Effectiveness of multi-stage cooling processes in improving the CH 4 -hydrate saturation uniformity in sandy laboratory samples

Laboratory-created samples of methane hydrate (MH)-bearing media are a necessity because of the rarity and difficulty of obtaining naturally-occurring samples. The hypothesis that the inevitable heterogeneity in the phase saturations of the laboratory samples may lead to unreliable and non-repeatable results provided the impetus for us to undertake this study, which aimed to determine the conditions under which maximum uniformity can be achieved. To that end, we designed four experiments involving different multi-stage cooling regimes (in terms of their duration and number of stages) to induce MH formation under excess-water conditions. In the absence of direct visualization capabilities, we analysed the experimental results by means of numerical simulation, which provided high-resolution predictions of the spatial distributions of the phase saturations in the cores and enabled the estimation of the parameters controlling the kinetic MH-formation behaviour through history-matching. Analysis of the numerical results indicated that, under the conditions of the experiments and with the design of the reactor, significant heterogeneities in phase saturation distributions were observed in all cases, leading to the conclusion that it is not possible to obtain cores with uniform phase saturation. Additionally, contrary to expectations, heterogeneities increased with the number of cooling stages and the duration of cooling, and this was attributed to imperfect insulation of the upper part of the reactor. A set of simulations involving perfect insulation of the reactor top confirmed the validity of this assumption: (a) predicting the formation of high-uniformity MH-bearing cores that became more homogeneous as the number of cooling stages and the length of the cooling period increased; and (b) providing important information for the improvement of the standard design of the experimental apparatus for the laboratory creation of MH-bearing cores using the excess water method.

42 ENGINEERING↗

A transmissive concentrator photovoltaic module with cells directly cooled by silicone oil for solar cogeneration systems

Hybrid concentrator photovoltaic-thermal systems can cogenerate electricity and heat by beam-splitting incoming concentrated light onto photovoltaic cells and a thermal receiver to increase total conversion efficiency and potentially reduce system cost. To demonstrate this, we have designed and prototyped a transmissive spectrum-splitting concentrator photovoltaic module that maximizes solar energy conversion by utilizing the entire solar spectrum. Visible light is collected using infrared-transmissive triple-junction photovoltaic cells to achieve an in-band module efficiency of 43.3% for light of wavelength λ < 873 nm, while 44.2% of out-of-band light with λ > 873 nm is transmitted through for collection by a thermal receiver. During testing on a dual-axis tracked parabolic concentrator dish at up to 166 suns, cell temperatures were maintained at 119 °C or below via a novel active cooling method. This cooling system strictly flows silicone oil directly across both sides of the cells, without inhibiting optical transmission, as verified through experimentation and simulation. The module was validated outdoors for 572 sun·hrs, and achieved a maximum thermal receiver temperature of 180 °C. 86.1% of incident solar power is collected at 166 suns average concentration collectively among the electrical, cooling, and thermal receiver subsystems. The remaining 13.9% is lost to mirror reflectivity, dish shadowing, receiver reflection, and thermal losses. The ability to directly cool the cells with an inert silicone oil offers the potential for reduced system cost relative to previous transmissive hybrid concentrator photovoltaic-thermal systems, including microfluidic-cooled designs. This solar cogeneration capability is valuable in a wide range of commercial and industrial applications.

14 SOLAR ENERGY↗

Resilient cooling through geothermal district energy system

Decarbonization and resilience to heat waves have recently become high priorities for building and district energy systems. Geothermal coupled district heating and cooling systems that operate a water loop near ground temperature gain increasing adoption to support decarbonization. In these systems, vapor-compression machines, distributed in the energy transfer stations, lift the temperature up or down to the needs of the particular building. In principle, these systems can provide low-power, free cooling from the geothermal bore field during heat waves when electricity is often scarce. However, the performance of such a resilience operation mode and its implication on the energy system configuration and the sizing of the bore field and HVAC equipment is not yet understood. Consequently, we are assessing their resilience, power use and design implications under a scenario of a heat wave on five working days during which chillers are switched off to reduce electrical consumption. Our analysis is based on high-fidelity, coupled dynamic models of district energy, building-side HVAC and actual control logic, with whole building energy simulation used to assess thermal conditions in a 2004 vintage multi-zone office building in Chicago, IL. The results show that relying only on waterside economizer cooling, the indoor thermal conditions can be maintained in a tolerable range for the majority of the building zones with half the electrical energy compared to standard chiller operation. Thermal comfort in the hottest zones can be further improved by oversizing the cooling coil. However, the waterside economizer has significant implications on the system configuration and sizing: The geothermal bore field needs to be sized about 30% larger than the upper limit of the range observed for conventional geothermal systems. Nevertheless, if a central chiller plant is added, the bore field can be downsized to the typical design range. The latter configuration still allows compressor-less cooling during the heat wave with peak power reduced by 60% compared to the standard design and chiller operation.

15 GEOTHERMAL ENERGY↗

Flame dynamics and kinetic coupling of ammonia and dimethyl-ether in non-premixed cool and warm flames at elevated pressure

Developing advanced low-temperature combustion engines with ammonia-biofuel blends requires a comprehensive understanding of low-temperature flame dynamics and kinetic interactions between ammonia and oxygenated fuels at elevated pressures. This work aims to study the dynamics and kinetics of non-premixed Dimethyl Ether (DME)/Ammonia (NH 3 ) cool and warm flames, and their reignition to hot flames. A counterflow burner is employed to establish DME/NH 3 cool/warm flames at pressures up to 5 atm. The extinction limits of cool flame and the reignition limits of warm flame to hot flame are measured by varying NH 3 concentrations and compared to simulations to quantitatively examine the effects on DME/NH 3 flames. It is found that NH 3 inhibits low-temperature DME oxidation and results in lower cool flame extinction limits. Warm flames in the presence of NH 3 are observed for the first time, revealing a non-monotonic effect of NH 3 addition: a small amount of NH 3 presence enhances warm flame chemistry and promotes reignition to hot flames, while a high NH 3 concentration weakens the warm flame. This trend is further explained by 0-D PSR kinetic simulations and 1-D S-curve flame dynamic calculations. Three flame transition regimes between cool flames (CF), warm flames (WF), and hot flames (HF) by different levels of NH 3 additions at a specific strain rate are identified, namely WFHF reignition, WF-CF transition, and WF extinction. Reaction sensitivity analyses of OH at low temperatures show that NH3 inhibits DME oxidation through OH consumption via H-abstraction and the kinetic couplings of RO 2 /NH 2 , RO 2 /NO x , R/NO x , and O 2 QOOH/NO x further suppress the low-temperature branching. At intermediate-temperatures, NH 2 /NO x /HO 2 coupling promotes warm flames via the pathway NH 2 → H 2 NO → HNO → NO by converting O 2 → HO 2 → OH. At even higher NH₃ concentrations, radical termination reactions of NH 2 + NO/NO 2 and excessive OH consumption via H-abstraction inhibit the flame. The insights into the kinetic coupling between NH 3 and low-temperature chemistry at elevated pressure and its impact on the dynamics of cool-warm-hot flame transitions will contribute to advancing combustion technologies with reduced emissions and improved energy-efficiency.

42 ENGINEERING↗

Optimizing mixed cool thermal storage systems across a connected community

A high level of electric demand flexibility must be integrated into our building infrastructure to enable greater renewable energy penetration in the grid. In the U.S., 9% of electricity generated is used to cool buildings in a periodic manner, making this end-use an ideal target for active management through cool thermal energy storage (CTES) technologies. Historic uses for CTES are designed around central chilled water plants, but these systems cool less than 25% of U.S. commercial floorspace. Emerging technologies are under development to serve the many smaller distributed cooling systems, such as rooftop units (RTUs), and have the potential to add CTES to an additional 66% of cooled commercial floorspace. However, these unitary thermal storage systems (UTSS) lack the modeling and analysis tools to evaluate them in the future interactive grid context. Here, this study develops the modeling and optimization tools necessary to simultaneously examine central and distributed ice storage systems within the multi-building, connected community context. An integrated simulation-optimization workflow is created to allow for rapid customized analysis. Results demonstrate the energy and flexibility tradeoffs of various implementations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance analysis of single-phase immersion cooling system of data center using FC-40 dielectric fluid

Immersion cooling technologies have become an emerging cooling method for data center cooling. The studies available in open literature dealt with immersion cooling performance of data servers using mineral oil, EC-100, and Opticool 872552, but the studies focusing on the performance of FC-40 dielectric fluid is not available. Therefore, this study aimed to develop a single-phase liquid immersion cooling system using FC-40 dielectric fluid for a 1U (44.45 mm height) data server. The present study experimentally investigated the influence of different design and operating parameters, including the inlet/outlet port configuration (T and Z configurations), the bypass effect, the flowrate (1–3 LPM), the heating load (200–600 W), the inlet fluid temperature (15–35 °C), the presence of suction fan with various arrangements, and different heat sink bases (solid base, vapor chamber and heat pipe base). The results showed that the T-configuration could provide a 12.6% and 0.5–2.8 °C reduction in thermal resistance and case temperature compared to the Z-configuration, respectively. Additionally, the heat sink with heat pipe and vapor chamber base offered a minimum case temperature of 56.7 °C and 55.2 °C against the 60 °C experienced in the heat sink with flat plate base, respectively.

42 ENGINEERING↗

Ultra-low thermal resistance and pressure drop copper and copper-tungsten diamond-shaped pin fin cold plates for liquid cooling of electronics

Modern and future data centers face increasing cooling challenges due to increasing chip thermal design power and die size, along with the need to reduce energy consumption used for cooling. High performance cooling solutions that maintain a low chip junction temperature are needed to ensure electronics reliability. This work develops an ultra-low thermal resistance and low pressure drop 75 mm × 75 mm cold plate, intended for next-generation electronics cooling. The cold plate features an array of diamond-shaped pin fins and integrated copper tungsten heat spreader, selected for its low coefficient of thermal expansion which reduces thermomechanical deformation and allows for closer integration of the cold plate with silicon dies. Starting with 300 candidate designs, three-dimensional computational fluid dynamics simulations predict the thermal-hydraulic performance of cold plate subsections. The highest performing geometries are evaluated with high fidelity simulations. Four cold plates are manufactured for experiments: three with diamond-shaped pin fins and one with straights fins for comparison purposes. The cold plates are fabricated from copper-tungsten (CuW), copper (Cu), or aluminum-silicon-magnesium alloy (AlSi10Mg). The diamond-shaped pin fins achieve a roughly 15 % lower thermal resistance compared to the conventional straight fin microchannel. The highest performing design achieves a chip-to-coolant (including thermal interface material) thermal resistance of 9.0 K/kW in CuW and 6.9 K/kW in Cu under a 1 kW heat load with an inlet-to-outlet pressure drop of 9.0 kPa and water as the working fluid. This work demonstrates ultra-low thermal resistance and pressure drop cold plates for large die, high heat load applications, and shows that CuW is an attractive cold plate material for improved reliability in next generation data center cooling.

Coefficient of thermal expansion↗

Analysis of basic airflow configurations for separate sensible and latent cooling systems with indoor air recirculation

Separate sensible and latent cooling (SSLC) is a technology with efficiency and comfort advantages over conventional cooling systems used for space conditioning of buildings. Using multiple cooling processes at different temperatures allows SSLC to save energy by raising the evaporation temperature of the sensible cooling process. In this paper, all possible airflow configurations of SSLC systems are enumerated under the following constraints: exactly two heat exchangers are used, and air is recirculated to the conditioned space (no exhaust or outdoor air treatment). Seven designs are identified, with varying free operating variables, and each is modeled. Analysis reveals that several configurations are equivalent, and there is only one unique basic airflow SSLC configuration: the one with the sensible and latent heat exchangers placed in series. The efficiency of the SSLC system is compared against that of the conventional system. Under standard conditions, an SSLC system can improve the coefficient of performance by 14.8%. In addition to the numerical simulation, the optimal operating condition of the basic air configuration of the SSLC system is derived analytically. The basic SSLC system is shown to offer the highest performance improvement when the outdoor temperature is relatively cool and the space sensible heat ratio is high.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

First benchmarked electron cooling simulations from first principles

We present the first microscopic electron cooling simulations from first principles with accurate prediction of cooling time. These simulations were performed using our previously developed numerical method, PHAD, which is the first efficient large-scale collisional numerical method in beam physics. The simulation results are benchmarked with the experimental data of the low energy bunched electron cooling of ion beams at the storage ring CSRm at the IMP facility in China. Here, we have accurately considered the nonlinear dynamics in the whole accelerator system in addition to the electron cooling section. As a result, our simulations correctly reproduced cooling times of the experiments from first principles and without any tuning or fitting parameters in the code.

43 PARTICLE ACCELERATORS↗

Generation and characterization of magnetized electron beam from a DC high voltage photogun for electron beam cooling application

One of the most challenging requirements for the proposed Electron-Ion Collider is the strong cooling of the proton beam, which is key to achieving the collider’s desired luminosity of order 10 33 -10 34 cm -2 s -1 . Magnetized bunched-beam electron cooling could be a means to achieve the required high luminosity, where strong cooling is accomplished inside a cooling solenoid where the ions co-propagate with an electron beam generated from a source immersed in a magnetic field. To increase the cooling efficiency, a bunched electron beam with high bunch charge and high repetition rate is required. This work describes the production and characterization of magnetized electron beam using a compact 300 kV DC high voltage photogun and bi-alkali antimonide photocathode. Beam magnetization was studied using a diagnostic beamline that includes viewer screens for measuring the shearing angle of the electron beamlet passing through a narrow upstream slit. Simulations and corresponding measurements of beam magnetization are presented as a function of laser spot size and magnetic field strength. Correlated beam emittance with magnetic field (0–0.15 T) at the photocathode was measured for various laser spot sizes. Measurements of photocathode lifetime were carried out at different magnetized electron beam currents up to 28 mA, and bunch charge up to 0.7 nC (not simultaneously).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Empirically verified analysis of dual pre-cooling system for hydrogen refuelling station

The dual cooling system at the California State University Los Angeles Hydrogen Research and Fueling Facility is analysed to predict the output hydrogen temperature in different ambient conditions. Initially, the facility was built with a coil chiller T20 cooling, sufficient for occasional fuelings. A flat plate evaporator system was added in series to resolve any issues for multiple fuelings even in the hottest weather. This study was commenced to verify the set points and determine the control requirements for the dual setup in order to inform future designs. A numerical-empirical model of the cooling system was developed by reverse engineering, using the station experimental measurements and database records. The subsystems are characterized separately but validated as a whole system imposing specific and standard operating conditions. The cooling model is tested with different inputs to validate the pre-set parameter variation of the cooling components. Ten scenarios were investigated to evaluate the fueling output parameters, testing two hydrogen temperature input trends (according to the facility initial conditions) and five ambient temperatures (from 15 °C to 35 °C). In closing, the simulation results have confirmed that the hydrogen output temperature remains within the range imposed by the SAE J2601 for each scenario studied, around -22 °C and -25 °C.

08 HYDROGEN↗

High Propane and Isobutane Adsorption Cooling Capacities in Zirconium-Based Metal–Organic Frameworks Predicted by Molecular Simulations

Adsorption cooling systems are emerging alternatives to traditional compression-based cooling systems due to their reduced electricity costs. Metal–organic frameworks (MOFs) have the potential to be ideal adsorbent materials for this application, as they can be tuned to have desired adsorption behavior for different refrigerants. In this study, we studied the adsorption behaviors of propane and isobutane, which are environmentally friendly refrigerants that have been recommended as substitutes for (hydro)chlorofluorocarbons, in two mesoporous Zr-based MOFs, namely, NU-1000 and NU-1003, which have the same topology but different pore sizes. Both MOFs showed high cooling capacities with the refrigerants, and for isobutane, the cooling capacities were 2 to 4 times higher than MIL-101, which is the only MOF with a previously reported isobutane adsorption cooling capacity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of spin-orbit coupling on laser cooling of BeI and MgI

We present the ab initio study of spin-orbit coupling effects on laser cooling of BeI and MgI molecules. Potential energy curves for the X{sup 2}Σ{sup +}{sub 1/2}, A{sup 2}Π{sub 1/2,3/2}, and 2{sup 2}Π{sub 3/2,1/2} states are calculated using multi-reference configuration interaction method plus Davidson corrections. Spectroscopic parameters of BeI and MgI are in excellent agreement with available experimental and theoretical values. The A{sup 2}Π{sub 3/2} state of MgI is a repulsive state. It is an unsuitable scheme for the A{sup 2}Π{sub 3/2}(υ′)← X{sup 2}Σ{sup +}{sub 1/2} (υ″) transition for laser cooling of MgI. Highly diagonally distributed Franck-Condon factors f{sub 00} for the A{sup 2}Π{sub 1/2,3/2} (υ′ = 0) ← X{sup 2}Σ{sup +}{sub 1/2} (υ″ = 0) transitions and suitable radiative lifetimes τ for the A{sup 2}Π{sub 1/2,3/2} (υ′ = 0) of BeI and MgI are obtained. Three laser wavelength drives are required for the A{sup 2}Π{sub 1/2,3/2}(υ′)←X{sup 2}Σ{sup +}{sub 1/2} (υ″) transitions of BeI and MgI. The proposed cooling wavelengths of BeI and MgI are both in the violet region. The results imply the feasibility of laser cooling of BeI and MgI, and that laser cooling of BeI is more possible.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Probing polymer crystallization at processing-relevant cooling rates with synchrotron radiation

Processing of polymeric materials to produce any kind of goods, from films to complex objects, involves application of flow fields on the polymer melt, accompanied or followed by its rapid cooling. Typically, polymers solidify at cooling rates which span over a wide range, from a few to hundreds of °C/s. A novel method to probe polymer crystallization at processing-relevant cooling rates is proposed. Using a custom-built quenching device, thin polymer films are ballistically cooled from the melt at rates between approximately 10 and 200 °C/s. Thanks to highly brilliant synchrotron radiation and to state-of-the-art X-ray detectors, the crystallization process is followed in real-time, recording about 20 wide angle X-ray diffraction patterns per second while monitoring the instantaneous sample temperature. The method is applied to a series of industrially relevant polymers, such as isotactic polypropylene, its copolymers and virgin and nucleated polyamide-6. Their crystallization behaviour during rapid cooling is discussed, with particular attention to the occurrence of polymorphism, which deeply impact material’s properties.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Laser system for Doppler cooling of ytterbium ion in an optical frequency standard

A laser system for Doppler cooling of ytterbium ion on the {sup 2}S{sub 1/2} → {sup 2}P{sub 1/2} transition in a single-ion optical frequency standard is developed. The second harmonic of a semiconductor laser with a wavelength of 739 nm is used for cooling. The laser frequency is doubled in a nonlinear BiBO crystal embedded in a ring resonator, which also serves as a reference for laser frequency stabilisation. Second-harmonic power of ∼100 μW is generated at a wavelength of 369.5 nm. Diode laser radiation is modulated by an electro-optic modulator at 14.75 GHz to generate a sideband exciting the {sup 2}S{sub 1/2} (F = 0) → {sup 2}P{sub 1/2} (F = 1) hyperfine component of the cooling transition that is not excited by resonant cooling light. The sideband relative intensity of a few percent proved to be sufficient to reduce the ion dwelling time in the {sup 2}S{sub 1/2} (F = 0) state to less than 10{sup -4} s and increase the cooling efficiency. (extreme light fields and their applications)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A new estimate of the chondrule cooling rate deduced from an analysis of compositional zoning of relict olivine

Compositional zoning in chondrule phenocrysts records the crystallization environments in the early solar nebula. We modeled the growth of olivine phenocrysts from a silicate melt and proposed a new fractional crystallization model that provides a relation between the zoning profile and the cooling rate. In our model, we took elemental partitioning at a growing solid-liquid interface and time-dependent solute diffusion in the liquid into consideration. We assumed a local equilibrium condition, namely, that the compositions at the interface are equal to the equilibrium ones at a given temperature. We carried out numerical simulations of the fractional crystallization in one-dimensional planar geometry. The simulations revealed that under a constant cooling rate the growth velocity increases exponentially with time and a linear zoning profile forms in the solid as a result. We derived analytic formulae of the zoning profile, which reproduced the numerical results for wide ranges of crystallization conditions. The formulae provide a useful tool to estimate the cooling rate from the compositional zoning. Applying the formulae to low-FeO relict olivine grains in type II porphyritic chondrules observed by Wasson and Rubin, we estimate the cooling rate to be ∼200-2000 K s{sup –1}, which is greater than that expected from furnace-based experiments by orders of magnitude. Appropriate solar nebula environments for such rapid cooling conditions are discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

THE RELATION BETWEEN COOL CLUSTER CORES AND HERSCHEL-DETECTED STAR FORMATION IN BRIGHTEST CLUSTER GALAXIES

We present far-infrared (FIR) analysis of 68 brightest cluster galaxies (BCGs) at 0.08 < z < 1.0. Deriving total infrared luminosities directly from Spitzer and Herschel photometry spanning the peak of the dust component (24-500 {mu}m), we calculate the obscured star formation rate (SFR). 22{sup +6.2}{sub -5.3}% of the BCGs are detected in the far-infrared, with SFR = 1-150 M{sub Sun} yr{sup -1}. The infrared luminosity is highly correlated with cluster X-ray gas cooling times for cool-core clusters (gas cooling time <1 Gyr), strongly suggesting that the star formation in these BCGs is influenced by the cluster-scale cooling process. The occurrence of the molecular gas tracing H{alpha} emission is also correlated with obscured star formation. For all but the most luminous BCGs (L{sub TIR} > 2 Multiplication-Sign 10{sup 11} L{sub Sun }), only a small ({approx}<0.4 mag) reddening correction is required for SFR(H{alpha}) to agree with SFR{sub FIR}. The relatively low H{alpha} extinction (dust obscuration), compared to values reported for the general star-forming population, lends further weight to an alternate (external) origin for the cold gas. Finally, we use a stacking analysis of non-cool-core clusters to show that the majority of the fuel for star formation in the FIR-bright BCGs is unlikely to originate from normal stellar mass loss.

79 ASTRONOMY AND ASTROPHYSICS↗

OHMIC HEATING SUSPENDS, NOT REVERSES, THE COOLING CONTRACTION OF HOT JUPITERS

We study the radius evolution of close-in extra-solar Jupiters under Ohmic heating, a mechanism that was recently proposed to explain the large observed sizes of many of these planets. Planets are born with high entropy and they subsequently cool and contract. We focus on two cases: first, that Ohmic heating commences when the planet is hot (high entropy); and second, that it commences after the planet has cooled. In the former case, we use analytical scaling and numerical experiments to confirm that Ohmic heating is capable of suspending the cooling as long as a few percent of the stellar irradiation is converted into Ohmic heating and the planet has a surface wind that extends to pressures of {approx}10 bar or deeper. For these parameters, the radii at which cooling is stalled are consistent with (or larger than) the observed radii of most planets. The only two exceptions are WASP-17b and HAT-P-32b. In contrast to the high entropy case, we show that Ohmic heating cannot significantly re-inflate planets after they have already cooled. This leads us to suggest that the diversity of radii observed in hot Jupiters may be partially explained by the different epochs at which they are migrated to their current locations.