Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Computing, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

User Guide for Sample Reduction at GP-SANS

This manual is intended as a quick guide for data reduction of GP-SANS data. It includes all necessary steps to do the data reduction based on absolute calibration using the open beam method and how to transfer the reduced data to the personal computer system. If any errors are coming up so that the reduction script is not functioning as intended, please contact the instrument scientist.

97 MATHEMATICS AND COMPUTING↗

Factoring numbers with a single interferogram

We construct an analog computer based on light interference to encode the hyperbolic function f({zeta}){identical_to}1/{zeta} into a sequence of skewed curlicue functions. The resulting interferogram when scaled appropriately allows us to find the prime number decompositions of integers. We implement this idea exploiting polychromatic optical interference in a multipath interferometer and factor seven-digit numbers. We give an estimate for the largest number that can be factored by this scheme.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental and Computational Analysis of the Solvent‐Dependent O 2 /Li + ‐O 2 − Redox Couple: Standard Potentials, Coupling Strength, and Implications for Lithium–Oxygen Batteries

Abstract Understanding and controlling the kinetics of O 2 reduction in the presence of Li + ‐containing aprotic solvents, to either Li + ‐O 2 − by one‐electron reduction or Li 2 O 2 by two‐electron reduction, is instrumental to enhance the discharge voltage and capacity of aprotic Li‐O 2 batteries. Standard potentials of O 2 /Li + ‐O 2 − and O 2 /O 2 − were experimentally measured and computed using a mixed cluster‐continuum model of ion solvation. Increasing combined solvation of Li + and O 2 − was found to lower the coupling of Li + ‐O 2 − and the difference between O 2 /Li + ‐O 2 − and O 2 /O 2 − potentials. The solvation energy of Li + trended with donor number (DN), and varied greater than that of O 2 − ions, which correlated with acceptor number (AN), explaining a previously reported correlation between Li + ‐O 2 − solubility and DN. These results highlight the importance of the interplay between ion–solvent and ion–ion interactions for manipulating the energetics of intermediate species produced in aprotic metal–oxygen batteries.

Kwabi, David G.↗

Experimental and Computational Analysis of the Solvent‐Dependent O 2 /Li + ‐O 2 − Redox Couple: Standard Potentials, Coupling Strength, and Implications for Lithium–Oxygen Batteries

Abstract Understanding and controlling the kinetics of O 2 reduction in the presence of Li + ‐containing aprotic solvents, to either Li + ‐O 2 − by one‐electron reduction or Li 2 O 2 by two‐electron reduction, is instrumental to enhance the discharge voltage and capacity of aprotic Li‐O 2 batteries. Standard potentials of O 2 /Li + ‐O 2 − and O 2 /O 2 − were experimentally measured and computed using a mixed cluster‐continuum model of ion solvation. Increasing combined solvation of Li + and O 2 − was found to lower the coupling of Li + ‐O 2 − and the difference between O 2 /Li + ‐O 2 − and O 2 /O 2 − potentials. The solvation energy of Li + trended with donor number (DN), and varied greater than that of O 2 − ions, which correlated with acceptor number (AN), explaining a previously reported correlation between Li + ‐O 2 − solubility and DN. These results highlight the importance of the interplay between ion–solvent and ion–ion interactions for manipulating the energetics of intermediate species produced in aprotic metal–oxygen batteries.

Kwabi, David G.↗

Behavior-based approach to misuse detection of a simulated SCADA system - 339

This paper presents the initial findings in applying a behavior-based approach for detection of unauthorized activities in a simulated Supervisory Control and Data Acquisition (SCADA) system. Misuse detection of this type utilizes fault-free system telemetry to develop empirical models that learn normal system behavior. Future monitored telemetry sources that show statistically significant deviations from this learned behavior may indicate an attack or other unwanted actions. The experimental test bed consists of a set of Linux based enterprise servers that were isolated from a larger university research cluster. All servers are connected to a private network and simulate several components and tasks seen in a typical SCADA system. Telemetry sources included kernel statistics, resource usages and internal system hardware measurements. For this study, the Auto Associative Kernel Regression (AAKR) and Auto Associative Multivariate State Estimation Technique (AAMSET) are employed to develop empirical models. Prognostic efficacy of these methods for computer security used several groups of signals taken from available telemetry classes. The Sequential Probability Ratio Test (SPRT) is used along with these models for intrusion detection purposes. The different intrusion types shown include host/network discovery, DoS, brute force login, privilege escalation and malicious exfiltration actions. For this study, all intrusion types tested displayed alterations in the residuals of much of the monitored telemetry and were able to be detected in all signal groups used by both model types. The methods presented can be extended and implemented to industries besides nuclear that use SCADA or business-critical networks. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Software Dependability

The purpose of this paper is to provide a brief introduction of Software Dependability and a summary of lessons learned. The components of Software Dependability vary among standards, however there is agreement among the standards that reliability, availability and maintainability are some the main components of dependability. Safety is also a main component is safety systems. Although reliability and safety are similar there is an additional difference, safety can withstand some level of fault tolerance. For the purposes of this discussion Software Dependability includes reliability, availability, maintainability and safety. Software Dependability: Trustworthiness of a computer system such that reliance can be justifiably placed on the service it delivers. Reliability, availability, and maintainability are aspects of dependability. Reliability: The ability of a system or component to perform its required functions under stated conditions for a specified period of time. Availability: The degree to which a system or component is operational and accessible when required for use. Often expressed as a probability. Maintainability: Speed and ease with which a program can be corrected or changed. Safety: a measure of the length of time the software system can be expected to run before failing in such a way as to cause a system hazard. (author)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision Environmental Radiation Monitoring System

A new precision low-level environmental radiation monitoring system has been developed and tested at Jefferson Lab. This system provides environmental radiation measurements with accuracy and stability of the order of 1 nGy/h in an hour, roughly corresponding to approximately 1% of the natural cosmic background at the sea level. Advanced electronic front-end has been designed and produced for use with the industry-standard High Pressure Ionization Chamber detector hardware. A new highly sensitive readout electronic circuit was designed to measure charge from the virtually suspended ionization chamber ion collecting electrode. New signal processing technique and dedicated data acquisition were tested together with the new readout. The designed system enabled data collection in a remote Linux-operated computer workstation, which was connected to the detectors using a standard telephone cable line. The data acquisition system algorithm is built around the continuously running 24-bit resolution 192 kHz data sampling analog to digital convertor. The major features of the design include: extremely low leakage current in the input circuit, true charge integrating mode operation, and relatively fast response to the intermediate radiation change. These features allow operating of the device as an environmental radiation monitor, at the perimeters of the radiation-generating installations in densely populated areas, like in other monitoring and security applications requiring high precision and long-term stability. Initial system evaluation results are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

(U) Energy-Dependent Perturbations of Scattering Cross Sections Using the PERT Card in MCNP6.2

The PERT card is used for first- and second-order perturbations of material densities, isotope densities, and isotope cross sections in the MCNP6.2 Monte Carlo code. Using the PERT card for firstand second-order sensitivities is straightforward. Reference 2 only looked at density perturbations with no energy dependence. This report looks at the sensitivity of a response to scattering cross sections as a function of energy and finds that there is a bug in the PERT capability. The SENSMG multigroup neutron sensitivity code was recently given the capability of computing sensitivities to user-specified reactions whose cross sections are available in a user-supplied NJOY output file. SENSMG uses the PARTISN multigroup discrete ordinates code for the transport. The NJOY-reaction capability is similar to that of SUSD3D, which also uses PARTISN for the multigroup transport. The PERT bug was identified by comparing MCNP6.2 outputs with SENSMG outputs. The next section of this report describes the test problem. Section III presents the MCNP6.2 PERT bug and proposes a solution. Section IV is a summary and conclusions. The SENSMG and MCNP input files are listed in the appendix.

07 ISOTOPE AND RADIATION SOURCES↗

Gamma and neutron detection modeling in the nuclear detection figure of merit (NDFOM) portal

The Nuclear Detection Figure Of Merit (NDFOM) portal is a database of objects and algorithms for evaluating the performance of radiation detectors to detect nuclear material. This paper describes the algorithms used to model the physics and mathematics of radiation detection. As a first-principles end-to-end analysis system, it starts with the representation of the gamma and neutron spectral fluxes, which are computed with the particle and radiation transport code MCNPX. The gamma spectra emitted by uranium, plutonium, and several other materials of interest are described. The impact of shielding and other intervening material is computed by the method of build-up factors. The interaction of radiation with the detector material is computed by a detector response function approach. The construction of detector response function matrices based on MCNPX simulation runs is described in detail. Neutron fluxes are represented in a three group formulation to treat differences in detector sensitivities to thermal, epithermal, and fast neutrons.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-resolution wall temperature measurements with distributed fiber optic sensors

Conventional approaches of surface temperature measurement are often unreliable, and other methods may not be practical in closed, high-temperature spaces. In this study, surface temperature measurements of the cooling panel of a natural circulation facility were performed with fiber optic distributed temperature sensors (DTS). High resolution surface temperature profiles of the cooling panel were acquired under two steady experimental conditions, and compared with measurements performed with nearby thermocouples. The total measurement error of the DTS results presented has been estimated to be ±4.4 °C. The findings reflected herein show that these DTS can reasonably measure surface temperature when installed with the methods developed in this study. Through the analysis of the DTS data collected, the interesting behavior of the cooling panel was revealed, providing new insights on the system's behavior that may be beneficial to the design and optimization of such heat transfer devices. These sensors can also provide the measurement density necessary for validation efforts with highly-resolved prediction methods such as finite element analysis (FEA) or computational fluid dynamics (CFD).

47 OTHER INSTRUMENTATION↗

Solid waste bin detection and classification using Dynamic Time Warping and MLP classifier

Highlights: • Solid waste bin level detection using Dynamic Time Warping (DTW). • Gabor wavelet filter is used to extract the solid waste image features. • Multi-Layer Perceptron classifier network is used for bin image classification. • The classification performance evaluated by ROC curve analysis. - Abstract: The increasing requirement for Solid Waste Management (SWM) has become a significant challenge for municipal authorities. A number of integrated systems and methods have introduced to overcome this challenge. Many researchers have aimed to develop an ideal SWM system, including approaches involving software-based routing, Geographic Information Systems (GIS), Radio-frequency Identification (RFID), or sensor intelligent bins. Image processing solutions for the Solid Waste (SW) collection have also been developed; however, during capturing the bin image, it is challenging to position the camera for getting a bin area centralized image. As yet, there is no ideal system which can correctly estimate the amount of SW. This paper briefly discusses an efficient image processing solution to overcome these problems. Dynamic Time Warping (DTW) was used for detecting and cropping the bin area and Gabor wavelet (GW) was introduced for feature extraction of the waste bin image. Image features were used to train the classifier. A Multi-Layer Perceptron (MLP) classifier was used to classify the waste bin level and estimate the amount of waste inside the bin. The area under the Receiver Operating Characteristic (ROC) curves was used to statistically evaluate classifier performance. The results of this developed system are comparable to previous image processing based system. The system demonstration using DTW with GW for feature extraction and an MLP classifier led to promising results with respect to the accuracy of waste level estimation (98.50%). The application can be used to optimize the routing of waste collection based on the estimated bin level.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dynamics from noisy data with extreme timing uncertainty

Imperfect knowledge of the times at which ‘snapshots’ of a system are recorded degrades our ability to recover dynamical information, and can scramble the sequence of events. In X-ray free-electron lasers, for example, the uncertainty—the so-called timing jitter—between the arrival of an optical trigger (‘pump’) pulse and a probing X-ray pulse can exceed the length of the X-ray pulse by up to two orders of magnitude, marring the otherwise precise time-resolution capabilities of this class of instruments. The widespread notion that little dynamical information is available on timescales shorter than the timing uncertainty has led to various hardware schemes to reduce timing uncertainty. These schemes are expensive, tend to be specific to one experimental approach and cannot be used when the record was created under ill-defined or uncontrolled conditions such as during geological events. Here we present a data-analytical approach, based on singular-value decomposition and nonlinear Laplacian spectral analysis, that can recover the history and dynamics of a system from a dense collection of noisy snapshots spanning a sufficiently large multiple of the timing uncertainty. In this work, the power of the algorithm is demonstrated by extracting the underlying dynamics on the few-femtosecond timescale from noisy experimental X-ray free-electron laser data recorded with 300-femtosecond timing uncertainty. Using a noisy dataset from a pump-probe experiment on the Coulomb explosion of nitrogen molecules, our analysis reveals vibrational wave-packets consisting of components with periods as short as 15 femtoseconds, as well as more rapid changes, which have yet to be fully explored. Our approach can potentially be applied whenever dynamical or historical information is tainted by timing uncertainty.

47 OTHER INSTRUMENTATION↗

Real-time mixed reality display of dual particle radiation detector data

Radiation source localization and characterization are challenging tasks that currently require complex analyses for interpretation. Mixed reality (MR) technologies are at the verge of wide scale adoption and can assist in the visualization of complex data. Herein, we demonstrate real-time visualization of gamma ray and neutron radiation detector data in MR using the Microsoft HoloLens 2 smart glasses, significantly reducing user interpretation burden. Radiation imaging systems typically use double-scatter events of gamma rays or fast neutrons to reconstruct the incidence directional information, thus enabling source localization. The calculated images and estimated ’hot spots’ are then often displayed in 2D angular space projections on screens. By combining a state-of-the-art dual particle imaging system with HoloLens 2, we propose to display the data directly to the user via the head-mounted MR smart glasses, presenting the directional information as an overlay to the user’s 3D visual experience. We describe an open source implementation using efficient data transfer, image calculation, and 3D engine. We thereby demonstrate for the first time a real-time user experience to display fast neutron or gamma ray images from various radioactive sources set around the detector. We also introduce an alternative source search mode for situations of low event rates using a neural network and simulation based training data to provide a fast estimation of the source’s angular direction. Using MR for radiation detection provides a more intuitive perception of radioactivity and can be applied in routine radiation monitoring, education & training, emergency scenarios, or inspections.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Moment expansion of polarized dust SED: A new path towards capturing the CMB B -modes with LiteBIRD

Accurate characterization of the polarized dust emission from our Galaxy will be decisive in the quest for the cosmic microwave background (CMB) primordial B-modes. An incomplete modeling of its potentially complex spectral properties could lead to biases in the CMB polarization analyses and to a spurious measurement of the tensor-to-scalar ratio r. It is particularly crucial for future surveys like the LiteBIRD satellite, the goal of which is to constrain the faint primordial signal leftover by inflation with an accuracy on the tensor-to-scalar ratio r of the order of 10 –3 . Variations of the dust properties along and between lines of sight lead to unavoidable distortions of the spectral energy distribution (SED) that cannot be easily anticipated by standard component-separation methods. This issue can be tackled using a moment expansion of the dust SED, an innovative parametrization method imposing minimal assumptions on the sky complexity. In the present paper, we apply this formalism to the B-mode cross-angular power spectra computed from simulated LiteBIRD polarization data at frequencies between 100 and 402 GHz that contain CMB, dust, and instrumental noise. The spatial variation of the dust spectral parameters (spectral index β and temperature T) in our simulations lead to significant biases on r (~21 σ r ) if not properly taken into account. Performing the moment expansion in β, as in previous studies, reduces the bias but does not lead to sufficiently reliable estimates of r. We introduce, for the first time, the expansion of the cross-angular power spectra SED in both β and T, showing that, at the sensitivity of LiteBIRD, the SED complexity due to temperature variations needs to be taken into account in order to prevent analysis biases on r. Thanks to this expansion, and despite the existing correlations between some of the dust moments and the CMB signal responsible for a rise in the error on r, we can measure an unbiased value of the tensor-to-scalar ratio with a dispersion as low as σ r = 8.8 × 10 –4 .

79 ASTRONOMY AND ASTROPHYSICS↗

A control system of a negative hydrogen ion sources by using an EPICS-based proportional-integral-derivative

We have developed an EPICS-based control system for a multicusp negative ion source based on a VME IOC software, a sequencer controlling a closed proportional integral (PI) loop, and an interlock. The PI loop was tuned by a step input voltage, and tuning gains of the proportion and integral have been determined. The PI logics, developed by using standard proportional-integral-derivative records, can control the arc current within {+-}1% of a given set value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Portable x-ray fluorescence spectrometer for coating thickness measurement

A handheld x-ray spectrometer has been realized and tested. The purpose of the device is to measure the thickness of coated samples in the range of 1-1500 nm in an industrial environment. Accuracy of {approx}3% has been achieved in this range with a measurement time of 1 min. Automated software has been implemented to allow utilization by a nonspecialist operator. An automated calibration procedure, based on measurements of reference samples, is used.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precise measurement of the resolution in light microscopy using Fourier transform

The resolution power of light microscope has been accurately measured ({+-}5%) by Fourier transform of various object images and further evaluation of the highest spatial frequency in Fourier spectrum. Any unknown shape plane object with a shape feature's size smaller than the resolution to be measured was shown to provide a reliable resolution test. This simple method gives a direct measurement of the resolution power as defined by Abbe [Archiv. F. Mikroskopische Anat. 9, 413 (1873)]. The results have been justified by comparison to a standard resolution measurement by using calibrated periodic line patterns. Notably, the approach is applicable in super-resolution light microscopy (transmission, reflection, and fluorescence), where calibrated resolution targets do not occur. It was conveniently implemented by using a compact disk as a test object and free IMAGEJ imaging software.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗