Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Advanced Diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

LiNi 0.8 Co 0.2 O 2 -based high power lithium-ion battery positive electrodes analyzed by x-ray photoelectron spectroscopy: 6. Following calendar-life test for 2 weeks at 70 °C, 60% state-of-charge (3.747 V)

High-power lithium-ion batteries are rapidly replacing the nickel metal hydride batteries currently used for energy storage in hybrid electric vehicles. Widespread commercialization of these batteries for vehicular applications is, however, limited by calendar-life performance, thermal abuse characteristics, and cost. The Advanced Technology Development Program was established by the U.S. Department of Energy to address these limitations. An important objective of this program was the development and application of diagnostic tools that provide unique ways to investigate the phenomena that limit lithium-ion cell life, performance, and safety characteristics. This report introduces a set of six Surface Science Spectra xray photoelectron spectroscopy (XPS) comparison records of data collected from positive electrodes (cathode) harvested from cylindrically wound, 18650-type, 1 A h capacity cells. The cathodes included in this study are (1) fresh, (2) following three formation cycles, (3) following calendar-life test for 12 weeks at 40 C, 60% state-of-charge (SOC), (4) following calendar-life test for 8 weeks at 50 C, 60% SOC, (5) following calendar-life test for 8 weeks at 60 C, 60% SOC, and (6) following calendar-life test for 2 weeks at 70 C, 60% SOC.

25 ENERGY STORAGE↗

Concept for Inclusion of Analytical and Computational Capability in Optical Plume Anomaly Detection (OPAD) for Measurement of Neutron Flux

Researchers are working on many konts to make possible high speed, automated classification and quantification of constituent materials in numerous environments. NASA's Marshall Space Flight Center has implemented a system for rocket engine flow fields/plumes; the Optical Plume Anomaly Detection (OPAD) system was designed to utilize emission and absorption spectroscopy for monitoring molecular and atomic particulates in gas plasma. An accompanying suite of tools and analytical package designed to utilize information collected by OPAD is known as the Engine Diagnostic Filtering System (EDIFIS). The current combination of these systems identifies atomic and molecular species and quantifies mass loss rates in H2/O2 rocket plumes. Additionally, efforts are being advanced to hardware encode components of the EDIFIS in order to address real-time operational requirements for health monitoring and management. This paper addresses the OPAD with its tool suite, and discusses what is considered a natural progression: a concept for migrating OPAD towards detection of high energy particles, including neutrons and gamma rays. The integration of these tools and capabilities will provide NASA with a systematic approach to monitor space vehicle internal and external environment.

Patrick, M. Clinton↗

Development and Testing of Propulsion Health Management

An Integrated Vehicle Health Management system aims to maintain vehicle health through detection, diagnostics, state awareness, prognostics, and lastly, mitigation of detrimental situations for each of the vehicle subsystems and throughout the vehicle as a whole. This paper discusses efforts to advance Propulsion Health Management technology for in-flight applications to provide improved propulsion sensors measuring a range of parameters, improve ease of propulsion sensor implementation, and to assess and manage the health of gas turbine engine flow-path components. This combined work is intended to enable real-time propulsion state assessments to accurately determine the vehicle health, reduce loss of control, and to improve operator situational awareness. A unique aspect of this work is demonstration of these maturing technologies on an operational engine.

Hunter, Gary W.↗

Physics of Acoustic Radiation from Jet Engine Inlets

Numerical simulations of acoustic radiation from a jet engine inlet are performed using advanced computational aeroacoustics (CAA) algorithms and high-quality numerical boundary treatments. As a model of modern commercial jet engine inlets, the inlet geometry of the NASA Source Diagnostic Test (SDT) is used. Fan noise consists of tones and broadband sound. This investigation considers the radiation of tones associated with upstream propagating duct modes. The primary objective is to identify the dominant physical processes that determine the directivity of the radiated sound. Two such processes have been identified. They are acoustic diffraction and refraction. Diffraction is the natural tendency for an acoustic wave to follow a curved solid surface as it propagates. Refraction is the turning of the direction of propagation of sound waves by mean flow gradients. Parametric studies on the changes in the directivity of radiated sound due to variations in forward flight Mach number and duct mode frequency, azimuthal mode number, and radial mode number are carried out. It is found there is a significant difference in directivity for the radiation of the same duct mode from an engine inlet when operating in static condition and in forward flight. It will be shown that the large change in directivity is the result of the combined effects of diffraction and refraction.

Tam, Christopher K. W.↗

Evaluation of Regional Water and Energy Balance in Contemporary Reanalyses

Regional to continental water and energy balance in reanalyses provide crucial information on the climate and climate variations in that region and can contrast other regions. Reanalyses are a valuable tool in piecing together the complete balance owing to the incorporation of the budgets in the background model and the assimilation of observation. On the other hand, the background model has its own biases and observational assimilation can lead to non-negligible tendencies within the budgets, and these can vary over space and time. Here, we will compare the balance within several reanalyses and how they have evolved over recent decades. Several observational data products will provide reference points in the comparison. In addition, a recent project has integrated observations of the water and energy budgets in an optimization that aims to reduce the imbalance of regional budgets in using observational terms from disparate sources. In evaluating the regional balances, we will incorporate, when available, the water and energy convergence terms as well as their analysis increments (which may be diagnosed as residuals). The reanalyses considered here include: Japanese Reanalyses for Three Quarters Century (JRA3Q), ECMWF Reanalysis version 5 (ERA5), Modern Era Retrospective-analysis for Research and Applications version 2 (MERRA-2) and the NCEP Reanalysis II (NCEPR2). NCEPR2 is representative of the late 90s technology, while the others represent the contemporary climate reanalyses presently available. We will discuss the regional balances over key river basins (e.g. Mississippi and Amazon), and a range of continents including those well observed (North America and Europe) and those with fewer consistent observations (e.g. Africa). These contrasting regions show the degree of advancement in reanalyses and expose areas in need of improvement. The results also demonstrate the usefulness of producing complete atmospheric water and energy budgets as part of the diagnostic output.

Michael G Bosilovich↗

Evaluation of Regional Water and Energy Balance in Contemporary Reanalyses

Regional to continental water and energy balance in reanalyses provide crucial information on the climate and climate variations in that region and can contrast other regions. Reanalyses are a valuable tool in piecing together the complete balance owing to the incorporation of the budgets in the background model and the assimilation of observation. On the other hand, the background model has its own biases and observational assimilation can lead to non-negligible tendencies within the budgets, and these can vary over space and time. Here, we will compare the balance within several reanalyses and how they have evolved over recent decades. Several observational data products will provide reference points in the comparison. In addition, a recent project has integrated observations of the water and energy budgets in an optimization that aims to reduce the imbalance of regional budgets in using observational terms from disparate sources. In evaluating the regional balances, we will incorporate, when available, the water and energy convergence terms as well as their analysis increments (which may be diagnosed as residuals). The reanalyses considered here include: Japanese Reanalyses for Three Quarters Century (JRA3Q), ECMWF Reanalysis version 5 (ERA5), Modern Era Retrospective-analysis for Research and Applications version 2 (MERRA-2) and the NCEP Reanalysis II (NCEPR2). NCEPR2 is representative of the late 90s technology, while the others represent the contemporary climate reanalyses presently available. We will discuss the regional balances over key river basins (e.g. Mississippi and Amazon), and a range of continents including those well observed (North America and Europe) and those with fewer consistent observations (e.g. Africa). These contrasting regions show the degree of advancement in reanalyses and expose areas in need of improvement. The results also demonstrate the usefulness of producing complete atmospheric water and energy budgets as part of the diagnostic output.

Michael Bosilovich↗

Autonomous Diagnostic Imaging Performed by Untrained Operators using Augmented Reality as a Form of "Just-in-Time" Training

We will address the Human Factors and Performance Team, "Risk of performance errors due to training deficiencies" by improving the JIT training materials for ultrasound and OCT imaging by providing advanced guidance in a detailed, timely, and user-friendly manner. Specifically, we will (1) develop an audio-visual tutorial using AR that guides non-experts through an abdominal trauma ultrasound protocol; (2) develop an audio-visual tutorial using AR to guide an untrained operator through the acquisition of OCT images; (3) evaluate the quality of abdominal ultrasound and OCT images acquired by untrained operators using AR guidance compared to images acquired using traditional JIT techniques (laptop-based training conducted before image acquisition); and (4) compare the time required to complete imaging studies using AR tutorials with images acquired using current JIT practices to identify areas for time efficiency improvements. Two groups of subjects will be recruited to participate in this study. Operator-subjects, without previous experience in ultrasound or OCT, will be asked to perform both procedures using either the JIT training with AR technology or the traditional JIT training via laptop. Images acquired by inexperienced operator-subjects will be scored by experts in that imaging modality for diagnostic and research quality; experts will be blinded to the form of JIT used to acquire the images. Operator-subjects also will be asked to submit feedback to improve the training modules used during the scans to improve future training modules. Scanned-subjects will be a small group individuals from whom all images will be acquired.

Martin, D. S.↗

Autonomous Diagnostic Imaging Performed by Untrained Operator Using Augmented Reality as a Form of "Just-in-Time" Training

We will address the Human Factors and Performance Team, "Risk of performance errors due to training deficiencies" by improving the JIT training materials for ultrasound and OCT imaging by providing advanced guidance in a detailed, timely, and user-friendly manner. Specifically, we will (1) develop an audio-visual tutorial using AR that guides non-experts through an abdominal trauma ultrasound protocol; (2) develop an audio-visual tutorial using AR to guide an untrained operator through the acquisition of OCT images; (3) evaluate the quality of abdominal ultrasound and OCT images acquired by untrained operators using AR guidance compared to images acquired using traditional JIT techniques (laptop-based training conducted before image acquisition); and (4) compare the time required to complete imaging studies using AR tutorials with images acquired using current JIT practices to identify areas for time efficiency improvements. Two groups of subjects will be recruited to participate in this study. Operator-subjects, without previous experience in ultrasound or OCT, will be asked to perform both procedures using either the JIT training with AR technology or the traditional JIT training via laptop. Images acquired by inexperienced operator-subjects will be scored by experts in that imaging modality for diagnostic and research quality; experts will be blinded to the form of JIT used to acquire the images. Operator-subjects also will be asked to submit feedback to improve the training modules used during the scans to improve future training modules. Scanned-subjects will be a small group individuals from whom all images will be acquired.

Martin, David S.↗

Propulsion Integrated Vehicle Health Management Technology Experiment (PITEX) Conducted

The Propulsion Integrated Vehicle Health Management (IVHM) Technology Experiment (PITEX) is a continuing NASA effort being conducted cooperatively by the NASA Glenn Research Center, the NASA Ames Research Center, and the NASA Kennedy Space Center. It was a key element of a Space Launch Initiative risk-reduction task performed by the Northrop Grumman Corporation in El Segundo, California. PITEX's main objectives are the continued maturation of diagnostic technologies that are relevant to second generation reusable launch vehicle (RLV) subsystems and the assessment of the real-time performance of the PITEX diagnostic solution. The PITEX effort has considerable legacy in the NASA IVHM Technology Experiment for X-vehicles (NITEX) that was selected to fly on the X-34 subscale RLV that was being developed by Orbital Sciences Corporation. NITEX, funded through the Future-X Program Office, was to advance the technology-readiness level of selected IVHM technologies within a flight environment and to begin the transition of these technologies from experimental status into RLV baseline designs. The experiment was to perform realtime fault detection and isolation and suggest potential recovery actions for the X-34 main propulsion system (MPS) during all mission phases by using a combination of system-level analysis and detailed diagnostic algorithms.

Maul, William A.↗

Fluctuations and Self-Organization in Plasma Boundary Layers (Final Report)

Final technical report on an experimental study of the boundary of an ionized gas (plasma) where it interacts with solid surfaces. The plasma self-organizes into a sheath which experiences plasma flow and is naturally unstable to various fluctuations which can be observed with advanced laser-spectroscopy techniques.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermal Dynamics and Lithium Plating Detection in High‐Power Li‐Ion Batteries for eVTOL Applications

The rapid electrification of aerial transportation is driving the need for high‐performance Li‐ion batteries that can operate reliably under stringent thermal and safety constraints. The unique mission profile of electric Vertical Take‐off and Landing (eVTOL) aircraft necessitates a focused investigation into the thermal behavior and safety characteristics of these batteries. Here, in this study, operando isothermal microcalorimetry is employed to examine the thermal evolution of Li‐ion batteries under cycling conditions representative of eVTOL operations. These findings reveal that high‐power discharge events—such as those during take‐off and landing—shift the thermal response toward exothermic behavior, in contrast to the typically endothermic response expected under near‐equilibrium cycling conditions. Additionally, the results suggest that advanced electrolyte formulations may help suppress excess heat generation, thereby improving battery safety. Notably, the calorimetric results exhibit a distinct thermal signature associated with lithium plating, offering a potential diagnostic for detecting Li plating during eVTOL operation. Overall, this study demonstrates the utility of isothermal microcalorimetry as a valuable tool for assessing thermal risks in Li‐ion batteries for eVTOL applications, and highlights the importance of targeted design strategies to mitigate safety hazards during high‐power demand scenarios.

Li plating↗

Short-Term Effects of Ankaferd Hemostat for Renal Artery Embolization: An Experimental Study

Renal artery embolization (RAE) is a minimally invasive therapeutic technique that is utilized in a number of disorders. Ankaferd is a novel hemostatic agent with a new mechanism of action independent of clotting factors. We used Ankaferd for RAE in a sheep model. Seven adult female sheep were included in the study. Selective renal arteriogram using 5-F diagnostic catheter was performed to make sure that each kidney was fed by a single renal artery and the animal had normal renal vasculature. Coaxial 2.7-F microcatheter was advanced to the distal main renal artery. Under fluoroscopic guidance, 2 mL of Ankaferd mixed with 2 mL of nonionic iodinated contrast agent was slowly injected. Fluoroscopy was used to observe the deceleration of flow and stagnation. Control renal angiograms were performed just after embolization. After the procedure, the animals were observed for 1 day and then sacrificed with intravenous sodium thiopental. The technical success was observed in seven of the seven animals.. After embolization procedure, none of the animals died or experienced a major systemic adverse event. On macroscopic examination of the embolized kidneys, thrombus at the level of main renal artery formed after Ankaferd embolization was more compact compared with the thrombi that was not Ankaferd-associated, which was observed elsewhere. Microscopically, majority of the renal tubular cells (80-90 %) were necrotic, and there was epithelial cell damage in a small portion of the cells (10-20 %). RAE was safe and effective in the short-term with Ankaferd in studied animals. Further studies should be conducted to better delineate the embolizing potential of this novel hemostatic agent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Self-detection of x-ray Fresnel transmissivity using photoelectron-induced gas ionization

Electric response of an x-ray mirror enclosed in a gas flow ionization chamber was studied under the conditions of total external reflection for hard x-rays. It is shown that the electric response of the system as a function of the incidence angle is defined by x-ray Fresnel transmissivity and photon-electron attenuation properties of the mirror material. A simple interpretation of quantum yield of the system is presented. The approach could serve as a basis for non-invasive in situ diagnostics of hard x-ray optics, easy access to complementary x-ray transmissivity data in x-ray reflectivity experiments, and might also pave the way to advanced schemes for angle and energy resolving x-ray detectors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comprehensive Analysis of Streaming and Shutdown Dose Rate Experiments at JET with ORNL Fusion Neutronics Workflows

Current experimental fusion systems and conceptual designs of fusion pilot plants (FPPs) are growing in complexity and size. Several radiation metrics are crucial to the safe operation of fusion machines, including neutron flux streaming through openings and the shutdown dose rate (SDDR). Most current designs of advanced experimental fusion systems—and the most probable candidates for FPPs—are based on the tokamak concept, which is prone to neutron streaming through the myriad openings needed for diagnostic and support systems. SDDR is caused by decay gamma rays from radionuclides that become activated by neutrons during the operation of a fusion system that use deuterium-deuterium (DD), tritium-tritium, or deuterium-tritium plasma. Because computational tools have become essential for determining these radiation metrics, they must be validated against reliable and applicable experimental data. Experiments at the Joint European Torus (JET) provide a unique source of experimental data for validating computational tools and nuclear data used to determine SDDR and neutron fluxes in streaming-dominated geometries. Here, this paper presents the comprehensive analysis of the high-performance DD JET SDDR, and streaming experiments performed using Oak Ridge National Laboratory (ORNL) fusion workflows. The computational results were compared with experimental results that consist of online SDDR measurements with ionization chambers and neutron fluence streaming measurements using thermoluminescent detectors. The ratio of calculated-to-experimental SDDR values ranges from 0.6 to 2.5, and the streaming results range from 0.5 to 8.0. Future work will include analyzing the JET 2021 DTE2 campaign alongside the integration of the Shift Monte Carlo transport code into all ORNL fusion neutronics workflows.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Applied Nanotechnology for Human Space Exploration

A viewgraph presentation describing nanotechnology for human space exploration is shown. The topics include: 1) NASA's Strategic Vision; 2) Exploration Architecture; 3) Future Exploration Mission Requirements Cannot be met with Conventional Materials; 4) Nanomaterials: Single Wall Carbon Nanotubes; 5) Applied Nanotechnology at JSC: Fundamentals to Applications; 6) Technology Readiness Levels (TRL); 7) Growth, Modeling, Diagnostics and Production; 8) Characterization: Purity, Dispersion and Consistency; 9) Processing; 10) Nanoelectronics: Enabling Technologies; 11) Applications for Human Space Exploration; 12) Exploration Life Support: Atmosphere Revitalization System; 13) Advanced and Exploration Life Support: Regenerable CO2 Removal; 14) Exploration Life Support: Water Recovery; 15) Advanced Life Support: Water Disinfection/Recovery; 16) Power and Energy: Supercapacitors and Fuel Cells; 17) Nanomaterials for EMI Shielding; 18) Active Radiation Dosimeter; 19) Advanced Thermal Protection System (TPS) Repair; 20) Thermal Radiation and Impact Protection (TRIPS); 21) Nanotechnology: Astronaut Health Management; 22) JSC Nanomaterials Group Collaborations.

Yowell, Leonard L.↗

Development of Carbon Flux Model Using ABI Data Over the Conterminous US

The satellite-driven carbon flux estimation has been playing important role to estimate continental-scale carbon budget. One of the biggest recent advances in the satellite-driven carbon flux modeling is utilization of high-frequent geostationary satellites to estimate diurnal cycle in carbon fluxes. The satellite based carbon flux estimation used the polar orbiting satellite sensors (e.g., Moderate Resolution Imaging Spectroradiometer (MODIS)), which allow us to observe target regions only once during the day. The new generation of geostationary satellite sensors provide frequent observations, often less than every 10 minutes. Here, we use GOES Advanced Baseline Imager (ABI) data to estimate hourly NEE over the conterminous US. We used the Terrestrial Observation Prediction System (TOPS) model for estimating hourly NEE. TOPS is a diagnostic ecosystem process model that simulates the fluxes of carbon and water through vegetation in response to climate variability. For the climate input, we developed hourly climate data using the same algorithm with NASA Earth Exchange Gridded Daily Meteorology (NEX-GDM) datasets based on machine learning techniques. The hourly climate data includes precipitation, maximum temperature, minimum temperature, dew point temperature, and solar radiation were derived from the Geostationary observations. The spatial patterns of ecosystem parameters used in TOPS are optimized using satellite Solar Induced Fluorescence (SIF) data. The high frequency GPP estimations from geostationary satellite sensors make it comparable to the instantaneous SIF data than daily GPP. We also used Ameriflux data for optimization of model parameters and the validation of the output. The derived data addresses the diurnal dynamics of carbon cycling at large scales and should help in reducing the uncertainties in carbon budget studies.

geostationary satellite↗

Residual gas analysis for long-pulse, advanced tokamak operation

A shielded residual gas analyzer (RGA) system on Tore Supra can function during plasma operation and is set up to monitor the composition of the neutral gas in one of the pumping ducts of the toroidal pumped limited. This ''diagnostic RGA'' has been used in long-pulse (up to 6 min) discharges for continuous monitoring of up to 15 masses simultaneously. Comparison of the RGA-measured evolution of the H{sub 2}/D{sub 2} isotopic ratio in the exhaust gas to that measured by an energetic neutral particle analyzer in the plasma core provides a way to monitor the evolution of particle balance. RGA monitoring of corrective H{sub 2} injection to maintain proper minority heating is providing a database for improved ion cyclotron resonance heating, potentially with RGA-base feedback control. In very long pulses (>4 min) absence of significant changes in the RGA-monitored, hydrocarbon particle pressures is an indication of proper operation of the actively cooled, carbon-based plasma facing components. Also H{sub 2} could increase due to thermodesorption of overheated plasma facing components.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-A-BRF-01: Dual-Energy CT Imaging in Diagnostic Imaging and Radiation Therapy

The quantification accuracy of dual-energy imaging is influenced by the fundamentals of x-ray physics, system geometry, data acquisition hardware/protocol, system calibration, and image processing technique. This symposium will provide updates on the following advanced application areas: Mammography. Volumetric breast density techniques based on standard mammograms require estimation of breast thickness, which is difficult to accurately measure. By comparison, calculation of breast density using dual energy mammography does not require measurement of breast thickness. Dual energy mammography has been implemented using both energy integrating flat panel detectors in conjunction with beam energy switching and energy resolved photon counting detectors. These techniques have been optimized using simulation studies and validated using physical phantoms and postmortem breasts. Chemical decomposition was used as the gold standard for volumetric breast density measurement in postmortem breasts. Breast density measurements have also been compared with results from four-category BI-RADS density rankings, standard image thresholding and Fuzzy k-mean clustering techniques. These studies indicate that dual energy mammography can be used to accurately measure volumetric breast density. Cardiovascular CT. The predicative accuracy of risk models for recurrent stroke and cardiac arrest depends heavily on accurate differentiation of thrombus or calcium from iodine in left atrial appendage or coronary arteries. The amount of energy separation is constrained by image noise; therefore, optimal kVp, beam filtration, and balanced flux are essential for the quantification accuracy of iodine and calcium. The basis materials are combined linearly to generate monochromatic energy images, where CT# accuracy and CNR are energy dependent. With optimal monochromatic energy, the mean iodine concentration for the thrombus, circulatory stasis, and control groups are significantly different. Risk classification based on calcium scores shows excellent agreement with classification on the basis of conventional coronary artery calcium scoring. These studies demonstrate dual-energy cardiovascular CT can potentially be a noninvasive and sensitive modality in high risk patients. On-board KV/MV Imaging. To enhance soft tissue contrast and reduce metal artifacts, we have developed a dual-energy CBCT technique and a novel on-board kV/MV imaging technique based on hardware available on modern linear accelerators. We have also evaluated the feasibility of these two techniques in various phantom studies. Optimal techniques (energy, beam filtration, # of overlapping projections, etc) have been investigated with unique calibration procedures, which leads to successful decomposition of imaged material into acrylic-aluminum basis material pair. This enables the synthesis of virtual monochromatic (VM) CBCT images that demonstrate much less beam hardening, significantly reduced metal artifacts, and/or higher soft tissue CNR compared to single-energy CBCT. Adaptive Radiation Therapy. DECT could actually contribute to the area of Dose-Guided Radiation Therapy (or Adaptive Therapy). The application of DECT imaging using 80kV and 140 kV combinations could potentially increase the image quality by reducing the bone or high density material artifacts and also increase the soft tissue contrast by a light contrast agent. The result of this higher contrast / quality images is beneficial for deformable image registration / segmentation algorithm to improve its accuracy hence to make adaptive therapy less time consuming in its recontouring process. The real time re-planning prior to per treatment fraction could become more realistic with this improvement especially in hypofractional SBRT cases. Learning Objectives: Learn recent developments of dual-energy imaging in diagnosis and radiation therapy; Understand the unique clinical problem and required quantification accuracy in each application; Understand the different approaches to optimize dual-energy imaging techniques for different applications.

60 APPLIED LIFE SCIENCES↗