Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Averages”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Temporal characterization of fundamental plasma parameters in pulsed liquid electrode plasma (LEP) optical emission spectrometry

The fundamental characteristics of liquid electrode plasma (LEP), a pulsed plasma source for optical emission spectrometry, were investigated. Two distinct phases were observed during the process of pulsed plasma generation, namely bubble generation and active plasma discharge. Additionally the ionization efficiency of the LEP, with Mg as a representative analyte, was gauged from the ratio of Mg II 279.553 nm to Mg I 285.213 nm emission and was found to increase from about 5% to 20% in a close-to-linear fashion with the discharge voltage from 800 V to 1200 V. The Mg II/Mg I ratio of the LEP was 2.5 to 3 orders of magnitude less than that typically offered by an inductively coupled plasma (ICP) but was comparable to other solution-based glow discharges. It was found that an off-time interval of more than 150 ms between successive discharge pulses was required to obtain a stable pulse-to-pulse discharge current. Temporally resolved emissions of Mg II 279.6 nm, Mg I 285.2 nm, Fe I 373.5 nm, OH band head at 306 nm, and Hα line at 656.3 nm showed that the background species (OH band and Hα line) reached their maximum emission intensities at around 0.5 ms to 0.7 ms with respect to the onset of the discharge pulse whereas the maximum emissions were observed between 0.7 ms to 0.9 ms for analyte species (Mg and Fe lines). The electron density observed in the present work was in the range from 5.7 × 10 15 cm -3 to 8.2 × 10 15 cm -3 , which was similar to those found in an analytical ICP. The temporal averaged OH rotational temperature was 3300 K, which was comparable to the values of an analytical ICP and solution-based glow discharges. By contrast, the temporally averaged Fe I excitation temperature was around 8900 K, which was even higher than that of an analytical ICP and roughly triple the values obtained by techniques based on glow discharge of liquid samples.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An ICP-OES method for the precise and accurate quantification of rare earth elements in natural water: A comparative study from mine waste sites in New Mexico, USA

Inductively coupled plasma techniques such as ICP-OES and ICP-MS are routinely used to determine the concentrations of rare earth elements (REE) in water samples. However, their performance for the determination of REE concentration in mine drainage waters from epithermal vein and porphyry copper mining districts has not been evaluated extensively. In this work, we develop an REE analysis method on an Agilent 5900 ICP-OES instrument and assess the accuracy and precision for the quantification of REE in the natural waters collected from mine adits and an acid seep of mine sites in the Steeple Rock and Hillsboro mining districts, New Mexico, USA. The total REE concentrations in the water samples were measured using the methods we developed for both ICP-OES and ICP-MS. The power of the new ICP-OES method lies in routine analysis of μg/L level concentrations normally analyzed using ICP-MS, including a U.S. Geological Survey standard reference sample, laboratory blank samples spiked with a National Institute of Standards and Technology traceable standard, and surface water samples from mine waste sites. This ICP-OES method achieves low quantification limits ranging from 0.2 to 5 μg/L and excellent analytical accuracy and precision for REE analysis. The precision of light (La-Gd) and heavy (Tb-Lu) REE analysis using this method are better than 5% at average concentrations above 5 ± 4 μg/L and 3 ± 2 μg/L, respectively, and 3% at average concentrations above 10 ± 9 μg/L and 5 ± 4 μg/L, respectively. This method also shows excellent sensitivity and reproducibility for our laboratory and field samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sensitivity evaluation of the Kudryavtsev permafrost model

Modeling is an important way to assess current and future permafrost spatial distribution and dynamics, especially in data poor areas like the Arctic region. Here, we evaluate a physics-based analytical model, Kudryavtsev's active layer model, which is widely used because it has relatively few data requirements. This model was recently incorporated into a component modeling toolbox, allowing for coupled modeling of permafrost and geomorphic processes over geological timescales. However, systematic quantitative assessment of the influence of its controlling parameters on permafrost temperature and active layer thickness predictions has not been undertaken before. In this work, we investigate the sensitivity of the Kudryavtsev's active layer model by Monte Carlo simulations to generate probability distributions for input parameters and compare predictions with a comprehensive benchmark dataset of in-situ permafrost observations over entire Alaska. Predicted permafrost surface temperature is highly dependent on mean annual air temperature (r = 0.78 on average), annual temperature amplitude (–0.41), and winter-averaged snow thickness (0.30). Uncertainty of predicted permafrost temperature is relatively small (RMSE = 1 °C), when air temperature and snow depth are well constrained. Similarly, RMSE between simulated and observed ALT at stations is ~0.08 m. However, under given air temperature and snow conditions, soil water content bias can significantly affect modeled active layer thickness (RMSE = 0.1 m or 40% of the observed active layer thickness). If soil water content has a large bias, improvements in other parameters may not significantly improve the active layer predictions of the Kudryavtsev's model.

54 ENVIRONMENTAL SCIENCES↗

Responses of gaseous sulfuric acid and particulate sulfate to reduced SO 2 concentration: A perspective from long-term measurements in Beijing

SO 2 concentration decreased rapidly in recent years in China due to the implementation of strict control policies by the government. Particulate sulfate ( p S O 4 2 - ) and gaseous H 2 SO 4 (SA) are two major products of SO 2 and they play important roles in the haze formation and new particle formation (NPF), respectively. We examined the change in p S O 4 2 - and SA concentrations in response to reduced SO 2 concentration using long-term measurement data in Beijing. Simulations from the Community Multiscale Air Quality model with a 2-D Volatility Basis Set (CMAQ/2D-VBS) were used for comparison. From 2013 to 2018, SO 2 concentration in Beijing decreased by ~81% (from 9.1 ppb to 1.7 ppb). p S O 4 2 - concentration in submicrometer particles decreased by ~60% from 2012–2013 (monthly average of ~10 μg·m - 3 ) to 2018–2019 (monthly average of ~4 μg·m - 3 ). Accordingly, the fraction of p S O 4 2 - in these particles decreased from 20–30% to <10%. Increased sulfur oxidation ratio was observed both in the measurements and the CMAQ/2D-VBS simulations. Despite the reduction in SO 2 concentration, there was no obvious decrease in SA concentration based on data from several measuring periods from 2008 to 2019. This was supported by the increased SA:SO 2 ratio with reduced SO 2 concentration and condensation sink. NPF frequency in Beijing between 2004 and 2019 remains relatively constant. Finally, this constant NPF frequency is consistent with the relatively stable SA concentration in Beijing, while different from some other cities where NPF frequency was reported to decrease with decreased SO 2 concentrations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Host tree species mediate corticolous lichen responses to elevated CO 2 and O 3 after 10 years exposure in the Aspen-FACE system

Lichens contribute significantly to the biodiversity and functioning of many ecosystems. Although lichens are useful air pollution bioindicators and may respond in significant ways to global change, they are studied infrequently under field conditions in chamberless exposure systems. We surveyed corticolous lichens on paper birch ( Betula papyrifera ) and trembling aspen ( Populus tremuloides ) after 10 years exposure (1998–2007) to elevated CO 2 (eCO 2 ) and O 3 (eO 3 ) in the Aspen-FACE experiment in Rhinelander, WI, USA. This experiment utilized chamberless exposure rings, 30 m in diameter, with both host trees planted together in one quadrant. Four treatments were allocated among 12 rings: ambient, eCO 2 , eO 3 , and the combination of eCO 2 + eO 3 , each replicated once in each of three blocks. Over the course of the experiment, ambient CO 2 increased from 343 to 386 ppm while eCO 2 averaged ~530 ppm CO 2 . Ambient ozone concentrations averaged ~37 ppb and ~49 ppb for eO 3 although exposures decreased with time. Tree growth and leaf area index were negatively affected by eO 3 and stimulated by eCO 2 , resulting in higher photosynthetically active radiation (PAR) in eO 3 and lower in eCO 2 . We assessed lichen richness and cover on five host trees per ring on the north-facing side of the trunks, which were higher on birch than on aspen. Additionally, neither of the lichen measures on birch responded to the exposure treatments, while on aspen lichen cover was highest in eO 3 and lowest in eCO 2 . On aspen, lichen cover was positively related to PAR and dominated by Caloplaca . No relationship was found for birch, although Lecanora exhibited a negative relationship with PAR. These lichens were insensitive to direct effects of eCO 2 and eO 3 at the levels applied. Instead, they responded to indirect effects, such as host tree species, and changes in understory PAR, resulting from direct effects of eO 3 and eCO 2 on the host trees.

54 ENVIRONMENTAL SCIENCES↗

Measurement of free chlorine levels in water using potentiometric responses of biofilms and applications for monitoring and managing the quality of potable water

We report residual free chlorine is not monitored continuously at scale in drinking water distribution systems because existing real-time sensor technologies require frequent maintenance, cleaning, and calibration, which makes these products too costly to be used throughout a distribution system. As a result, current measurement approaches require manual sampling, which is not feasible for the consistent monitoring of free chlorine because chlorine concentrations vary significantly throughout pipeline distribution and over time and space. This research presents an alternative and cost-effective method of predicting free chlorine levels in drinking water using graphite electrodes coated with naturally grown microbial biofilms. This Microbial Potentiometric Sensor (MPS) array was installed in a Continuously Mixed Batch Reactor (CMBR), and drinking water containing variable free chlorine concentrations. The chlorine concentrations were introduced in a controlled manner, and the MPS signals were monitored over time. MPS signals were measured from the change in Open Circuit Potential (OCP) across the MPS array in real-time. An empirically derived relationship between the normalized change in OCP and free chlorine was established by fitting individual and average MPS data to a decaying exponential growth function in order to predict free chlorine levels. The results show that free chlorine can be predicted with reasonable accuracy, with model validation showing an average absolute error of ±0.09 ppm below 1.1 ppm and ±0.30 ppm between 1.1 and 2.7 ppm. However, the accuracy of predictions was reduced at higher free chlorine levels. The researchers conclude that MPS systems may benefit drinking water distribution systems by measuring free chlorine. These advantages of the MPS are especially pronounced in the developing world because this system is inexpensive and does not require routine maintenance or cleaning. The system relies on a naturally forming and regenerating biofilm and an inexpensive potentiometric meter to produce stable measurements.

54 ENVIRONMENTAL SCIENCES↗

Removal, distribution and retention of metals in a constructed wetland over 20 years

The A-01 wetland treatment system (WTS) was designed to remove metals (primarily copper) from the effluent at the A-01 National Pollution Discharge Elimination System (NPDES) outfall at the Savannah River Site, Aiken, SC. This research investigated metal removal, distribution and retention in the A-01 WTS over a period of 20 years. The findings are important for ensuring continued metal sequestration in the A-01 WTSs over time, providing management guidance for constructed wetlands, and investigating changes in metal remediation effectiveness as a wetland ages. During 20 years of operation, systematic water and sediment sampling validated the wetlands' performance. After passage through the treatment cells, Cu concentrations were well below permit limits during all years of operation, often falling below 10 μg L -1 . Cu removal has been consistent over time, averaging about 80% despite large changes in influent Cu concentrations. Most divalent metals were rapidly removed from the water and held in the sediments shortly after the water entered the treatment wetland. Average removal of Pb from water by the wetland system was 67 and 74% in 2004 and 2020, respectively. Comparable values for Zn were 52 and 65%, respectively. Generally, the highest concentrations of Cu, Pb, and Zn were found in the sediment from the first cell in each pair of cells suggesting that most of the Cu, Pb, and Zn in the A-01 effluent was bound to the sediment quickly. Diffusive gradients in thin films (DGT) measurements of Cu and Zn in the sediments were much lower than bulk sediment concentrations. These results suggest that most of the Cu and Zn in the A-01 WTS sediments was not bioavailable, hence not toxic to aquatic organisms, as a likely consequence of adsorption to sediment particles and complexation with organic and inorganic substances.

54 ENVIRONMENTAL SCIENCES↗

Comparing the cooling effectiveness of operationalisable urban surface combination scenarios for summer heat mitigation

Extreme summer heat in cities exacerbates the vulnerability of urban communities to heatwaves. Vegetative and reflective urban surfaces can help reduce urban heat. This study investigated the impacts of urban trees, green roofs and cool roofs on heat mitigation during average and extreme summer conditions in temperate oceanic Melbourne, Australia. We simulated the city climate using ‘The Air Pollution Model’ (TAPM) at a 1 km spatial resolution over 10 years, which according to our review of the literature, was the most prolonged period for simulation in Melbourne. During a widespread heatwave event, some of the tested scenarios with combined surface parameters could reduce the extreme values of the energy budget components- sensible heat, latent heat, and storage heat fluxes up to seasonal averages compared to the existing situation for Melbourne (control). The scenario with the highest (reasonable maximum) ground-level vegetation, green roofs, and cool roofs could reduce air temperatures up to 2.4 °C. The simulations suggest that a combined strategy with vegetative and high-albedo surfaces will deliver higher effectiveness with maximum cooling benefits and cost-effectiveness than individual strategies in cities. These results suggest the importance of collaborative strategic planning of urban surfaces to make cities healthier, sustainable, and liveable.

54 ENVIRONMENTAL SCIENCES↗

Microstructural characterization of dendritic evolution using two-point statistics

Characterizing large four-dimensional materials datasets is difficult due to the presence of complex mi- crostructures and time-varying length scales. We showcase the use of two-point statistics as an efficient and un-biased way of extracting materials parameters from an Al-Cu alloy during solidification. The evo- lution of dendrite primary arm thickness, average secondary arm spacing, and average tip-to-tip spacing were tracked using two-point Pearson auto-correlations of scaled mean curvatures. Insights into compet- itive side-branching are also reported. We show both visually and quantitatively that most length scales change rapidly during early stages of dendritic growth, but slow as diffusion fields of dendrites overlap.

Aluminum alloys↗

Impact of transportation network companies on urban congestion: Evidence from large-scale trajectory data

We collect vehicle trajectory data from major transportation network companies (TNCs) in New York City (NYC) in 2017 and 2019, and we use the trajectory data to understand how the growth of TNCs has impacted traffic congestion and emission in urban areas. By mining the large-scale trajectory data and conduct the case study in NYC, we confirm that the rise of TNC is the major contributing factor that makes urban traffic congestion worse. From 2017 to 2019, the number of for-hire vehicles (FHV) has increased by over 48% and served 90% more daily trips. These resulted in an average citywide speed reduction of 22.5% on weekdays, and the average speed in Manhattan decreased from 11.76 km/h in April 2017 to 9.56 km/h in March 2019. The heavier traffic congestion may have led to 136% more NOx, 152% more CO and 157% more HC emission per kilometer traveled by the FHV sector. Our results show that the traffic condition is consistently worse across different times of the day and at different locations in NYC. And we build the connection between the number of available FHVs and the reduction in travel speed between the two years of data and explain how the rise of TNC may impact traffic congestion in terms of moving speed and congestion time. Our findings provide valuable insights for different stakeholders and decision-makers in framing regulation and operation policies towards more effective and sustainable urban mobility.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

2.0 - MOOSE: Enabling massively parallel multiphysics simulation

The last 2 years have been a period of unprecedented growth for the MOOSE community and the software itself. The number of monthly visitors to the website has grown from just over 3,000 to now averaging 5,000. In addition, over 1,800 pull requests have been merged since the beginning of 2020, and the new discussions forum has averaged 600 unique visitors per month. The previous publication has been cited over 200 times since it was published 2 years ago. This paper serves as an update on some of the key additions and changes to the code and ecosystem over the last 2 years, as well as recognizing contributions from the community.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Edaphic controls on genome size and GC content of bacteria in soil microbial communities

Nutrient limitation has been shown to reduce bacterial genome size and influence nucleotide composition; however, much of this work has been conducted in marine systems and the factors which shape soil bacterial genomic traits remain largely unknown. Here, for this work, we determined average genome size, GC content, codon usage, and amino acid content from 398 soil metagenomes across a broad geographic range and used machine-learning to determine the environmental parameters that most strongly explain the distribution of these traits. We found that genomic trait averages were most related to pH, which we suggest is primarily due to the correlation of pH with several environmental parameters, particularly soil carbon content. Low pH soils had higher carbon to nitrogen ratios (C:N) and tended to have communities with lower GC content and larger genomes, potentially a response to increased physiological stress and a requirement for metabolic diversity. Conversely, communities in high pH and low soil C:N had smaller genomes and higher GC content—indicating potential resource driven selection against AT base pairs, which have a higher C:N than GC base pairs. Similarly, we found that nutrient conservation also applied to amino acid stoichiometry, where bacteria in soils with low C:N ratios tended to code for amino acids with lower C:N. Together, these relationships point towards fundamental mechanisms that underpin genome size, and nucleotide and amino acid selection in soil bacteria.

54 ENVIRONMENTAL SCIENCES↗

Comparative study on the overall energy performance between photovoltaic and Low-E insulated glass units

In this report a novel semi-transparent building integrated photovoltaic (BIPV) laminate was developed and introduced in this paper. It was produced by cutting standard mono-crystalline silicon solar cells into small strips and then making electrical connections between each strip before laminating the cells between two layers of glass. The overall energy performance and energy saving potential of the BIPV insulated glass unit (IGU) under real world conditions were identified through a side by side comparative study. Compared to the reference IGU, the BIPV IGU had lower solar heat gain coefficient (SHGC) but much higher U-factor. The average HVAC electricity saving of the BIPV IGU was about 10% relative to the reference IGU. Daylighting measurement and analysis were carried out to evaluate the trade-offs associated with the BIPV IGU between daylight, glare, and lighting energy use. The results indicated that the BIPV IGU is better than the reference IGU in reducing discomfort glare. However, if the most conservative viewpoint near the window is used for the assessment, a lower transmittance BIPV IGU is required to bring the overall discomfort levels below the perceptible level. Lastly, the net energy saving potential associated with the novel BIPV IGU was identified based on the power, thermal and daylighting performance. On average, the BIPV IGU saved 16.8% of the total electricity use of the room. Further studies and improvement on the energy conversion efficiency of solar cells, the optimal transmittance as well as the thermal properties would make this technology more energy-efficient and affordable.

14 SOLAR ENERGY↗

Degradation-related defect level in weathered silicon heterojunction modules characterized by deep level transient spectroscopy

Commercial silicon heterojunction photovoltaic modules, known as amorphous-silicon-based heterojunction with intrinsic thin-film layer (HIT) modules, show average degradation after 10 years in the field. HIT modules weathered outdoors in Colorado and Florida display mostly uniform decreases in intensity when mapped with photoluminescence (PL) imaging compared to a control module. Flash-table-based current-voltage curves show that degradation is dominated by voltage loss. Samples are cored from each of the modules, and deep level transient spectroscopy (DLTS) detects three electron-trap defect states in all modules with activation energies of electron emission from the defects of 0.07, 0.16, and 0.50 eV. DLTS measurements on the weathered modules show an additional deep-level, electron-trap defect state with an activation energy of 0.51 eV and a trap density of approximately 10 12 cm –3 . The capture rate is measured using varying short filling pulse times, and the resulting capture cross section is estimated to be 1.1x10 –16 cm 2 . The development of the weathering-related defect level correlates to decreases in carrier lifetime, PL intensity, and module voltage. Various depths of the space charge region are probed with increments in applied reverse bias and filling-pulse bias. Furthermore, this DLTS depth profiling shows a trend of trap density increasing with less applied reverse bias, suggesting that the weathering-related defect increases carrier recombination toward the interface between the bulk silicon wafer and the junction-forming amorphous-silicon passivation layers.

14 SOLAR ENERGY↗

Comparing Delay-, Distance-, and Cordon-Based Congestion Pricing Strategies Via Large-Scale Simulation

This study compares the impacts of delay-, distance-, and cordon-based congestion pricing strategies for Austin, Texas, using the POLARIS agent-based activity-based travel demand simulation model. This approach enables agent-level heterogeneity and realistic choice options (including destination, mode, and activity scheduling) for dynamic traffic assignment and congestion feedbacks across a major metro region, which are features lacking in past work. To ensure comparability, distance-based tolls were set to generate the same revenue as delay-based tolling of $3.5 M/day, averaging $1.17/resident/day or $0.42/vehicle-trip. Delay-based pricing delivers 44% lower network delay and 13% lower VHT compared to the no-toll baseline, levels unmatched by other pricing strategies. At the height of the AM peak, drivers pay up to $0.13/mile on average, though most links in the network remain untolled. Distance-based pricing is the most effective at reducing VMT (by 4%), but VHT reductions (of 6%) primarily stem from drivers selecting closer destinations, achieving only one-fourth the delay reduction of delay-based pricing. Across various implementations of delay- and distance-based pricing, the results suggest that spatial variations of tolls are far more important than temporal variations. Cordon tolls produce minimal impacts at the network-wide level, but offer substantial delay reductions inside the cordon. Other major findings include: 1) delay-based pricing increases trip-making during the PM peak period due to backward shifts in discretionary-activity start times by higher-income residents; and 2) tolls’ spatial impacts, including changes in network flows and tolls paid by residents, vary substantially between delay- and distance-based pricing strategies.

Agent-based modeling↗

Cooperative lane control application for fully connected and automated vehicles at multilane freeways

Advances in communications technology have made the development of connected and automated vehicle (CAV) applications that may potentially replace traditional, gantry operated lane control signals (LCSs) possible. Here, we develop the concept of a prototype CAV-enabled LCS application and provides a preliminary assessment of the potential improvement it offers over traditional LCS. Real-world data obtained from an LCS on I-66 in Northern Virginia was used to calibrate and validate a baseline simulation model. Further, the current lane control scenarios utilized in the Northern Virginia LCS were identified and relevant data resulting from implementation of those scenarios were collected to model the LCS in a simulation environment. The performance of real-world LCS was then compared to a prototype CAV-enabled LCS application developed in this research. The CAV-enabled LCS application consistently outperformed the traditional LCS with increased throughput and speeds. On average, an increase of 18.4%, 9.6% and 12.8% in throughput was observed for three selected scenarios under the best case of a 1 sec headway. Furthermore, the CAV-enabled LCS application was also found to reduce volatility, represented by variation in acceleration and deceleration regimes, by an average of 25.6% and 49.6%. The reduction in turbulence in the traffic stream may indicate potential improved safety with the CAV system.

33 ADVANCED PROPULSION SYSTEMS↗

Electrifying education: Exploring the electrification potential of U.S. School bus fleets

We analyze the operations of 270 diesel school buses across the United States to assess their electrification potential and evaluate the impact of various charging strategies on electricity demand. We find that school buses typically follow a two-route schedule on weekdays, featuring extended dwell times between morning and evening trips. Weekday trip distances average 25 miles, while weekend trips average 42 miles. Charging simulations indicate over 90% of the U.S. school bus fleet could be electrified using current technologies (300-mile range at 1.21 kWh/mile with 19.2-kW depot charging) without modifying existing operating patterns. Depot charging is a key enabler of school bus electrification, however, the strategic placement of charging stations at other locations (e.g., schools) can further increase electrification potential. Additionally, we find electric school bus charging to be highly flexible, with charge management capable of reducing peak charging loads at depots by up to 77%.

24 POWER TRANSMISSION AND DISTRIBUTION↗