis are also consistent with AMS long-term averages.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

GROUND-BASED NEAR-INFRARED EMISSION SPECTROSCOPY OF HD 189733B

We investigate the K- and L-band dayside emission of the hot-Jupiter HD 189733b with three nights of secondary eclipse data obtained with the SpeX instrument on the NASA Infrared Telescope Facility. The observations for each of these three nights use equivalent instrument settings and the data from one of the nights have previously been reported by Swain et al. We describe an improved data analysis method that, in conjunction with the multi-night data set, allows increased spectral resolution (R {approx} 175) leading to high-confidence identification of spectral features. We confirm the previously reported strong emission at {approx}3.3 {mu}m and, by assuming a 5% vibrational temperature excess for methane, we show that non-LTE emission from the methane {nu}{sub 3} branch is a physically plausible source of this emission. We consider two possible energy sources that could power non-LTE emission and additional modeling is needed to obtain a detailed understanding of the physics of the emission mechanism. The validity of the data analysis method and the presence of strong 3.3 {mu}m emission are independently confirmed by simultaneous, long-slit, L-band spectroscopy of HD 189733b and a comparison star.

79 ASTRONOMY AND ASTROPHYSICS↗

BEAM EMITTANCE MEASUREMENT TOOL FOR CEBAF OPERATIONS

A new software tool was created at Jefferson Lab to measure the emittance of the CEBAF electron beams. The tool consists of device control and data analysis applications. The device control application handles the work of wire scanners and writes their measurement results as well as the information about accelerator settings during these measurements into wire scanner data files. The data analysis application reads these files and calculates the beam emittance on the basis of a wire scanner data processing model. Both applications are computer platform independent but are mostly used on LINUX PCs recently installed in the accelerator control room. The new tool significantly simplifies beam emittance measurement procedures for accelerator operations and contributes to a very high availability of the CEBAF machine for the nuclear physics program at Jefferson Lab.

43 PARTICLE ACCELERATORS↗

The DOE Geothermal Data Repository and the Future of Geothermal Data

We are, right now, in the midst of the Data Revolution. Just as the Industrial Revolution of the early 1800's marked a major turning point in history with changes to manufacturing that influenced almost every aspect of daily life, the proliferation of big data and the evolution of our collective ability to put it to work for us is having a profound impact on our lives today. The U.S. Department of Energy's (DOE) Geothermal Data Repository (GDR) is leveraging new resources, such as the National Renewable Energy Laboratory's (NREL) new secure cloud environment, and cutting edge approaches to data analysis, to prepare for the challenges that data from energy and geosciences research presents. This paper will explore some of those challenges, highlight some of the benefits of data analysis, and explain the steps DOE and NREL are taking to ensure the GDR is ready for the future of geothermal data.

15 GEOTHERMAL ENERGY↗

An Optimized Informatics Pipeline for Mass Spectrometry-Based Peptidomics

Comprehensive MS analysis of peptidome, the intracellular and intercellular products of protein degradation, has the potential to provide novel insights on endogenous proteolytic processing and their utility in disease diagnosis and prognosis. Along with the advances in MS instrumentation, a plethora of proteomics data analysis tools have been applied for direct use in peptidomics; however an evaluation of the currently available informatics pipelines for peptidomics data analysis has yet to be reported. In this study, we set off by evaluating the results of several popular MS/MS database search engines including MS-GF+, SEQUEST and MS-Align+ for peptidomics data analysis, followed by identification and label-free quantification using the well-established accurate mass and time (AMT) tag and newly developed informed quantification (IQ) approaches, both based on direct LC-MS analysis. Our result demonstrated that MS-GF+ outperformed both SEQUEST and MS-Align+ in identifying peptidome peptides. Using a database established from the MS-GF+ peptide identifications, both the AMT tag and IQ approaches provided significantly deeper peptidome coverage and less missing value for each individual data set than the MS/MS methods, while achieving robust label-free quantification. Besides having an excellent correlation with the AMT tag quantification results, IQ also provided slightly higher peptidome coverage than AMT. Taken together, we propose an optimal informatics pipeline combining MS-GF+ for initial database searching with IQ (or AMT) for identification and label-free quantification for high-throughput, comprehensive and quantitative peptidomics analysis.

Environmental Molecular Sciences Laboratory↗

In-Field Performance Testing of the Fork Detector for Quantitative Spent Fuel Verification

Expanding spent fuel dry storage activities worldwide are increasing demands on safeguards authorities that perform inspections. The European Atomic Energy Community (EURATOM) and the International Atomic Energy Agency (IAEA) require measurements to verify declarations when spent fuel is transferred to difficult-to-access locations, such as dry storage casks and the repositories planned in Finland and Sweden. EURATOM makes routine use of the Fork detector to obtain gross gamma and total neutron measurements during spent fuel inspections. Data analysis is performed by modules in the integrated Review and Analysis Program (iRAP) software, developed jointly by EURATOM and the IAEA. Under the framework of the US Department of Energy–EURATOM cooperation agreement, a module for automated Fork detector data analysis has been developed by Oak Ridge National Laboratory (ORNL) using the ORIGEN code from the SCALE code system and implemented in iRAP. EURATOM and ORNL recently performed measurements on 30 spent fuel assemblies at the Swedish Central Interim Storage Facility for Spent Nuclear Fuel (Clab), operated by the Swedish Nuclear Fuel and Waste Management Company (SKB). The measured assemblies represent a broad range of fuel characteristics. Neutron count rates for 15 measured pressurized water reactor assemblies are predicted with an average relative standard deviation of 4.6%, and gamma signals are predicted on average within 2.6% of the measurement. The 15 measured boiling water reactor assemblies exhibit slightly larger deviations of 5.2% for the gamma signals and 5.7% for the neutron count rates, compared to measurements. These findings suggest that with improved analysis of the measurement data, existing instruments can provide increased verification of operator declarations of the spent fuel and thereby also provide greater ability to confirm integrity of an assembly. These results support the application of the Fork detector as a fully quantitative spent fuel verification technique.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nanoscale building blocks in a novel lithium arsenotungsten bronze: Synthesis and characterization

We report on a novel compound Li{sub 3}AsW{sub 7}O{sub 25} obtained by solid-state reaction and characterized by diffraction and spectroscopic methods. The bronze-type compound crystallizes in the orthorhombic space group Pbca with a=724.38(3) pm, b=1008.15(4) pm, c=4906.16(17) pm and Z=8. The structure is built up by chains of WO{sub 6} octahedra interconnected by AsO{sub 4} tetrahedra and WO{sub 6} octahedra forming a polyhedral arrangement as seen in intergrowth tungsten bronzes. The X-ray single crystal structure refinement allows solving the complex arsenotungstate framework. The powder neutron diffraction data analysis locates the lithium atoms. Thermal analysis showed that Li{sub 3}AsW{sub 7}O{sub 25} is stable up to its melting at 1135(3) K followed by a decomposition at 1182(5) K. The Kubelka–Munk treatment of the UV–vis spectrum revealed a wide band gap in the range of 2.84–3.40 eV depending on the presumed electron transition type. - Graphical abstract: Crystal structure of Li{sub 3}AsW{sub 7}O{sub 25} showing different schematic components. - Highlights: • A report on a novel compound Li{sub 3}AsW{sub 7}O{sub 25} obtained by solid-state reaction. • Chains and nano-blocks of WO{sub 6} octahedra and AsO{sub 4} tetrahedra formed a structure like intergrowth tungsten bronzes. • X-ray diffraction allowed solving the complex arsenotungstate framework. • Powder neutron diffraction data analysis locates the lithium atoms. • UV–vis spectrum revealed the band-gap.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of Ambient Mass Spectrometry Rapid Analysis Methods for Trace Inorganics

Ambient mass spectrometry is being investigated as a new method for rapidly characterizing trace inorganic species, including nuclear materials. SRNL is currently developing electrospray ionization (ESI) and paper spray ionization (PSI) methods for mass spectrometry for the detection of trace inorganic compounds JEOL AccuTOF™-DART ® LP 4G mass spectrometer. Sample analysis generates a complex three-dimensional data set with 10 2 -10 3 individual mass spectra spread temporally. To improve the quality and ease of data extraction from this amount of information, a simple data analysis pipeline written in R/R Studio has been improved and expanded upon. Specifically, the software now has header inputs to set base input/output filenames, isotopes of interest, and a list of concentrations analyzed on the instrument. Using list-based structures to enable batch processing of many concentrations at once, it then loads each file, extracts the relevant intensities for masses of interest from each spectrum, and iterates through each concentration to generate graphs of internal standard & analyte correlations, measured isotope ratios, and total ion chromatograms. It then filters the data to remove points at background levels or at the detector saturation limit. Using this filtered data, the pipeline re-creates the graphs to reveal high-quality information from a low-quality raw dataset. All graphs of the R software then output to PowerPoint format. Additionally, faster 3D visualization functionality was added to the pipeline for viewing the entire data file produced by the instrument as an intensity map. With these data analysis tools ready, samples of strontium nitrate/yttrium nitrate as an analyte/internal standard combination were measured on the AccuTOF. From the filtered data, calibration curves were prepared and limits of detection (LOD) of 1 ppb for ESI-MS and 20 ppb for PSI-MS were obtained. The quality available from the calibration curves and the low limits of detection demonstrate the value of the instrument/analysis pipeline system in characterizing trace inorganics.

47 OTHER INSTRUMENTATION↗

Electrical Energy Storage Data Submission Guidelines, Version 2

Energy storage technologies are positioned to play a substantial role in power delivery systems. They have the potential to serve as an effective new resource to maintain reliability and allow for increased penetration of renewable energy. However, because of their relative infancy, there is a lack of knowledge about how these resources truly operate over time. A data analysis can help ascertain the operational and performance characteristics of these emerging technologies. Rigorous testing and a data analysis are important for all stakeholders to ensure a safe, reliable system that performs predictably on a macro level. Standardizing testing and analysis approaches to verify the performance of energy storage devices, equipment, and systems when integrating them into the grid will improve the understanding and benefit of energy storage over time from technical and economic vantage points. Demonstrating the life-cycle value and capabilities of energy storage systems begins with the data that the provider supplies for the analysis. After a review of energy storage data received from several providers, some of these data have clearly shown to be inconsistent and incomplete, raising the question of their efficacy for a robust analysis. This report reviews and proposes general guidelines, such as sampling rates and data points, that providers must supply for a robust data analysis to take place. Consistent guidelines are the basis of a proper protocol and ensuing standards to (1) reduce the time that it takes for data to reach those who are providing the analysis; (2) allow them to better understand the energy storage installations; and (3) enable them to provide a high-quality analysis of the installations. The report is intended to serve as a starting point for what data points should be provided when monitoring. Readers are encouraged to use the guidance in the report to develop specifications for new systems, as well as enhance current efforts to ensure optimal storage performance. As battery technologies continue to advance and the industry expands, the report will be updated to remain current.

25 ENERGY STORAGE↗

Combined use of computational chemistry and chemoinformatics methods for chemical discovery

Data analysis on numerical data by the computational chemistry calculations is carried out to obtain knowledge information of molecules. A molecular database is developed to systematically store chemical, electronic-structure, and knowledge-based information. The database is used to find molecules related to a keyword of “cancer”. Then the electronic-structure calculations are performed to quantitatively evaluate quantum chemical similarity of the molecules. Among the 377 compounds registered in the database, 24 molecules are found to be “cancer”-related. This set of molecules includes both carcinogens and anticancer drugs. The quantum chemical similarity analysis, which is carried out by using numerical results of the density-functional theory calculations, shows that, when some energy spectra are referred to, carcinogens are reasonably distinguished from the anticancer drugs. Therefore these spectral properties are considered of as important measures for classification.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tools for Visualization and Analysis of Small-Angle Neutron Scattering Data: Descriptions and Examples

A great deal of progress has been made in improving the data reduction experience for the SANS instruments at the SNS and HFIR at ORNL. The existing data reduction toolset, drtsans, makes it possible to integrate data analysis and visualization tools into the data reduction scripts, thereby providing new opportunities for more automated data processing for users of the SNS and HFIR. Here, the first set of tools developed is described with usage examples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Defining Modeling and Analysis Complexity Needs for Remediation - 18425

Many subsurface remedy decisions rely on model predictions or other types of data analyses to support site characterization and remedy selection, design, implementation, performance assessment, and closure. Thus, determining the appropriate level of complexity for modeling and data analysis is important to facilitate subsurface remedy decisions. Multiple factors are important in selecting the appropriate level of complexity in modeling and data analysis. For instance, the type and number of inputs required typically increases with increased complexity of analysis, and the ability to obtain or verify those inputs needs to be considered. The approach needs to establish the relationship between parameters or processes and contaminant transport and the detail of the description needed to meet the analysis objectives. Assessing the modeling complexity associated with the appropriate level of detail can be facilitated by considering complexity of the 1) modeling approach, 2) description of process, and 3) description of heterogeneity. As demonstrated by case studies, using a framework to guide determination of modeling and analysis complexity facilitates selection of the appropriate approach for the site situation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Searches for anomalous coupling in top-quark interaction with the W boson and b quark, along with searches for quark-flavor-changing neutral currents, in an analysis of data from the CMS experiment

The results of searches for effects beyond the Standard Model in processes of single top-quark production in the CMS experiment are presented. Anomalous contributions of the vector and magnetic types in top-quark interaction with the W boson and b quark and quark-flavor-changing neutral currents in top-quark interaction with the c or u quark via gluon exchange were studied. The respective analysis was performed with the aid of Bayesian neural networks. No statistically significant deviations were found, and upper limits on anomalous couplings at a 95% confidence level were set.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A General Framework for Progressive Data Compression and Retrieval

In scientific simulations, observations, and experiments, the transfer of data to and from disk and across networks has become a major bottleneck for data analysis and visualization. Compression techniques have been employed to tackle this challenge, but traditional lossy methods often demand conservative error tolerances to meet the numerical accuracy requirements of both anticipated and unknown data analysis tasks. Progressive data compression and retrieval has emerged as a promising solution, where each analysis task dictates its own accuracy needs. However, few analysis algorithms inherently support progressive data processing, and adapting compression techniques, file formats, client/server frameworks, and APIs to support progressivity can be challenging. Here, this paper presents a framework that enables progressive-precision data queries for any data compressor or numerical representation. Our strategy hinges on a multi-component representation that successively reduces the error between the original and compressed field, allowing each field in the progressive sequence to be expressed as a partial sum of components. We have implemented this approach with four established scientific data compressors and assessed its effectiveness using real-world data sets from the SDRBench collection. The results show that our framework competes in accuracy with the standalone compressors it is based upon. Additionally, (de)compression time is proportional to the number of components requested by the user. Finally, our framework allows for fully lossless compression using lossy compressors when a sufficient number of components are employed.

97 MATHEMATICS AND COMPUTING↗

THE FERMI LARGE AREA TELESCOPE ON ORBIT: EVENT CLASSIFICATION, INSTRUMENT RESPONSE FUNCTIONS, AND CALIBRATION

The Fermi Large Area Telescope (Fermi-LAT, hereafter LAT), the primary instrument on the Fermi Gamma-ray Space Telescope (Fermi) mission, is an imaging, wide field-of-view, high-energy {gamma}-ray telescope, covering the energy range from 20 MeV to more than 300 GeV. During the first years of the mission, the LAT team has gained considerable insight into the in-flight performance of the instrument. Accordingly, we have updated the analysis used to reduce LAT data for public release as well as the instrument response functions (IRFs), the description of the instrument performance provided for data analysis. In this paper, we describe the effects that motivated these updates. Furthermore, we discuss how we originally derived IRFs from Monte Carlo simulations and later corrected those IRFs for discrepancies observed between flight and simulated data. We also give details of the validations performed using flight data and quantify the residual uncertainties in the IRFs. Finally, we describe techniques the LAT team has developed to propagate those uncertainties into estimates of the systematic errors on common measurements such as fluxes and spectra of astrophysical sources.

79 ASTRONOMY AND ASTROPHYSICS↗