Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Air Distribution Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Small Autonomous Aircraft Servo Health Monitoring

Small air vehicles offer challenging power, weight, and volume constraints when considering implementation of system health monitoring technologies. In order to develop a testbed for monitoring the health and integrity of control surface servos and linkages, the Autonomous Aircraft Servo Health Monitoring system has been designed for small Uninhabited Aerial Vehicle (UAV) platforms to detect problematic behavior from servos and the air craft structures they control, This system will serve to verify the structural integrity of an aircraft's servos and linkages and thereby, through early detection of a problematic situation, minimize the chances of an aircraft accident. Embry-Riddle Aeronautical University's rotary-winged UAV has an Airborne Power management unit that is responsible for regulating, distributing, and monitoring the power supplied to the UAV's avionics. The current sensing technology utilized by the Airborne Power Management system is also the basis for the Servo Health system. The Servo Health system measures the current draw of the servos while the servos are in Motion in order to quantify the servo health. During a preflight check, deviations from a known baseline behavior can be logged and their causes found upon closer inspection of the aircraft. The erratic behavior nay include binding as a result of dirt buildup or backlash caused by looseness in the mechanical linkages. Moreover, the Servo Health system will allow elusive problems to be identified and preventative measures taken to avoid unnecessary hazardous conditions in small autonomous aircraft.

Quintero, Steven↗

Flight Performance Estimates for the NASA X-57 Distributed Electric Propulsion Flight Demonstrator

The X-57 flight demonstrator concept featured four configurations starting with a conventional combustion-powered multiengine airplane and ending with a fully electric configuration with two forms of distributed propulsion and a highly modified wing. These configurations, called Mods, were designed to gain incremental insight into different aircraft propulsion configuration options and their impact on the aircraft performance. The gasoline-powered Mod I configuration consumed 2.6 to 2.9 times more stored energy in cruise than the electric but otherwise conventionally configured Mod II configuration. The highly loaded wing of Mod III led to an increase of 40% in the power-off lift-to-drag ratio as compared to Mod II at the project high-speed cruise target speed and altitude. The power-on lift-to-drag ratio of Mod III was 53% higher than Mod II due to the beneficial aero-propulsive interaction of the wingtip-mounted cruise propellers in Mod III. The high-lift propeller system of Mod IV recovered the low-speed performance of the conventional configuration in Mod II that was otherwise lost with the introduction of the highly loaded Mod III wing. The battery-electric configurations also benefitted from a lack of power lapse in the electric motors with increasing air density as compared to the combustion-powered baseline aircraft.

Distributed Performance↗

Spatial and Temporal Variations of Aerosols Around Beijing in the Summer 2006: Model Evaluation and Source Apportionment

Regional aerosol model calculations were made using the WRF-CMAQ and WRF-chem models to study spatial and temporal variations of aerosols around Beijing, China, in August and September 2006 when the CAREBEIJING-2006 campaign was conducted. Model calculations were compared with in-situ observations made at the urban site in Beijing and suburb site in Yufa, which is 50 km to the south of Beijing. In general, the two model calculations reproduced features of temporal variations of meteorological parameters and concentrations of elemental carbon (EC) and inorganic aerosols (sulfate, ammonium, and nitrate). Spatial distributions of aerosol optical depth (AOD) obtained by the MODIS satellite sensor are also generally well reproduced. Model calculations show that enhancements in inorganic aerosol concentrations simultaneously observed at the two sites 4 to 5 times during the one-month observation period were resulted by accumulation of pollutants under stagnated air condition. Because Beijing is located at the north border the high anthropogenic emission area (the Great North China Plain), northward motion of air under the influence of anti-cyclone system caused enhancements in fine aerosol concentrations at Beijing. Concentrations of primary aerosols, such as EC, are found to be generally controlled by emissions within 100 km around Beijing within previous 24 hours. On the other hand, emissions as far as 500 km within previous 3 days were found to affect concentrations of secondary aerosols, such as sulfate. Because of significant contributions of secondary aerosols in Beijing, regional emission controls are found to be necessary for improvement of air quality in Beijing.

54 ENVIRONMENTAL SCIENCES↗

The computer simulation of automobile use patterns for defining battery requirements for electric cars

The modeling process of a complex system, based on the calculation and optimization of the system parameters, is complicated in that some parameters can be expressed only as probability distributions. In the present paper, a Monte Carlo technique was used to determine the daily range requirements of an electric road vehicle in the United States from probability distributions of trip lengths, frequencies, and average annual mileage data. The analysis shows that a daily range of 82 miles meets to 95% of the car-owner requirements at all times with the exception of long vacation trips. Further, it is shown that the requirement of a daily range of 82 miles can be met by a (intermediate-level) battery technology characterized by an energy density of 30 to 50 Watt-hours per pound. Candidate batteries in this class are nickel-zinc, nickel-iron, and iron-air. These results imply that long-term research goals for battery systems should be focused on lower cost and longer service life, rather than on higher energy densities

Schwartz, H.-J.↗

Flight Performance Estimates for the NASA X-57 Distributed Electric Propulsion Flight Demonstrator

The X-57 flight demonstrator concept featured four configurations starting with a conventional combustion-powered multiengine airplane and ending with a fully electric configuration with two forms of distributed propulsion and a highly modified wing. These configurations, called Mods, were designed to gain incremental insight into different aircraft propulsion configuration options and their impact on the aircraft performance. The gasoline-powered Mod I configuration consumed 2.6 to 2.9 times more stored energy in cruise than the electric but otherwise conventionally configured Mod II configuration. The highly loaded wing of Mod III led to an increase of 40% in the power-off lift-to-drag ratio as compared to Mod II at the project high-speed cruise target speed and altitude. The power-on lift-to-drag ratio of Mod III was 53% higher than Mod II due to the beneficial aero-propulsive interaction of the wingtip-mounted cruise propellers in Mod III. The high-lift propeller system of Mod IV recovered the low-speed performance of the conventional configuration in Mod II that was otherwise lost with the introduction of the highly loaded Mod III wing. The battery-electric configurations also benefitted from a lack of power lapse in the electric motors with increasing air density as compared to the combustion-powered baseline aircraft.

Distributed Performance↗

Characterization of a modified printed optical particle spectrometer for high-frequency and high-precision laboratory and field measurements

Abstract. The printed optical particle spectrometer (POPS) is a lightweight, low-cost instrument for measurements of aerosol number concentrations and size distributions. This work reports on modifications of the Handix Scientific commercial version of the POPS to facilitate its use in multi-instrument aerosol sampling systems. The flow system is modified by replacing the internal pump with a needle valve and a vacuum pump. The instrument is integrated into closed-flow systems by routing the sheath flow from filtered inlet air. A high-precision multichannel analyzer (MCA) card is added to sample the analog pulse signal. The MCA card is polled at 10 Hz frequency using an external data acquisition system and improves upon the count-rate limitation associated with the POPS internal data acquisition system. The times required to change the concentration between 90 % and 10 % and vice versa for a step change in concentration were measured to be 0.17 and 0.41 s at a flow rate of 5 cm3 s−1. This yields a sampling frequency of ∼ 1–2 Hz, below which the amplitude of measured fluctuations is captured with > 70 % efficiency. The modified POPS was integrated into the dual tandem differential mobility analyzer system to explore the coalescence of dimer particles. Results show that the pulse-height response increases upon dimer coalescence. The magnitude of the increase is broadly consistent with the change in light-scattering amplitude predicted by the T-matrix method. It is anticipated that this modified version of the POPS will extend the utilization of the technique for a range of field and laboratory applications.

54 ENVIRONMENTAL SCIENCES↗

On the mixing of a rectangular jet

Hot-wire measurements in an incompressible rectangular jet, issuing into a quiet environment at ambient conditions, are presented. A blow-down-type air supply system was used to provide the airflow to a cylindrical settling chamber 1.75 m in length and 0.6 m in diameter. The measurements were made with constant-temperature anemometers in conjunction with linearizers. The two signals from the linearizers were sent through a sum and difference unit which was calibrated from dc to 100 kHz. The distributions of mean velocity and the turbulence shear stresses were measured in the two central planes of the jet stations up to 115 widths downstream of the nozzle exit. Three distinct regions characterized the jet flow field: a potential core origin, a two-dimensional-type region, and an axisymmetric type region. The onset of the second region appeared to be at a location where the shear layers separated by the short dimension of the nozzle meet; and the third region occurred at a downstream location where the two shear layers from the short edges of the nozzle meet. In the central plane, similarity was found both in the mean velocity and shear stress profiles beyond 30 widths downstream of the nozzle exit; profiles of rms velocity showed similarity in the second, but not the third region.

Krothapalli, A.↗

A study of the application of power-spectral methods of generalized harmonic analysis to gust loads on airplanes

The applicability of some results from the theory of generalized harmonic analysis (or power-spectral analysis) to the analysis of gust loads on airplanes in continuous rough air is examined. The general relations for linear systems between power spectrums of a random input disturbance and an output response are used to relate the spectrum of airplane load in rough air to the spectrum of atmospheric gust velocity. The power spectrum of loads is shown to provide a measure of the load intensity in terms of the standard deviation (root mean square) of the load distribution for an airplane in flight through continuous rough air. For the case of a load output having a normal distribution, which appears from experimental evidence to apply to homogeneous rough air, the standard deviation is shown to describe the probability distribution of loads or the proportion of total time that the load has given values. Thus, for airplane in flight through homogeneous rough air, the probability distribution of loads may be determined from a power-spectral analysis. In order to illustrate the application of power-spectral analysis to gust-load analysis and to obtain an insight into the relations between loads and airplane gust-response characteristics, two selected series of calculations are presented. The results indicate that both methods of analysis yield results that are consistent to a first approximation.

Press, Harry↗

Lightning Charge Retrievals: Dimensional Reduction, LDAR Constraints, and a First Comparison with LIS Satellite Data

A "dimensional reduction" ("DR") method is introduced for analyzing lightning field changes ((Delta)Es) whereby the number of unknowns in a discrete two-charge model is reduced from the standard eight (x, y, z, Q, x', y', z', Q') to just four (x, y, z, Q). The four unknowns (x, y, z, Q) are found by performing a numerical minimization of a chi-square function. At each step of the minimization, an overdetermined fixed matrix (OFM) method is used to immediately retrieve the best "residual source" (x', y', z', Q'), given the values of (x, y, z, Q). In this way, all eight parameters Ix. y, z, Q, x', y', z', Q') are found, yet a numerical search of only four parameters (x, y, z, Q) is required. The DR method has been used to analyze lightning-caused (Delta)Es derived from multiple ground-based electric field measurements at the NASA Kennedy Space Center (KSC) and U.S. Air Force Eastern Range (ER). The accuracy of the DR method has been assessed by comparing retrievals with data provided by the lightning detection and ranging (LDAR) system at the KSC-ER. and from least squares error estimation theory, and the method is shown to be a useful "stand alone" charge retrieval tool. Since more than one charge distribution describes a finite set of (Delta)Es (i.e., solutions are nonunique), and since there can be appreciable differences in the physical characteristics of these solutions, not all DR solutions are physically acceptable. Hence. an alternative and more accurate method of analysis is introduced that uses LDAR data to constrain the geometry of the charge solutions. thereby removing physically unacceptable retrievals. The charge solutions derived from this method are shown to compare well with independent satellite- and ground-based observations of lightning m several Florida storms.

Koshak, W. J.↗

Cluster Node Computing for Target Generation Systems in Aircraft Simulations

Target generation systems provide virtual position and state reports of aircraft for air traffic simulations. As the scope and scale of the simulation domains expand, there is a need to develop systems that can generate position reports for thousands of simulated aircraft simultaneously at high update rates that support out-the-window visualization. This paper discusses the motivation and reasoning behind investigating development of a next generation target generator through distributed computing using clustered node processing and the benefits such a target generation system has on future research that utilizes human-in-the-loop simulations.

Monheim, Spencer↗

Invited Review. Combustion instability in spray-guided stratified-charge engines. A review

Our article reviews systematic research on combustion instabilities (principally rare, random misfires and partial burns) in spray-guided stratified-charge (SGSC) engines operated at part load with highly stratified fuel -air -residual mixtures. Results from high-speed optical imaging diagnostics and numerical simulation provide a conceptual framework and quantify the sensitivity of ignition and flame propagation to strong, cyclically varying temporal and spatial gradients in the flow field and in the fuel -air -residual distribution. For SGSC engines using multi-hole injectors, spark stretching and locally rich ignition are beneficial. Moreover, combustion instability is dominated by convective flow fluctuations that impede motion of the spark or flame kernel toward the bulk of the fuel, coupled with low flame speeds due to locally lean mixtures surrounding the kernel. In SGSC engines using outwardly opening piezo-electric injectors, ignition and early flame growth are strongly influenced by the spray's characteristic recirculation vortex. For both injection systems, the spray and the intake/compression-generated flow field influence each other. Factors underlying the benefits of multi-pulse injection are identified. Finally, some unresolved questions include (1) the extent to which piezo-SGSC misfires are caused by failure to form a flame kernel rather than by flame-kernel extinction (as in multi-hole SGSC engines); (2) the relative contributions of partially premixed flame propagation and mixing-controlled combustion under the exceptionally late-injection conditions that permit SGSC operation on E85-like fuels with very low NO x and soot emissions; and (3) the effects of flow-field variability on later combustion, where fuel-air-residual mixing within the piston bowl becomes important.

42 ENGINEERING↗

Advanced Reactors Integrated Energy System: Thermal Energy Storage Island Design

The main topic of this research is integrated energy systems (IES) designed for pairing industrial thermal energy loads with advanced reactors (ARs). The Idaho National Laboratory (INL) Crosscutting Technology Development IES program and the National Reactor Innovation Center (NRIC) are seeking to develop, design, and construct an AR-IES demonstration platform that couples the thermal output from an AR operating at the INL/NRIC Demonstration of Microreactor Experiments (DOME) test bed in the Experimental Breeder II dome to a variable capacity load emulator (i.e., air-cooled radiator) and sensible thermal energy storage (TES) via a molten salt thermal energy transfer fluid. In the rapidly evolving landscape of energy supply and distribution, flexibility has emerged as a prized attribute, surpassing the traditional notions of stability and baseload generation capability. This shift in priorities is particularly evident in the context of nuclear power plants (NPPs), where adaptability over constant output is becoming more important. As our energy infrastructure and resources embraces the rise of distributed energy generation, the inherent variability in net demand continues to grow. Moreover, the use of nuclear energy as a source of heat for decarbonizing the industrial sector is becoming a very pressing topic. In such environment, advanced NPPs are poised to enter a more competitive energy market, delivering both, flexible electricity and heat. This shift motivates the exploration of TES systems, designed to empower NPPs with nimble responsiveness to market fluctuations, flexible heat delivery capabilities, and redefine their role in the energy field. TES systems offer the unique advantage of storing nuclear energy in its original form as heat, thereby affording unparalleled flexibility in its subsequent utilization.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Voltron Compatible Whole Building Root-Fault Detection and Diagnosis

Buildings consume more than 40% of primary energy in the U.S. Malfunctioning sensors, components, and control systems, as well as degrading components in Heating, Ventilating and Air-conditioning (HVAC) and lighting systems are main reasons for energy waste and unsatisfactory indoor environment. Field studies have shown that an energy saving of 5-30% of total building energy consumption and improved indoor air quality can be achieved by simply applying automated fault detection and diagnosis (AFDD), followed by corrections even if these are not done in real time. Extensive research has been made on the development of component level AFDD tools in the past two decades. However, in recent years, the development of method for a whole building level AFDD has received much attention. Here, a whole building fault refers to a fault happening in one subsystem but impact on more than one subsystems, or has a significant impact on building performances, such as building’s energy consumption. Existing component level AFDD tools could fail to detect or give false alarm for faults that trigger abnormalities in multiple subsystems. Isolating such whole building faults, which have impacts on multiple subsystems, is also challenging by simply using component based AFDD solutions. On the other hand, it might be more cost-effective for medium- or small-sized commercial buildings that have subsystems (e.g. primary cooling subsystem, air loop subsystem, heating subsystem, lighting subsystem, etc.) to install one whole building level AFDD tool, rather than many component level AFDD tools, to focus on significant faults. The focus of this project is firstly to provide training opportunities in building AFDD research area for undergraduate students and to develop a workforce pipeline in building sciences. The objective of the proposed research activities is to develop cost-effective and scalable AFDD solutions for whole building level faults. The developed AFDD solution is VOLTTRONTM compatible to further increase its plug-n-play capacity and the market penetration. VOLTTRONTM is an open-source innovative distributed control and sensing software platform developed by the Pacific Northwest National Laboratory. A VOLTTRONTM compatible AFDD tool brings the benefits such as low-cost deployment, and better building to grid integration, etc. The performance of the developed whole building AFDD tools is evaluated using data collected from a mixed-use medium-sized university campus building. Another significant goal of this project is to engage undergraduate students in research activities and expose them to building control and AFDD fields. A demonstration building – Nesbitt Hall at Drexel University is identified for this study. This demonstration building has a typical HVAC system configuration, which includes a water-cooled chiller system, three variable air volume (VAV) air handling unit (AHU) systems, and a hydronic heating system. Faults, that are expected to have a whole building level impact, are artificially implemented in this demonstration building for three different seasons. Building data have been collected in this project, which include fault free building automation system (BAS) data and BAS data that contain system behaviors caused by artificially implemented and naturally occurred faults. These collected data are used to evaluate the developed whole building AFDD tools. A data-driven method, which includes a weather and schedule-based pattern matching (WPM) method and Feature based Principal Component Analysis (FPCA) method, is developed for whole building level fault detection. Parameter sensitivity tests, including snapshot window size, data sample searching pool size, etc., are implemented to evaluate the impacts of various WPM-FPCA parameters. A data-driven and expert knowledge/rule-based method using Bayesian Network (BN) and WPM is developed for whole building level fault diagnosis. The developed WPM-BN method, which includes a two-layer BN structure model and BN parameters, are either learned from baseline data or developed from expert knowledge. The developed whole building AFDD tools are evaluated using BAS data collected from the demonstration building. Using the evaluation data set, the WPM-FPCA fault detection method is evaluated under two different Principle Component (PC) retention rates, i.e., 0.65 retention rate and 0.95 retention rate. It is observed that when using 0.65 PC retention rate, the WPM-FPCA fault detection method achieves a 79% fault detection rate (this rate reaches to 85% when including the six make-up fault test cases discussed in the next bullet), while when using 0.95 PC retention rate, the WPM-FPCA fault detection method achieves 100% fault detection rate (this rate remains to be 100% when including the six make-up fault test cases). Under both PC retention rates, the WPM-FPCA fault detection method demonstrates 0% false alarm rates. Using the evaluation data set, the developed WPM-BN fault diagnosis method has successfully diagnosed thirteen (13) faults out of the fourteen (14) fault test cases. The one mis-diagnosed case exhibits fewer fault symptoms in different subsystems, when compared with other fault test cases. Overall speaking, the developed whole building AFDD solutions demonstrate satisfactory fault detection/diagnosis accuracy with very low false alarm rate. Lastly, a survey and market study has been performed to understand the existing AFDD market, including its gaps and needs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Incentive-Based Control and Coordination of Distributed Energy Resources. Final Report

The rapid growth of low-inertia renewable energy resources represents an immense opportunity for the U.S. to minimize its carbon footprint, while presenting a challenge for system operators as traditional “spinning” generation resources are displaced. This transformation requires solutions to robustly and cost-effectively manage dynamic changes on the grid while ensuring quality of service. There is growing recognition that distributed energy resources (DERs – loads, distributed generation, storage, electric vehicles, etc.) represent a great potential to perform this function. This report details a scalable hierarchical control strategy for coordinating thousands of heterogeneous DERs in order to provide three ancillary gird services: 1) frequency response, a rapid (within 2 seconds) service used to maintain the grid at 60 Hz; 2) regulation response, a larger response used to balance on-going differences in supply and demand on the grid; and, 3) ramping reserve, used to bring on capacity to replace lost generation. The developed control architecture consists of 1) a Distribution Reliability Coordinator (DRC), 2) aggregator controllers, and finally, 3) DER controllers. The DRC coordinates all the flexible loads and distributed energy resources on the distribution system and bids the aggregate flexibility into the wholesale market. The DRC also performs resource allocation (deciding how the flexible devices on the distribution system will be dispatched) to meet the requirements for each of the three ancillary services. The aggregators control a collection of devices that are geographically co-located and provide a platform to aggregate their flexibility and mitigate uncertainty associated with a single flexible load by managing a large aggregation of similar loads (so that any stochastic effects average out). Finally, DER controllers (for example, thermostats for air conditioners, chargers for electric vehicles) adjust the power consumption of individual devices to ensure accurate and reliable delivery of the requested grid services. Evaluation and validation of this approach was conducted with a mixture of simulation and hardware testing for a range of DERs in residential (air conditioners and water heaters), commercial HVAC (ventilation fans and central chiller plants), and micro-grids (battery energy storage, solar PV etc.). This culminated in DER hardware and simulation models operating in conjunction with grid simulations as part of a large scale federated test-bed demonstration. Simulations of over 10,000 controllable residential devices (a combination of air conditioners, water heaters, batteries, and electric vehicles) demonstrated that this advanced control approach could simultaneously meet all three grid services. Furthermore, hardware-in-the-loop testing was performed with operational micro-grid and commercial building HVAC equipment. The micro-grid equipment (representing PV, battery storage, and back-up generators) demonstrated the ability to meet all frequency response requirements (except ramping time). The commercial building HVAC ventilation equipment successfully provided the regulating response service. An Industry Advisory Board (IAB) was formed and engaged throughout the project to get feed-back on project risks and potential commercialization barriers. Their input was invaluable in identify key risks stemming from regulatory and market access challenges, financial risks from under-performance, and competitive threats from utility-scale solutions such as integrated storage. A phased commercialization plan was developed that addresses continued risk reduction (value proposition refinement and performance uncertainty assessments), piloting through field demonstrations with key stakeholders, and finally, deployment as an emerging standard for DER control.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Life cycle assessment and life cycle costs for pre-disaster waste management systems

Highlights: • Disaster waste management should include disaster waste response. • Environmental and economic disaster waste management system must be constructed. • Temporary incinerators have environmental and economic disadvantages. • Regional air pollution reduction is vital in disaster waste management planning. - Abstract: This study develops a method of environmental and economic evaluation of an integrated disaster waste management system that considers the spatial scale of removal, transport, and treatment of disaster waste. A case study was conducted on combustibles, which is a type of disaster waste derived from dwellings, in Mie Prefecture, Japan. First, we calculated the quantity and the spatial distribution of disaster waste derived from dwellings and tsunami debris produced as a result of a large-scale earthquake. The quantity of disaster waste was estimated as 7,178,000 t with functioning flood-preventing facilities and 11,956,000 t without functioning flood prevention facilities. Ensuring resilience in the face of earthquakes and tsunamis by renovating flood-preventing facilities is extremely important in decreasing the production of wastes, especially in coastal regions. Next, the transportation network for transporting combustibles in disaster waste to temporary storage sites, incineration plants, and landfill was constructed using an optimization model. The results showed that if flood-preventing facilities do not function properly, the installation of temporary incineration facilities becomes essential. Life-cycle emissions of CO{sub 2}, SO{sub x}, NO{sub x}, and PM and the costs of removal, storage, and treatment of combustibles were calculated as 258,000 t, 618 t, 1705 t, 7.9 t, and 246 million USD, respectively, in the case of functioning flood-preventing facilities. If flood-preventing facilities do not function, the quantity of environmentally unfriendly emissions and the costs increase. This result suggested the significance of renovation in order to maintain the conditions of flood-preventing facilities to decrease the environmental burden and costs as well as keep the production of disaster waste at a minimum.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of the U.S. Department of Energy Challenge Home Program Certification of Production Builders - Chicago, IL and Devens, MA

TO4 Task 3.1 - K Hovnanian Chicago, IL DOE Challenge Home Program Certified Home Constructed and Verified Specifications DOE Challenge Home Building envelope Ceiling R-49 blown fiberglass, Grade I Walls 2x4 framing @ 16 o.c. with R-13 fiberglass batts, Grade I and 1"" R-5 extruded polystyrene (XPS) insulating sheathing Frame Floors R-38 blown fiberglass, Grade I Basement Walls R-19 fiberglass batts draped full height, Grade I Basement Slab uninsulated Windows Above Grade: ENERGY STAR certified, U=0.29, SHGC=0.28 Basement: Non ENERGY STAR certified, U=0.29, SHGC=0.24 Infiltration 2 ACH 50 Mechanical systems Heat 95% AFUE sealed combustion natural gas furnace in conditioned space Goodman GMH950703BXAF Cooling 13 SEER split system Goodman GSX130301BC DHW AO Smith Vertex 100 0.96 EF natural gas tank water heater in 2nd floor utility closet Hot Water Distribution Redesigned trunk and branch Compliant with EPA WaterSense Efficient Distribution Requirements Ducts Located 100% in conditioned space via floor joists leak free to outside (5% or less) Ventilation Central Fan Integrated Supply (CFIS) ventilation with 6"" insulated outside air duct Fan Controller: Air Cycler FRV, with 6"" motorized damper 50 CFM outside air flow, 33% duty cycle (10 minutes on, 20 minutes off); ASHRAE 62.2-2010 compliance via an exhaust fan - Panasonic FV-08VQ5 WhisperCeiling Rerturn Pathways Active Return at Master Bedroom Transfer Grilles in Secondary Bedrooms Appliances, Lighting, MELs Lights 80% ENERGY STAR certified CFL Appliances ENERGY STAR certified refrigerator, dishwasher, and clothes washer; Natural gas range/oven and clothes dryer" STRUCTURE - Test House Lot 145 - 2013 DOE Challenge Test House Task 3.1 Bolingbrook, IL 60490 House is constructed and is DOE Challenge Verified by Don Nelson, a local rater. The purpose of this project was to evaluate integrated packages of advanced measures in individual test homes to assess their performance with respect to Building America Program goals, specifically compliance with the DOE Challenge Home Program. To that end, Building Science Corporation (BSC) consulted on the construction of five test houses by three cold climate production builders in three separate U.S. cities. (1) K. Hovnanian Homes, Chicago, Illinois (2) David Weekley Homes, Denver, Colorado (3) Transformations, Inc., Devens, Massachusetts. Overall, the builders have concluded that the energy related upgrades (either through the prescriptive or performance path) represent reasonable upgrades. The builders commented that while not every improvement in specification was cost effective (as in a reasonable payback period), many were improvements that could improve the marketability of the homes and serve to attract more energy efficiency discerning prospective homeowners. However, the builders did express reservations about the associated checklists and added certifications. An increase in administrative time was observed with all builders. The checklists and certifications also inherently increase cost due to: (1) Adding services to the scope of work for various trades, such as HERS Rater and heating, ventilation, and air conditioning contractor. (2) Increased material costs related to the checklists, especially the U.S. Environmental Protection Agency Indoor airPLUS and WaterSense Efficient Hot Water Distribution requirement. Ceiling - 18" cellulose Walls - 12" open cell spray foam in double stud walls Foundation - R-10 under slab, 3 1/2" closed-cell spray foam at walls Windows - Harvey U=0.20, SHGC=0.22 Infiltration - 1.0 sq in per 100 sq ft Heating - Mini split heat pump, 10.6 HSPF, 23 SEER Cooling - Mini split heat pump, 10.6 HSPF, 23 SEER DHW - 0.97 EF instantaneous propane water heater Ventilation - bathroom exhaust fans as basic option, HRV upgrade option Adams Circle Devens MA 01434 Cavite Street Devens, MA 01434

Array↗

Thermospheric wind effects on the global distribution of helium in the earth's upper atmosphere

The momentum and continuity equations for a minor gas are combined with the momentum equation for the major constituents to obtain the time dependent continuity equation for the minor species reflecting a wind field in the background gas. This equation is used to study the distributions of helium and argon at times of low, medium, and high solar activity for a variety of latitudinal-seasonal wind cells. For helium, the exospheric return flow at the higher thermospheric temperatures dominates the distribution to the extent that much larger latitudinal gradients can be maintained during periods of low solar activity than during periods of high activity. By comparison to the exospheric flow, the smoothing effect of horizontal diffusion is almost negligible. The latitudinal variation of helium observed by satellite mass spectrometers can be reproduced by the effect of a wind system of air rising in the summer hemisphere, flowing across the equator with speeds on the order of 100 to 200 m/sec, and descending in the winter hemisphere. Argon, being heavier than the mean mass in the lower thermosphere, reacts oppositely to helium in that it is enhanced in the summer hemisphere and depleted in the winter.

Reber, C. A.↗

Rescue Shuttle Flight Re-Entry: Controlling Astronaut Thermal Exposure

A rescue mission for the STS-125 Hubble Telescope Repair Mission requires reentry from space with 11 crew members aboard, exceeding past cabin thermal load experience and risking crew thermal stress potentially causing cognitive performance and physiological decrements. The space shuttle crew cabin air revitalization system (ARS) was designed to support a nominal crew complement of 4 to 7 crew and 10 persons in emergencies, all in a shirt-sleeve environment. Subsequent to the addition of full pressure suits with individual cooling units, the ARS cannot maintain a stable temperature in the crew cabin during reentry thermal loads. Bulk cabin thermal models, used for rescue mission planning and analysis of crew cabin air, were unable to accurately represent crew workstation values of air flow, carbon dioxide, and heat content for the middeck. Crew temperature models suggested significantly elevated core temperatures. Planning for an STS-400 potential rescue of seven stranded crew utilized computational fluid dynamics (CFD) models to demonstrate inhomogeneous cabin thermal properties and improve analysis compared to bulk models. In the absence of monitoring of crew temperature, heart rate, metabolic rate and incomplete engineering data on the performance of the integrated cooling garment/cooling unit (ICG/CU) at cabin temperatures above 75 degrees F, related systems & models were reevaluated and tests conducted with humans in the loop. Changes to the cabin ventilation, ICU placement, crew reentry suit-donning procedures, Orbiter Program wave-off policy and post-landing power down and crew extraction were adopted. A second CFD and core temperature model incorporated the proposed changes and confirmed satisfactory cabin temperature, improved air distribution, and estimated core temperatures within safe limits. CONCLUSIONS: These changes in equipment, in-flight and post-landing procedures, and policy were implemented for the STS-400 rescue shuttle & will be implemented in any future rescue flights from the International Space Station of stranded shuttle crews.

Gillis, David B.↗