Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BACKGROUND NOISE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Triboelectric backgrounds to radio-based polar ultra-high energy neutrino (UHEN) experiments

Here, in the hopes of observing the highest-energy neutrinos (E EeV) populating the Universe, both past (RICE, AURA, ANITA) and current (RNO-G, ARIANNA, ARA and TAROGE-M) polar-sited experiments exploit the impulsive radio emission produced by neutrino interactions. In such experiments, rare single event candidates must be unambiguously identified above backgrounds. Background rejection strategies to date primarily target thermal noise fluctuations and also impulsive radio-frequency signals of anthropogenic origin. In this paper, we consider the possibility that ‘fake’ neutrino signals may also be generated naturally via the ‘triboelectric effect.’ This broadly describes any process in which force applied at a boundary layer results in displacement of surface charge, leading to the production of an electrostatic potential difference V. Wind blowing over granular surfaces such as snow can induce such a potential difference, with subsequent coronal discharge. Discharges over timescales as short as nanoseconds can then lead to radio-frequency emissions at characteristic MHz–GHz frequencies. Using data from various past (RICE, AURA, SATRA, ANITA) and current (RNO-G, ARIANNA and ARA) neutrino experiments, we find evidence for such backgrounds, which are generally characterized by: (a) a threshold wind velocity which likely depends on the experimental trigger criteria and layout; for the experiments considered herein, this value is typically $\mathscr{O}$(10 m/s), (b) frequency spectra generally shifted to the low-end of the frequency regime to which current radio experiments are typically sensitive (100–200 MHz), (c) for the strongest background signals, an apparent preference for discharges from above-surface structures, although the presence of more isotropic, lower amplitude triboelectric discharges cannot be excluded.

Background rejection↗

Multi-frequency and polarimetric radar backscatter signatures for discrimination between agricultural crops at the Flevoland experimental test site

We describe the calibration and analysis of multi-frequency, multi-polarization radar backscatter signatures over an agriculture test site in the Netherlands. The calibration procedure involved two stages: in the first stage, polarimetric and radiometric calibrations (ignoring noise) were carried out using square-base trihedral corner reflector signatures and some properties of the clutter background. In the second stage, a novel algorithm was used to estimate the noise level in the polarimetric data channels by using the measured signature of an idealized rough surface with Bragg scattering (the ocean in this case). This estimated noise level was then used to correct the measured backscatter signatures from the agriculture fields. We examine the significance of several key parameters extracted from the calibrated and noise-corrected backscatter signatures. The significance is assessed in terms of the ability to uniquely separate among classes from 13 different backscatter types selected from the test site data, including eleven different crops, one forest and one ocean area. Using the parameters with the highest separation for a given class, we use a hierarchical algorithm to classify the entire image. We find that many classes, including ocean, forest, potato, and beet, can be identified with high reliability, while the classes for which no single parameter exhibits sufficient separation have higher rates of misclassification. We expect that modified decision criteria involving simultaneous consideration of several parameters increase performance for these classes.

Freeman, A.↗

The microwave background temperature at 2.64 and 1.32 millimeters

Very high signal-to-noise observations of the 3874 A band of interstellar CN toward Zeta Oph are presented. Measurements are conducted of equivalent widths for the R(0), R(1), R(2), and P(1) lines which agree with previous photoelectric, but not photographic, findings. Corrected for saturation, these strengths yield excitation temperatures of 2.73 + or - 0.04 K and 2.8 + or - 0.3 K for the J = 0 to 1 and J = 1 to 2 rotational transitions at 2.64 mm and 1.32 mm respectively. Since the cosmic microwave background radiation (CMB) is primarily responsible for populating the excited rotational levels of interstellar CN toward Zeta Oph, these values are actually upper limits on the CMB brightness temperature at 2.64 mm and 1.32 mm. The results are consistent with a 2.7 K blackbody spectrum for the CMB and do not support the spectral deviations observed near these wavelengths by Woody and Richards.

Meyer, D. M.↗

Production of an Associated Particle Neutron Generator with ZnO:Ga Alpha-Detector

An associated particle neutron generator (APNG) capable of 109 neutrons per second has been operated with an alpha particle detector made of a ZnO:Ga phosphor with decay time of approximately 1 ns. Fast 14.1 MeV neutrons and 3.5 MeV alpha particles are produced through deuterium-tritium (DT) fusion reactions and travel in opposite directions to conserve momentum. The neutron generator provides high-rate capability, excellent subnanosecond time resolution (< 0.7 ns), and a large solid angle with acceptance of 8%. The alpha detector was found to have a detection efficiency of 88% using a Burle 8850 bialkali photocathode. The DT beam spot diameter was measured down to 2.1 mm with the possibility of achieving 1 mm if desired. An opaque aperture was placed on the alpha detector and the neutron beam was obstructed using various amounts of lead shielding in an effort to study the generator s imaging contrast capability for neutron radiography. The alpha detector can be pixilated using a multianode photomultiplier tube to deliver imaging capability and to enhance the signal to noise ratio. Due to its ability to suppress background, the developed APNG is to be used to search cargo containers for illicit special nuclear materials, using as a trigger prompt fission gamma ray in coincidence with an alpha particle within a 10 ns gate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Forecasting ground-based sensitivity to the Rayleigh scattering of the CMB in the presence of astrophysical foregrounds

The Rayleigh scattering of cosmic microwave background (CMB) photons off the neutral hydrogen produced during recombination effectively creates an additional scattering surface after recombination that encodes new cosmological information, including the expansion and ionization history of the universe. A first detection of Rayleigh scattering is a tantalizing target for next-generation CMB experiments. We have developed a Rayleigh scattering forecasting pipeline that includes instrumental effects, atmospheric noise, and astrophysical foregrounds (e.g., Galactic dust, cosmic infrared background, or CIB, and the thermal Sunyaev-Zel'dovich effect). We forecast the Rayleigh scattering detection significance for several upcoming ground-based experiments, including SPT-3G+, Simons Observatory, CCAT-prime, and CMB-S4, and examine the limitations from atmospheric and astrophysical foregrounds as well as potential mitigation strategies. When combined with Planck data, we estimate that the ground-based experiments will detect Rayleigh scattering with a significance between 1.6 and 3.7, primarily limited by atmospheric noise and the CIB.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FIVE-YEAR WILKINSON MICROWAVE ANISOTROPY PROBE OBSERVATIONS: SOURCE CATALOG

We present the list of point sources found in the Wilkinson Microwave Anisotropy Probe (WMAP) five-year maps. The technique used in the first-year and three-year analyses now finds 390 point sources, and the five-year source catalog is complete for regions of the sky away from the Galactic plane to a 2 Jy limit, with SNR >4.7 in all bands in the least covered parts of the sky. The noise at high frequencies is still mainly radiometer noise, but at low frequencies the cosmic microwave background (CMB) anisotropy is the largest uncertainty. A separate search of CMB-free V-W maps finds 99 sources of which all but one can be identified with known radio sources. The sources seen by WMAP are not strongly polarized. Many of the WMAP sources show significant variability from year to year, with more than a 2:1 range between the minimum and maximum fluxes.

79 ASTRONOMY AND ASTROPHYSICS↗

Detecting a gravitational-radiation background using spacecraft Doppler tracking

The sensitivity of NASA's Deep Space Network spacecraft tracking system to an isotropic cosmological background of gravitational radiation is analyzed. It is found that by using the autocovariance function of the Doppler record in the so-called 'three-way' tracking mode to dig into the noise it is possible to put significant limits on this background with current and future planned deep-space missions.

Hellings, R. W.↗

Detection of enhancement in number densities of background galaxies due to magnification by massive galaxy clusters

We present a detection of the enhancement in the number densities of background galaxies induced from lensing magnification and use it to test the Sunyaev-Zel'dovich effect (SZE-) inferred masses in a sample of 19 galaxy clusters with median redshift z similar or equal to 0.42 selected from the South Pole Telescope SPT-SZ survey. These clusters are observed by the Megacam on the Magellan Clay Telescope though gri filters. Two background galaxy populations are selected for this study through their photometric colours; they have median redshifts zmedian similar or equal to 0.9 (low-z background) and z(median) similar or equal to 1.8 (high-z background). Stacking these populations, we detect the magnification bias effect at 3.3 sigma and 1.3 sigma for the low-and high-z backgrounds, respectively. We fit Navarro, Frenk and White models simultaneously to all observed magnification bias profiles to estimate the multiplicative factor. that describes the ratio of the weak lensing mass to the mass inferred from the SZE observable-mass relation. We further quantify systematic uncertainties in. resulting from the photometric noise and bias, the cluster galaxy contamination and the estimations of the background properties. The resulting. for the combined background populations with 1 sigma uncertainties is 0.83 +/- 0.24(stat) +/- 0.074(sys), indicating good consistency between the lensing and the SZE-inferred masses. We use our best-fitting eta to predict the weak lensing shear profiles and compare these predictions with observations, showing agreement between the magnification and shear mass constraints. This work demonstrates the promise of using the magnification as a complementary method to estimate cluster masses in large surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Signal-to-noise ratio for the wide field-planetary camera of the Space Telescope

Signal-to-noise ratios for the Wide Field Camera and Planetary Camera of the Space Telescope were calculated as a function of integration time. Models of the optical systems and CCD detector arrays were used with a 27th visual magnitude point source and a 25th visual magnitude per arc-sq. second extended source. A 23rd visual magnitude per arc-sq. second background was assumed. The models predicted signal-to-noise ratios of 10 within 4 hours for the point source centered on a signal pixel. Signal-to-noise ratios approaching 10 are estimated for approximately 0.25 x 0.25 arc-second areas within the extended source after 10 hours integration.

Zissa, D. E.↗

Characterizing performance of ultra-sensitive accelerometers

An overview is given of methodology and test results pertaining to the characterization of ultra sensitive accelerometers. Two issues are of primary concern. The terminology ultra sensitive accelerometer is used to imply instruments whose noise floors and resolution are at the state of the art. Hence, the typical approach of verifying an instrument's performance by measuring it with a yet higher quality instrument (or standard) is not practical. Secondly, it is difficult to find or create an environment with sufficiently low background acceleration. The typical laboratory acceleration levels will be at several orders of magnitude above the noise floor of the most sensitive accelerometers. Furthermore, this background must be treated as unknown since the best instrument available is the one to be tested. A test methodology was developed in which two or more like instruments are subjected to the same but unknown background acceleration. Appropriately selected spectral analysis techniques were used to separate the sensors' output spectra into coherent components and incoherent components. The coherent part corresponds to the background acceleration being measured by the sensors being tested. The incoherent part is attributed to sensor noise and data acquisition and processing noise. The method works well for estimating noise floors that are 40 to 50 dB below the motion applied to the test accelerometers. The accelerometers being tested are intended for use as feedback sensors in a system to actively stabilize an inertial guidance component test platform.

Sebesta, Henry↗

Progress on Background-Limited Membrane-Isolated TES Bolometers for Far-IR/Submillimeter Spectroscopy

To determine the lowest attainable phonon noise equivalent power (NEP) for membrane-isolation bolometers, we fabricated and measured the thermal conductance of suspended Si3N4 beams with different geometries via a noise thermometry technique. We measured beam cross-sectional areas ranging from 0.35 x 0.5 (micro)m(sup 2) to 135 x 1.0 (micro)m(sup 2) and beam lengths ranging from (micro)m to 8300 (micro)m. The measurements directly imply that membrane-isolation bolometers are capable of reaching a phonon noise equivalent power (NEP) of 4 x 10(sup -20)W/Hz(sup 1)/O . This NEP adequate for the Background-Limited Infrared-Submillimeter Spectrograph (BLISS) proposed for the Japanese SPICA observatory, and adequate for NASA's SAFIR observatory, a 10-meter, 4 K telescope to be deployed at L2. Further, we measured the heat capacity of a suspended Si 3N 4 membrane and show how this result implies that one can make membrane-isolation bolometers with a response time which is fast enough for BLISS.

submillimeter spectrometer↗

Uncertainty-based weighted least squares density integration for background-oriented schlieren

We propose an improved density integration methodology for Background-Oriented Schlieren (BOS) measurements that overcomes the noise sensitivity of the commonly used Poisson solver. Here, the method employs a weighted least-squares (WLS) optimization of the 2D integration of the density gradient field by solving an over-determined system of equations. Weights are assigned to the grid points based on density gradient uncertainties to ensure that a less reliable measurement point has less effect on the integration procedure. Synthetic image analysis with a Gaussian density field shows that WLS constrains the propagation of random error and reduces it by 80% in comparison to Poisson for the highest noise level. Using WLS with experimental BOS measurements of flow induced by a spark plasma discharge shows a 30% reduction in density uncertainty in comparison to Poisson, thereby increasing the overall precision of the BOS density measurements.

42 ENGINEERING↗

The CUORE cryostat: An infrastructure for rare event searches at millikelvin temperatures

The CUORE experiment is the world's largest bolometric experiment. The detector consists of an array of 988 TeO 2 crystals, for a total mass of 742 kg. CUORE is presently taking data at the Laboratori Nazionali del Gran Sasso, Italy, searching for the neutrinoless double beta decay of 130 Te. A large custom cryogen-free cryostat allows reaching and maintaining a base temperature of ~10 mK, required for the optimal operation of the detector. This apparatus has been designed in order to achieve a low noise environment, with minimal contribution to the radioactive background for the experiment. In this paper, we present an overview of the CUORE cryostat, together with a description of all its sub-systems, focusing on the solutions identified to satisfy the stringent requirements. We briefly illustrate the various phases of the cryostat commissioning and highlight the relevant steps and milestones achieved each time. Finally, we describe the successful cooldown of CUORE.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Planck 2013 results. XXXI. Consistency of the Planck data

The Planck design and scanning strategy displays many levels of redundancy that can be exploited to provide tests of internal consistency. One of the most important is the comparison of the 70 GHz (amplifier) and 100 GHz (bolometer) channels. Based on different instrument technologies, with feeds located differently in the focal plane, analysed independently by different teams using different software, and near the minimum of diffuse foreground emission, these channels are in effect two different experiments. The 143 GHz channel has the lowest noise level on Planck , and is near the minimum of unresolved foreground emission. In this paper, we analyse the level of consistency achieved in the 2013 Planck data. We concentrate on comparisons between the 70, 100, and 143 GHz channel maps and power spectra, particularly over the angular scales of the first and second acoustic peaks, on maps masked for diffuse Galactic emission and for strong unresolved sources. Difference maps covering angular scales from 8&deg; to 15' are consistent with noise, and show no evidence of cosmic microwave background structure. Including small but important corrections for unresolved-source residuals, we demonstrate agreement (measured by deviation of the ratio from unity) between 70 and 100 GHz power spectra averaged over 70 ≤ &ell; ≤390 at the 0.8% level, and agreement between 143 and 100 GHz power spectra of 0.4% over the same &ell; range. These values are within and consistent with the overall uncertainties in calibration given in the Planck 2013 results. We also present results based on the 2013 likelihood analysis showing consistency at the 0.35% between the 100, 143, and 217 GHz power spectra. We analyse calibration procedures and beams to determine what fraction of these differences can be accounted for by known approximations or systematic errors that could be controlled even better in the future, reducing uncertainties still further. Several possible small improvements are described. Subsequent analysis of the beams quantifies the importance of asymmetry in the near sidelobes, which was not fully accounted for initially, affecting the 70/100 ratio. Correcting for this, the 70, 100, and 143 GHz power spectra agree to 0.4% over the first two acoustic peaks. The likelihood analysis that produced the 2013 cosmological parameters incorporated uncertainties larger than this. We show explicitly that correction of the missing near sidelobe power in the HFI channels would conclude in shifts in the posterior distributions of parameters of less than 0.3σ except for A s , the amplitude of the primordial curvature perturbations at 0.05 Mpc -1 , which changes by about 1σ. We extend these comparisons to include the sky maps from the complete nine-year mission of the Wilkinson Microwave Anisotropy Probe (WMAP), and find a roughly 2% difference between the Planck and WMAP power spectra in the region of the first acoustic peak.

79 ASTRONOMY AND ASTROPHYSICS↗

LoCuSS: THE MASS DENSITY PROFILE OF MASSIVE GALAXY CLUSTERS AT z = 0.2 {sup ,}

We present a stacked weak-lensing analysis of an approximately mass-selected sample of 50 galaxy clusters at 0.15 < z < 0.3, based on observations with Suprime-Cam on the Subaru Telescope. We develop a new method for selecting lensed background galaxies from which we estimate that our sample of red background galaxies suffers just 1% contamination. We detect the stacked tangential shear signal from the full sample of 50 clusters, based on this red sample of background galaxies, at a total signal-to-noise ratio of 32.7. The Navarro-Frenk-White model is an excellent fit to the data, yielding sub-10% statistical precision on mass and concentration: M{sub vir}=7.19{sup +0.53}{sub -0.50} Multiplication-Sign 10{sup 14} h{sup -1} M{sub sun}, c{sub vir}=5.41{sup +0.49}{sub -0.45} (c{sub 200}=4.22{sup +0.40}{sub -0.36}). Tests of a range of possible systematic errors, including shear calibration and stacking-related issues, indicate that they are subdominant to the statistical errors. The concentration parameter obtained from stacking our approximately mass-selected cluster sample is broadly in line with theoretical predictions. Moreover, the uncertainty on our measurement is comparable with the differences between the different predictions in the literature. Overall, our results highlight the potential for stacked weak-lensing methods to probe the mean mass density profile of cluster-scale dark matter halos with upcoming surveys, including Hyper-Suprime-Cam, Dark Energy Survey, and KIDS.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance of a high-sensitivity dedicated cardiac SPECT scanner for striatal uptake quantification in the brain based on analysis of projection data

Purpose: The authors have previously reported the advantages of high-sensitivity single-photon emission computed tomography (SPECT) systems for imaging structures located deep inside the brain. DaTscan (Isoflupane I-123) is a dopamine transporter (DaT) imaging agent that has shown potential for early detection of Parkinson disease (PD), as well as for monitoring progression of the disease. Realizing the full potential of DaTscan requires efficient estimation of striatal uptake from SPECT images. They have evaluated two SPECT systems, a conventional dual-head gamma camera with low-energy high-resolution collimators (conventional) and a dedicated high-sensitivity multidetector cardiac imaging system (dedicated) for imaging tasks related to PD. Methods: Cramer-Rao bounds (CRB) on precision of estimates of striatal and background activity concentrations were calculated from high-count, separate acquisitions of the compartments (right striata, left striata, background) of a striatal phantom. CRB on striatal and background activity concentration were calculated from essentially noise-free projection datasets, synthesized by scaling and summing the compartment projection datasets, for a range of total detected counts. They also calculated variances of estimates of specific-to-nonspecific binding ratios (BR) and asymmetry indices from these values using propagation of error analysis, as well as the precision of measuring changes in BR on the order of the average annual decline in early PD. Results: Under typical clinical conditions, the conventional camera detected 2 M counts while the dedicated camera detected 12 M counts. Assuming a normal BR of 5, the standard deviation of BR estimates was 0.042 and 0.021 for the conventional and dedicated system, respectively. For an 8% decrease to BR = 4.6, the signal-to-noise ratio were 6.8 (conventional) and 13.3 (dedicated); for a 5% decrease, they were 4.2 (conventional) and 8.3 (dedicated). Conclusions: This implies that PD can be detected earlier with the dedicated system than with the conventional system; therefore, earlier identification of PD progression should be possible with the high-sensitivity dedicated SPECT camera.

60 APPLIED LIFE SCIENCES↗

CNR considerations for rapid real-time MRI tumor tracking in radiotherapy hybrid devices: Effects of B{sub 0} field strength

Purpose: This work examines the subject of contrast-to-noise ratio (CNR), specifically between tumor and tissue background, and its dependence on the MRI field strength, B{sub 0}. This examination is motivated by the recent interest and developments in MRI/radiotherapy hybrids where real-time imaging can be used to guide treatment beams. The ability to distinguish a tumor from background tissue is of primary importance in this field, and this work seeks to elucidate the complex relationship between the CNR and B{sub 0} that is too often assumed to be purely linear. Methods: Experimentally based models of B{sub 0}-dependant relaxation for various tumor and normal tissues from the literature were used in conjunction with signal equations for MR sequences suitable for rapid real-time imaging to develop field-dependent predictions for CNR. These CNR models were developed for liver, lung, breast, glioma, and kidney tumors for spoiled gradient-echo, balanced steady-state free precession (bSSFP), and single-shot half-Fourier fast spin echo sequences. Results: Due to the pattern in which the relaxation properties of tissues are found to vary over B{sub 0} field (specifically the T{sub 1} time), there was always an improved CNR at lower fields compared to linear dependency. Further, in some tumor sites, the CNR at lower fields was found to be comparable to, or sometimes higher than those at higher fields (i.e., bSSFP CNR for glioma, kidney, and liver tumors). Conclusions: In terms of CNR, lower B{sub 0} fields have been shown to perform as well or better than higher fields for some tumor sites due to superior T{sub 1} contrast. In other sites this effect was less pronounced, reversing the CNR advantage. This complex relationship between CNR and B{sub 0} reveals both low and high magnetic fields as viable options for tumor tracking in MRI/radiotherapy hybrids.

60 APPLIED LIFE SCIENCES↗