Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Battery Storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Design of Energy Storage Friendly Regulation Signals using Empirical Mode Decomposition

This paper presents an energy storage friendly regulation signal design method based on empirical mode decomposition (EMD). Battery energy storage systems (BESS) have a very fast response rate and excellent ramping capability, making them ideal resources for providing fast regulation services. However, the limitation in energy storage capacity prevents the BESS from following non-energy neutral signals for prolonged durations. The existing BESS-friendly regulation signal design uses the filter-based approach, which cannot guarantee the resultant fast changing signals are energy neutral. The EMD-based approach decomposes the raw regulation signal into an energy-neutral, fast-changing component and a slow-changing component. The fast and slow regulation signals obtained using the proposed method are compared with the PJM RegD and RegA signals. Simulation results and cost-benefit analysis demonstrate that both generators and BESSs have achieved better performance in terms of revenue, response rate, and lifetime when responding to the EMD-based regulation signals compared with the filter-based RegA and RegD signals.

Meng, Yao↗

Platform Li-Ion Battery Risk Assessment Tool (CRADA Final Report)

Creare was awarded a Phase 1 STTR contract from the US Office of Naval Research, with a seven month period of performance from 6/28/2010 to 1/28/2011. The objectives of the STTR were to determine the feasibility of developing a software package for estimating reliability of battery packs, and develop a user interface to allow the designer to assess the overall impact on battery packs and host platforms for cell-level faults. NREL served as sub-tier partner to Creare, providing battery modeling and battery thermal safety expertise.

25 ENERGY STORAGE↗

Study of Storage Requirements and Costs for Shaping Renewables and Nuclear Energy (FY23 Summary Report)

To decarbonize electricity generation primarily by using wind and solar resources, it is likely that additional low (or zero) carbon dioxide (CO 2 ) alternatives will be required for ensuring a reliable electricity supply. This study extends the work and modeling framework that we consolidated in FY 2022, by assessing the zero-CO 2 pathways of a Texas power system in which the availability of variable renewable energy (VRE), nuclear energy, and energy storage types (i.e., battery and thermal energy storage [TES]) are considered the sole resources available for expansion. Using the Risk Analysis Virtual Environment (RAVEN) and Holistic Energy Resource Optimization Network (HERON) frameworks, this study investigates the market of two nuclear energy technologies (i.e., large light-water reactors [LWRs] and LWR-type small modular reactors [SMRs]) under two plausible storage coupling scenarios (i.e., electric coupling and direct thermal coupling). We also explore optimal environments for nuclear energy deployment, and identify key performance characteristics that make nuclear energy economically viable in areas with significant intermittent energy sources. Our analysis encompasses 24 cases. We model the least-cost grid systems, highlight the potential for a coupled LWR-TES approach, and utilize SMRs to achieve deep decarbonization in an affordable, technically feasible manner. We also examine seasonal variations in balancing electricity supply and demand, and account for varying performance, costs, and grid constraints. Overall, the findings of our modeling afford valuable insights for supporting future technology investment decisions in the energy sector.

25 ENERGY STORAGE↗

Small Lunar Base Camp and in Situ Resource Utilization Oxygen Production Facility Power System Comparison

This report examines the power requirements for operating an in situ resource utilization (ISRU) oxygen production system on the lunar surface and a small six-person base camp. The baseline ISRU system produced 1.63 kg/h for a total day and night production rate of 1,154 kg. It was estimated that this plant would require 25.83 kW of power to operate. The base camp power includes auxiliary equipment as well as a communications system. The required power estimate for the base camp was 28.05 kW. This estimation was used to size a power system and determine its mass for meeting these requirements. Three types of power systems were considered: a solar photovoltaic (PV) array system using batteries for energy storage, a PV array system using a regenerative fuel cell (RFC) for energy storage, and a modular 10-kW electrical output power Kilopower reactor system. Three separate cases were examined: a stand-alone ISRU oxygen production system, a base camp, and a combined ISRU oxygen production system and base camp. For the PV array-based system, the RFC energy storage method had a mass advantage over a battery- based energy storage system. For higher power nighttime power operation for all three cases, the RFC system’s specific energy was just over 830 Wh/kg. For the lower power nighttime “keep-alive” level used as part of the Case 1 analysis, the specific energy for the RFC was 456 Wh/kg. Both of these levels are significantly above the specific energy of 200 Wh/kg for the battery. Because of this higher specific energy, the RFC-based system provided significant mass advantages over the battery-based energy storage system. The baseline reactor system utilized shielding and separation distance to meet the desired maximum radiation dose level of 5 rem/yr for personnel operating within the vicinity of the power loads, base camp, and oxygen production facility. There are methods that could potentially be utilized to reduce the shielding requirements and separation distance. Implementing these would reduce the overall system mass for the reactor. Also, optimizing the reactor output to a specific mission would provide benefits in mass at the expense of modularity. The results of the power system comparison between a solar PV array-based system and a Kilopower reactor-based system has shown that for missions required to operate throughout the lunar night at power levels comparable to those used during the day, the reactor-based system provides a significant mass advantage. However, for applications that can meet their mission requirements while only having to operate during the daytime with minimal power required to survive the nighttime, the PV array-based system provides a mass advantage.

Colozza, Anthony J.↗

Energy Arbitrage: Comparison of Options for use with LWR Nuclear Power Plants

Arbitrage is the opportunistic buying and selling of a commodity during local pricing valleys and peaks respectively to maximize economic value. This report evaluates options for energy arbitrage integrated with existing light water reactor (LWR) nuclear power plants (NPPs) where nuclear energy could be stored in a variety of forms and later recovered to generate electrical power during periods when grid electricity demand and pricing are high. The forms of energy storage examined in this report include the potential value of batteries, hydrogen, and thermal energy storage for coupling with nuclear power. Various large demand response options are also analyzed, including the production of liquid nitrogen via air separation and liquefaction, liquefaction of hydrogen, compressed hydrogen, and the cryogenic capture of CO2. Demand response refers to dispatchable loads that can cycle up or down depending on-grid electricity demand to aid in balancing the grid. Large demand response options could dispatch to aid nuclear power stations in avoiding power turndowns by providing an alternate disposition for electrical energy by producing marketable products (e.g., liquid nitrogen, hydrogen, or captured CO2). Static conditions were chosen and analyzed in this report for each option. Dynamic operation or optimization of energy arbitrage or demand response are out of scope for this report. The analysis is based on storage systems with discharge capacities of 500 MW for which various durations of storage and costs of charging (electricity cost) are examined. While the value of thermal energy to an industrial user for flexible plant operations has been previously proven as a business case, this report evaluates costs of hydrogen energy storage and leading thermal energy storage options, and large demand response loads that could be integrated with LWRs in comparison to utility-scale battery storage for use of off-peak nuclear energy. Compilation of this information will be used by the Idaho National Laboratory (INL) RAVEN/HERON systems integration and economics tool to evaluate thermal energy dispatch to industrial users. Relative ranking of energy storage options was done using a levelized cost of storage (LCOS) metric which calculates a rough breakeven cost for the system, taking into account the capital and operating costs as well as the revenue from arbitrage. Table ES1 below shows the LCOS for each of the energy storage options considered. First, in the table, lithium iron (Fe) phosphate batteries are listed as the base case for comparison against the other options. Next is hydrogen storage where most of the hydrogen analyses assumed the hydrogen to be produced using solid oxide electrolytic cell (SOEC) high temperature steam electrolysis (HTSE). The others used existing models of polymer electrolyte membrane (PEM) low temperature electrolysis to produce hydrogen. HTSE performance parameters and costs were taken from existing INL models. Various means were assumed to convert the hydrogen to electricity, including PEM fuel cells (FCs) and a gas turbine mixed in a 30 vol% mixture with natural gas. Physical storage (pressure vessels) and geological storage (natural underground features) were used to store the hydrogen as noted. Geological storage is more economical, but the locations are limited because of the requirement for pre-existing geological formations that will support storage. Thermal energy storage (TES) options were also analyzed including electro-thermal energy storage (ETES) and four different liquid sensible heat TES storage media as noted (Hitec, Hitec XL, Therminol-66, and Dowtherm A). The ETES process considered was modified using existing public documentation on an Echogen process and uses a separate supercritical CO2 charge and discharge cycle with sand as the heat storage media.

25 ENERGY STORAGE↗

Preparing Distribution Utilities for Utility-Scale Storage and Electric Vehicles: A Novel Analytical Framework

Emerging distributed energy resources (DERs)—such as solar photovoltaics (PV), battery energy storage systems (BESS), and electric vehicles (EVs)—are expected to increase substantially in India in the coming years following policy-driven targets of the Government of India to modernize its electricity system, reduce greenhouse gas emissions (GHGs), and improve air quality. These emerging technologies can pose challenges to distribution utilities, forcing overhauls in planning and operational practices. They can also create challenges in power system infrastructure planning and cause more frequent system operational violations (e.g., network voltage bounds and loading thresholds) if not properly integrated. The impacts on the localized power distribution grid from these emerging technologies manifest in increased infrastructure investments and erratic shifts in demand patterns. These impacts are not yet well understood, and analytic solutions are not readily available. To address these challenges, the National Renewable Energy Laboratory (NREL), in collaboration with BSES Rajdhani Power Ltd. (BRPL), developed an advanced power distribution system impact analysis framework of BRPL’s distribution system. This framework helps analyze the readiness of the power distribution network to accommodate emerging technologies and the potential opportunities they might introduce. The framework has been predominantly set up to evaluate distributed PV, BESS, and EVs. In this collaboration between NREL and BRPL, we developed and evaluated the framework on two distribution feeders in the BRPL territory for various scenarios of BESS and EVs. BESS are evaluated for their effectiveness on the grid to mitigate present and future feeder overloading scenarios, and they are subsequently analyzed for their costs compared to the costs of traditional upgradation measures. Scenarios include assessing the effects of EV density on grid infrastructure upgrades and interlinking EV management with BESS integration.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Sizing and Operation of a Hybrid Clean Energy Center

In this paper, we consider the deployment of battery energy storage systems (BESSs) paired with photovoltaics (PV) to form a hybrid clean energy center (HCEC), where the BESS is equipped for two main purposes: i) reducing the volatility of PV output and ii) shifting energy to meet an export limit. We develop a linear dynamical model to characterize the output of an HCEC and express the volatility and export power as functions of the battery's dispatch operations. We also propose an optimal sizing method via second-order cone programming (SOCP) to maximize the net benefits of the HCEC. Numerical studies are performed to illustrate and validate the proposed method.

Battery energy storage systems, photovoltaics, sec↗

The Economic Impact of Battery Degradation Modelling Uncertainty

Battery energy storage systems (BESS) are used for a variety of applications, with their economic benefit often being the decisive factor for deployment. A multitude of physico-chemical aging mechanisms lead to capacity fade over a BESS life cycle. The models that are used to describe this capacity fade are prone to inherent model errors. Through a holistic techno-economic modelling approach, we investigate the impact of battery degradation modelling uncertainty on the economic benefit of representative BESS applications. Here, it is shown how improved parameter fit quality can reduce the resulting economic uncertainty. Furthermore, we highlight that the consideration of degradation modelling uncertainty is especially crucial when: (i) the cash flow highly depends on the available battery capacity, (ii) a fixed, e.g. warranty mandated, state of health limit acts as the threshold for battery end-of-life, (iii) long evaluation periods and low discount rates are the focus of economic evaluation.

aging↗

Insights into ionic transport and structural changes in magnetite during multiple-electron transfer reactions

Metal oxides, such as Fe 3 O 4 , hold promise for future battery applications due to their abundance, low cost, and opportunity for high lithium storage capacity. In order to better understand the mechanisms of multiple-electron transfer reactions leading to high capacity in Fe 3 O 4 , a comprehensive investigation on local ionic transport and ordering is made by probing site occupancies of anions (O 2– ) and cations (Li + , Fe 3+ /Fe 2+ ) using multiple synchrotron X-ray and electron-beam techniques, in combination with ab-initio calculations. Results from this study provide the first experimental evidence that the cubic-close-packed (ccp) O-anion array in Fe 3 O 4 is sustained throughout the lithiation and delithiation processes, thereby enabling multiple lithium intercalation and conversion reactions. Cation displacement/reordering occurs within the ccp O-anion framework, which leads to a series of phase transformations, starting from the inverse spinel phase and turning into intermediate rock-salt-like phases (Li x Fe 3 O 4 ; 0 < x < 2), then into a cation-segregated phase (Li 2 O•FeO), and finally converting into metallic Fe and Li 2 O. Subsequent delithiation and lithiation processes involve interconversion between metallic Fe and FeO-like phases. Lastly, these results may offer new insights into the structure-determined ionic transport and electrochemical reactions in metal oxides, and those of other compounds sharing a ccp anion framework, reminiscent of magnetite.

25 ENERGY STORAGE↗

Securing Digital Energy Infrastructure: BESS Procurement Guidance & Sample Contract Terms

Presentation for Procurement webinar providing technical guidance for entities, procuring Battery Energy Storage Systems (BESS), Inverter Based Resources (IBR), Distributed Energy Resource Management Systems (DERMS) and other energy digital systems and services on how to incorporate cybersecurity requirements into the procurement process to enhance both supply chain security as well as entity-specific supply chain risk management (SCRM) programs.

99 GENERAL AND MISCELLANEOUS↗

Crossover Effects in Lithium–Metal Batteries with a Localized High Concentration Electrolyte and High–Nickel Cathodes

While crossover effects, such as transition–metal dissolution, are well–understood in lithium–ion batteries, there is a limited understanding of the effect of crossed–over chemical species in cells with oxide cathodes and lithium–metal anodes. In this work, the effects of cathode–to–anode and anode–to–cathode crossover are explored in cells with a high–nickel cathode, lithium–metal anode, and a localized high–concentration electrolyte (LHCE). Dramatic differences are found among cells; a lithium–metal anode paired with a high–nickel cathode has three times less solid–electrolyte interphase growth than a lithium–metal anode paired with lithium metal. Meanwhile, the cathode paired with lithium metal has 2–3 times higher capacity fade than the same cathode paired with graphite. Decomposition and crossover of the FSI salt is identified as the main source of these changes. The fluorine in the salt is first stripped off at the lithium–metal anode, and the remaining sulfur and nitrogen cross over to the cathode. Although the reduction in fluorine content harms the surface stability of the cathode, the lithium–metal anode benefits from the increased fluorine content. Furthermore, because the lithium–metal anode is typically the bottleneck for cells with thin lithium, crossover is a major factor in the enhanced performance of lithium–metal batteries with LHCE.

25 ENERGY STORAGE↗

Data-driven battery product development: Turn battery performance into a competitive advantage.

Poor battery performance is a primary source of user dissatisfaction across a broad range of applications, and is a key bottleneck hindering the growth of mobile technology, wearables, electric vehicles, and grid energy storage. Engineering battery systems is difficult, requiring extensive testing for vendor selection, BMS programming, and application-specific lifetime testing. This work also generates huge quantities of data. This presentation will explain how to leverage this data to help ship quality products faster using fewer resources while ensuring safety and reliability in the field, ultimately turning battery performance into a competitive advantage.

25 ENERGY STORAGE↗