Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CHART”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Temporal Summary Images: An Approach to Narrative Visualization via Interactive Annotation Generation and Placement

Visualization is a powerful technique for analysis and communication of complex, multidimensional, and time-varying data. However, it can be difficult to manually synthesize a coherent narrative in a chart or graph due to the quantity of visualized attributes, a variety of salient features, and the awareness required to interpret points of interest (POIs). We present Temporal Summary Images (TSIs) as an approach for both exploring this data and creating stories from it. As a visualization, a TSI is composed of three common components: (1) a temporal layout, (2) comic strip-style data snapshots, and (3) textual annotations. To augment user analysis and exploration, we have developed a number of interactive techniques that recommend relevant data features and design choices, including an automatic annotations workflow. As the analysis and visual design processes converge, the resultant image becomes appropriate for data storytelling. For validation, we use a prototype implementation for TSIs to conduct two case studies with large-scale, scientific simulation datasets.

97 MATHEMATICS AND COMPUTING↗

Factors associated with treatment limitations in two Swedish intensive care units: Prevalence and patient involvement

Abstract The aim was to study the prevalence, documentation, and patient involvement in treatment limitations (TLs) in two Swedish intensive care units (ICUs). All patients admitted to the ICUs of two Swedish regional hospitals in 2019 were screened for inclusion. Exclusion criteria included postanesthesia care <24 h. Patients were identified using the Swedish Intensive Care Registry (SIR) and data were extracted from SIR and hospital charts. Uni‐ and multivariable logistic analysis was performed to investigate associations with the presence of TLs. A total of 3090 patients were admitted to the two ICUs in 2019. After exclusion, 1019 patients were included in the study. 45.5% were women and the mean age was 62.9 years. 26.5% of the patients had one or several TLs. Age (OR 1.04 per one year increase 95% confidence interval (CI) 1.02–1.05), SAPS3‐score (OR 1.08 per one unit increase 95% CI 1.06–1.09) and ICU length of stay (OR 1.11 per one day increase 95% CI 1.05–1.17) were independently associated with an increased likelihood of receiving a TL. 17% of the patients were involved in the decision‐making process and in >30% of cases neither the patient nor next‐of‐kin were informed. Women were to a larger extent involved in the decision process than men (24.5 vs. 12.5% p < .05). When the intensivist documented why a TL was established, patient autonomy was four times more commonly stated as the motivation for the TL among women compared to men (15.5% vs. 3.8% p < .05). TLs were common in two Swedish ICUs but a substantial number of patients and next‐of‐kin were not involved in the decision‐making process or informed of the decision. Women were more often than men engaged in the decision to establish a TL.

Jönsson, Nino↗

An Analysis Platform for Multiscale Hydrogeologic Modeling with Emphasis on Hybrid Multiscale Methods

One of the most significant challenges facing hydrogeologic modelers is the disparity between those spatial and temporal scales at which fundamental flow, transport and reaction processes can best be understood and quantified (e.g., microscopic to pore scales, seconds to days) and those at which practical model predictions are needed (e.g., plume to aquifer scales, years to centuries). While the multiscale nature of hydrogeologic problems is widely recognized, technological limitations in computational and characterization restrict most practical modeling efforts to fairly coarse representations of heterogeneous properties and processes. For some modern problems, the necessary level of simplification is such that model parameters may lose physical meaning and model predictive ability is questionable for any conditions other than those to which the model was calibrated. Recently, there has been broad interest across a wide range of scientific and engineering disciplines in simulation approaches that more rigorously account for the multiscale nature of systems of interest. In this paper, we review a number of such approaches and propose a classification scheme for defining different types of multiscale simulation methods and those classes of problems to which they are most applicable. Our classification scheme is presented in terms of a flow chart (Multiscale Analysis Platform or MAP), and defines several different motifs of multiscale simulation. Within each motif, the member methods are reviewed and example applications are discussed. We focus attention on hybrid multiscale methods, in which two or more models with different physics described at fundamentally different scales are directly coupled within a single simulation. Very recently these methods have begun to be applied to groundwater flow and transport simulations, and we discuss these applications in the context of our classification scheme. As computational and characterization capabilities continue to improve, we envision that hybrid multiscale modeling will become more common and may become a viable alternative to conventional single-scale models in the near future.

Environmental Molecular Sciences Laboratory↗

Cyber-Physical System Implementation for Manufacturing With Analytics in the Cloud Layer

Effective and efficient modern manufacturing operations require the acceptance and incorporation of the fourth industrial revolution, also known as Industry 4.0. Traditional shop floors are evolving their production into smart factories. To continue this trend, a specific architecture for the cyber-physical system is required, as well as a systematic approach to automate the application of algorithms and transform the acquired data into useful information. This work makes use of an approach that distinguishes three layers that are part of the existing Industry 4.0 paradigm: edge, fog, and cloud. Each of the layers performs computational operations, transforming the data produced in the smart factory into useful information. Trained or untrained methods for data analytics can be incorporated into the architecture. A case study is presented in which a real-time statistical control process algorithm based on control charts was implemented. The algorithm automatically detects changes in the material being processed in a computerized numerical control (CNC) machine. The algorithm implemented in the proposed architecture yielded short response times. The performance was effective since it automatically adapted to the machining of aluminum and then detected when the material was switched to steel. The data were backed up in a database that would allow traceability to the line of g-code that performed the machining.

97 MATHEMATICS AND COMPUTING↗

Attributes of Bi-Directional Turbomachinery for Pumped Thermal Energy Storage

Abstract In this paper, we (i) present a methodology for determining the aerodynamic performance of bi-directional turbomachines for pumped thermal energy storage, i.e., turbomachines designed to operate as a compressor in one direction, and then as a turbine in the opposite direction, (ii) carry out performance computations for such turbomachines, and (iii) propose principles for conceptual design of these devices. Focus is placed on using the energy storage cycle not only to identify the novel requirements placed on bi-directional turbomachines but also to estimate the effect of these requirements on the efficiency of the energy storage process. In particular, the difference between aerodynamic loading in forward and in backward operation causes the blading to work at incidences leading to the performance below maximum efficiency, resulting in a lower round-trip efficiency. The description of the design principles includes determination of the number of stages, definition of nondimensional parameters for blading selection, and optimization of two-dimensional blading for bi-directional operation. The assessment of stage count shows the relationship between relative Mach number, pressure ratio, and round-trip efficiency. The nondimensional parameters are assessed through a bi-directional analogue to existing “Smith charts,” for the efficiency of single-direction turbomachines, as a function of camber and stagger. The blade shape evaluation and optimization show how the blade profile can be modified to address the requirements of a bi-directional turbomachine, enabling an increase in round-trip efficiency of two percentage points compared to a baseline double circular arc configuration.

Engineering↗

Simplified Formulas for External Pressure Design

Design of vessels for external pressure currently requires a chart-based solution or analytical approaches which are not necessarily intuitive. In this paper, we propose simple formulas for the external pressure evaluation of pipes and other cylindrical pressure vessels. We present a conceptual comparison between the elastic and elastic-plastic stability of structural columns and that of cylindrical vessels of long, intermediate, and short length. Their common features allow an accurate and straightforward approach for external pressure design. The approach is also extended to spherical caps, conical vessels, and formed heads.We compare the method presented to the current acceptance criteria from various design codes, including the ASME Boiler and Pressure Vessel Code Section VIII, Code Case 2286, and EN 13445-3, as well as codes for steel and aluminum structures. In further discussion, the simplified method is compared against the results of more than 500 experiments on the buckling of cylindrical and spherical vessels published over the past two centuries.This simple but accurate approximation is conceptually intuitive, analytically straightforward, and shows potential utility in pressure vessel design codes, as well as piping design codes such as B31 that currently reference ASME VIII for external pressure design.

Kirkland, Will↗

A recyclable self-healing composite with advanced sensing property

Polymer-based composites frequently encounter damage, often lurking beneath the surface and proving challenges to their early detection and repair. While material-based sensors show promise for encoding self-sensing properties within these composites, their in situ healing and reprocessability remain significant challenges. Therefore, the overarching goal of this study is the creation of a reprocessable polymeric composite encoded with self-healing attributes and the ability to autonomously sense damage. At the core of this innovation are vitrimers, a polymeric material characterized by a covalently adaptive dynamic network responsive to external factors such as heat. They combine thermoset-like resilience with thermoplastic-like flowability on demand under external stimuli. We nanoengineer a polyester-based vitrimeric polymer by incorporating piezoresistive carbon nanotubes (CNTs) as reinforcing elements that not only enhance its mechanical strength but also create a percolation network within the composite, thereby enabling piezoresistive self-sensing properties, all the while preserving the intrinsic self-healing capabilities offered by the vitrimeric matrix. The fabrication process of the composite involves a solvent-free in situ polymerization method that combines epoxy and anhydride-containing monomers with ~ 0.1 wt.% of CNTs. Once it was established that the introduction of CNTs into the polymeric matrix did not compromise the mechanical properties of the composite, their strain-sensing properties were characterized by applying cyclic loading while measuring their electrical resistance. Strikingly, CNT-enhanced vitrimer composite consistently retains its mechanical and sensing properties through repeated cycles of reshaping and reprocessing, underscoring its potential as a robust distributed strain sensor. This polyester-based vitrimeric composite is also easily recyclable without harsh chemical treatments. Preliminary findings from this study conclusively demonstrate that the bulk composite boasts both self-sensing capabilities and in situ detect healing properties, charting a promising course towards the development of a mechanically resilient multifunctional composite that seamlessly integrates selfsensing and healing capabilities.

Rohewal, Sargun Singh↗

Nuclear imaging of the breast: Translating achievements in instrumentation into clinical use

Approaches to imaging the breast with nuclear medicine and/or molecular imaging methods have been under investigation since the late 1980s when a technique called scintimammography was first introduced. This review charts the progress of nuclear imaging of the breast over the last 20 years, covering the development of newer techniques such as breast specific gamma imaging, molecular breast imaging, and positron emission mammography. Key issues critical to the adoption of these technologies in the clinical environment are discussed, including the current status of clinical studies, the efforts at reducing the radiation dose from procedures associated with these technologies, and the relevant radiopharmaceuticals that are available or under development. The necessary steps required to move these technologies from bench to bedside are also discussed.

60 APPLIED LIFE SCIENCES↗

SU-D-BRD-07: Automatic Patient Data Audit and Plan Quality Check to Support ARIA and Eclipse

Purpose: To ensure patient safety and treatment quality in RT departments that use Varian ARIA and Eclipse, we developed a computer software system and interface functions that allow previously developed electron chart checking (EcCk) methodologies to support these Varian systems. Methods: ARIA and Eclipse store most patient information in its MSSQL database. We studied the contents in the hundreds database tables and identified the data elements used for patient treatment management and treatment planning. Interface functions were developed in both c-sharp and MATLAB to support data access from ARIA and Eclipse servers using SQL queries. These functions and additional data processing functions allowed the existing rules and logics from EcCk to support ARIA and Eclipse. Dose and structure information are important for plan quality check, however they are not stored in the MSSQL database but as files in Varian private formats, and cannot be processed by external programs. We have therefore implemented a service program, which uses the DB Daemon and File Daemon services on ARIA server to automatically and seamlessly retrieve dose and structure data as DICOM files. This service was designed to 1) consistently monitor the data access requests from EcCk programs, 2) translate the requests for ARIA daemon services to obtain dose and structure DICOM files, and 3) monitor the process and return the obtained DICOM files back to EcCk programs for plan quality check purposes. Results: EcCk, which was previously designed to only support MOSAIQ TMS and Pinnacle TPS, can now support Varian ARIA and Eclipse. The new EcCk software has been tested and worked well in physics new start plan check, IMRT plan integrity and plan quality checks. Conclusion: Methods and computer programs have been implemented to allow EcCk to support Varian ARIA and Eclipse systems. This project was supported by a research grant from Varian Medical System.

60 APPLIED LIFE SCIENCES↗

SU-E-E-02: Dashboard for Tracking Physics Resident Progress

Purpose: Design a system to easily and securely track the progress of medical physics residents through their residency. Paper sign-offs while offering a real signature are not easily updated or summarized. A resident or mentor needs to be able to quickly assess what the current assignments are, what are overdue, and whether the resident is on track to complete all the tasks in a timely fashion. An electronic version can accomplish all these goals. Methods: An electronic dashboard was created in excel to not only house the tasks and sign-off but to succinctly summarize the residents progress. The first tab contains the dashboard which displays tables of the progress of the residents in each rotation, their current task, and overdue tasks. It also displays the last meetings with the residents, and timeline of important items, and a burn-down chart of the remaining tasks. This are all tied to the data and current date which auto fills the tables. The second tab contains the data. This is comprised of lists of rotations and their associated tasks along with their due dates. A signature column was also created which is password protected but allows special subset users i.e. mentors to alter without using a password. Results: The dashboard has allowed residents to better track their progress and tells them what they should be working on. It has also allowed the mentors and the program director to rapid assess their progress. Conclusion: The dashboard is successful and has been created to allow easy addition and subtraction of required tasks as the residency evolves. The next step is to create a web app version of the excel sheet with logins.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-P-03: Implementing a Low Dose Lung Screening CT Program Meeting Regulatory Requirements

Purpose: To provide information pertaining to IROC Houston QA Center's (RPC) credentialing process for institutions participating in NCI-sponsored clinical trials. Purpose: Provide guidance to the Radiology Departments with the intent of implementing a Low Dose CT Screening Program using different CT Scanners with multiple techniques within the framework of the required state regulations. Method: State Requirements for the purpose of implementing a Low Dose CT Lung Protocol required working with the Radiology and Pulmonary Department in setting up a Low Dose Screening Protocol designed to reduce the radiation burden to the patients enrolled. Radiation dose measurements (CTDIvol) for various CT manufacturers (Siemens16, Siemens 64, Philips 64, and Neusoft128) for three different weight based protocols. All scans were reviewed by the Radiologist. Prior to starting a low dose lung screening protocol, information had to be submitted to the state for approval. Performing a Healing Arts protocol requires extensive information. This not only includes name and address of the applicant but a detailed description of the disease, the x-ray examination and the population to be examined. The unit had to be tested by a qualified expert using the technique charts. The credentials of all the operators, the supervisors and the Radiologists had to be submitted to the state. Results: All the appropriate documentation was sent to the state for review. The measured results between the Low Dose Protocol versus the default Adult Chest Protocol showed that there was a dose reduction of 65% for small (100-150 lb.) patient, 75% for the Medium patient (151-250 lbs.), and a 55% reduction for the Large patient ( over 250 lbs.). Conclusion: Measured results indicated that the Low Dose Protocol indeed lowered the screening patient's radiation dose and the institution was able to submit the protocol to the State's regulators.

60 APPLIED LIFE SCIENCES↗

SU-E-T-51: Bayesian Network Models for Radiotherapy Error Detection

Purpose: To develop a probabilistic model of radiotherapy plans using Bayesian networks that will detect potential errors in radiation delivery. Methods: Semi-structured interviews with medical physicists and other domain experts were employed to generate a set of layered nodes and arcs forming a Bayesian Network (BN) which encapsulates relevant radiotherapy concepts and their associated interdependencies. Concepts in the final network were limited to those whose parameters are represented in the institutional database at a level significant enough to develop mathematical distributions. The concept-relation knowledge base was constructed using the Web Ontology Language (OWL) and translated into Hugin Expert Bayes Network files via the the RHugin package in the R statistical programming language. A subset of de-identified data derived from a Mosaiq relational database representing 1937 unique prescription cases was processed and pre-screened for errors and then used by the Hugin implementation of the Estimation-Maximization (EM) algorithm for machine learning all parameter distributions. Individual networks were generated for each of several commonly treated anatomic regions identified by ICD-9 neoplasm categories including lung, brain, lymphoma, and female breast. Results: The resulting Bayesian networks represent a large part of the probabilistic knowledge inherent in treatment planning. By populating the networks entirely with data captured from a clinical oncology information management system over the course of several years of normal practice, we were able to create accurate probability tables with no additional time spent by experts or clinicians. These probabilistic descriptions of the treatment planning allow one to check if a treatment plan is within the normal scope of practice, given some initial set of clinical evidence and thereby detect for potential outliers to be flagged for further investigation. Conclusion: The networks developed here support the use of probabilistic models into clinical chart checking for improved detection of potential errors in RT plans.

60 APPLIED LIFE SCIENCES↗

SU-E-T-310: Targeting Safety Improvements Through Analysis of Near-Miss Error Detection Points in An Incident Learning Database

Purpose: Radiation treatment planning involves a complex workflow that can make safety improvement efforts challenging. This study utilizes an incident reporting system to identify detection points of near-miss errors, in order to guide our departmental safety improvement efforts. Previous studies have examined where errors arise, but not where they are detected or their patterns. Methods: 1377 incidents were analyzed from a departmental nearmiss error reporting system from 3/2012–10/2013. All incidents were prospectively reviewed weekly by a multi-disciplinary team, and assigned a near-miss severity score ranging from 0–4 reflecting potential harm (no harm to critical). A 98-step consensus workflow was used to determine origination and detection points of near-miss errors, categorized into 7 major steps (patient assessment/orders, simulation, contouring/treatment planning, pre-treatment plan checks, therapist/on-treatment review, post-treatment checks, and equipment issues). Categories were compared using ANOVA. Results: In the 7-step workflow, 23% of near-miss errors were detected within the same step in the workflow, while an additional 37% were detected by the next step in the workflow, and 23% were detected two steps downstream. Errors detected further from origination were more severe (p<.001; Figure 1). The most common source of near-miss errors was treatment planning/contouring, with 476 near misses (35%). Of those 476, only 72(15%) were found before leaving treatment planning, 213(45%) were found at physics plan checks, and 191(40%) were caught at the therapist pre-treatment chart review or on portal imaging. Errors that passed through physics plan checks and were detected by therapists were more severe than other errors originating in contouring/treatment planning (1.81 vs 1.33, p<0.001). Conclusion: Errors caught by radiation treatment therapists tend to be more severe than errors caught earlier in the workflow, highlighting the importance of safety checks in dosimetry and physics. We are utilizing our findings to improve manual and automated checklists for dosimetry and physics.

60 APPLIED LIFE SCIENCES↗

SU-E-T-473: A Patient-Specific QC Paradigm Based On Trajectory Log Files and DICOM Plan Files

Purpose: To evaluate a remote QC tool for monitoring treatment machine parameters and treatment workflow. Methods: The Varian TrueBeamTM linear accelerator is a digital machine that records machine axis parameters and MLC leaf positions as a function of delivered monitor unit or control point. This information is saved to a binary trajectory log file for every treatment or imaging field in the patient treatment session. A MATLAB analysis routine was developed to parse the trajectory log files for a given patient, compare the expected versus actual machine and MLC positions as well as perform a cross-comparison with the DICOM-RT plan file exported from the treatment planning system. The parsing routine sorts the trajectory log files based on the time and date stamp and generates a sequential report file listing treatment parameters and provides a match relative to the DICOM-RT plan file. Results: The trajectory log parsing-routine was compared against a standard record and verify listing for patients undergoing initial IMRT dosimetry verification and weekly and final chart QC. The complete treatment course was independently verified for 10 patients of varying treatment site and a total of 1267 treatment fields were evaluated including pre-treatment imaging fields where applicable. In the context of IMRT plan verification, eight prostate SBRT plans with 4-arcs per plan were evaluated based on expected versus actual machine axis parameters. The average value for the maximum RMS MLC error was 0.067±0.001mm and 0.066±0.002mm for leaf bank A and B respectively. Conclusion: A real-time QC analysis program was tested using trajectory log files and DICOM-RT plan files. The parsing routine is efficient and able to evaluate all relevant machine axis parameters during a patient treatment course including MLC leaf positions and table positions at time of image acquisition and during treatment.

60 APPLIED LIFE SCIENCES↗

MO-E-18C-05: Global Health Catalyst: A Novel Platform for Enhancing Access to Medical Physics Education and Research Excellence (AMPERE)

Purpose: To develop a platform for catalyzing collaborative global Cancer Care Education and Research (CaRE), with a prime focus on enhancing Access to Medical Physics Education and Research Excellence (AMPERE) Methods: An analysis of over 50 global health collaborations between partners in the U.S. and low and middle income countries (LMIC) in Africa was carried out to assess the models of collaborations in Education and Research and relative success. A survey was carried out with questions including: the nature of the collaboration, how it was initiated, impact of culture and other factors, and recommendations for catalyzing/enhancing such collaborations. An online platform called Global Health Catalyst was developed for enhancing AMPERE. Results: The analysis yielded three main models for global health collaborations with survey providing key recommendations on how to enhance such collaborations. Based on this, the platform was developed, and customized to allow Medical Physicists and other Radiation oncology (RadOnc) professionals interested in participating in Global health to readily do so e.g. teach an online course module, participate in training Medical Physicists or other RadOnc health professionals in LMIC, co-mentor students, residents or postdocs, etc. The growing list of features on the platform also include: a feature to enable people to easily find each other, form teams, operate more effectively as partners from different disciplines, institutions, nations and cultural backgrounds, share tools and technologies, obtain seed funding to develop curricula and/or embark upon new areas of investigation, and participate in humanitarian outreach: remote treatment planning assistance, and participation in virtual Chart Rounds, etc. Conclusion: The developed Global Health Catalyst platform could enable any Medical Physicist or RadoOnc professional interested in global health to readily participate in the Education/training of next generation RadOnc professionals and global health leaders, and enhance AMPERE, especially for LMIC.

60 APPLIED LIFE SCIENCES↗

MO-G-BRE-04: Automatic Verification of Daily Treatment Deliveries and Generation of Daily Treatment Reports for a MR Image-Guided Treatment Machine

Purpose: Two aims of this work were to develop a method to automatically verify treatment delivery accuracy immediately after patient treatment and to develop a comprehensive daily treatment report to provide all required information for daily MR-IGRT review. Methods: After systematically analyzing the requirements for treatment delivery verification and understanding the available information from a novel MR-IGRT treatment machine, we designed a method to use 1) treatment plan files, 2) delivery log files, and 3) dosimetric calibration information to verify the accuracy and completeness of daily treatment deliveries. The method verifies the correctness of delivered treatment plans and beams, beam segments, and for each segment, the beam-on time and MLC leaf positions. Composite primary fluence maps are calculated from the MLC leaf positions and the beam-on time. Error statistics are calculated on the fluence difference maps between the plan and the delivery. We also designed the daily treatment delivery report by including all required information for MR-IGRT and physics weekly review - the plan and treatment fraction information, dose verification information, daily patient setup screen captures, and the treatment delivery verification results. Results: The parameters in the log files (e.g. MLC positions) were independently verified and deemed accurate and trustable. A computer program was developed to implement the automatic delivery verification and daily report generation. The program was tested and clinically commissioned with sufficient IMRT and 3D treatment delivery data. The final version has been integrated into a commercial MR-IGRT treatment delivery system. Conclusion: A method was developed to automatically verify MR-IGRT treatment deliveries and generate daily treatment reports. Already in clinical use since December 2013, the system is able to facilitate delivery error detection, and expedite physician daily IGRT review and physicist weekly chart review.

60 APPLIED LIFE SCIENCES↗

SU-D-BRD-05: Online Framework for Plan Tracking and Automatic Checks in Radiation Therapy

Purpose: To develop an online framework that tracks a patient’s plan from initial simulation to treatment and that helps automate elements of the physics plan checks usually performed in the record and verify (RV) system and treatment planning system. Methods: We have developed PlanTracker, an online plan tracking system that automatically imports new patients tasks and follows it through treatment planning, physics checks, therapy check, and chart rounds. A survey was designed to collect information about the amount of time spent by medical physicists in non-physics related tasks. We then assessed these non-physics tasks for automation. Using these surveys, we directed our PlanTracker software development towards the automation of intra-plan physics review. We then conducted a systematic evaluation of PlanTracker’s accuracy by generating test plans in the RV system software designed to mimic real plans, in order to test its efficacy in catching errors both real and theoretical. Results: PlanTracker has proven to be an effective improvement to the clinical workflow in a radiotherapy clinic. We present data indicating that roughly 1/3 of the physics plan check can be automated, and the workflow optimized, and show the functionality of PlanTracker. When the full system is in clinical use we will present data on improvement of time use in comparison to survey data prior to PlanTracker implementation. Conclusion: We have developed a framework for plan tracking and automatic checks in radiation therapy. We anticipate using PlanTracker as a basis for further development in clinical/research software. We hope that by eliminating the most simple and time consuming checks, medical physicists may be able to spend their time on plan quality and other physics tasks rather than in arithmetic and logic checks. We see this development as part of a broader initiative to advance the clinical/research informatics infrastructure surrounding the radiotherapy clinic. This research project has been financially supported by Varian Medical Systems, Palo Alto, CA, through a Varian MRA.

60 APPLIED LIFE SCIENCES↗

SU-D-BRD-07: Evaluation of the Effectiveness of Statistical Process Control Methods to Detect Systematic Errors For Routine Electron Energy Verification

Purpose: To evaluate the ability of statistical process control methods to detect systematic errors when using a two dimensional (2D) detector array for routine electron beam energy verification. Methods: Electron beam energy constancy was measured using an aluminum wedge and a 2D diode array on four linear accelerators. Process control limits were established. Measurements were recorded in control charts and compared with both calculated process control limits and TG-142 recommended specification limits. The data was tested for normality, process capability and process acceptability. Additional measurements were recorded while systematic errors were intentionally introduced. Systematic errors included shifts in the alignment of the wedge, incorrect orientation of the wedge, and incorrect array calibration. Results: Control limits calculated for each beam were smaller than the recommended specification limits. Process capability and process acceptability ratios were greater than one in all cases. All data was normally distributed. Shifts in the alignment of the wedge were most apparent for low energies. The smallest shift (0.5 mm) was detectable using process control limits in some cases, while the largest shift (2 mm) was detectable using specification limits in only one case. The wedge orientation tested did not affect the measurements as this did not affect the thickness of aluminum over the detectors of interest. Array calibration dependence varied with energy and selected array calibration. 6 MeV was the least sensitive to array calibration selection while 16 MeV was the most sensitive. Conclusion: Statistical process control methods demonstrated that the data distribution was normally distributed, the process was capable of meeting specifications, and that the process was centered within the specification limits. Though not all systematic errors were distinguishable from random errors, process control limits increased the ability to detect systematic errors using routine measurement of electron beam energy constancy.

07 ISOTOPE AND RADIATION SOURCES↗