Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CAMERA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

A room-temperature polarization-sensitive CMOS terahertz camera based on quantum-dot-enhanced terahertz-to-visible photon upconversion

Detection of terahertz (THz) radiation has many potential applications, but presently available detectors are limited in many aspects of their performance, including sensitivity, speed, bandwidth and operating temperature. Most do not allow the characterization of THz polarization states. Recent observation of THz-driven luminescence in quantum dots offers a possible detection mechanism via field-driven interdot charge transfer. Here, we demonstrate a room-temperature complementary metal–oxide–semiconductor THz camera and polarimeter based on quantum-dot-enhanced THz-to-visible upconversion mechanism with optimized luminophore geometries and fabrication designs. Besides broadband and fast responses, the nanoslit-based sensor can detect THz pulses with peak fields as low as 10 kV cm–1. A related coaxial nanoaperture-type device shows a to-date-unexplored capability to simultaneously record the THz polarization state and field strength with similar sensitivity.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Large field-of-view event-mode camera for high-precision epithermal neutron resonance imaging

A large-area event-mode camera system coupled with a 6 LiF-ZnS:Ag scintillator is applied for neutron resonance imaging (NRI) on the energy-resolved neutron imaging (ERNI) flight path, also known as Flight Path 5 (FP5), at the Los Alamos Neutron Science Center (LANSCE). This novel neutron imaging system, featuring a 120 x 120 mm 2 field of view, efficiently captures resonance information across the entire image in a single acquisition, significantly reducing beam time requirements compared to conventional energy-resolved neutron imaging systems. High-quality neutron radiographs with enhanced spatial resolution are achieved through the reconstruction of neutron events based on observations of individual photons emitted from the scintillator. The system demonstrates reduced background through neutron/gamma discrimination capabilities while maintaining sharpness across a large fields of view. In the measurements presented here, a spatial resolution of approximately 340 μm was achieved using center-of-gravity photon cluster centroiding. We demonstrate the system’s capability for quantitatively determining isotopic distributions in various thin samples, as well as automatically reconstructing complex scenes with overlapping resonances from diverse samples. These results are obtained using standard data analysis tools, despite the relatively slow 6 LiF-ZnS:Ag scintillator, which may not be optimal for absorption resonance detection. The capabilities demonstrated here offer a valuable, versatile, and cost-effective solution for high spatial and temporal resolution, large field-of-view energy-resolved neutron imaging, with potential applications across various scientific and industrial domains.

36 MATERIALS SCIENCE↗

Energy-resolved neutron imaging and diffraction including grain orientation mapping using event camera technology

Time-of-flight neutron diffraction and energy-resolved imaging each provide unique perspectives into material properties. Neutron diffraction is useful for assessing microstructural parameters such as phase composition, texture, and dislocation densities, though it typically provides averaged data over the sampled volume. Energy-resolved imaging, on the other hand, offers both spatial and spectral information by detecting Bragg edges and neutron absorption resonances, which enables detailed mapping of microstructure and isotopic composition. When combined, these techniques have the potential to enrich our understanding of material behavior across different scales, enhancing our understanding of complex materials. Traditionally, these modalities are conducted on separate instruments, which is time-consuming and poses challenges for data integration. Here, we report the integration of the LumaCam, an event-mode energy-resolved neutron imaging camera with the HIPPO time-of-flight diffractometer at LANSCE. This integration enables simultaneous diffraction and imaging across the full spectrum, with analysis optimized for diffraction and Bragg-edge imaging in the thermal range (0.45–10 Å) and resonance imaging in the epithermal range (0.5–3000 eV), facilitating comprehensive multi-modal analysis. We demonstrate its capabilities through case studies, including spatial mapping of grain orientations in a steel sample and accurate thickness estimations for irregular samples including a depleted uranium cylinder and a natural silver-containing mineral specimen. The combined setup enhances real-time sample alignment and provides comprehensive data for crystal structure, texture, and isotopic composition analysis. This approach opens new possibilities for advanced applications in nuclear engineering, archaeology, and materials science.

36 MATERIALS SCIENCE↗

Gated pinhole camera imaging of the high-energy ions emitted by a discharge produced Sn plasma for extreme ultraviolet generation

The origin and nature of the high-energy ions emitted by a discharge produced plasma source are studied using gated pinhole camera imaging. Time-of-flight analysis in combination with Faraday cup measurements enables characterization of the high-velocity component of the ionic debris. The use of an optional magnetic field allows mass-to-charge analysis of the first part of the Faraday cup signal. It is shown that this consists mainly of oxygen ions emitted from a region near the cathode. Time-resolved images of Sn ions with a kinetic energy of 45 keV visualize the regions in between the electrodes where the high-energy ion generation takes place.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of Large Grain Nb Ingot Microstructure Using EBSP Mapping and Laue Camera Methods

Large grain/single crystal Nb is currently being examined for fabricating superconducting radiofrequency (SRF) cavities as an alternative to using rolled sheet. Three ingot slices from different suppliers have been characterized and are compared. It is desirable to know the grain orientations of an ingot slice before fabrication. Characterization of an ingot slice has been done using electron backscattered pattern (EBSP) orientation imaging microscopy (OIM), which requires cutting out pieces from the slice, a destructive technique. Use of a Laue camera allows nondestructive characterization of grain orientations. The OIM method was used to examine ingot slices from CBMM and Ningxia, while the Laue method was used to examine a Heraeus ingot slice. The three ingot slices are compared in terms of their crystal orientations and grain boundary misorientations, indicating no obvious commonalities. The Laue method has practical advantages over OIM for evaluating ingot slices during the manufacturing process.

36 MATERIALS SCIENCE↗

Novel energy resolving x-ray pinhole camera on Alcator C-Mod

A new energy resolving x-ray pinhole camera has been recently installed on Alcator C-Mod. This diagnostic is capable of 1D or 2D imaging with a spatial resolution of Almost-Equal-To 1 cm, an energy resolution of Almost-Equal-To 1 keV in the range of 3.5-15 keV and a maximum time resolution of 5 ms. A novel use of a Pilatus 2 hybrid-pixel x-ray detector [P. Kraft et al., J. Synchrotron Rad. 16, 368 (2009)] is employed in which the lower energy threshold of individual pixels is adjusted, allowing regions of a single detector to be sensitive to different x-ray energy ranges. Development of this new detector calibration technique was done as a collaboration between PPPL and Dectris Ltd. The calibration procedure is described, and the energy resolution of the detector is characterized. Initial data from this installation on Alcator C-Mod is presented. This diagnostic provides line-integrated measurements of impurity emission which can be used to determine impurity concentrations as well as the electron energy distribution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absolute calibration of a charge-coupled device camera with twin beams

We report on the absolute calibration of a Charge-Coupled Device (CCD) camera by exploiting quantum correlation. This method exploits a certain number of spatial pairwise quantum correlated modes produced by spontaneous parametric-down-conversion. We develop a measurement model accounting for all the uncertainty contributions, and we reach the relative uncertainty of 0.3% in low photon flux regime. This represents a significant step forward for the characterization of (scientific) CCDs used in mesoscopic light regime.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Invited Article: Quantitative imaging of explosions with high-speed cameras

Here, the techniques presented in this paper allow for mapping of temperature, pressure, chemical species, and energy deposition during and following detonations of explosives, using high speed cameras as the main diagnostic tool. Additionally, this work provides measurement in the explosive near to far-field (0-500 charge diameters) of surface temperatures, peak air-shock pressures, some chemical species signatures, shock energy deposition, and air shock formation.

47 OTHER INSTRUMENTATION↗

Multi-energy SXR cameras for magnetically confined fusion plasmas (invited)

A compact multi-energy soft x-ray camera has been developed for time, energy and space-resolved measurements of the soft-x-ray emissivity in magnetically confined fusion plasmas. Multi-energy soft x-ray imaging provides a unique opportunity for measuring, simultaneously, a variety of important plasma properties (T e , n Z , ΔZ eff , and n e,fast ). The electron temperature can be obtained by modeling the slope of the continuum radiation from ratios of the available brightness and inverted radial emissivity profiles over multiple energy ranges. Impurity density measurements are also possible using the line-emission from medium- to high-Z impurities to separate the background as well as transient levels of metal contributions. As a result, this technique should be explored also as a burning plasma diagnostic in-view of its simplicity and robustness.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Alignment, orientation, and Coulomb explosion of difluoroiodobenzene studied with the pixel imaging mass spectrometry (PImMS) camera

Laser-induced adiabatic alignment and mixed-field orientation of 2,6-difluoroiodobenzene (C 6 H 3 F 2 I) molecules are probed by Coulomb explosion imaging following either near-infrared strong-field ionization or extreme-ultraviolet multi-photon inner-shell ionization using free-electron laser pulses. The resulting photoelectrons and fragment ions are captured by a double-sided velocity map imaging spectrometer and projected onto two position-sensitive detectors. The ion side of the spectrometer is equipped with a pixel imaging mass spectrometry camera, a time-stamping pixelated detector that can record the hit positions and arrival times of up to four ions per pixel per acquisition cycle. Thus, the time-of-flight trace and ion momentum distributions for all fragments can be recorded simultaneously. Finally, we show that we can obtain a high degree of one-and three-dimensional alignment and mixed-field orientation and compare the Coulomb explosion process induced at both wavelengths

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The neutron camera upgrade for MAST Upgrade

The Neutron Camera Upgrade (NCU) is a neutron flux monitor consisting of six lines of sight (LoSs) under installation on Mega Ampere Spherical Tokamak (MAST) Upgrade. The NCU is expected to contribute to the study of the confinement of fast ions and on the efficiency of non-inductive current drive in the presence of on-axis and off-axis neutral beam injection by measuring the neutron emissivity profile along the equatorial plane. This paper discusses the NCU main design criteria, the engineering and interfacing issues, and the solutions adopted. In addition, the results from the characterization and performance studies of the neutron detectors using standard γ-rays sources and a 252 Cf source are discussed. The proposed design has a time resolution of 1 ms with a statistical uncertainty of less than 10% for all MAST Upgrade scenarios with a spatial resolution of 10 cm: higher spatial resolution is possible by moving the LoSs in-between plasma discharges. Finally, the energy resolution of the neutron detector is better than 10% for a light output of 0.8 MeVee, and the measured pulse shape discrimination is satisfactory.

47 OTHER INSTRUMENTATION↗

Implementing time resolved electron temperature capability at the NIF using a streak camera

A new capability on NIF has been implemented to measure the temperature of x-ray emitting sources. Although it is designed primarily for Inertial Confinement Fusion (ICF), it can be used for any hot emitting source that is well modeled. The electron temperature (T e ) of the hot spot within the core of imploded inertial confinement fusion capsules is an effective indicator of implosion performance. Currently, there are spatially and temporally integrated T e inferences using image plates. A temporally resolved measurement of Te will help elucidate the mechanisms for hot spot heating and cooling such as conduction to fuel, alpha-heating, mix and radiative losses. To determine the temporally resolved T e of hot spots, specific filters are added to an existing x-ray streak camera “Streaked Polar Instrumentation for Diagnosing Energetic Radiation (SPIDER)” to probe the emission spectrum during the x-ray burn history of implosions on the National Ignition Facility (NIF). One of the difficulties in inferring the hot spot temperature is the attenuation of the emission due to opacity from the shell and fuel. Therefore, a series of increasingly thick titanium filters were implemented to isolate the emission in specific energy regions that are sensitive to temperatures above 3keV while not significantly influenced by the shell/fuel attenuation. Additionally, a relatively thin zinc filter was used to measure the contribution of colder emission sources. Since the signal levels of the emission through the thicker filters are relatively poor, a dual slit (aperture) was designed to increase detected signal at the higher end of the spectrum. Herein, the design of the filters and slit are described, an overview of the solving technique is provided, and initial electron temperature results are reported.

47 OTHER INSTRUMENTATION↗

Extension of the neutron scatter camera sensitivity to the ~10–200 MeV neutron energy range

The Neutron Scatter Camera (NSC) is a neutron spectrometer and imager that has been developed and improved by the Sandia National Laboratories for several years. Built for special nuclear material searches, the instrument was configured by the design to reconstruct neutron sources within the fission energy range 1–10 MeV. In this work, we present modifications that attempt to extend the NSC sensitivity to neutron energies in the range ~10–200 MeV and discuss the corresponding consequences for the event processing. We present simulation results that manifest important aspects of the NSC response to those intermediate energy neutrons. The simulation results also evidence that the instrument’s spectroscopic capabilities severely deteriorate at those energies, mainly due to the uncertainties in measuring energy, time, and distance between the two neutron scattering interactions. Furthermore, this work is motivated by the need to characterize neutron fluxes at particle accelerators as they may represent important backgrounds for neutrino experiments.

47 OTHER INSTRUMENTATION↗

Effect of reflections on 2D tomographic reconstructions of filtered cameras and on interpreting spectroscopic measurements in the JET ITER-like wall divertor

Considering reflections from metallic wall surfaces in generation of tomographic reconstructions of the tangentially viewing, visible-range spectroscopic divertor cameras in JET has been observed to yield enhanced spatial accuracy and significant reduction of emission artifacts in experimentally resolved 2D line emission distributions. Neglection of reflections in the tomography process was found to lead to overestimation of the emission near the wall surfaces by up to a factor of 4, as well as to formation of bright emission artifacts between the main emission regions and the wall surfaces, comprising locally up to 50% of the emission. Mimicking divertor spectroscopy measurements by integrating the tomographic reconstructions along vertical lines-of-sight implies that reflections comprise 15%–25% of the observed line-integrated emission peaks. Additionally, the spatial differences in the reflection contribution between the different lines-of-sight are less pronounced than in the 2D reconstructions due to the dominance of the brightest emission regions through which the spectroscopic lines-of-sight pass. However, postprocessing EDGE2D-EIRENE simulations using the CHERAB code and synthetic spectroscopy suggests a decrease of the spectroscopically inferred divertor electron temperature by up to 75%, when redistribution of the observed light due to reflections is considered.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Inferred UV fluence focal-spot profiles from soft x-ray pinhole-camera measurements on OMEGA

A method was developed with laser-irradiated Au planar foils to characterize the focal spot of UV laser beams on target at full energy from soft x-ray emission. A pinhole camera with a back-thinned charge-coupled–device detector and filtration with thin Be and Al foil filters provides images of the x-ray emission at photon energies <2 keV. This method requires a careful measurement of the relation between the applied UV fluence and the x-ray signal, which can be described by a power-law dependence. The measured exponent γ ~ 2 provides a dynamic range of ~25 for the inferred UV fluence. UV fluence profiles of selected beams were measured for 100-ps and 1-ns laser pulses and were compared to directly measured profiles from an UV equivalent-target-plane diagnostic. The inferred spot size and super-Gaussian order from the x-ray technique agree within several percent with the values measured with the direct UV measurements.

47 OTHER INSTRUMENTATION↗

Continuous-wave planar laser induced fluorescence with a fast camera

We present planar, laser induced fluorescence (PLIF) measurements of the velocity-resolved distribution function of ions in a plasma using a modulated, narrow linewidth, continuous-wave laser. Plasma emission is acquired with a high frame rate camera, and the laser light is spread into a thin sheet so that an entire plane of the plasma is imaged at each interrogation wavelength. Fourier analysis is conducted on each pixel of the images to separate the modulated fluorescent emission from the background light. Argon ion temperatures and bulk flow maps are reported in a helicon plasma source, and standard single-point LIF measurements provide validation of the PLIF measurement.

47 OTHER INSTRUMENTATION↗

Multi-energy reconstructions, central electron temperature measurements, and early detection of the birth and growth of runaway electrons using a versatile soft x-ray pinhole camera at MST

A multi-energy soft x-ray pinhole camera has been designed, built, and deployed at the Madison Symmetric Torus to aid the study of particle and thermal transport, as well as MHD stability physics. This novel imaging diagnostic technique employs a pixelated x-ray detector in which the lower energy threshold for photon detection can be adjusted independently on each pixel. The detector of choice is a PILATUS3 100 K with a 450 μm thick silicon sensor and nearly 100 000 pixels sensitive to photon energies between 1.6 and 30 keV. An ensemble of cubic spline smoothing functions has been applied to the line-integrated data for each time-frame and energy-range, obtaining a reduced standard-deviation when compared to that dominated by photon-noise. The multi-energy local emissivity profiles are obtained from a 1D matrix-based Abel-inversion procedure. Central values of Te can be obtained by modeling the slope of the continuum radiation from ratios of the inverted radial emissivity profiles over multiple energy ranges with no a priori assumptions of plasma profiles, magnetic field reconstruction constraints, high-density limitations, or need of shot-to-shot reproducibility. In tokamak plasmas, a novel application has recently been tested for early detection, 1D imaging, and study of the birth, exponential growth, and saturation of runaway electrons at energies comparable to 100 × Te,0; thus, early results are also presented.

Delgado-Aparicio, L. F. (ORCID:0000000167394380)↗

Beam-pointing verification using x-ray pinhole cameras on the 60-beam OMEGA laser

On the OMEGA laser system, the beam-pointing accuracy is verified by irradiating a 4 mm diameter Au-coated spherical target with ~23 kJ of laser energy. Up to ten x-ray pinhole cameras record the x-ray emission from all 60-beam spots. A new set of algorithms has been developed to improve the accuracy of the pointing evaluation. An updated edge-finding procedure allows one to infer the center of the sphere with subpixel accuracy. A new approach was introduced to back-propagate the pixel locations on the 2D image to the 3D surface of the sphere. Furthermore, a fast Fourier transform-based de-noising method significantly improves the signal-to-noise of the data. Based on the beam-pointing analysis, hard-sphere calculations of the laser-drive illumination uniformity on the target surface and the decomposition of the illumination distribution into lower order modes (1–10) are evaluated.

47 OTHER INSTRUMENTATION↗