WE-FG-BRA-10: Radiodosimetry of a Novel Alpha Particle Therapy Targeted to Uveal Melanoma: Absorbed Dose to Organs in Mice

Purpose: The melanocortin-1 receptor (MC1R) is expressed in 94% of uveal melanomas and is described as an ideal target for this untreatable disease. MC1RL is a high affinity MC1R specific peptidomimetic ligand that can serve as a scaffold for therapeutic conjugates such as alpha particle emitting isotopes. The purpose of this study was to assess normal tissue distribution and risk as a result of using the DOTA chelator conjugated to MC1RL to deliver {sup 225}Ac: MC1RL-DOTA-{sup 225}Ac. Methods: 17 non-tumor bearing BALB/c mice were intravenously injected with the novel MC1RL-DOTA-{sup 225}Ac radiopharmaceutical with an average initial administered activity of 2.5 µCi. After the injection, three groups of animals (6, 6, and 5 per group) were euthanized at 24, 48, and 96 hour time points. A total of 11 organs of interest were harvested at each time point including kidneys and liver. Since the emitted alpha particles from {sup 225}Ac and its daughter products are not easy to detect directly, the isomeric gamma spectra were measured instead in the tissue samples using a modified Atomlab™ Gamma Counter (Biodex Medical Systems, Inc) and converted using factors for gamma ray abundance per alpha decay. Dosimetry was performed using measured radioactivity distribution in organs and the generalized internal dosimetry schema of MIRD pamphlet #21. Results: Our calculations have shown that the maximum absorbed dose was delivered to the liver with a total of 47 cGy per 96 hour period. The average dose per kidney was calculated to be 21 cGy. Heart, brain, lung, spleen, skin doses ranged from 0.01 to 1 cGy over the same time period. All animals gained weight over the 110 day decay period and no organ damage was observed by pathology. Conclusion: Based on our results, the risk of using the MC1RL-DOTA-{sup 225}Ac compound is relatively small in terms of deterministic radiation effects. Funding Support: NIH/NCI P50CA168536-03 Skin SPORE; NIH/NCI Phase I SBIR Contract #HHSN261201500067C; Imaging and Technology Center of Excellence at Moffitt. Disclosures and Conflict of Interest: Collaboration with Modulation Therapeutics, Inc.(MTI) and has been partially funded by sub-contracts from MTI via collaboration on a NIH/NCI phase I SBIR contract.

60 APPLIED LIFE SCIENCES↗

An experimental extrapolation technique using the Gafchromic EBT3 film for relative output factor measurements in small x-ray fields

Purpose: An experimental extrapolation technique is presented, which can be used to determine the relative output factors for very small x-ray fields using the Gafchromic EBT3 film. Methods: Relative output factors were measured for the Brainlab SRS cones ranging in diameters from 4 to 30 mm{sup 2} on a Novalis Trilogy linear accelerator with 6 MV SRS x-rays. The relative output factor was determined from an experimental reducing circular region of interest (ROI) extrapolation technique developed to remove the effects of volume averaging. This was achieved by scanning the EBT3 film measurements with a high scanning resolution of 1200 dpi. From the high resolution scans, the size of the circular regions of interest was varied to produce a plot of relative output factors versus area of analysis. The plot was then extrapolated to zero to determine the relative output factor corresponding to zero volume. Results: Results have shown that for a 4 mm field size, the extrapolated relative output factor was measured as a value of 0.651 ± 0.018 as compared to 0.639 ± 0.019 and 0.633 ± 0.021 for 0.5 and 1.0 mm diameter of analysis values, respectively. This showed a change in the relative output factors of 1.8% and 2.8% at these comparative regions of interest sizes. In comparison, the 25 mm cone had negligible differences in the measured output factor between zero extrapolation, 0.5 and 1.0 mm diameter ROIs, respectively. Conclusions: This work shows that for very small fields such as 4.0 mm cone sizes, a measureable difference can be seen in the relative output factor based on the circular ROI and the size of the area of analysis using radiochromic film dosimetry. The authors recommend to scan the Gafchromic EBT3 film at a resolution of 1200 dpi for cone sizes less than 7.5 mm and to utilize an extrapolation technique for the output factor measurements of very small field dosimetry.

60 APPLIED LIFE SCIENCES↗

Neutron Reference Benchmark Field Specifications: ACRR Polyethylene-Lead-Graphite (PLG) Bucket Environment (ACRR-PLG-CC-32-CL)

This report was put together to support the International Atomic Energy Agency (IAEA) REAL- 2016 activity to validate the dosimetry community’s ability to use a consistent set of activation data and to derive consistent spectral characterizations. The report captures details of integral measurements taken in the Annular Core Research Reactor (ACRR) central cavity with the Polyethylene-Lead-Graphite (PLG) bucket, reference neutron benchmark field. The field is described and an “a priori” calculated neutron spectrum is reported, based on MCNP6 calculations, and a subject matter expert (SME) based covariance matrix is given for this “a priori” spectrum. The results of 37 integral dosimetry measurements in the neutron field are reported.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Neutron Reference Benchmark Field Specification: ACRR 44 Inch Lead-Boron (LB44) Bucket Environment (ACRR-LB44-CC-32-CL)

This report was put together to support the International Atomic Energy Agency (IAEA) REAL- 2016 activity to validate the dosimetry community’s ability to use a consistent set of activation data and to derive consistent spectral characterizations. The report captures details of integral measurements taken in the Annular Core Research Reactor (ACRR) central cavity with the 44 inch Lead-Boron (LB44) bucket, reference neutron benchmark field. The field is described and an “a priori” calculated neutron spectrum is reported, based on MCNP6 calculations, and a subject matter expert (SME) based covariance matrix is given for this “a priori” spectrum. The results of 31 integral dosimetry measurements in the neutron field are reported.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Neutron Reference Benchmark Field Specification: ACRR Free-Field Environment (ACRR-FF-CC-32-CL)

This report was put together to support the International Atomic Energy Agency (IAEA) REAL- 2016 activity to validate the dosimetry community’s ability to use a consistent set of activation data and to derive consistent spectral characterizations. The report captures details of integral measurements taken in the Annular Core Research Reactor (ACRR) central cavity free-field reference neutron benchmark field. The field is described and an “a priori” calculated neutron spectrum is reported, based on MCNP6 calculations, and a subject matter expert (SME) based covariance matrix is given for this “a priori” spectrum. The results of 31 integral dosimetry measurements in the neutron field are reported.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Novel, Low-Cost, Light-Weight High Efficiency (H*10 Capable) Neutron Detector-Dosimeter

The goal of this project was to design, develop and validate a novel, spectroscopy enabled H*(10) neutron dosimetry system based on the tensioned metastable fluid detector (TMFD) sensor technology. The project team consisted of staff from Oak Ridge National Laboratory (ORNL), Purdue University (PU) and Sagamore Adams Laboratories, LLC (SAL). PU-SAL staff were tasked with the design, development, construction and testing of the H*TMFD hardware and software, along with developing the control and data acquisition software for comparison of predictions from H*TMFD against a commonly accepted and widely used industry standard system; for this project, the Li-I detector coupled to bonner spheres (LiI-BSS) system manufactured by Ludlum, Inc. was utilized as the reference (“gold”) standard – similar in terms of neutron spectroscopy enablement to another industry recognized, albeit, significantly higher cost (est. $300K) system referred to as “ROSPEC” (from BTI, Inc., which was not available for this project). ORNL staff were tasked with providing field-relevant guidance, apparatus and facilities for acquiring data against calibrated neutron sources, and comparing results of H*TMFD against LiI-BSS system predictions in a series of blind-tests conducted at ORNL. Over the course of 12 months, the PU-SAL-ORNL staff successfully accomplished the proposed technical and administrative tasks, inclusive of engaging in outreach to potential users of this technology in the DOE-wide infrastructure. The proposed tasks were successfully accomplished in timely manner; the follow-up type tasks pertaining to SBIR type Phases 2-3 were discussed and are initiated, inclusive of filing for intellectual property (IP) disclosures and possible patent filings by PU’s Office of Technology Commercialization (OTC). Two H*TMFD system architectures (see Exhibits 1 & 2 in the report) were developed and constructed for hand-portability by health-physicists (HPs) – the HP-H*TMFD, and the H*TMFD system which consists of a side-by-side mounted array of 4 TMFDs of 3 different sizes in sensitive volume (including one with borated fluid) that now simultaneously enables neutron energy spectroscopy: single bin for < 0.1 MeV, and 152 energy bins in the 0.1-15.2 MeV range; H*(10) dosimetry from ~5 μRem/h towards 10 R/h ranges. Several experiments were conducted using neutron sources in various configurations (shielded and unshielded). In direct comparison against the LiI-BSS industry standard (acquiring data for 26h each source), the H*TMFD system (acquiring data for ~6h for each source) offered H*(10) dose predictions for the most part accurate to within +/-10% for dose rates in the 100-300 μRem/h range. The LiI-BSS was impractical to use under ultra-low (~10 μRem/h) dose rate space, as also another metering device used at ORNL (Ludlum 4241L non-spectroscopy enabled) for which the lower limit is set by the manufacturer at 100 μRem/h. The enablement for efficient use in timely manner at the 10 μRem/h levels is deemed to be a strong enabling factor for H*TMFD for use in the DOE-nuclear laboratory arena. In terms of weight, the HP-H*TMFD weighs under ~5-7 lb.; the H*TMFD system weighs ~35-lb. As such, it is ~1/4 the weight of an LiI-BSS system weighing ~120 lb (LiI detector with 6 bonner spheres) and, ~1/2 the weight of ROSPEC. As a result of this activity, two involved post-doctoral student staff have now transitioned their knowledge and experiences to DOE’s Pacific Northwest National Laboratory (PNNL). A PU graduate student has also benefited from this project work which formed a principal basis for his Ph.D. dissertation work (in progress).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Biokinetic and Dosimetric Models [Slides]

Presentation describes internal dosimetry as an intersection of disciplines involving Physiology, Anatomy, Physics, Mathematics and Computer Science, which some people call "The art of Internal Dosimetry". The basic components for internal dose calculations are: Biokinetic (metabolic) models describing the intake, distribution, retention and excretion of radionuclides in the body, Dosimetric models describing the interaction of radiation within the several body organs and tissues, and System of dose limitation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Au-198 and TLD-600 results from IER-593 Godiva irradiations

This report summarizes the results from dosimetry packets deployed during a nominally 250 ◦C temperature rise Godiva IV burst. Dosimetry packets including Bare Au foils, Cd covered Au foils, and Thermoluminescent Dosimeters (TLDs) were deployed at five positions around Godiva at a height corresponding to the center height of the HEU fuel.

61 RADIATION PROTECTION AND DOSIMETRY↗

PLA Renewable Bio Polymer Based Solid-State Gamma Radiation Detector-Dosimeter for Biomedical and Nuclear Industry Applications

Polylactic acid (PLA) as a “green,” renewable corn-soy based polymer resin was assessed as a novel solid-state detector for rapid-turnaround gamma radiation dosimetry in the 1–100 kGy range–of significant interest in biomedical and general nuclear industry applications. Co-60 was used as the source of gamma photons. It was found that PLA resin responds well in terms of rheology and porosity metrics with an absorbed gamma dose (Dg). In this work, rheological changes were ascertained via measuring the differential mass loss ratio (MLR) of irradiated PLA placed within PTFE-framed (40 mm × 20 mm × 0.77 mm) cavities bearing ~0.9 g of PLA resin and pressed for 12–16 min in a controlled force hot press under ~6.6 kN loading and platens heated to 227 °C for the low Dg range: 0–11 kGy; and to 193 °C for the extended Dg range: 11–120 kGy. MLR varied quadratically from 0.05 to ~0.2 (1σ ~ 0.007) in the 0–11 kGy experiments, and from 0.05 to ~0.5 (1σ ~0.01) in the 0–120 kGy experiments. Rheological changes from gamma irradiation were modeled and simultaneously correlated with void-pocket formations, which increase with Dg. A single PLA resin bead (~0.04 g) was compressed 5 min at 216 °C in 0–16 kGy experiments, and compressed 2 min at 232 °C in the 16–110 kGy experiments, to form sturdy ~100 µm thick wafers in the same press. Aggregate coupon porosity was then readily measurable with conventional optical microscope imaging and analyzed with standard image processing; this provided complementary data to MLR. Average porosity vs. dose varied quadratically from ~0 to ~15% in the 0–16 kGy range and from ~0 to ~18% over the 16–114 kGy range. These results provide evidence for utilizing “green”/renewable (under $0.01) PLA resin beads for rapid and accurate (+/-5–10%) gamma dosimetry over a wide 0–120 kGy range, using simple to deploy mass and void measuring techniques using common laboratory equipment.

61 RADIATION PROTECTION AND DOSIMETRY↗

An Evaluation of Bipolar Junction Transistors as Dosimeter for Megavoltage Electron Beams

Dosimetry is an extremely important field in medical applications of radiation and nowadays, electron beam is a good option for superficial tumor radiotherapy. Normally, the applied dose to the patient both in diagnostic and therapy must be monitored to prevent injuries and ensure the success of the treatment, therefore, we should always look for improving of the dosimetric methods. Accordingly, the aim of this work is about the use of a bipolar junction transistor (BJT) for electron beam dosimetry. After previous studies, such an electronic device can work as a dosimeter when submitted to ionizing radiation of photon beam. Actually, a typical BJT consists of two PN semiconductor junctions resulting in the NPN structure device, for while, and each semiconductor is named as collector (C), base (B) and emitter (E), respectively. Although the transistor effect, which corresponds to the current amplification, be accurately described by the quantum physics, one can utilize a simple concept from the circuit theory: the base current IB (input signal) is amplified by a factor of β resulting in the collector current IC (output signal) at least one hundred times greater the IB. In fact, the BJT is commonly used as a current amplifier with gain β=I{sub C}/I{sub B}, therefore, it was noticed that this parameter is altered when the device is exposed to ionizing radiation. The current gain alteration can be explained by the trap creation and the positive charges build up, beside the degradation of the lattice structure. Then, variations of the gain of irradiated transistors may justify their use as a dosimeter. Actually, the methodology is based on the measurements of the I{sub C} variations whereas I{sub B} is maintained constant. BC846 BJT type was used for dose monitoring from passive-mode measurements: evaluation of its electrical characteristic before and after irradiation procedure. Thus, IC readings were plotted as a function of the applied dose in 6 MeV electron beam from a linear accelerator, Clinac iX. The results show that this new methodology could be an alternative to study the dose in superficial tumors in radiation oncology. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using Radiochromic Films to Characterize the Dispersion of ZrO{sub 2} Nano-sized Grain Clusters in Protective Polymer Composites

Radiation dosimetry is commonly used to prevent deterministic radiation effects in high dose medical procedures. Radiochromic films find nowadays widely application in radiotherapy, interventional procedures and CT exams for isodose and maximum skin dose measurements. Moreover the size of the irradiated area and its distribution can be performed through the reading of the individual components in the RGB-spectrum. Particularly, radiochromic film has multiple advantages over alternative dosimeters for low-kV X-rays dosimetry. Concerned to spatial resolution it is far superior to that of ionization chambers and thermoluminescent dosimeters. For high energy photon fields (keV to MeV) the most used radiochromic film commercially available belongs to the EBT Gafchromic{sup R} series. On the other hand, for low energy photon fields in the x-ray range (20 kVp to 200 kVp) the best choice belongs to the XR-QA Gafchromic{sup R} film series. In this work we demonstrate the possibility of generating 2D images of thin polymeric composites films using EBT3 and XR-QA2 Gafchromic{sup R} films exposed to 6 MeV and 40 keV x-ray photons, respectively, using the digital filtering tools of the ImageJ{sup R} free software. In this context, EBT3 films were placed on the surface of a rigid anthropomorphic phantom. Then, they were covered with a thermoplastic mask made of PCL polymer. This setup was then exposed to 2.0 Gy absorbed dose in the Linear Accelerator beam. The EBT3 films were then scanned in the high resolution mode in a commercial scanner and the images subsequently treated with digital filters. It is somehow possible to see the image of the thermoplastic mask in the scanned image. However, in the treated image it is easy to observe the mask arrangement. The unexpected phenomenon here is the EB3 film ability to detect the attenuation of high energy photons by a plastic material, which in turn has a very low mass-energy attenuation coefficient, producing a very clear 2D image. This result is discussed in terms of the high Z halides added to the sensitive layer of EB3 film, once the main components are C (42.3%), H (39.7%) and O (16.0%)1-2. Based on the above results, we have speculated about the abilities of XR-AQ films in the detection of the distribution of nano-sized particles that has high mass-energy attenuation coefficients for low energy x-rays, in polymer composites. In another investigation we tested the ability of XR-QA2 Gafchromic{sup R} films to evaluate the dispersion of ZrO{sub 2} nano-sized grain clusters in protective composites. The P(VDFTrFE)/ ZrO{sub 2} film was sandwiched between two XR-QA2 radiochromic films. In this setup, one radiochromic film is directly exposed to 100 mGy of the x-rays beam and another one measures the attenuated beam. After storage for 24 hours at room temperature under no light conditions, the irradiated radiochromic films were scanned under the same conditions in order to obtain a more reliable result. All films were scanned using the same size ROI in high resolution mode and saved as tagged image file format (TIFF). The untreated scanned image of the XR-AQ2 film directed exposed to the X-ray beam and the correspondent treated image with digital filters are shown. The untreated and treated image of the XR-AQ2 film that was exposed to the attenuated x-ray beam is shown. The image treated with digital filters seems to reproduce the dispersion of ZrO{sub 2} nano-sized grain clusters in the P(VDF-TrFE) copolymer matrix. This result is also discussed in terms of the high Z halides added to the sensitive layer of XR-AQ2 film and compared to the MEV images obtained from the P(VDF-TrFE)/ZrO{sub 2} composites. The results indicate a clear correlation between the 2D radiochromic image and the MEV photography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing Fluence as a Function of Areal Density for 1 and 14 MeV Neutrons Transported Through Air

Computing neutron dosimetry involves transporting neutrons [n] from a source to a sink, determining the neutron heating within the sink and multiplying the neutron heating by a quality factor to compute the dose equivalent. The space and energy dependent neutron fluence is a measure of the amount of neutrons crossing a particular surface area, about a particular energy and is given in units of [n/cm{sup 2}]. Microscopic cross sections are given in units of area and vary by isotope and reaction type as a function of energy. The product of the atom density of a particular atom in a specie and the microscopic cross section of a particular reaction results in the macroscopic cross section of a particular reaction, given in units of per length [1/cm] as a function of energy. Summing the macroscopic cross sections of all isotopes, and all collisions resulting in heating, within a volume, results in a total collision heating macroscopic cross section for that volume. The product of the energy and spatial dependent collision heating macroscopic cross section and the energy and spatial dependent fluence, within an energy group, results in a collision heating reaction density for that particular reaction in that energy group. Weighting each energy group's collision heating reactions, with the corresponding energy dependent particle damage per collision heating event (usually biological damage), and then integrating over energy and volume results in the delivered dose. Therefore understanding dose delivery involves examining the spatial and energy (and time) dependent fluence behavior. Because of the coupled energy and space dependence of the heating weighting and macroscopic cross sections, the fluence is not so easily separable in energy and space; however, the energy integrated fluence can be used as a first order approximation of the relative magnitude of reactions as a function of space. Here we examine the first part in the dosimetry calculation process, transporting neutrons from source to sink, as applied to neutron transport in air, examining characteristics of the fluence. Presented here is analysis regarding the nature of the fluence peak between 10 g/cm{sup 2} and 100 g/cm{sup 2} for a typical air transport calculation. Due to the high concentration of nitrogen and oxygen isotopes of these elements, these isotopes tend to dominate the transport. From the analysis presented here, the fluence peak is the result of scatter back and forth across the peak regime, and (n,2n) has a minimal (<4%) contribution. Further evidence of minimal (n,2n) impact in the 10-100 g/cm{sup 2} span includes the 1 MeV fluence peak being so much larger than the 14 MeV peak; where 1 MeV is not above the (n,2n) threshold. Also presented here is the usefulness of using tally tagging with cell flagging to further dissect the nature of the fluence. These technologies allow us to understand the originating volume that makes a contribution to a scoring regime. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

A 3D detailed breast model for dose estimation in mammography - Paper 14

The risk of radiation-induced breast cancer in mammography should be paid more attention for the number of women choosing mammography for breast cancer screening is increasing, and the recommended tissue weighting factors for breast tissue of ICRP changed from 0.05 in 1990 to 0.12 in 2007. The average dose to the glandular tissue is regarded as the most reasonable dose descriptor related to the risk of breast cancer induced by ionizing radiation. The IAEA protocol for breast dosimetry in mammography at present is based on the calculations of Dance which were based on very simple models of the breast. Therefore it is necessary to construct a more detailed breast model in order to estimate the dose more precisely. A 3D detailed breast model is constructed and Monte Carlo stimulation of mammography is performed based on this model in this paper. A series of glandular tissue dose conversion coefficients for mammography based on the 3D detailed breast model were calculated, which provide available data for the mammographic dosimetry assessment. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Implementation of a new dose record keeping system - Paper 45

During 2013, AWE implemented a new dosimetry system. As such events occur every twenty years or so, it was considered a major project that would require close collaboration between the end user, supplier and the regulator. This paper describes the journey taken by the project team to ensure a seamless transition from the current system to the newly approved dosimetry database. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Parallel Monte Carlo Methods for Heterogeneous Hardware Computer Systems Using GPUs and Coprocessors: Recent Development of ARCHER Code - Paper 54

Traditional methods of accelerating Monte Carlo (MC) calculations typically use CPUs as the computing unit. The parallelism is based upon multithreading on a multi-core processor, and message passing interface (MPI) across many processors and nodes. In recent years, the hardware accelerators have been introduced by the high performance computing industry as an alternative approach to achieve massive parallelism. Hardware accelerators have the advantage of high Floating-point Operations Per Second (FLOPS) and high energy efficiency. Examples include graphics processing units (GPUs) and coprocessors. Compute-intensive programs can be off-loaded to them to be concurrently executed by hundreds or thousands of active threads. Existing production MC codes, however, cannot be directly compiled or executed on the new platforms. It is therefore necessary to rewrite or redevelop the code using the hardware accelerator specific programming models and APIs. Several studies have been conducted on using GPUs to accelerate MC calculations in reactor analysis and medical physics. In this paper, we present the recent progress at Rensselaer Polytechnic Institute (RPI) in developing a new parallel MC code called ARCHER (Accelerated Radiation-transport Computations in Heterogeneous Environments) for coupled photon-electron transport simulations. The code is designed as a test bed to evaluate the efficacy of heterogeneous computing systems for low-cost MC-based radiation dosimetric calculations. The code has three variants corresponding to three parallel hardware platforms: ARCHER-CPU (multi-core CPU), ARCHER-GPU (Nvidia GPU) and ARCHER-COP (Intel Xeon Phi coprocessor). The code has been used for several applications, including CT imaging dosimetry, radiotherapy dosimetry and radiation shielding design. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Tensioned metastable fluid detector sensing technology for multifarious-multiscale applications in the nuclear fuel cycle

The nuclear fuel cycle presents formidable 10 30+ multiscale challenges for high-efficiency spectroscopic sensing of alpha-neutron-fission radiation signatures amidst extreme gamma-beta radiation backgrounds at various stages of the cycle; it involves diverse arenas ranging from continuous/pulsed power production, security/safeguards, spent fuel, environmental remediation, and personnel health-dosimetry. This paper discusses the novel tensioned metastable fluid detector (TMFD) sensor technology. It discusses the results of studies demonstrating extreme (10 4 Sv/h) gamma-beta field blind high intrinsic efficiencies (80–100%) for neutron-alpha-fission radiation spectrometric detection. Example studies discussed in this paper include Neutron detection with spectroscopy; H*10 neutron radiation dosimetry upwards from ultra-low10 −2 µSv/h levels; Air and/or liquid-borne trace (10 –3 Bq/mL) quantity, 1 keV energy resolved alpha/fission spectroscopy for Rn/Po/U/Pu/Am environmental isotope assays at 106:1 (β:α) ratios; Directional-position enabled extended standoff tracking of neutron emitting (shielded/unshielded) special nuclear materials while stationary or moving at highway speeds; and, U.S. Department of Energy nuclear complex wide nuclear waste reprocessing, criticality safety, health physics, and environmental applications.

Alpha-fission-neutron spectrometry↗

Meeting the imperative to accelerate environmental bioelectromagnetics research

Highlights: • Concerns mount about adverse health effects of low-level radiofrequency (RF) radiation. • Bioelectronics and environmental RF effects research both need an omics platform. • Standard bioelectromagnetic data models would advance dosimetry and omics work. • Steps toward developing standards and a shared research platform are proposed. In this article, the author draws on his experience in the world of geospatial information technology standards to suggest a path toward acceleration of bioelectromagnetics science. Many studies show biological effects of extremely low frequency (ELF) and radiofrequency (RF) radiation despite that fact that the radiation is too weak to cause temperature changes in biological features. Considered together in worst case scenarios, such effects, many of which appear to have long latencies, could have potentially disastrous consequences for the health and safety of humans and wildlife. Other studies show no such effects, and in both cases, often there are significant research quality deficits that make it difficult to draw firm conclusions from the data. The progress of bioelectromagnetics science is retarded by a lack of standard data models and experimental protocols that could improve the overall quality of research and make it easier for researchers to benefit from omics-related bioinformatics resources. {sup C}ertainty of safety{sup }of wireless devices used in digital communications and remote sensing (radar) is impossible without dosimetry standards that reflect the effects of non-thermal exposures. Electrical signaling in biological systems, a poorly funded research domain, is as biologically important as chemical signaling, a richly funded research domain, and these two types of signaling are inextricably connected. Entreprenuerial scientists pursuing bioelectronic innovations have begun to attract new funding. With appropriate institutional coordination, this new funding could equally benefit those investigating environmental effects of ELF and RF radiation. The author proposes a concerted effort among both bioelectronics technology stakeholders and environmental bioelectromagnetics science researchers to collaborate in developing institutional arrangements and standard data models that would give the science a stronger bioinformatics platform and give researchers better access to omics data. What is proposed here is essentially a bioelectromagnetics omics initiative.

54 ENVIRONMENTAL SCIENCES↗

Dosimetrically Triggered Adaptive Intensity Modulated Radiation Therapy for Cervical Cancer

Purpose: The widespread use of intensity modulated radiation therapy (IMRT) for cervical cancer has been limited by internal target and normal tissue motion. Such motion increases the risk of underdosing the target, especially as planning margins are reduced in an effort to reduce toxicity. This study explored 2 adaptive strategies to mitigate this risk and proposes a new, automated method that minimizes replanning workload. Methods and Materials: Thirty patients with cervical cancer participated in a prospective clinical study and underwent pretreatment and weekly magnetic resonance (MR) scans over a 5-week course of daily external beam radiation therapy. Target volumes and organs at risk (OARs) were contoured on each of the scans. Deformable image registration was used to model the accumulated dose (the real dose delivered to the target and OARs) for 2 adaptive replanning scenarios that assumed a very small PTV margin of only 3 mm to account for setup and internal interfractional motion: (1) a preprogrammed, anatomy-driven midtreatment replan (A-IMRT); and (2) a dosimetry-triggered replan driven by target dose accumulation over time (D-IMRT). Results: Across all 30 patients, clinically relevant target dose thresholds failed for 8 patients (27%) if 3-mm margins were used without replanning. A-IMRT failed in only 3 patients and also yielded an additional small reduction in OAR doses at the cost of 30 replans. D-IMRT assured adequate target coverage in all patients, with only 23 replans in 16 patients. Conclusions: A novel, dosimetry-triggered adaptive IMRT strategy for patients with cervical cancer can minimize the risk of target underdosing in the setting of very small margins and substantial interfractional motion while minimizing programmatic workload and cost.

62 RADIOLOGY AND NUCLEAR MEDICINE↗