Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Balloon”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Results of the 1990 NASA/JPL balloon flight solar cell calibration program

The 1990 solar cell calibration balloon flight consisted of two flights, one on July 20, 1990 and the other on September 6, 1990. A malfunction occurred during the first flight, which resulted in a complete loss of data and a free fall of the payload from 120,000 ft. After the tracker was rebuilt, and several solar cell modules were replaced, the payload was reflown. The September flight was successful and met all the objectives of the program. Forty-six modules were carried to an altitude of 118,000 ft (36.0 km). Data telemetered from the modules was corrected to 28 C and to 1 a.u. The calibrated cells have been returned to the participants and can now be used as reference standards in simulator testing of cells and arrays.

Anspaugh, Bruce E.↗

Study of balloon and thermal control material degradation aboard LDEF

The initial results of analysis performed on a number of polymeric materials which were exposed aboard the Long Duration Exposure Facility (LDEF) are discussed. These materials include two typical high altitude balloon films (a polyester and a polyethylene) and silver-backed Teflon from thermal control blanket samples. The techniques used for characterizing changes in mechanical properties, chemical structure and surface morphology include Fourier Transform Infrared (FTIR) spectroscopy, scanning electron microscopy, and dynamic mechanical analysis.

Letton, Alan↗

Aerosol sensing from balloons using photopolarimetry

A photopolarimeter designed to measure the radiance and the polarization ratio at lambda equals 0.85 microns and lambda equals 1.65 microns is set up on a gondola of a stratospheric balloon. By rotating the gondola, measurements of the diffuse solar light are obtained for a wide range of the scattering angles. An inversion scheme, based on the assumption of a log-normal size distribution, provides the relevant size parameters, the refractive index, and the slant optical thicknesses of the aerosols. Since 1983, this experiment was launched twice a year from Aire Sur Adour (S-E of France). The post-El Chichon atmospheric stratospheric aerosol proved to be quite stable in size and nature (hydratid sulfuric acid), but the abundance decreased by a factor of 10 between 1983 and 1987. The experiment was also launched to observe the stratosphere during the Arctic winter. Two flights, on January 28, 1988 and January 18, 1990, corresponded to an unperturbed atmosphere. But during a third flight, on April, 2, 1990, the temperatures were low enough for PCS formulations. A multilayer situation was observed with the standard H2SOH aerosols below 20 km; a dense layer was observed, peaked at around 23 km, with scattering coefficients about 50 times layer than in background conditions; and an upper layer was observed, rather sharp (approximately equal to 1 km), with micron sized particles.

Santer, R.↗

Ballooning stability of anisotropic, rotating plasmas

The linearized equation of motion is given in a Lagrangian representation for a rotating plasma with anisotropic pressure. A WKB theory is developed for large-n ballooning modes in an axisymmetric configuration with field-aligned and rigid toroidal flows. In the presence of field-aligned flows, it is shown that a resonance occurs which is strongly suggestive of a generalized mirror instability. In the presence of toroidal rotation, a possible stabilizing effect is identified for P(normal) greater than P(parallel). Finally, as a special case of the theory, the necessary and sufficient conditions for stability in a static, anisotropic plasma are obtained.

Wang, X.-H.↗

Balloon-borne Infrared Telescope (BIRT) for far-infrared spectroscopy

The Japanese-made Balloon-borne Infrared Telescope (BIRT) designed for FIR astronomy is described. The BIRT system includes a 50-cm-diam telescope; an attitude-control system consisting of an attitude stabilization and a pointing and tracking subsystems; the ground support system consisting of four personal-computer systems; and electronics consisting of three small computer systems, servo circuits, power amplifiers, and other small circuits. Between 1985 and 1988, the BIRT has flown eight times, demonstrating that it is able to provide a suitable telescope observations on a stable platform with a long integration time. Structural diagrams of the BIRT overall system, the optical system, and the wobbling mechanism are presented along with a block diagram of the on-board electronics.

Shibai, Hiroshi↗

New method for scanning spacecraft and balloon-borne/space-based experiments

A new method is presented for scanning balloon-borne experiments, free-flying spacecraft, and gimballed experiments mounted to the space shuttle or the space station. It uses rotating-unbalanced-mass (RUM) devices for generating circular, line, or raster scan patterns and an auxiliary control system for target acquisition, keeping the scan centered on the target, and producing complementary motion for raster scanning. It is ideal for applications where the only possible way to accomplish the required scan is to physically scan the entire experiment or spacecraft as in X-ray and gamma ray experiments. In such cases, this new method should have advantages over prior methods in terms of either power, weight, cost, performance, stability, or a combination of these.

Polites, Michael E.↗

Results of the 1991 NASA/JPL balloon flight solar cell calibration program

The 1991 solar cell calibration balloon flight was completed on August 1, 1991. All objectives of the flight program were met. Thirty-nine modules were carried to an altitude of 119,000 ft. (36.3 km). Data telemetered from the modules were corrected to 28 C and to 1 AU. The calibrated cells have been returned to the participants and can now be used as reference standards in simulator testing of cells and arrays.

Anspaugh, B. E.↗

Rotating-unbalanced-mass devices and methods for scanning balloon-borne-experiments, free-flying spacecraft, and space shuttle/space station attached experiments

A method and apparatus for scanning balloon-borne experiments, free-flying spacecraft, or gimballed experiments mounted on a space shuttle or space station, makes use of one or more rotating unbalanced mass devices for selectively generating circular, line, or raster scan patterns for the experiment line of sight. An auxiliary control system may also be used in combination with the rotating unbalanced mass device, for target acquisition, keeping the scan centered on the target, or for producing complementary motion for raster scanning. The rotating unbalanced mass makes use of a mass associated with a drive shaft, such mass having a center of gravity which is displaced from the drive shaft rotation axis. The drive shaft is driven with a substantially constant angular velocity, thereby resulting in relatively low power requirements since no acceleration or deceleration of the mass is generally involved during steady state operations. The resulting centrifugal force of the rotating unbalanced mass is used to generate desired reaction forces on the experiment or spacecraft to create a desired scan pattern for the experiment line of sight.

Polites, Michael E.↗

A balloon-borne payload for imaging hard X-rays and gamma rays from solar flares

Hard X-rays and gamma rays provide direct evidence of the roles of accelerated particles in solar flares. An approach that employs a spatial Fourier-transform technique for imaging the sources of these emissions is described, and the development of a balloon-borne imaging device based on this instrumental technique is presented. The detectors, together with the imaging optics, are sensitive to hard X-ray and gamma-ray emission in the energy-range from 20 to 700 keV. This payload, scheduled for its first flight in June 1992, will provide 11-arc second angular resolution and millisecond time resolution with a whole-sun field of view. For subsequent flights, the effective detector area can be increased by as much as a factor of four, and imaging optics with angular resolution as fine as 2 arcsec can be added to the existing gondola and metering structures.

Crannell, Carol J.↗

Joint US-USSR Long duration Antarctic Mars calibration Balloon (LAMB) mission

The Long duration Antarctic Mars calibration Balloon (LAMB) project has been established at Goddard Space Flight Center for the evaluation and cross calibration of U.S. and USSR remote sensing gamma-ray and neutron detectors. These detectors are analogs of those flown on the Soviet Phobos mission around Mars and those to be flown on the upcoming U.S. Mars Observer mission. Cosmic rays, which are normally filtered out by the atmosphere, and the earth's magnetic field, will induce gamma-ray and neutron emissions from about a half ton of simulated Mars soil aboard the gondola. The cross calibration of these instruments should greatly facilitate the data analysis from both missions and play a role in U.S.-USSR cooperation in space.

Floyd, S. R.↗

Development of a fracture toughness test for balloon film

This paper describes the equipment and test procedures being developed in an ongoing project to measure J(c) for film in a biaxial stress state. The objective of the research is to confirm J(c) as a material property whose value will permit the initiation of film tear growth to be predicted. Results are presented for two polyethylene balloon films, an LDPE and LLDPE, of thickness 0.8 mil.

Tielking, John T.↗

An assessment on the validity of toughness as a balloon film discriminator

Uniaxial and ball burst toughness for eight commercial polyethylene balloon films have been investigated and compared. Uniaxial toughness was measured in both machine and transverse directions using a rectangular sample 25.4 mm wide by 50.8 mm gage length with an average nominal thickness of 20.32 microns (0.8 mils). Ball burst toughness was measured using a ball burst test fixture with 127 mm hole diameter and 50.8 mm ball diameter resulting in a 0.4 ball to hole diameter ratio. Both the size and shape of the deformed area were observed and the ball burst toughness was calculated based on the deformed area of the film instead of the full area. Specimens were tested at 23 C and -80 C and cross head speed was maintained at 508 mm per minute. The uniaxial toughness were in general, higher than the ball burst toughness. The toughness of the films varied from 12 to 365 MPa when measured uniaxially and from 24 to 73 MPa when measured in the ball burst test. Further investigation showed an apparent correlation between film performance in flight as measured by its stress index and its toughness.

Said, Magdi A.↗

Balloon borne optical disk mass storage system

An on-board data recording system for balloon-borne interferometer using a vacuum operable, ruggedized WORM optical drive is presented. This system, as presently under development, provides 320 Mbytes of data storage (or approximately 11 hrs at the 64 kbits/sec telemetry rate of the experiment). It has the capability of recording the unmodified telemetry bit system as transmitted or doing some preprocessing of the data onboard. The system is compact and requires less than 28 watts of battery power to operate.

Vanek, M. D.↗

Preliminary results of a balloon flight of the solar disk sextant

Preliminary results of a balloon flight on October 11, 1991, of the solar disk sextant (SDS) experiment are reported. The SDS is an instrument which measures the solar diameter at different orientations with respect to the solar polar axis. Fitting straight lines through two fixed-angle data sets with time as the independent variable yields slopes of (7.1 +/ - 1.5) x 10 exp -3 and (6.7 +/- 1.6) x 10 exp -3/mas s, consistent with the value of 6.47 x 10 exp -3/mas s expected from the earth's approach to the sun due to the orbital motion toward perihelion. Upon the instrument's rotation on its axis a sinusoidal component of the diameter measurement was observed in each rotation cycle, with a variable amplitude of about 150 mas. The present result is epsilon of (5.6 +/- 6.3) x 10 exp -6, about 30 deg offset from the polar-equator position. The absolute diameter obtained by means of the FFT definition is found to be 1919.269 +/- 0.240 arcsec or 1919.131 +/- 0.240 arcsec, depending on the orientation mode of the measurement.

Maier, E.↗

Polarization analysis of a balloon-borne solar magnetograph

The main text of the report contains the particular results of our research which relate to the Experimental Vector Magnetograph (EXVM) and the Balloon-borne Vector Magnetograph (BVM). A brief overview of which elements in the EXVM and BVM that are relevant to this polarization analysis are presented. The possible meaning of the 10(exp -5) polarization specification for the BVM is discussed qualitatively. A recommendation of which polarization specification is most relevant for the BVM is provided. A diattenuation budget for the various surfaces in the BVM which will allow the polarization specification to be met is discussed. An explanation of the various coating specifications which are recommended is presented. Optical design of the EXVM and coating specification sheets for the BVM are presented. The appendices of this report contain the more general results of our research on the general topic of polarization aberrations. A general discussion of polarization aberration theory, in terms of the SAMEX solar magnetograph, and rigorous derivations for the Mueller matrices of optical systems are also presented in the appendices.

Reiley, Daniel J.↗

Results of the 1992 NASA/JPL Balloon Flight Solar Cell Calibration Program

The 1992 solar cell calibration balloon flight was completed on August 1, 1992. All objectives of the flight program were met. Forty-one modules were carried to an altitude of 119,000 ft (36.3 km). Data telemetered from the modules was corrected to 28 C and 1 AU. The calibrated cells have been returned to 39 participants and can now be used as reference standards in simulator testing of cells and arrays.

Anspaugh, B. E.↗